1-6 62-02575-07 1.3 DataCORDER INTERFACE
The DataCORDER is capable of performing the following functions initiated by the DataView Program
1.3.1 Data Extraction
a. Daily Header Data
Recorded days are presented in the following format:
1. Day 1 date (month, day, year), sensor data, events, ...
2. Day 2 date (month, day, year), sensor data, events, ...
b. Sensor Data
Sensor data will be read based on either standard or generic configuration. Please refer to separately bound manuals
covering the...

Page 12

1-7 62-02575-07 Table 1-3. Temperature Controller Events -- Continued
Event
When Event OccursData SentLimits
Tri p S t art (TS )Any time trip start is en-
teredNANA
USDA Trip CommentWhen entered with
interrogation deviceUp to 80 bytes of custom-
er comment dataLast 1 per day
Pre-Trip Data
Any time a Pre-Trip test is
completed and Controller
is configured to send indi-
vidual test dataPass/Fail for each sub-test,
and appropriate data points
for each test
Unlimited
Economy Mode Start
(ECON_S)Any time...

Page 13

1-8 62-02575-07Table 1-4 DataCORDER Events -- Continued
Event
When Event OccursData StoredLimits
Power ON (ON)
Restoration of AC power
with no battery pack pres-
ent
NANA
Data RetrievalExtraction of data from
the DataCORDERNANA
Real Time Clock ChangeUser modifies the real
time clock (RTC)New Date and Time; Old
Date and TimeNA
RTC Battery Replaced
Real Time Clock (RTC)
battery internal to Data-
CORDER is replaced
NALast 1 per hour, last 1 per
day
Controller Not
Responding (NWF)
DataCORDER attempted
to...

Page 14

1-9 62-02575-07 Table 1-5 Controlled Atmosphere (CA) Events Recorded in the DataCORDER -- Continued
Event
When Event OccursDataLimits
O2Air CalibrationWhenever O2Air Cal-
ibration is completedNew calibration value; Result
(pass, fail, or low) Source (key-
pad, communications, or timer)Last 2 per hour, last
10 per day
O2Gas CalibrationWhenever O2Gas Cal-
ibration is completedNew calibration value; Result
(pass or fail) Source (keypad,
communications, or timer)Last 2 per hour, last
10 per day
CO2Zero...

Page 15

1-10 62-02575-07 1.4 USDA RECORDING
A special type of recording is provided for USDA cold treatment purposes. Cold treatment recording requires that
three remote temperature probes are placed in the cargo at various locations. Provision is made to connect these probes
to the DataCORDER via receptacles located at the rear left-hand side of the unit. Four (five, on some units) receptacles
are provided. Four (three-pin) receptacles are for the probes and one (five pin) receptacle is provided for the...

Page 16

2-1 62-02575-07
SECTION 2
SYSTEM SETUP
2.1 HARDWARE PLATFORMS SUPPORTED
The DataView Software will run on a variety of DOS based machines. We recommend the use of a desktop or laptop
machine with at least 3MB free disk space and a VGA monitor for displaying graphics, for most printing and report
generation functions. Other, less capable computers may be used for the actual data extraction.
2.2 INTERROGATION CABLES
Cable requirements may differ between interrogation devices. For cable connections see...

Page 17

2-2 62-02575-07 2.3 PRINTER SUPPORT
Formatted reports can be generated on the following printers:
1. EPSON 85 dot matrix or compatible (most dot matrix printers will support this format)
2. HP LaserJet or equivalent (Many laser printers will support this format).
For printers that are not compatible with the above printers, select the FILE printer port option in printer setup. This
will send the report to an ASCII print file.
2.3.1 PERSONAL COMPUTER PRINTING CABLE CONNECTIONS
After the DataCORDER has...

Page 18

3-1 62-02575-07
SECTION 3
DATAVIEW PROGRAM INSTRUCTIONS
NOTE
The following is a copy of the software program at time of printing. If loading only one program
(12--00413 reciprocating unit interrogation or 12--00528 scroll unit interrogation program) the pro-
gram disc instructions may be followed as written. If loading both programs on the same computer,
different resident directories must be created Where these differences exist, annotation has been add-
ed to the text provided herein.
Refer to the...

Page 19

3-2 62-02575-07 Printers Supported
1. EPSON 85 dot matrix or compatible (most dot matrix printers support this format).
2. HP Laser Jet or equivalent (many laser printers support this format).
For printers that are not compatible with the above printers, select the FILE printer port option in printer setup. This
will send the report to an ASCII print file.
TOPIC 2 DESKTOP QUICK START
This section describes the installation procedure for the DOS DataView interrogator program.
Installation From MS -- DOS...

Page 20

3-3 62-02575-07
i) Creates the sub directory C:\“directory”\DATA, where “directory” is the directory defined in step c. This is the
working directory where the DCX files are stored.
j) Creates the sub directory C:\“directory”\PRN_FLS, where “directory” is the directory defined in step c. This is the
print file directory where the ASCII Text print files are stored.
k) The user shall be notified when the installation is complete via the Installation Completion Screen and given direc-
tions on how to...