T-- 2981-2 Table 1-1. Model Chart
UPPER UNIT (ROOF)
Model NumberPart NumberVo l t a g eAmpsColor
11 5VStandard System99-- 00468-- 00115/1/6012.8White115VStandardSystem68RV14102A99-- 00468-- 01115/1/6012.8Ivory
220VStandard System99-- 00468-- 02220/1/505.3 CoolWhite220VStandardSystem68RV11302A99-- 00468-- 03220/1/50
5.3Cool6.7 HeatIvory
HighCapacity99-- 00468-- 08115/1/6014.5WhiteHighCapacity68RV15102A99-- 00468-- 09115/1/6014.5Ivory
99-- 00468-- 04
(Free Blow)115/1/6012.7 Cool
10.9 HeatWhite
Heat...

Page 12

T-- 298 1-3 Table 1-2 Additional Support Manuals
MANUAL -- FORM NO.
EQUIPMENT COVEREDTYPE OF MANUAL(For)PART NO.
71LC6A54310AirV 115 Volts-- Free Blow (Cool Only)Owner’s Guide99-- 00469-- 00
99-- 00469-- 01
71LH6A54070AirV 115 Volts-- Free Blow (Heat-- Cool)Owner’s Guide99-- 00469-- 02
99-- 00469-- 03
71LD6A54070AirV 115 Volts-- Ducted (Cool Only)Owner’s Guide99-- 00469-- 06
71LH6A54070AirV 220 Volts-- Free Blow (Heat-- Cool)Owner’s Guide99-- 00469-- 08
99-- 00469-- 09
71RQ6A5401AAirV 115 Volts-- Free...

Page 13

T-- 2981-4
1
2
3
4
1. Ceiling Panel Assembly
2. Control Box Cover3. Control Assembly
4. Ceiling Grill Assembly
Figure 1-3 Ceiling Unit Component Identification (Free--Blow) 

Page 14

T-- 298 1-5
1
2
3
4
5
6
87 9
10
11
1. Cover Assembly
2. Scroll Assembly -- Upper
3. Condenser Fan
4. Condenser Motor
5. Evaporator Motor
6. Evaporator Blower Wheel7. Condenser Coil
8. Scroll Assembly -- Lower
9. Evaporator Coil
10. Compressor
11. Base Pan Assembly
See Figure 1-3 for Ceiling Package (Free-- Blow)
Figure 1-4 Component Identification -- Low Profile -- Upper Unit 

Page 15

T-- 2981-6
1
2
3
4
5
6
7
89 10 11 12
1. Telescoping Divider (3 different sizes available)
2. Divider Assembly
3. Frame Panel, Insulation Assembly
4. Control Box Assembly
5. Control Box Cover
6. Suction Packing Assembly7. Remote Control Assembly
8. Remote Control Bracket Assembly
9. Filter Assemblies (2)
10. PCB Cover
11. PCB Main Assembly
12. PCB Display
Figure 1-5 Component Listing--Ceiling Unit For Ducted Systems 

Page 16

T-- 298 1-7
1
2
3
4
5
SCHEMATIC VIEW
INSTALLED VIEW
3
2
1
1
4 5
SUPPLY AIR
RETURN AIR SUPPLY AIR
1. Vehicle Duct System (Connection)
2. Telescoping Divider (3 different sizes available)
3. Return Air Suction Area4. Control Box Assembly
5. Supply Air Discharge Area
Figure 1-6 Ducted System Air Flow Arrangement 

Page 17

T-- 2981-8
Serial Number
of Ceiling Unit
Serial number
of Upper Unit
Upper Unit
Ceiling Unit
(Cover Removed)
Free Blow Type
Bottom View After Installation
(With Grille Removed)
Ceiling Assembly Frame
Serial Number of
Ceiling Unit
(Side of Control Box)
Bottom of
Upper Unit
Serial Number
of Upper Unit
Ducted Type
Figure 1-7 Serial Number Locations 

Page 18

T-- 298 1-9 1.4 AirV SYSTEM COMPONENT SPECIFI-
CATIONS
1.4.1 Refrigerant Charge
Standard -- High Capacity -- Heat Pump
R-- 22 -- 15.9 Ounces
Low Profile (All)
R-- 22 -- 16.9 Ounces
1.4.2 Compressor -- 115 Volts, 60 Cycles, 1 Phase
a. Locked Rotor Amps -- Standard -- High
Capacity -- Heat Pump
64.5 AMPS6
b. Locked Rotor Amps -- Low Profile
High Capacity
59.0 AMPS
c. Fully Loaded Amps -- Standard
Cooling -- Approximate 12.8 AMPS
Heating -- N/Ad. Fully Loaded Amps -- High Capacity
Cooling -- Approx. 14.5...

Page 19

T-- 2981-10 1.7 REFRIGERANT CYCLE -- HEAT PUMP
STRAINER
OUTDOOR COIL INDOOR COIL
REVERSING VALVE
ACCUMULATOR
COMPRESSORCAPILLARY
TUBE
DISCHARGE
SUCTION LIQUID
Figure 1-9 Refrigerant Flow Schematic -- Heat Pump -- (Cool Mode)
1.7.1 Cooling
The coolingcycle is energized when the thermostat,
located in the ceiling unit,calls for cooling Thesystem
controls are positioned for “normal” refrigerant flow, with
the compressor discharge delivered to the outdoor coil
and liquid delivered to the indoor coil. (See...

Page 20

T-- 298 1-11
COMPRESSORACCUMULATORREVERSING VALVEINDOOR COIL
OUTDOOR COIL
STRAINER
CAPILLARY
TUBEDISCHARGE
SUCTION LIQUID
Figure 1-10 Refrigerant Flow Schematic -- Heat Pump -- (Heat Mode)
1.7.2 Heating
The heatingcycle is energized when the thermostat,
located in the ceiling unit, calls forheat Thesystem
controls are positioned for “reverse” refrigerant flow,
with the compressor discharge delivered to the indoor
coil and liquid delivered to the outdoor coil. (See
Figure 1-10.)
The main components of the...