Carrier Air 5 Manual
Here you can view all the pages of manual Carrier Air 5 Manual. The Carrier manuals for Air Conditioner are available online for free. You can easily download all the documents as PDF.
Page 41
T-- 298 3-17 3.11.2 Timeguard Timer A 3-- minute timeguard is built into the thermostat immediately upon power up, and any time the compressor (output “Y”) turns off. The compressor will not turn on until the timeguard has expired. Pressing UP and FAN buttons simultaneously will override the timeguard for 1cycle. 3.11.3 Cycle Timer In normal cooling (and heating) operation the thermostat will notallow more than4 equipment cycles per hour (or 1 cycle every 15 minutes). Both the “Y” (cooling) and “W”...
Page 42
T-- 2983-18 POWERBOX ASSEMBLY UPPER UNIT 1234 21 12 34 1 2 3 4 5 1 2 L N2 N1 W Y GH GL C TBY GH GL R C COOL (Compressor) FAN (High) FAN (Low) 12VDC LowVoltage Power Supply CEILING UNITFURNACE + 12VDC12 VDC (Gnd) Motor Comp. 115V AC High Voltage Power Supply Factory WiringField Wiring THERMOSTAT J Blue Blue Figure 3-41 Wall Thermostat Wiring Diagram -- Heat/Cool Model
Page 43
T-- 298 4-1 SECTION 4 WIRING SCHEMATICS 4.1 INTRODUCTION This Section contains wiring schematics for the AirV units. Figure 4-- 1 is the schematic for the standard upper unit assembly and it is applicable to all standard units. Figure 4-- 2 is the schematic for the Low Profile upper unit assembly. Figure 4-- 3 is the schematic for a free blow ceiling unit without heat while Figure 4-- 4 is a free blow unit with heat. Figure 4-- 5 is for a ducted unit with microprocessor control. Figure 4-- 6 is for an...
Page 44
T-- 2984-2 2P GRN/YELORNWHT WHT ASM PLUG CONNECTS TO UPPER UNIT. SEE DIAGRAM SUPPLIED WITH UPPER UNIT FOR ADDITIONAL WIRING. 4P 2P 1 1 2 3 4 2 { ASWO (OFF) I(ON)2 2--1 SWITCH POSITIONCONTACTS MADE HIGH FAN LOW FAN OFF LOW COOL1--4 . 1--6 1--2 . 1--6 NONE 1--2 . 1--6 . 1--8 1--4 . 1--6 . 1--8 HIGH COOL ASM : AIR SWEEP MOTOR ASW : AIR SWEEP SWITCH SW : SWITCH IT : INDOOR THERMOSTAT LEGEND ORNBLU BLK ORN SWIT ASW 21 CL 8 6 12 4 YEL BLK WHT YEL 12 GRN/YEL11 5 VA C SUPPLY WIRE Figure 4--3 Ceiling Unit...
Page 45
T-- 298 4-3 CONTROL BOXEVAP. RVC 2P 4P 2P2P4P CF H BLK BLU BLK BLU WHT WHT BRN BLK BLK BLK(BLU) GRN/YEL GRN/YELGRN/YEL WHT WHT WHT BRN BRN 1 (3)2 CAPACITOR YEL REDRED OLP (IF USED) BLUBLU RED PTC COMPRESSOR R C S FREEZE SWITCHFA N M O TO R 1 2 3 4 1 2 1 21 2 3 41 2 3 4 1 21 2 OLP: OVERLOAD PROTECTION PTC: START THERMISTER RVC: REVERSING VALVE COIL PLUG CONNECTS TO CEILING UNIT. SEE DIAGRAM SUPPLIED WITH CEILING UNIT FOR ADDITIONAL WIRING. Figure 4--6 Heat Pump -- Upper Unit -- Free Blow PLUG CONNECTS TO...
Page 46
T-- 2984-4 LEGEND RVCPLUG CONNECTS TO CEILING UNIT. SEE DIAGRAM SUPPLIED WITH CEILING UNIT FOR ADDITIONAL WIRING. CN CN CF H OLP :OVERLOAD PROTECTORPTC :START THERMISTOR RVC :REVERSING VALVE COILCN :HOUSING CONNECTOR ODA Th :OUTDOOR AIR THERMISTOR ODC Th :OUTDOOR COIL THERMISTORBLK BLK BLK(BLU) CONTROL BOXEVAP. BLU RED RED BRN BLU WHT GRN/YELGRN/YEL WHT WHT BLK BRN BRN 1 (3)2 CAPACITOR YEL YEL RED OLP (IF USED) BLUBLU RED PTC COMPRESSOR R C S FAN MOTOR ODC Th ODA Th 1 2 3 1 2 3 4 1 2 1 21 2 3 5 6 Figure...
Page 47
T-- 298 4-5 Figure 4--10 Ceiling Unit -- Wall Thermostat -- Ducted & Free Blow 4.2 WALL MOUNTED THERMOSTATS For proper wiring of Wall Mounted Thermostats as an accessory, refer to Figure 3-40 (Wall Thermostat Wiring Diagram -- Cool Only Model) or Figure 3-41 (Wall Thermostat Wiring Diagram -- Heat/Cool Model).
Page 48
Index -1T-- 298 INDEX A Air Handling System , 3-8 Air Sweep Removal, 3-3 Air Sweep Switch , 3-2 C Capacitor Testing, 3-9 Capacitor Testing and Replacement, 3-9 Ceiling Grill -- Ducted, 3-4 Ceiling Grill -- Free Blow, 3-1 Ceiling Panel -- Free Blow, 3-2 CEILING UNIT -- DUCTED SYSTEMS, 3-4 CEILING UNIT -- FREE BLOW , 3-1 Cleaning, 3-1 Compressor , 3-6, 3-13 Condenser Fan, 3-7 Control Box -- Ducted, 3-4 Control Box -- Upper Unit, 3-6 Controls, 3-1 Cool Only Thermostat, 3-15 D Design Change, 1-1 E Evaporator...
Page 49
©2006 Carrier CorporationDPrinted in U. S. A. 0606 Carrier Transport Air Conditioning 50 Grumbacher Road York PA 17402 USA Tel: 1 --800 --673 --2431 Fax: 1 --717 --764 --0401 A member of the United Technologies Corporation family. Stock symbol UTX Carrier Transicold Division, Carrier Corporation Transport Air Conditioning Group P.O. Box 4805 Syracuse, N.Y. 13221 U.S A www.carrier.transicold.com