171 Installation Manual Connecting to a Networ k Network Settings on the Projector From the projector menus screen, network settings can be configured in the [Network Setting] tab. For the menu operations, refer to page 88. (The screen is for the WUX5000 / WUX4000.)Locking the Network Settings You can lock / unlock the network settings so that they cannot be changed and cancel the lock. MENU > [Network Setting] > [Network Setting lock] After the OK button is pressed to accept your setting and the MENU button or the EXIT button (WUX6000 / SX6000) is pressed to close the window, the lock is re-engaged. If you change the network settings, be sure to continue operating without closing the window. [Lock] is the factory default. For the default network password, refer to page 173. UnlockCancels the lock and allows other network settings to be changed. The password must be entered in order to cancel the lock. When [Unlock] is selected, the window shown below appears. Use the [] / [] / [] / [] but- tons to enter the 4-digit pass- word. For the WX6000 / SX6000, num- bers can be entered using the numerical buttons on the remote control. LockLock the settings.
Network Settings on the Projector 172 Turning the Network Function On / Off You can turn the projector network function on or off. Power can be saved by turning the function [Off]. MENU > [Network Setting] > [Network function] Press the OK button to accept your setting and then press the MENU button or EXIT button (WX6000 / SX6000). [Off] is the factory default. Forcibly canceling the network lockIn the Network Password Input screen, press the buttons in the following sequence to cancel the lock: [ ] [OK] [ ] [OK] [ ] [OK]. This will reset the network password to [ ] [ ] [ ] [ ]. OffDisables the network function. OnEnables the network function.
173 Network Settings on the Projector Installation Manual Connecting to a Networ k Setting a Network Password You can set whether or not a password is required in order to change the projector network settings. MENU > [Network Setting] > [Network Pass- word setting] Press the OK button to accept your setting and then press the MENU button or EXIT button (WX6000 / SX6000). [On] is the factory default. Registering a Network Pass- word Register the projector network password. MENU > [Network Setting] > [Register Network Password] When [Register Network Password] is selected, the window shown below appears. Enter a 4 digit password. For the WUX5000 / WUX4000, the pass- word can be entered using the [ ] / [ ] / [ ] / [ ] buttons. For the WX6000 / SX6000, the password can be entered using a combination of the numerical but- tons and the [ ] / [ ] / [ ] / [ ] buttons. [ ] / [1], [ ] / [2], [ ] / [3], and [ ] / [4] have the same function. Press the OK button to accept your setting and then press the MENU button or EXIT button (WX6000 / SX6000). The factory default is [ ] [ ] [ ] [ ] (WUX5000 / WUX4000) or [1] [1] [1] [1] (WX6000 / SX6000). OffA network password is not used. OnA network password is used.
Network Settings on the Projector 174 Turning the PJLink Function On / Off You can turn the PJLink network function on or off. When the function is turned on, control is possible via the LAN using com- mands that meet PJLink standards. MENU > [Network Setting] > [PJLink] Press the OK button to accept your setting and then press the MENU button or EXIT button (WX6000 / SX6000). [On] is the factory default. This projector conforms to Class 1 as defined in the PJLink standards of the JBMIA (Japan Business Machine and Information System Industries Associa- tion). This projector supports all com- mands that are defined by PJLink Class 1, and has been verified as conforming to the PJLink standard Class 1 definition. For information about using PJLink, refer to page 187. OffDisables the PJLink function. OnEnables the PJLink function. What is PJLink? In September 2003, the PJLink Work- ing Group was established under the Data Projector Committee. During the first year, this PJLink Working Group standardized PJLink as a new inter- face specification for projectors. PJLink is a unified standard for opera- tion and control of projectors. It allows centralized control of projec- tors and operation from a controller for all projectors regardless of manufac- turer. The objective is for JBMIA to improve convenience for users and expand the use of projectors through early systemization for network monitoring and control of projectors, which will become the mainstream in the future. Class 1: Standardization of control and monitoring specifications for basic projector functions Basic projector control: Power control, input selection, etc. Acquisition of projector information and status: Power status, input selec- tion status, error status, lamp use time, etc. JBMIA: Japan Business Machine and Information System Industries Association The Japan Business Machine and Information System Industries Association is an organization which was launched in 1960 and changed its name on April 1, 2002. PJLink is a registered trademark of JBMIA and pending trademark in some countries.
