T-- 298 3-17 3.11.2 Timeguard Timer A 3-- minute timeguard is built into the thermostat immediately upon power up, and any time the compressor (output “Y”) turns off. The compressor will not turn on until the timeguard has expired. Pressing UP and FAN buttons simultaneously will override the timeguard for 1cycle. 3.11.3 Cycle Timer In normal cooling (and heating) operation the thermostat will notallow more than4 equipment cycles per hour (or 1 cycle every 15 minutes). Both the “Y” (cooling) and “W” (heating) outputs have a 15-- minute timer that starts counting down when the output is turned on, (e.g., if “Y” output is turned on for 9 minutes and then satisfies, it cannout turn back on for another 6minutes regardless of demand). However, pressing UP and FAN buttons simultaneously or changing the set point will override the timer for 1 cycle. 3.11.4 Minimum On Timer Once the equipment has turned on, it will remain on for a minimum of 2 minutes regardless of demand. However, the equipment can turn off in less than 2 minutes if a change in set point, or a changein mode occurs. 3.11.5 Error Messages E4 will be displayed if the thermostat has an internal memory failure. If E4 appears, replace the thermostat. -- -- (two dashes) will be displayed if the thermostat cannot properly read the room temperature. If -- -- appears, replace the thermostat. POWERBOX ASSEMBLY UPPER UNIT 1234 2 1 12 34 1 2 3 4 5L N2 N1 W Y GH GL C Y GH GL R CCOOL (Compressor) FAN (High) FAN (Low) 12VDC LowVoltage Power Supply CEILING UNIT Motor Comp. Factory WiringField Wiring THERMOSTAT J 115V AC High Voltage Power Supply Figure 3-40 Wall Thermostat Wiring Diagram -- Cool Only Model
T-- 2983-18 POWERBOX ASSEMBLY UPPER UNIT 1234 21 12 34 1 2 3 4 5 1 2 L N2 N1 W Y GH GL C TBY GH GL R C COOL (Compressor) FAN (High) FAN (Low) 12VDC LowVoltage Power Supply CEILING UNITFURNACE + 12VDC12 VDC (Gnd) Motor Comp. 115V AC High Voltage Power Supply Factory WiringField Wiring THERMOSTAT J Blue Blue Figure 3-41 Wall Thermostat Wiring Diagram -- Heat/Cool Model
T-- 298 4-1 SECTION 4 WIRING SCHEMATICS 4.1 INTRODUCTION This Section contains wiring schematics for the AirV units. Figure 4-- 1 is the schematic for the standard upper unit assembly and it is applicable to all standard units. Figure 4-- 2 is the schematic for the Low Profile upper unit assembly. Figure 4-- 3 is the schematic for a free blow ceiling unit without heat while Figure 4-- 4 is a free blow unit with heat. Figure 4-- 5 is for a ducted unit with microprocessor control. Figure 4-- 6 is for an Upper Unit