    Have a look at the manual ATT DEFINITY Communications System Generic 3 Planning And Configuration Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 164 ATT manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							SYSTEM PARAMETERSaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
    TABLE C (continued).
    System Parameters
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    Item G1 G3i G3r
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    External CMS
    Measured agents per system 400 400 1,023
    Measured agents per split 30 30 999
    Measured splits 32 99 255
    Measured trunk groups 99 99 666
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    Facility Busy Indicators
    Number of indicators 2,400 4,000 10,000
    Buttons per tracked resource 100 100 100
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    Hunt Groups or Splits
    Groups and/or splits 99 99 255
    With hospitality parameter reduction 5 5 None
    Group members per system 500 500 3,000
    Group members per group/split 200 200 999
    Measured groups/splits 99 99 255
    Queue slots per group 200 200 999
    Queue slots per system 1,000 1,000 6,000
    Announcements per group 2 2 2
    Measured ACD agents
    Agents logged in per system measured by CMS 400 400 1,023
    Agents logged in per split measured by CMS 200 200 999
    ACD supervisors per system 99 99 255
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    Intercom Translation Table (ICOM)
    Automatic/manual and dial
    ICOM groups per system 32 32 680
    Members per ICOM group 32 32 32
    Members per system 1,024 1,024 8,192
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    Last Number Dialed
    Entries per system 2,400 2,400 15,028
    Number of digits 16 16 16
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    Leave Word Calling (SPE based)
    Messages stored 2,000 2,000 2,000
    Messages per user 10 10 16
    Simultaneous message retrievers 60 60 400
    Systemwide message retrievers 10 10 10
    Remote message waiting indicators
    Per extension 80 80 80
    Per system 80 80 500
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb c c c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c c c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c c c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c c c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c c c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    36 
    						
    							aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaSYSTEM PARAMETERS
    TABLE C 
    (continued).
    System Parameters
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    Item G1 G3i G3r
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    Modem Pool Groups
    Mode 2/analog 5 5 63
    Members per group 32 32 32
    Group members per system 160 160 2,016
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    Networking
    CAS nodes 99 99 99
    DCS nodes 63 63 63
    UDP nodes 240 240 1,000
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    Paging
    Loudspeaker zones 9 9 9
    Code calling IDs 125 125 125
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    Personal CO Lines (PCOL)
    PCOL trunk groups 40 40 100
    PCOL lines 40 40 100
    PCOL trunks per trunk group 1 1 1
    PCOL appearances 4 4 16
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    Port Circuit Pack Slots*
    Per PPN
    MCC simplex 89 89 80
    MCC duplicated 78 78 60
    SCC simplex 64 64 None
    SCC duplicated 56 56 None
    Per EPN
    MCC simplex 99 99 99
    MCC duplicated 98 98 98
    SCC simplex 71 71 71
    SCC duplicated 70 70 70
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    Power Failure Extensions
    Model 574-5 panel 35 35
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb c c c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c c c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c c c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c c c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c c c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    *
    Only port slots are included in this count.  There are 100 port slots per EPN cabinet,  one of which is
    dedicated for the Tone/Clock board.  There may be other service-related slots required which would
    further reduce the number of port slots available.  In G3 carriers, a 21
    st slot may be equipped with auxili-
    ary boards that do not require tip and ring connections.
    37 
    						
    							SYSTEM PARAMETERSaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
    TABLE C (continued).
    System Parameters
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    Item G1 G3i G3r
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    Recorded Announcements
    Recorded announcements 64 128 256
    Analog queue slots per system 150 150 300
    Analog queue slots per announcement 150 150 300
    Integrated queue slots per system 50 50 300
    Calls connected per announcement
    Integrated announcement or auxiliary trunk 255 255 255
    Analog trunk 128 128 128
    Integrated announcement circuit packs 1 1 1
    Channels per integrated announcement circuit pack 16 16 16
    Integrated announcement recording time (min.:seconds)
    16 KB recording None 8:32 8:53
    32 KB recording 4:16 256 256
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    Speech Synthesis Circuit Packs 6 6 40
    Channels per speech circuit pack 4 4 4
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    System Administration
    Simultaneous administration sessions 3 5 8
    Simultaneous administration commands 1 1 5
    Simultaneous maintenance commands 1 1 3
    Administration history file entries 250 250 2000
    Printer queue size 50 50 50
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    Terminating Extension Groups (TEGs)
    TEGs 32 32 32
    Users that may share a TEG 4 4 4
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c
    38 
    						