175 Network Settings on the Projector Installation Manual Connecting to a Networ k Turning DHCP Function On / Off You can turn the projector DHCP function on or off. MENU > [Network Setting] > [DHCP] Press the OK button to accept your setting and then press the MENU button or EXIT button (WX6000 / SX6000). [Off] is the factory default. TCP / IP Setting Configure the projector TCP / IP settings. MENU > [Network Setting] > [TCP/IP setting] When [TCP/IP setting] is selected, the win- dow shown below appears. Use the [] / [ ] buttons to select the IP address, then press the OK button. Next, use the [ ] / [ ] buttons to select the digit and the [] / [ ] buttons to change the value. For the WX6000 / SX6000, numbers can be entered using the numerical buttons on the remote control. Press the OK button, then set the subnet mask and gateway address in the same way. Finally, select [Enter]. The factory defaults are shown below. IP address 192.168.254.254 Subnet mask 255.255.255.0 Gateway address 0.0.0.0 Settings cannot be made when [DHCP] (P175) is [On]. If an invalid value is entered, the message “Invalid entry” appears. If this occurs, enter a valid value. OffDisables the DHCP function. TCP / IP settings are possible. OnEnables the DHCP function. Searches the DHCP server . Because the IP address is acquired from the DHCP server, it is not necessary to enter the TCP / IP settings (IP address, subnet mask, gateway address).
Network Settings on the Projector 176 Initializing Network Settings You can initialize the projector network set- tings. MENU > [Network Setting] > [Network setting initialization] When [Network setting initialization] is selected, the window shown below appears. Select [YES] then press the OK button. The following items are initialized. Network setting screen user name, various settings including password Network Password setting Register Network Password PJLink DHCP IP address Subnet mask Gateway address E-mail sender address E-mail recipient address Projector name Location
177 Installation Manual Connecting to a Networ k Configuring the Network From the Computer ■Displaying and Configuring the Network Configuration Screen The web browser screen shown below is for the WUX4000. 1Turn on the computer and projector. 2Launch a web browser, enter “http://(projector IP address)” in the address bar, and press the Enter key. The password input screen appears. 3Enter the user name and password on the password input screen, then click OK. The factory default user name is “root” and the password is “system”. The projector web screen appears in the web browser. The factory default IP address is “192.168.254.254”. If DHCP settings are used, ask the net- work administrator for the projector IP address. It is possible to check the IP address from the projector menu.
Configuring the Network From the Computer 178 The following information is displayed. *1 WUX5000 / WX6000 / SX6000 *2 WUX4000 4To configure, click [Settings]. The settings window appears. Projector name The name of the projector on the network Location The location of projector installation MAC address The MAC address of the projector IP address The IP address of the projector Power Status The power status of the projector Lamp Time *1 Lamp operating time Lamp Time Normal Mode *2 Lamp operating time in [Normal] lamp mode Lamp Time Quiet Mode *2 Lamp operating time in [Quiet] lamp mode Lamp Time Converted *2 Lamp operating time (converted value) Filter Time Air filter operating time Alert Error message (if an error has occurred) Temperature abnormality Faulty lamp Faulty lamp cover Faulty cooling fan Faulty power supply Faulty lens connector: Lens connector error Faulty air filter unit: Air filter error Unknown error To operate the projector from the computer, click [Projector control] ( P188).
179 Configuring the Network From the Computer Installation Manual Connecting to a Networ k 5Select the function to set from the menu (1), then enter the setting in the displayed field (2) and click [OK] (3). 6A confirmation window appears. Check the contents and if they are correct, click [Apply]. The settings are applied to the projector and “Save completed” is displayed. 7Click [Back to top] to return the web screen to the initial page. (2) (1) (3)
Configuring the Network From the Computer 180 ■Resetting to Factory Defaults 1Perform steps 1 - 3 on page 177 to display the setting window. 2Click [Initialize]. 3A confirmation window appears. Click [OK]. ■Setting Errors When a setting-related error occurs, the error name is displayed on the screen, and a “!” mark is displayed next to the input field which caused the error.