Heat Pump with free blow application and Figure 4-- 7 is the matching free blow ceiling unit. Figure 4-- 8 is for the Upper Unit Heat Pump ducted application and Figure 4-- 9 is the matching ducted ceiling unit. Note that the ducted units have 115 VAC power for the components and 12 VDC power for the microprocessor control system. Figure 4-- 10 is for the ducted or free blow application that uses a wall-- mounted thermostat, with or without the furnace option. Where applicable, diagrams that designate 115 Volt, 60 H, 1 Phase, are also available using 220 Volts, 50 H, 1 Phase. Most noteably Figure 4-- 1 and Figure 4-- 5. 4P 2P 2P CF H 1 11 22 3 4 2 BLK BLU BLK BLU WHT WHT GRN/YEL CONTROL BOXEVAP. GRN/YELGRN/YEL WHTBRN 12 CAPACITOR YEL YEL RED BLU COMPRESSOR R C S FAN MOTOR OVERLOAD PROTECTOR RED PTCBLU PLUG CONNECTS TO CEILING UNIT SEE FIG> 4-- 3 OR 4 -- 4 (If Used) Figure 4--1 Upper Unit Schematic -- Standard & HC 4P 2P4P CF H BLK BLU BLK BLU WHT GRN/YELGRN/YEL WHT WHT WHT BRNBRN 1 (3)2CAPACITOR YELRED OLP (IF USED) BLUBLU RED COMPRESSOR R C S 1 2 3 4 1 21 2 3 41 2 3 4 OLP: OVERLOAD PROTECTION PTC: START THERMISTER JTB: JOINT TERMINAL BLOCK FMC: INDOOR FAN MOTOR CAPACITOR PLUG CONNECTS TO CEILING UNIT. SEE DIAGRAM SUPPLIED WITH CEILING UNIT FOR ADDITIONAL WIRING. INDOOR FAN MOTOR YEL WHT YEL1 2 31 2 3 WHT 3PYEL BRN FMC YEL WHT BRN OUTDOOR FAN MOTOR PTC (IF USED)LEGEND (UNIT -- 99 -- 00468 -- 10) Figure 4--2 Upper Unit Schematic -- Low Profile
T-- 2984-2 2P GRN/YELORNWHT WHT ASM PLUG CONNECTS TO UPPER UNIT. SEE DIAGRAM SUPPLIED WITH UPPER UNIT FOR ADDITIONAL WIRING. 4P 2P 1 1 2 3 4 2 { ASWO (OFF) I(ON)2 2--1 SWITCH POSITIONCONTACTS MADE HIGH FAN LOW FAN OFF LOW COOL1--4 . 1--6 1--2 . 1--6 NONE 1--2 . 1--6 . 1--8 1--4 . 1--6 . 1--8 HIGH COOL ASM : AIR SWEEP MOTOR ASW : AIR SWEEP SWITCH SW : SWITCH IT : INDOOR THERMOSTAT LEGEND ORNBLU BLK ORN SWIT ASW 21 CL 8 6 12 4 YEL BLK WHT YEL 12 GRN/YEL11 5 VA C SUPPLY WIRE Figure 4--3 Ceiling Unit Schematic -- Cooling Only 2P CEC2P PLUG CONNECTS TO UPPER UNIT. SEE DIAGRAM SUPPLIED WITH UPPER UNIT FOR ADDITIONAL WIRING. GRN/YEL GRN/YEL 4P 2P 2 1 2 3 4 1{ ASWO (OFF) 1(ON)22--1 SWITCH POSITION CONTACTS MADE OFF LOW FAN HIGH FAN LOW COOLNONE L1--L . L1--A L1--H . L1--A L2--C . L1--L . L1--A . B--3 L2--C . L1--H . L1--A . B--3 L2--HT.L1--L.L1--A.B--1 HIGH COOL HEAT ASM AIR SWEEP MOTOR ASW AIR SWEEP SWITCH SW SWITCH CEC CLOSED END CONNECTOR BT BIMETAL IT INDOOR THERMOSTATLEGEND ORNBLU BLK ORN ORNWHT WHT ASM HEATER-- ASSY SW IT ASW 21 11 32 1 L2B 3 C HT A L1L H YEL BLK BLK REDYEL BLU BLK