21 Connecting the Power Cord Connect the power cord. Make sure to use only the power cord provided with the scanner. WARNING When connecting the power cord, follow these precautions. Failure to do so may cause a fire or electrical shock. •Never grasp the power plug when your hands are wet. •Never plug the scanner into a multiplug power strip. •Never bundle or tie the power cord around itself or another object. Connect the power plug securely into the power outlet. •Use only the power cord and power plug provided with the scanner. •Before you connect the power cord, make sure to turn OFF the power switch.•Connect only to a power outlet of the rated voltage and power supply frequency (either 120 V, 60 Hz or 220-240 V, 50/60 Hz, depending on your region). •Do not plug the scanner into a power outlet shared with another device. If you use an extension cord, make sure that the extension cord is rated for the current requirements of the scanner. Follow the procedures below to turn the scanner power ON and OFF. Turning ON the Power ATo turn ON the scanner, press the Power Switch to the “ ” position. IMPORTANT •When you turn ON the power, the power LED lights and remains lit. •If the scanner does not work, or the power LED continues to flash, there is a problem with the scanner. Turn OFF the power, and contact your local authorized Canon dealer or service representative to have the scanner serviced. WARNING If you hear strange sounds, detect smoke or abnormal heat, sense a vibration, or smell odd odors around the scanner, turn OFF the power immediately and disconnect the power cord from the power outlet. Contact your local authorized Canon dealer or service representative to have the scanner serviced. Turning ON and OFF the Power
22 BTurn ON your computer. CWindows recognizes the CR-135i II/CR-190i II as new hardware, and installation starts automatically. NOTE The CR-135i II/CR-190i II will be registered as “CANON CR-135i USB” or “CANON CR-190i USB” in the Imaging Device directory. Turning OFF the Power ATurn OFF your computer. BTo turn OFF the scanner, press the Power Switch to the “ ” position. CAUTION •Wait at least 10 seconds before turning the scanner back ON. •For your safety, disconnect the power plug from the power outlet if you are not using the scanner for a long period of time. (Windows Vista)
23 This section describes how to prepare the ink cartridge so that you can use the imprinter to print text or a bitmap on scanned documents. About the Ink CartridgeThe ink cartridge is not included with the scanner. Purchase an ink cartridge separately, as shown below. Compatible ink cartridges: IMPORTANT These ink cartridges are available for 5 years after production has stopped. Setting the Ink Cartridge and Adjusting the Print Position The ink cartridge needs to be set to print. Set the ink cartridge according to the following procedure. You can adjust the print position to two different levels. IMPORTANT •To set the ink cartridge, turn the scanner OFF before removing the Top Cover. After the ink cartridge is set, replace the Top Cover, and then turn the scanner back ON. •Finish up the unpacked ink cartridge as soon as possible. More frequent cleaning of the ink cartridge is required if long time elapses after unpacking. ARemove the Top Cover. BSqueeze the Print Position Adjustment Lever, and push it down to the bottom position. Preparing the Ink Cartridge Region Canon Ink Cartridge North America/ South AmericaPG-145/ 145XL, 245/ 245XL EU PG-445/ 445XL, 545/ 545XL Asia/ Oceania PG-645/ 645XL, 745/ 745XL
24 CPlace the ink cartridge shown in the diagram below. CAUTION Do not touch the electrical contact on the carriage. Doing so may cause a malfunction. NOTE Do not use more than one cartridge by rotation. If you do so, applications cannot check the ink level precisely. DPush down the ink cartridge until it clicks into place. IMPORTANT Make sure that the ink cartridge is securely in place. ESqueeze the Print Position Adjustment Lever and move it to adjust the print position. FCarefully replace the Top Cover. Top: 51.5 mm (2.03) from the bottom edge of the document Bottom: 31.5mm (1.24) from the bottom edge of the document
25 Software This chapter describes how to use the Scanning Utility and the Ranger. This section describes how to start up the Scanning Utility so that you can use the scanner. Read the Help files for the Scanning Utility for information on how to use it. How to Use the Scanning Utility This section describes the procedure for using the Scanning Utility. Read the [Help] file in [Scanning Utility] for more information. AClick [Start], and then click [All Programs]. BClick [Scanning Utility for CR-135i/CR-190i]. CStart the Scanning Utility. NOTE The basic operation of the Scanning Utility is noted in the Scanning Utility help file. On the [Help] menu, click [Help] to view the explanation. How to Use the Software
26 DSelect [Scanner Setting] from the [File] menu. The Settings dialog box appears. ESet the scan conditions and click [OK]. NOTE For information about the settings for the scan conditions, click [Help] on the Settings dialog box to open the Help file. FSelect the scanning method from the [File] menu and start scanning. GWhen scanning is finished, click [Exit] on the [File] menu to quit the Scanning Utility.
