Page 111
Custom Function Settings 111 Remarks Page This makes it easier to change the aperture during studio sessions with studio flash units. Also, when AEB is used in the manual exposure mode, the shutter speed can be fixed while only the aperture is shifted for AE\ B. If you are using a super telephoto lens with more than one EOS-3 body, you can still set the aperture with the camera(s) not attached to the \ lens. This function is mainly for pro photographer assistants. Same as setting 2. • To use this Custom...
Page 112
112 Custom Function No. Setting Description Exposure setting increments Electronic manual focusing. Frame counter displayCF-6 CF-7 CF-80 1 2 0 1 2 0 1Enables all settings to be set in 1/3-stop increments. Enables the shutter speed and aperture to be set in full-stop increments, and exposure compensation and flash exposure compensation in 1/3-stop increments. Enables all exposure settings to be set in half-stop increments. The lenses listed on the right enable electronic manual focusing after AF...
Page 113
Custom Function Settings 113 Remarks Page This is suited for slide films which have a narrow exposure latitude. The shutter speed and aperture can be set in the familiar full-stop increments. Suited for negative films which have a wide exposure latitude. EF 50mm f/1.0L USM, EF 85mm f/1.2L USM, EF 200mm f/1.8L USM, EF 300mm f/2.8L USM, EF 400mm f/2.8L USM, EF 400mm f/2.8L II USM, EF 500mm f/4.5L USM, EF 600mm f/4L USM, EF 1200mm f/5.6L USM, EF 28-80mm f/2.8-4L USM. This prevents the focus from being...
Page 114
114 Custom Function No. Setting Description AEB sequence and cancellation Focusing point flashing modeCF-9CF-10 0 1 2 3 0 1 2 3standard exposure, underexposure, overexposure, then automatic cancellation. standard exposure, underexposure, overexposure, and no automatic cancellation. Underexposure, standard exposure, overexposure, then automatic cancellation. Underexposure, standard exposure, overexposure, and no automatic cancellation. Standard mode • Flashes when focus is achieved, lights dimly while you...
Page 115
Custom Function Settings 115 Remarks Page AEB is not canceled even when the lens is interchanged or when the film is replaced. Therefore you can keep taking AEB shots (with the standard\ exposure first). You can keep taking AEB shots in this sequence. This applies during manual focusing point selection and Eye-Control AF. During automatic focusing point selection, the focusing point does not light dimly after focus is achieved. If the flashing of the focusing point is annoying, you can disable it. This...
Page 116
116 Custom Function No. Setting Description Focusing point selection method Mirror lockup CF-11 CF-12 0 1 2 3 0 1Enables the focusing point to be selected by pressing the < > button and turning the < > dial and/or < > dial. • Turn the < > dial to select a focusing point on the right or left, and turn the < > dial to select a focusing point on the top or bottom. Enables the focusing point to be selected by pressing the < > button and turning the < > dial and/or < > dial. Enables the < > dial alone to...
Page 117
Custom Function Settings 117 Remarks Page The functions of the < > button and < > button are reversed. This makes the exposure compensation method and aperture setting method (during manual exposure) the same as with the EOS-1. This setting is identical to the EOS-1N’s Custom Function CF-11 set t\ o 2 for the left or right focusing point selection method. With this setting\ , you can select the focusing point while pressing the shutter button halfway \ (or within ( )after releasing the shutter button) or...
Page 118
118 Custom Function No. Setting Description Focusing point and spot metering linkage Automatic reduction of fill-in flash output Shutter curtain synchronization CF-13 CF-14 CF-15 0 1 2 0 1 0 1No linkage. • Spot metering is always at the center. Links spot metering to the focusing point. • Spot metering is linked to one of 11 focusing points selected either manually or by Eye Control. No linkage. • Spot metering is always at the center. • You can select only one of 11 focusing points. Enable. Disable....
Page 119
Custom Function Settings 119 Remarks Page The selectable focusing points are limited to 11. This makes focusing point selection faster and links spot metering to the focusing point you\ select. This setting is effective for spotlighted subjects on-stage, etc\ ., when you want to maintain the framing of the subject. Compared to setting 0, this setting makes focusing point selection faste\ r. (When automatic focusing point selection is used with settings 1 and 2,\ all 45 focusing points will be subject...
Page 120
120 Custom Function No. Setting Description Safety shift Manual focusing point selection range CF-16 CF-17 0 1 0 1 2Disabled. Enabled. • Safety shift works in the shutter speed- priority AE and aperture-priority AE modes. • If a standard exposure cannot be obtained with the shutter speed or aperture you have set, then the camera automatically shifts the shutter speed or aperture so that a standard exposure can be obtained. Standard Expanded selection range Automatically-selected range 08. C836-E (103~)...