Page 41
6 720 644 894 Maintenance and service41 6 Maintenance and service 6.1 Annual maintenance (To remove front cover, see page 7.) Venting System • Venting system - inspect inside of flue pipe for a ny blockage or restriction. Observe burner flames during heater operation. (front cover must be removed). Inspect the combustion air inlet pipe for blockage or debris. Inspect combustion air and exhaust terminations for blockage or debris. Combustion Chamber • Inspect burner...
Page 42
6 720 644 89442 Maintenance and service 5. Disconnect inlet and outlet water pipes from the water heater. Place a small bucket underneath the water heater to catch residual water remaining insi de the water heater. 6. Using an air compressor, blow short bursts of air (100psi max) through the inlet water connection unt il there is no water present coming through the outlet water connection of the heater. 7. Reconnect water fittings and return heater to ser vice when danger of...
Page 43
6 720 644 894 Maintenance and service43 B Remove the condensing heat exchanger unit from the appliance by pulling it towards you. B Dismantle all parts for inspection and cleaning. Fig. 67 Condensing heat exchanger B Check the condensing heat exchanger for any obstruction. B Flush the condensing heat exchanger unit with water . B Check all gasket and o-rings for damage and replace if necessary. B Assemble the condensate unit and all other parts in reverse order of disassembly. 6.5...
Page 44
6 720 644 89444 Maintenance and service Note: When making adjustments, make sure combustion cover is installed. C. Adjusting CO 2: Note: P1 adjustment will change the P2 reading. Confirm the P1 value BEFORE adjusting the P2 level. 1. If P1 CO 2 level is off: B Loosen yellow painted Phillips screw (1) and cover should rotate down (2) revealing a recessed brass slotted screw. Fig. 70. B Turning the slotted screw counter clockwise will raise P1 CO 2 levels and...
Page 45
6 720 644 894 Maintenance and service45 6.6 Program values This section describes details on programming the appliance. For most applications the factory defaul t val- ues will provide robust and stable operation. Only adjust the factory settings if the installation req uires changes as indicated in the appropriate section of this manual. Refer to 6.7 Control board diagnostics (page 35) regarding how to access these P-modes. Caution: Misadjusted program values can lead to appliance...
Page 46
6 720 644 89446 Maintenance and service 6.7 Control board diagnostics 1. Press ON/OFF button to turn off the appliance. 2. Press and hold Program button and press ON/OFF button to turn appliance ON. 3. Release the button when 188 appears on the display. The display should read P2 when the program button is released. If not, repeat process. 4. Press and release the button on the control panel until the display reads P4. You are now in the diagnostic mode of the control board....
Page 47
6 720 644 894 Troubleshooting47 7 Troubleshooting 7.1 Introduction Many of the questions customers ask regarding opera tion of this unit can be answered by following the troubleshooting steps as outlined below. Visit our web site at www.boschpro.com for more detailed troubleshooti ng. For best results, perform each step before proceedi ng to the next. The suggested solutions may require that the cover be taken off. (See Page 7. Fig. 3). 7.2 Burner does not ignite when hot...
Page 48
6 720 644 89448 Troubleshooting and check all taps for water flow. There should be no water flowing. Any continuous flow of water, small or large, indicates a crossover and must be corrected. Consult a professional plumber for help in correcti ng a crossover. Failing single lever faucet mixing valve s are common causes of plumbing crossovers. 8.Ensure the temperature sensor is making contact and firmly mounted on the hot water pipe. 7.5 Low water flow/pressure 1.Too...
Page 49
6 720 644 894 Problem solving49 8 Problem solving 8.1 Error code diagnostics i To remove error code from the display, press the reset button. DisplayCauseSolution Fault in the flue gas limiter. Temperature above 230 °F (110 °C) inside the cabinet. 1. Check continuity of the flue gas limiter (see Fig. 77, page 57). Go to steps two and three to determine flue gas lim iter fault and repair it. 2. Check for flue gas leakage around the top and bo ttom seals of heat exchanger, use mirror...
Page 50
6 720 644 89450 Problem solving Primary fan rotation too low in operation. 1. Disconnect power supply cord and check wire conn ection on back side of fan and the connectors on the control board, see Fig. 84 , page 65. 2. Check supply voltage. It must be 120VAC and prop erly grounded. 3. Check venting specifications are met. Long vent lengths, venting with more than three elbows, blocked vent o r combination venting may cause this failure. 4. Ensure intake and...