BLK WHT WHT WHT WHTHEATER BT 1 12 2 11 5 VA C SUPPLY WIRE Figure 4--4 Ceiling Unit Schematic -- Heat/Cool 1 2 2 21 3 1 1 1Y L N1 N2 2 34 12 4 3 2 (--) (+) BLK BLKWHT BLU BLK GRN/YEL GRN/YELWHT WHT BLU BLUBLK RED 24 CN9 CN9 135786 CN1 CN4 CN4 CN1 CN2CN3 RY1 RY2 D1 RY3 RY4250V 3.15AFUSE 11 2 3 4 5 6 7 7 65 432 RA Th BRNBLKIDC Th 24 135786 8 1 7 65 4 3 2 88 DISPLAY PCB AS 11 2 3 321 3 2 CONTROL PCB ASS’Y LEGEND IDC Th : INDOoR COIL THERMISTER RA Th : ROOM AIR THERMISTER KY : RELAY DI:DIODE 115 VAC POWER 12 VDC POWER Figure 4--5 Ceiling Unit, Standard -- Ducted
T-- 298 4-3 CONTROL BOXEVAP. RVC 2P 4P 2P2P4P CF H BLK BLU BLK BLU WHT WHT BRN BLK BLK BLK(BLU) GRN/YEL GRN/YELGRN/YEL WHT WHT WHT BRN BRN 1 (3)2 CAPACITOR YEL REDRED OLP (IF USED) BLUBLU RED PTC COMPRESSOR R C S FREEZE SWITCHFA N M O TO R 1 2 3 4 1 2 1 21 2 3 41 2 3 4 1 21 2 OLP: OVERLOAD PROTECTION PTC: START THERMISTER RVC: REVERSING VALVE COIL PLUG CONNECTS TO CEILING UNIT. SEE DIAGRAM SUPPLIED WITH CEILING UNIT FOR ADDITIONAL WIRING. Figure 4--6 Heat Pump -- Upper Unit -- Free Blow PLUG CONNECTS TO UPPER UNIT. SEE DIAGRAM SUPPLIED WITH UPPER UNIT FOR ADDITIONALWIRING. HEATER AS HEATER BTGRN/YEL GRN/YEL4P 2P 2P 2P2P { ORN WHT BRN BLK WHT REDYELBLUBLK ORN ORNWHT WHT BLK ASM SW ITASW 21 1 C L H 2 B L2 3 3 C 1 HTA L1L H YEL BLKBLK BLK CEC WHT WHTSWITCH POSITIONCONTACTS MADE OFF LOW FAN HIGH FAN LOW COOL HIGH COOL HEATINGNONE L1--L . L1--A L2--HT.L1--L.L1--A.B--1L2--C . L1--H . L1--A . B--3 L2--C . L1--L . L1--A . B--3 L1--H . L1--A ASWO (OFF) 1(ON)2 2--1 LEGEND 1 2 3 4 1 2 1 2 1 12 2 112 2 ASM: AIR SWEEP MOTOR ASW: AIR SWEEP SWITCH SW: SWITCH IT: INDOOR THERMOSTAT CEC: CLOSED END CONNECTOR BT: BIMETAL 11 5 VA C SUPPLY WIRE Figure 4--7 Heat Pump -- Ceiling Unit -- Free Blow
T-- 2984-4 LEGEND RVCPLUG CONNECTS TO CEILING UNIT. SEE DIAGRAM SUPPLIED WITH CEILING UNIT FOR ADDITIONAL WIRING. CN CN CF H OLP :OVERLOAD PROTECTORPTC :START THERMISTOR RVC :REVERSING VALVE COILCN :HOUSING CONNECTOR ODA Th :OUTDOOR AIR THERMISTOR ODC Th :OUTDOOR COIL THERMISTORBLK BLK BLK(BLU) CONTROL BOXEVAP. BLU RED RED BRN BLU WHT GRN/YELGRN/YEL WHT WHT BLK BRN BRN 1 (3)2 CAPACITOR YEL YEL RED OLP (IF USED) BLUBLU RED PTC COMPRESSOR R C S FAN MOTOR ODC Th ODA Th 1 2 3 1 2 3 4 1 2 1 21 2 3 5 6 Figure 4--8 Heat Pump -- Upper Unit -- Ducted ODC ODA RVC MOTORCOMPRESSOR FUSED1 250V 3.15A 3 3 332 1 7 6 5 4 3 2 1 11 22 33 44 55 66 7 8 8 87 1 1 1 2 2 2 1 2 3 4 FURNACE SIGNAL 12VDC POWER(--) (+) 115VAC POWER BLK WHT BLK BLK GRN/YEL RED BLU BLK RED BRN GRN/YEL WHT BLK WHT BLUBLU BLUBLK RED PLUG CONNECTS