Page 11
T-- 2981-2 Table 1-1. Model Chart UPPER UNIT (ROOF) Model NumberPart NumberVo l t a g eAmpsColor 11 5VStandard System99-- 00468-- 00115/1/6012.8White115VStandardSystem68RV14102A99-- 00468-- 01115/1/6012.8Ivory 220VStandard System99-- 00468-- 02220/1/505.3 CoolWhite220VStandardSystem68RV11302A99-- 00468-- 03220/1/50 5.3Cool6.7 HeatIvory HighCapacity99-- 00468-- 08115/1/6014.5WhiteHighCapacity68RV15102A99-- 00468-- 09115/1/6014.5Ivory 99-- 00468-- 04 (Free Blow)115/1/6012.7 Cool 10.9 HeatWhite Heat...
Page 12
T-- 298 1-3 Table 1-2 Additional Support Manuals MANUAL -- FORM NO. EQUIPMENT COVEREDTYPE OF MANUAL(For)PART NO. 71LC6A54310AirV 115 Volts-- Free Blow (Cool Only)Owner’s Guide99-- 00469-- 00 99-- 00469-- 01 71LH6A54070AirV 115 Volts-- Free Blow (Heat-- Cool)Owner’s Guide99-- 00469-- 02 99-- 00469-- 03 71LD6A54070AirV 115 Volts-- Ducted (Cool Only)Owner’s Guide99-- 00469-- 06 71LH6A54070AirV 220 Volts-- Free Blow (Heat-- Cool)Owner’s Guide99-- 00469-- 08 99-- 00469-- 09 71RQ6A5401AAirV 115 Volts-- Free...
Page 13
T-- 2981-4 1 2 3 4 1. Ceiling Panel Assembly 2. Control Box Cover3. Control Assembly 4. Ceiling Grill Assembly Figure 1-3 Ceiling Unit Component Identification (Free--Blow)
Page 14
T-- 298 1-5 1 2 3 4 5 6 87 9 10 11 1. Cover Assembly 2. Scroll Assembly -- Upper 3. Condenser Fan 4. Condenser Motor 5. Evaporator Motor 6. Evaporator Blower Wheel7. Condenser Coil 8. Scroll Assembly -- Lower 9. Evaporator Coil 10. Compressor 11. Base Pan Assembly See Figure 1-3 for Ceiling Package (Free-- Blow) Figure 1-4 Component Identification -- Low Profile -- Upper Unit
Page 15
T-- 2981-6 1 2 3 4 5 6 7 89 10 11 12 1. Telescoping Divider (3 different sizes available) 2. Divider Assembly 3. Frame Panel, Insulation Assembly 4. Control Box Assembly 5. Control Box Cover 6. Suction Packing Assembly7. Remote Control Assembly 8. Remote Control Bracket Assembly 9. Filter Assemblies (2) 10. PCB Cover 11. PCB Main Assembly 12. PCB Display Figure 1-5 Component Listing--Ceiling Unit For Ducted Systems
Page 16
T-- 298 1-7 1 2 3 4 5 SCHEMATIC VIEW INSTALLED VIEW 3 2 1 1 4 5 SUPPLY AIR RETURN AIR SUPPLY AIR 1. Vehicle Duct System (Connection) 2. Telescoping Divider (3 different sizes available) 3. Return Air Suction Area4. Control Box Assembly 5. Supply Air Discharge Area Figure 1-6 Ducted System Air Flow Arrangement
Page 17
T-- 2981-8 Serial Number of Ceiling Unit Serial number of Upper Unit Upper Unit Ceiling Unit (Cover Removed) Free Blow Type Bottom View After Installation (With Grille Removed) Ceiling Assembly Frame Serial Number of Ceiling Unit (Side of Control Box) Bottom of Upper Unit Serial Number of Upper Unit Ducted Type Figure 1-7 Serial Number Locations
Page 18
T-- 298 1-9 1.4 AirV SYSTEM COMPONENT SPECIFI- CATIONS 1.4.1 Refrigerant Charge Standard -- High Capacity -- Heat Pump R-- 22 -- 15.9 Ounces Low Profile (All) R-- 22 -- 16.9 Ounces 1.4.2 Compressor -- 115 Volts, 60 Cycles, 1 Phase a. Locked Rotor Amps -- Standard -- High Capacity -- Heat Pump 64.5 AMPS6 b. Locked Rotor Amps -- Low Profile High Capacity 59.0 AMPS c. Fully Loaded Amps -- Standard Cooling -- Approximate 12.8 AMPS Heating -- N/Ad. Fully Loaded Amps -- High Capacity Cooling -- Approx. 14.5...
Page 19
T-- 2981-10 1.7 REFRIGERANT CYCLE -- HEAT PUMP STRAINER OUTDOOR COIL INDOOR COIL REVERSING VALVE ACCUMULATOR COMPRESSORCAPILLARY TUBE DISCHARGE SUCTION LIQUID Figure 1-9 Refrigerant Flow Schematic -- Heat Pump -- (Cool Mode) 1.7.1 Cooling The coolingcycle is energized when the thermostat, located in the ceiling unit,calls for cooling Thesystem controls are positioned for “normal” refrigerant flow, with the compressor discharge delivered to the outdoor coil and liquid delivered to the indoor coil. (See...
Page 20
T-- 298 1-11 COMPRESSORACCUMULATORREVERSING VALVEINDOOR COIL OUTDOOR COIL STRAINER CAPILLARY TUBEDISCHARGE SUCTION LIQUID Figure 1-10 Refrigerant Flow Schematic -- Heat Pump -- (Heat Mode) 1.7.2 Heating The heatingcycle is energized when the thermostat, located in the ceiling unit, calls forheat Thesystem controls are positioned for “reverse” refrigerant flow, with the compressor discharge delivered to the indoor coil and liquid delivered to the outdoor coil. (See Figure 1-10.) The main components of the...