    							aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaSYSTEM PARAMETERS
    TABLE C 
    (continued).
    System Parameters
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    Item G1 G3i G3r
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    Time Slots
    Total slots 1,024 1,536 11,264
    Slots for voice and data 966 1,449 10,604
    Simultaneous circuit-switched calls 482 723 5,291
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    Tone Classifiers
    Tone detector circuit packs 20 10 50
    General purpose tone detectors 40 20 100
    Touch-tone receivers 80 40 200
    Call classifier circuit packs 10 10 25
    Call progress touch-tone receivers (TTR) 80 80 200
    TTR queue size 4 4 4
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    Trunks
    Trunks in system (also remote access) 400 400 4,000
    With hospitality parameter reduction 50 50 None
    Trunk members in a trunk group 99 99 255
    Trunk groups in the system 99 99 666
    Trunk group hourly measurements None None 75
    Queue slots for trunks 198 198 1,332
    Ringback queue slots 120 1000 1,000
    DS1 circuit packs 30 30 166
    PRI Interfaces (D-channels)
    MCC 8 8 166
    SCC 4 4
    PRI Interfaces (B-channels)
    MCC 184 400
    SCC 92 400
    PRI Temporary Signaling Connections 656
    Call associated 400
    Non-call associated 256
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    Voice Terminals
    Stations
    11,600 1,600 10,000
    Associated data modules (DTDMs, etc.) 800 800 5,000
    Digital stations
    21,600 1,600 10,000
    ISDN-BRI stations3None 1,000 5,000
    Station button capacity (units) 547.2 K 547.2 K 4.12 M
    Display Stations 1,600 1,600 10,000
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c
    aaaaaaaaaaaaaaaaaaa
    1.  This includes extensions administered without associated hardware.
    2.  All digital stations can be display stations.
    3.  All ISDN-BRI stations can be display stations.
    39 
    						
    							SYSTEM PARAMETERSaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
    Notes:
    Digital data endpoints terminate on a port of the switch.  Up to 800 ports can ter-
    minate digital data endpoints.  The remaining system  ports are available for terminat-
    ing digital voice terminals, trunks, etc. 1.
    For G3, the extensions are shared among the following applications: voice station,
    attendant,  data endpoint, hunt group, recorded announcement, TEG, VDN, extension
    for failed automatic wakeup messages, attendant common shared extensions, code
    calling ID, and phantom extensions.  (For example, it is possible to have 1600 sta-
    tions plus 1300 phantom extensions, that is, administration without hardware).  In
    addition, there is another internal dial plan limit:  PCOL groups, common shared
    extensions, access endpoints, code calling IDs, Listed Directory Numbers (LDNs),
    hunt groups, announcements, and TEGs are limited to 860. 2.
    When more than 23 B-Channels for every one D-Channel are provisioned, Non-
    Facility Associated Signaling (NFAS) must be used. 3.
    Trunks and access endpoints (see Data Parameters in Table C entries for more on
    access endpoints) consume the same resource.  The sum of trunks and access end-
    points cannot exceed 400. 4.
    A fully equipped PPN cabinet and EPN cabinet without duplication (MCC system)
    has 184 port circuit pack slots available (after tone detectors and expansion inter-
    faces have been added in).  A system using all these slots for digital line circuit packs
    has a maximum physical digital line capacity of 1472 lines (184 slots x 8 ports per
    slot).  Replacing one of the digital line circuit packs with a trunk circuit pack or a cir-
    cuit pack other than a digital line circuit pack reduces the digital line capacity by 8
    lines.  Therefore, trunking and analog and hybrid terminal requirements must be con-
    sidered in determining the actual maximum for each system.  When the second EPN
    is added in a G3 system, 1600 digital terminals can be configured in the system. 5.
    A button module (function key module) is a portion of memory required to store but-
    ton translations.  Some digital voice terminals require no button modules while other
    terminals need one or more modules.  Digital voice terminal button module and
    display requirements are given in the following table, ``Station Allocation Characteris-
    tics.  These button module and display requirements limit the number of digital voice
    terminals with more than 10 feature buttons and/or displays that can be connected to
    a system.  In G3, memory units are allocated by the system to each terminal based
    on the number of buttons actually translated.  The button module scheme is no
    longer used in G3.  There are 547,000 memory units available in G3 for terminals. 6.
    The system automatically initiates phantom user calls without any dialing from a
    voice terminal.  An automatic wakeup call is an example of a phantom user call. 7.
    40 
    						