TO UPPER UNIT. SEE DIAGRAM SUPPLIED WITH UPPER UNIT FOR ADDITIONAL WIRING. ODA Th :OUTDOOR AIR THERMISTOR * * *FACTORY WIRING (12VDC LOW VOLT.) (115VACHIGHVOLT.) FIELD WIRING FIELD WIRING LEGEND NOTE CONTROL PCB POWER PCB ASS’Y ASS’Y 2 24 4 CN9 DISPLAY PCB AS CN91 13 3576 5788 6 CN1 CN6 CN5 CN6 CN4 CN4 CN1 CN2CN3 CN5 K1 K4 K3 K7 K2 K61 1 1 1 2 2 2 2 2 1 3 3 3441 22 1 Y L N2 N1 12 RA Th BRN BLK IDC Th IDC Th: INDOOR COIL THERMISTER RA Th: ROOM AIR THERMISTER ODC Th: OUTDOOR COIL THERMISTER RVC: REVERSING VALVE COIL D1: DIODE K: RELAY Figure 4--9 Heat Pump -- Ceiling Unit -- Ducted
T-- 298 4-5 Figure 4--10 Ceiling Unit -- Wall Thermostat -- Ducted & Free Blow 4.2 WALL MOUNTED THERMOSTATS For proper wiring of Wall Mounted Thermostats as an accessory, refer to Figure 3-40 (Wall Thermostat Wiring Diagram -- Cool Only Model) or Figure 3-41 (Wall Thermostat Wiring Diagram -- Heat/Cool Model).
Index -1T-- 298 INDEX A Air Handling System , 3-8 Air Sweep Removal, 3-3 Air Sweep Switch , 3-2 C Capacitor Testing, 3-9 Capacitor Testing and Replacement, 3-9 Ceiling Grill -- Ducted, 3-4 Ceiling Grill -- Free Blow, 3-1 Ceiling Panel -- Free Blow, 3-2 CEILING UNIT -- DUCTED SYSTEMS, 3-4 CEILING UNIT -- FREE BLOW , 3-1 Cleaning, 3-1 Compressor , 3-6, 3-13 Condenser Fan, 3-7 Control Box -- Ducted, 3-4 Control Box -- Upper Unit, 3-6 Controls, 3-1 Cool Only Thermostat, 3-15 D Design Change, 1-1 E Evaporator Blower Wheel, 3-8 Exterior Cover, 3-5, 3-10, 3-15 F Filter Removal -- Free Blow, 3-1 Filter Removal -- Ducted, 3-4 Fuse Removal -- Ducted, 3-5 H Heat Strip, 3-3 Heat/Cool Thermostat, 3-15 I Indoor Thermostat , 3-3 INTRODUCTION, 1-1, 4-1 L LCD DISPLAY, 3-15, 3-16 Leaks, 3-1 M Main Pcb Board, 3-5 Master Control Switch, 3-2 Motor , 3-7 Mounting, 3-1 P Painting, 3-1 PCB Display , 3-5 PREVENTATIVE MAINTENANCE, 3-1 R REFRIGERANT CYCLE, 1-9, 1-10 S Serial Number, 1-1 SERVICE -- GENERAL, 3-1 SERVICE -- UPPER UNIT -- LOW PROFILE, 3-10 SERVICE AND MAINTENANCE, 3-1 START--UP, 1-9 T THERMOSTAT INSTALLATION AND START--UP IN- STRUCTIONS (WALL MOUNTED), 3-15 TROUBLESHOOTING, 2-1, 2-3 U Upper Scroll Assembly, 3-7, 3-10, 3-11, 3-12, 3-13 W WIRING SCHEMATICS, 4-1
©2006 Carrier CorporationDPrinted in U. S. A. 0606 Carrier Transport Air Conditioning 50 Grumbacher Road York PA 17402 USA Tel: 1 --800 --673 --2431 Fax: 1 --717 --764 --0401 A member of the United Technologies Corporation family. Stock symbol UTX Carrier Transicold Division, Carrier Corporation Transport Air Conditioning Group P.O. Box 4805 Syracuse, N.Y. 13221 U.S A www.carrier.transicold.com