    							81
    2Pull the OPEN lever and pull open the front unit toward 
    you.
    3Use compressed air to remove dust and paper particles 
    from the inside of the scanner.
    4Wipe any dirt off the scanning glass.
    Wipe any dirt off the scanning glass with a cloth that has been 
    dampened with water and thoroughly wrung out, and then wipe 
    the glass dry with a clean, dry and soft cloth.
    CAUTION
    Do not spray water or neutral detergent directly on the scanner. 
    Precision mechanisms, such as the light source, may get wet, 
    and cause a malfunction.
    IMPORTANT
     Scratches on the sensor glass may cause marks on the images, 
    as well as feeding errors. If there are scratches on the sensor 
    glass, contact your local authorized Canon dealer or service 
    representative.
     Take care to ensure the anti-static brush in the front unit does 
    not become deformed.
    Scanning Glass
     
    						
    							82
    5Clean the rollers.
    Clean the rollers while turning them.
    Wipe the rollers with a cloth that has been dampened with water 
    and thoroughly wrung out, and then use a clean, dry and soft cloth 
    to wipe away any moisture.
    6Remove the retard roller and feed roller. (See p. 86, p. 87)
    IMPORTANT
    Remove the retard roller and feed roller from the scanner to clean 
    them, and be sure to reattach them to the scanner when cleaning 
    is finished.
    7Wipe the removed rollers with a cloth that has been 
    dampened with water and thoroughly wrung out.
    8Reattach the retard roller and feeding roller. (See p. 86, 
    p. 87)
    Anti-Static brush
    Rollers
     
    						
    							83
    9Close the front unit by gently pushing it up on both sides 
    until it clicks into place. Make sure that the front unit is 
    completely closed by pushing until you hear a click.
    10Close the document eject tray.
    Adjusting the Reduction Ratio
    As the rollers installed in the scanner wear out, scanned images may 
    become stretched in the vertical direction. If this happens, you can 
    reduce the amount of stretching of the image by adjusting the 
    reduction ratio.
    IMPORTANT
    Log on to Windows as an Administrator.
    1Click the Start button, and then click [All Programs], 
    [Canon DR-M160], and [Canon imageFORMULA Utility].
    imageFORMULA Utility starts.
    Hint
    In Windows 8.1/8, it is registered at the following location.
     
    						
    							84
    2Click [Canon DR-M160 USB] and click [Properties].
    Scanner properties are displayed.
    3Click the [Maintenance] tab and then change the value of 
    [Reduction ratio adjustment].
    The adjustment value can be set within the range from -3.0% to 
    3.0%.
    4Click [OK] to close the scanner properties.
    1Opens the scanner drivers Detail Settings screen. (See 
    p. 47)
    2Click   to display the [Scanner Information] dialog box.
    3Click [Maintenance] to display the [Maintenance] dialog 
    box.
    4Change the value of [Reduction ratio adjustment].
    The adjustment value can be set within the range from -3.0% to 
    3.0%.
    5Click   to close the dialog box. 
     
    						
    							85
    Replacing Consumable Parts
    The two rollers (feed roller and retard roller) installed in the scanner 
    are consumable parts. The feed roller and retard roller wear with 
    scanning. If the feed roller and retard roller are worn, documents may 
    not feed correctly and paper jams and double feeds may occur.
    When more than 200,000 pages have been fed (total number of pages 
    fed by the scanner), a message prompting you to replace the rollers is 
    displayed when the computer is started.
    If this message begins to be displayed at startup, purchase an 
    exchange roller kit and replace the worn parts with the consumable 
    parts included in the kit (feed roller and retard roller). See p. 102 for 
    details about the exchange roller kit.
    Furthermore, the counter in the scanner that records the number of 
    pages fed also needs to be reset when you replace the rollers. (See 
    p. 88)
    Hint
    Even before it becomes time to replace the rollers, scanned images 
    may become stretched in the vertical direction due to wear of the 
    rollers. If this happens, adjust the reduction ratio. (See p. 83)
    Opening and Closing the Front Unit
    1Open the document eject tray.
    2Pull the OPEN lever and pull open the front unit toward 
    you.
     
    						
    							86
    Hint
    The location of each of the consumable parts is shown below.
    3When closing the front unit, make sure that it is 
    completely closed by gently pressing the left and right 
    until you hear a click.
    4Close the document eject tray.
    Replacing the Feed Roller
    1Open the roller cover.Retard roller (inside 
    the front unit) Feed Roller
     
    						
    							87
    2Remove the feed roller.
    3Install the new feed roller.
    4Close the roller cover.
    Replacing the Retard Roller
    1Open the roller cover.
    2Pull the left lever that secures the retard roller to the 
    scanner, and remove the roller.
    ▼
     
    						
    							88
    3Install the new retard roller by inserting the right side 
    first.
    4Push the left side of the retard roller to secure it to the 
    scanner.
    5Close the roller cover.
    Resetting the counter
    IMPORTANT
    Log on to Windows as an Administrator.
    1Click the Start button, and then click [All Programs], 
    [Canon DR-M160], and [Canon imageFORMULA Utility].
    imageFORMULA Utility starts.
    Hint
    In Windows 8.1/8, it is registered at the following location.
     
    						
    							89
    2Click [Canon DR-M160 USB] and click [Properties].
    Scanner properties are displayed.
    3Click the [Maintenance] tab and then select [Reset].
    The counter for [Current Rollers] resets.
    4Click [OK] to close the scanner properties.
    1Opens the scanner drivers Detail Settings screen. (See 
    p. 47)
    2Click   to display the [Scanner Information] dialog box.
    3Click [Maintenance] to display the [Maintenance] dialog 
    box.
    4Click [Reset].
    5Click   to close the dialog box. 
     
    						
    							90
    Auto Power Off Setting
    The scanner automatically turns off if 4 hours elapse without scanning 
    or another operation being performed.
    To disable this setting, follow the procedure below.
    IMPORTANT
    Log on to Windows as an Administrator.
    1Click the Start button, and then click [All Programs], 
    [Canon DR-M160], and [Canon imageFORMULA Utility].
    imageFORMULA Utility starts.
    Hint
    In Windows 8.1/8, it is registered at the following location.
    2Click [Canon DR-M160 USB] and click [Properties].
    Scanner properties are displayed.
    3Click the [Maintenance] tab and then clear the [Turn off 
    automatically after 4 hours] check box.
     
    						