    							aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaSYSTEM PARAMETERS
    The following table shows the button module requirements of different station configurations.
    TABLE D.  Station Allocation Characteristics
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    Required Records Required Records and
    Station Type
    (G1,G3) Button Units*
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    Analog set 500 S S+62
    Analog set 2500 S S+62
    Analog set 7101A S S+62
    Analog set 8102 S S+62
    Analog set 8110 S S+62
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    10MET set - 10 buttons S S+52
    20MET set - 20 buttons S + [B] S+152
    30MET set - 30 buttons S + [B] S+252
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    Hybrid set - 7303S S S+102
    Hybrid set - 7305S S + [B] S+342
    Hybrid set - 7309S S S+102
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    Digital set - 7401D S S+92
    Digital set - 7401 Plus S S+92
    Digital set - 7403D S S+102
    Digital set - 7404D S + M S+62
    Digital set - 7404D w/display S + B + M S+192
    Digital set - 7405D S + [B] S+342
    Digital set - 7405D w/display S + B + [B] S+472
    Digital set - 7406D S + [B] S+282
    Digital set - 7406D w/display S + B + [B] S+342
    Digital set - 7406 Plus S + [B] S+282
    Digital set - 7407D (w/display) S + B + [B] S+472
    Digital set - 7407 Plus S + B + [B] S+472
    Digital set - 7410D S S+102
    Digital set - 7434D S + [B] S+342
    Digital set - 7434D w/call coverage module S + B + [B] S+542
    Digital set - 7434D w/display S + 2B + [B] S+472
    602A1 S + B + [B] S+342
    PC S + B + [B] S+472
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    510BCT S + B + [B] + M S+322
    515BCT S + B + M S+232
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c
    aaaaaaaaaaaaaaaaaaa
    * 
    Ð Assumes 3 call appearances per station in button 1-3 with all other available buttons assigned.
    Ð For call appearances other than 3, adjust total units by the following:
    adjustment=(Nca-3)*[(10*Ndisp)+(6*Nbri)]
    where: Nca=number of call appearance (assumes first Nca button is CA)
    Ndisp=total number of display stations in system
    Nbri=total number of BRI station in system
    41 
    						
