Page 61
3-21 Basic Settings Setting User Access Privileges (Access Control) You can perform the following settings with Access Control. ● Authorized User Account: Register users who may connect to the VB-C50i/V\ B-C50iR. ●Authorized/Restricted Host Specification: Control whether a specific hos\ t is to have access or not. When you have made changes to the settings, click the “OK” button \ to return to the Settings Title Page. If you do not make any changes, click the “Cance\ l” button. Authorized User Account 1...
Page 62
3-22 Authorized/Restricted Host Specification Note ●If you do not make a Host List, access is permitted to any hosts. ● If the Host List provided prohibits access for all hosts, the Host Restr\ iction function is disabled and access is permitted to all hosts. ● To prohibit access over HTTP connection via a proxy server, the address \ of the proxy server must be set. ● When you set a host list which leads to prohibit yourself, restore the f\ actory default settings. Setting User Access Privileges (Access...
Page 63
3-23 Basic Settings Tip The Host Restriction function applies to hosts running client applicatio\ ns such as viewer. Access restrictions are imposed using a list made up of one or m\ ore entries written using the format described below. Listing Format [!] addr [-addr2] ●“addr” is written in standard IP address format. ● Because the IP addresses in the “addr” and “addr2” parameter\ s define the range of IP addresses, if an IP address A is higher than “addr” and lowe\ r than “addr2”, A is included in the...
Page 64
3-24 Setting the Date and Time (Date and Time) You can perform the following settings with Date and Time. ●Current Camera Time: Displays the time set up for the camera. ● New Camera Time: For setting up the time on the VB-C50i/VB-C50iR. ● Time Zone: Select the appropriate time zone from the list. When you have made changes to the settings, click the “OK” button \ to return to the Settings Title Page. If you do not make any changes, click the “Cance\ l” button. Current Camera Time 1 “Date” and “Time”...
Page 65
3-25 Basic Settings New Camera Time 1“Synchronize with computer time” Set to the date and time of the PC currently accessing the VB-C50i/VB-C5\ 0iR via a Web browser. 2 “Set manually” Select this item when the date and time are to be manually entered. In t\ he Date field, enter the year, month and day in yyyy-mm-dd format; in the Time field, enter the t\ ime in hh:mm:ss 24- hour format. For example, for January 23, 2004, 1:23:04 p.m., enter “2004/01/23”\ and “13:23:04”. 3 “Synchronize with NTP server”...
Page 66
3-26 You can perform the following settings with Miscellaneous. ●DNS: Register the Name Server Address and Host Name for registering host\ names such as Mail Server Host. ● Mail: For setting up the mail addresses which are to receive recorded pi\ ctures and log messages. ● External Device Names: For setting up the names for the external devices\ to be used with VK-64 etc. ● LED: For setting the LED on the VB-C50i/VB-C50iR to turn on or off. When you have made changes to the settings, click the “OK”...
Page 67
3-27 Basic Settings Mail 1“Mail Server Host” Specify the SMTP server. 2 “Sender’s (From) Mail Address” Specify the mail sender. 3 “Recipient (To) Mail Address” Specify the mail recipient. 4 “POP before SMTP” Select if the mail host server requires POP user authentication. 5 “User Name” and “Password” Specify the settings in “User Name” and “Password” necessary\ for authentication. 6 “POP Server” Specify the POP server. 1 3 5 2 4 6 Setting Up Name Server Address and Mail etc. (Miscellaneous)...
Page 68
3-28 External Device Names 1“External Input Device 1-2” “Device Name” To distinguish between the different external devices connected to the M\ ulti-Terminal Module, be sure to enter a device name. Enter a device name consisting of up to \ 15 alphanumeric characters. 2 “External Output Device 1-3” “Device Name” To distinguish between the different external devices connected to the M\ ulti-Terminal Module, be sure to enter a device name. Enter a device name consisting of up to \ 15 alphanumeric...
Page 69
3-29 Basic Settings You can use the following items with the Administration Tools. ● On-board File System Information: Displays the status of VB-C50i/VB-C50i\ R’s memory. ●Recorded Picture and Audio data* Information and Manipulation: Displays the status of pictures and audio* recorded in the VB-C50i/VB-C50iR and deletes recorded pictures and audio*. * Only available with two particular models ( → P.iii) ●Miscellaneous: Confirm settings for the VB-C50i/VB-C50iR and initializat\ ion. If you do not...
Page 70
3-30 Miscellaneous 1“View Log Events” Click the “View” button to see the historical log files of the VB-\ C50i/VB-C50iR’s operation, such as connection with viewers, etc. 2 “View Current Settings” Display a list of current settings. 3 “Reboot” Reboot the VB-C50i/VB-C50iR. 4 “Restore Settings” All but the password setting, Ethernet address setting, IP address, subn\ et mask and default gateway of the VB-C50i/VB-C50iR will be restored to the factory default \ settings. Click “Restore”- “OK” buttons and...