27 How to Use the Ranger About the RangerSilver Bullet Technology’s Ranger Transport API software, allowing it to be easily integrated into existing systems or be mixed and matched with a wide range of leading check processing software. Installing the RangerFollow the instructions below to install the Ranger. ATurn ON your computer, and start Windows. IMPORTANT Be sure to log on as the administrator. BInsert the setup disc into the Disc drive.This manual assumes that “D” is assigned to your Disc drive. CClick [Start], and then click [All Programs].The procedure in Windows XP/7/8/8.1/10 is different from the ones described in this manual. Refer to the Windows XP/7/8/8.1/ 10 “Help and Support Center” to select [Run]. DClick [Accessories], and then click [Run].
28 EEnter “D:\Ranger\setup.exe” in the [Open] field, and then click [OK]. Installation starts. FFollow the instructions on the screen to complete the installation. IMPORTANT The computer may need to be restarted, after the installation, depending on the operating system. If this is necessary, make sure to restart the computer. This section describes how to uninstall the Scanning Utility and the Ranger. IMPORTANT •Be sure to log on as the Administrator. •The procedure in Windows XP/Vista/7/8/8.1/10 is different from the ones described in this manual. Refer to the Windows XP/Vista/7/8/8.1/10 “Help and Support Center” to uninstall the software. AClick [Start], and then click [Control Panel]. Uninstalling the Software
29 BDouble-click the [Programs and Features] icon. The [Programs and Features] dialog box appears. CSelect the software that you want to remove from the list in the dialog box, and then click [Uninstall]. NOTE When the [User Account Control] dialog box appears, click [Continue]. IMPORTANT •If you uninstall the “Scanning Utility for CR-135i/CR-190i” you also need to uninstall the “Canon Driver for CR-135i/CR-190i.” •If you uninstall the Ranger, select the “Ranger for CR-135i/CR-190i.” DThe [Confirm File Deletion] dialog box appears. If you selected “Canon Driver for CR-135i/CR-190i,” the above dialog box appears. EClick [Yes], and the uninstaller starts.Follow the instructions on the screen to finish uninstalling the software.
30 Document Feeding and Scanning This chapter describes precautions regarding documents that can be handled on this scanner and scanning operations. This section describes the types of documents that can be used and how to place them. CAUTION Treat the documents carefully. The paper edges may cut your fingers. DocumentThe CR-135i II/CR-190i II can feed a wide variety of document sizes. The ranges of height and length for a document are: Height : 68 to 108 mm (2.7 to 4.3) Length : 120 to 245 mm (4.7 to 9.6) Thickness : 0.08 to 0.20 mm (0.003 to 0.008) Weight : 64 to 157 g/m 2 (17 to 40 lb bond)Follow these guidelines when you prepare a document for scanning: Before scanning documents that contain pasted artwork, make sure that the ink or paste is thoroughly dry. If the documents are scanned with wet ink or paste, the inside of the scanner may become dirty and it may cause a malfunction. If you scan a document written in pencil, the letters may not be scanned properly or the pencil may rub off onto the rollers and stain subsequent documents. Before you scan this kind of document, make a copy, and then scan the copy. After scanning a document written in pencil or some other soft writing material, be sure to clean the scanning rollers. (See “Cleaning the Scanning Glass and Rollers,” on p. 45.) If you scan thin paper in the Duplex mode, the ink printed on the back side may be scanned. If this happens, adjust the scanning density. Scanning documents with a rough surface may not feed easily, and may cause friction between the documents, resulting in a feeding error. If this happens, feed the documents one by one. To avoid paper jams, damage to documents, and a scanner malfunction, do not feed the following types of paper into the scanner. If you want to scan these types of paper, first make a copy, and then scan the copy. Documents Length Height