    							SYSTEM PARAMETERSaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
    TABLE D (continued).
    Station Allocation Characteristics
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    Required Records Required Records and
    Station Type
    (G1,G3) Button Units*
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    Basic Attendant Console A + 2B A
    Enhanced Attendant Console A + 2B A
    Attendant Selector Console A + 2B A
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    Feature Module [B] 240
    Display B **
    DTDM M M
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    MPDM/MTDM/7400A/7400B/7500B M M
    Call Coverage Module B 200
    EIA (PI-Simplex) M M
    CDR M M
    Netcon Data Channel 2M 2M
    Processor Interface Link 2M 2M
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    [ISDN sets for G3 only]
    ISDN-BRI UDM - 7500 M + I
    ISDN-BRI set - 7505 S + I + 190
    ISDN-BRI set - 7506 w/display S + I + 250
    ISDN-BRI set - 7507 w/display S + I + 480
    ISDN-BRI set - 8503T S + I + 50
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb c c c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c
    c c c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c c c
    c
    c
    c
    LEGEND:bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    Notation Meaning G1 G3
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    A Attendant record 7 7
    S Basic station record 1600 1600
    B Large button module 1000 2000
    M Data module record 800 800
    I ISDN-BRI endpoint record N/A N/A
    # Button memory units N/A 547200
    bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb c c c
    c
    c
    c c c
    c
    c c c
    c
    c
    c c c
    c
    aaaaaaaaaaaaaaaaaaa
    * 
    Ð Assumes 3 call appearances per station in button 1-3 with all other available buttons assigned.
    Ð For call appearances other than 3, adjust total units by the following:
    adjustment=(Nca-3)*[(10*Ndisp)+(6*Nbri)]
    where: Nca=number of call appearance (assumes first Nca button is CA)
    Ndisp=total number of display stations in system
    Nbri=total number of BRI station in system
    **  For G3, the number of button memory units required for a display depends on the station type.  The number of  button
    memory units required for a display is indicated for each station type in the table above. Note that these values
    depend on the assumptions in the previous footnote.  (Call appearances are only translated on buttons 1-3.)
    42 
    						
    							aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaSYSTEM PARAMETERS
    Notes:
    Regarding station allocation:
    1. For G1, [B] is equivalent to B.  For G3, [B] indicates large button modules that are allo-
    cated only when a button on that module is administered.
    2. Any digital DCP station can add a 7400B, requiring one data module record.
    3. A DTDM can be added to a 7403D or 7405D, requiring one data module record.
    4. The 6504-T is administered as a 7505D and the 6508-T is administered as a 7507D
    (G3 only).
    5. A data module (ADM-T) can be added to a 7505D, 7506D, or 7507D, requiring one data
    module record (G3 only).
    6. The PC/ISDN is administered as a 7506D or 7507D with ADM (G3 only).
    7. An ISDN-BRI endpoint record is required for each distinct ISDN-BRI  endpoint.  Thus
    each voice-only, data-only, or voice-data endpoint uses one of these records.
    43 
    						
    							aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaSYSTEM VERSION DETERMINATION
    SYSTEM VERSION DETERMINATION
    From the information given in Tables A, C, and D, you should now be able to determine the sys-
    tem version needed.  Check the version in one of the boxes provided.
    G1 
    G3i 
    G3r 
    43 
    						
    							aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaHARDWARE AND SOFTWARE DETERMINATION
    HARDWARE AND SOFTWARE DETERMINATION
    Voice/Data Terminal Equipment Assignments
    Use Table E to list the system users and their individual equipment needs. Blank columns are
    provided so that you can fill in the name, extension number, application (voice and/or data), type
    of terminal equipment, and adjunct(s) required for each user.  A current phone directory and sta-
    tion survey may be helpful when filling in this table.
    Note:Before entering the information in Table E, review the 
    DEFINITYÒCommunications
    System Generic 1 and System 75 and System 85ÐTerminals and AdjunctsÐ
    Reference, 
    555-015-201, to strengthen your familiarity with the systems terminals
    and adjuncts.
    Voice/Data Terminal Totals
    Using the information listed in Table C and Table E, complete Tables F and G to summarize your
    terminal and adjunct needs.  As mentioned above, detailed information for each voice terminal
    and adjunct can be found in the 
    DEFINITYÒCommunications System Generic 1 and System 75
    and System 85ÐTerminals and AdjunctsÐReference, 
    555-015-201.
    After completing Tables F and G, complete Table H to ensure that the identified equipment is
    within the maximum limits of the system.
    45 
    						
    All ATT manuals Comments (0)

    Related Manuals for ATT DEFINITY Communications System Generic 3 Planning And Configuration Instructions Manual