40MVC / 38MVC 40MVQ / 38MVQ Service Manual High --- Wall Duct Free Split System Sizes 009 To 024 TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS 1......................... STANDARD FEATURES AND ACCESSORIES 2........... SPECIFICATIONS -- COOLING ONLY 3.................. SPECIFICATIONS -- HEAT PUMP UNITS 4............... DIMENSIONS 5...................................... SERVICE VALVE LOCATIONS 5........................ CLEARANCES 6..................................... SYSTEM OPERATING ENVELOPE...
Page 2
2 MODEL NUMBER NOMENCLATURE OUTDOOR UNIT 38 MVC 3 --- 01 --- 018 A i r --- C o o l e d C o n d e n s e r Unit Type MVC--- C o o l i n g O n l y MVQ--- H e a t P u m pVo ltage 1--- 1 1 5 --- 1 --- 6 0 3--- 208/230 --- 1 --- 60 Nominal Capacity 009--- 3 / 4 T o n 012--- 1 T o n 018--- 1 --- 1 / 2 T o n 024--- 2 T o n s INDOOR UNIT 40 MVC 3 --- 01 --- 018 Fan Coil Unit Unit Type MVC--- C o o l i n g O n l y MVQ--- H e a t P u m pVo ltage ------ 3 0 V D C 1--- 1 1 5 --- 1 --- 6 0 3--- 208/230 --- 1 --- 60...
Page 3
3 STANDARD FEATURES AND ACCESSORIES Ease Of Installation Mounting BracketsS Low Voltage ControlsS Comfort Features Microprocessor ControlsS Wireless Remote ControlS Automatic Air SweepS Air Direction ControlS Auto Restart FunctionS Cold Blow Protection On Heat PumpsS Tu r b o M o d e O n S i z e s 9 K a n d 1 2 KS Auto Changeover On Heat PumpsS Energy Saving Features Sleep ModeS Stop/Start TimerS Safety And Reliability 3MinuteTimeDelayForCompressorS Over Current Protection For CompressorS Indoor Coil...
Page 4
4 SPECIFICATIONS -- COOLING ONLY UNITS System System Model Number5 3 M V C 0 0 9 --- --- --- 15 3 M V C 0 1 2 --- --- --- 15 3 M V C 0 1 2 --- --- --- 35 3 M V C 0 1 8 --- --- --- 3 System Voltage115 V115 V208/230208/230 Control Voltage0 --- 1 2 P u l s e D C0 --- 1 2 P u l s e D C0 --- 1 2 P u l s e D CPulse DC Capacity (Btuh)9000120001200018000 SEER13.013.013.013.0 Refrigerant Refrigerant TypeR --- 410A Design Pressure (PSIG)550550550550 Metering DeviceCapillary Tube in Outdoor Unit Charge...
Page 5
5 SPECIFICATIONS -- HEAT PUMP UNITS System System Model Number5 3 M V Q 0 0 9 --- --- --- 15 3 M V Q 0 1 2 --- --- --- 15 3 M V Q 0 1 2 --- --- --- 35 3 M V Q 0 1 8 --- --- --- 3 System Voltage115 V115 V208/230208/230 Control Voltage0 --- 1 2 P u l s e D C0 --- 1 2 P u l s e D C0 --- 1 2 P u l s e D CPulse DC Capacity (Btuh)9000120001200018000 SEER13.013.013.013.0 HSPF7.77.77.77.7 Refrigerant Refrigerant TypeR --- 410A Design Pressure (PSIG)550550550550 Metering DeviceCapillary Tubes in Outdoor Unit...
Page 6
6 DIMENSIONS -- INDOOR A07336 Model SizeW in. (mm)H in. (mm)D in. (mm)Weight lb (kg) 9K32.09 (815)11.02 (280)7.68 (195)24.2 (11) 12K35.67 (906)11.26 (286)9.25 (235)33.0 (15)18K49.21 (1250)12.80 (325)9.06 (230)55.0 (25) 24K49.21 (1250)12.80 (325)9.06 (230)55.0 (25) DIMENSIONS -- OUTDOOR L1 L2 35 W H Air Flow L3 A07337 Model SizeW in. (mm)H in. (mm)L1 in. (mm)L2 in. (mm)L3 in. (mm)Weight lb (kg) Cooling OnlyWeight lb (kg) Heat Pumps 9K30.71 (780)21.26 (540)21.61 (549)11.81 (300)10.87 (276)77.0 (35)79.2...
Page 7
7 CLEARANCES -- INDOOR 6 (0.15m) min. 5 (0.13m) min. 6 5 (0.13m) min. (1.8m) A07891 Fig. 2 – Indoor unit clearance CLEARANCES -- OUTDOOR A DB Air-outlet Air-inlet C E A07894 UNIT9k and 12k in. (mm)18k and 24k in. (mm)A24 (610)24 (610)B24 (610)36 (914)C24 (610)24 (610)D4 (102)12 (305)E12 (305)12 (305) Fig. 3 – Outdoor Unit Clearance 38/40MVC, MVQ
Page 8
8 SYSTEM OPERATING ENVELOPE 53MVC/MVQ System Operating Envelope Chart 40 50 60 70 80 90 100 110 120 -10 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 Outdoor Temperature (ºF) Indoor Temperature (ºF) 0 5 10 15 20 25 30 35 40 45 50 55 60 -40-35-30-25-20-15-10-5 0 5 1015202530354045505560 Outdoor Temperature (ºC) Indoor Temperature (ºC) Cooling Continuous Operation Heating Continuous Operation 85º F 62ºF 55º75ºF 55ºF 5ºF 80ºF 125º Use low ambient control if the unit will operate...
Page 9
9 WIRING The main power is supplied to the outdoor unit. The field supplied connecting cable from the outdoor unit to indoor unit consists of four wires and provides the power for the indoor unit as well as the communication signal between the outdoor unit and indoor unit. Voltage drop on the connecting cable should be kept to a minimum. Use cable size and max length below: 18 AWG50 ft. (16 m) 16 AWG100 ft. (33 m) CONNECTION DIAGRAMS CONNECTING CABLE CONNECTING CABLECONNECTING CABLE CONTROL CONTROL...
Page 10
10 WIRING DIAGRAMS Fig. 6 – Wiring Diagram 38MVC009-- -- --1 W/ 40MVC009-- -- --1 38/40MVC, MVQ