Have a look at the manual ATT DEFINITY Communications System Generic 3 Planning And Configuration Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 164 ATT manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
SYSTEM PARAMETERSaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa TABLE C (continued). System Parameters bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Item G1 G3i G3r bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb External CMS Measured agents per system 400 400 1,023 Measured agents per split 30 30 999 Measured splits 32 99 255 Measured trunk groups 99 99 666 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Facility Busy Indicators Number of indicators 2,400 4,000 10,000 Buttons per tracked resource 100 100 100 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Hunt Groups or Splits Groups and/or splits 99 99 255 With hospitality parameter reduction 5 5 None Group members per system 500 500 3,000 Group members per group/split 200 200 999 Measured groups/splits 99 99 255 Queue slots per group 200 200 999 Queue slots per system 1,000 1,000 6,000 Announcements per group 2 2 2 Measured ACD agents Agents logged in per system measured by CMS 400 400 1,023 Agents logged in per split measured by CMS 200 200 999 ACD supervisors per system 99 99 255 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Intercom Translation Table (ICOM) Automatic/manual and dial ICOM groups per system 32 32 680 Members per ICOM group 32 32 32 Members per system 1,024 1,024 8,192 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Last Number Dialed Entries per system 2,400 2,400 15,028 Number of digits 16 16 16 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Leave Word Calling (SPE based) Messages stored 2,000 2,000 2,000 Messages per user 10 10 16 Simultaneous message retrievers 60 60 400 Systemwide message retrievers 10 10 10 Remote message waiting indicators Per extension 80 80 80 Per system 80 80 500 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c 36
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaSYSTEM PARAMETERS TABLE C (continued). System Parameters bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Item G1 G3i G3r bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Modem Pool Groups Mode 2/analog 5 5 63 Members per group 32 32 32 Group members per system 160 160 2,016 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Networking CAS nodes 99 99 99 DCS nodes 63 63 63 UDP nodes 240 240 1,000 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Paging Loudspeaker zones 9 9 9 Code calling IDs 125 125 125 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Personal CO Lines (PCOL) PCOL trunk groups 40 40 100 PCOL lines 40 40 100 PCOL trunks per trunk group 1 1 1 PCOL appearances 4 4 16 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Port Circuit Pack Slots* Per PPN MCC simplex 89 89 80 MCC duplicated 78 78 60 SCC simplex 64 64 None SCC duplicated 56 56 None Per EPN MCC simplex 99 99 99 MCC duplicated 98 98 98 SCC simplex 71 71 71 SCC duplicated 70 70 70 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Power Failure Extensions Model 574-5 panel 35 35 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c * Only port slots are included in this count. There are 100 port slots per EPN cabinet, one of which is dedicated for the Tone/Clock board. There may be other service-related slots required which would further reduce the number of port slots available. In G3 carriers, a 21 st slot may be equipped with auxili- ary boards that do not require tip and ring connections. 37
SYSTEM PARAMETERSaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa TABLE C (continued). System Parameters bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Item G1 G3i G3r bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Recorded Announcements Recorded announcements 64 128 256 Analog queue slots per system 150 150 300 Analog queue slots per announcement 150 150 300 Integrated queue slots per system 50 50 300 Calls connected per announcement Integrated announcement or auxiliary trunk 255 255 255 Analog trunk 128 128 128 Integrated announcement circuit packs 1 1 1 Channels per integrated announcement circuit pack 16 16 16 Integrated announcement recording time (min.:seconds) 16 KB recording None 8:32 8:53 32 KB recording 4:16 256 256 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Speech Synthesis Circuit Packs 6 6 40 Channels per speech circuit pack 4 4 4 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb System Administration Simultaneous administration sessions 3 5 8 Simultaneous administration commands 1 1 5 Simultaneous maintenance commands 1 1 3 Administration history file entries 250 250 2000 Printer queue size 50 50 50 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Terminating Extension Groups (TEGs) TEGs 32 32 32 Users that may share a TEG 4 4 4 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c 38
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaSYSTEM PARAMETERS TABLE C (continued). System Parameters bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Item G1 G3i G3r bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Time Slots Total slots 1,024 1,536 11,264 Slots for voice and data 966 1,449 10,604 Simultaneous circuit-switched calls 482 723 5,291 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Tone Classifiers Tone detector circuit packs 20 10 50 General purpose tone detectors 40 20 100 Touch-tone receivers 80 40 200 Call classifier circuit packs 10 10 25 Call progress touch-tone receivers (TTR) 80 80 200 TTR queue size 4 4 4 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Trunks Trunks in system (also remote access) 400 400 4,000 With hospitality parameter reduction 50 50 None Trunk members in a trunk group 99 99 255 Trunk groups in the system 99 99 666 Trunk group hourly measurements None None 75 Queue slots for trunks 198 198 1,332 Ringback queue slots 120 1000 1,000 DS1 circuit packs 30 30 166 PRI Interfaces (D-channels) MCC 8 8 166 SCC 4 4 PRI Interfaces (B-channels) MCC 184 400 SCC 92 400 PRI Temporary Signaling Connections 656 Call associated 400 Non-call associated 256 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Voice Terminals Stations 11,600 1,600 10,000 Associated data modules (DTDMs, etc.) 800 800 5,000 Digital stations 21,600 1,600 10,000 ISDN-BRI stations3None 1,000 5,000 Station button capacity (units) 547.2 K 547.2 K 4.12 M Display Stations 1,600 1,600 10,000 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c aaaaaaaaaaaaaaaaaaa 1. This includes extensions administered without associated hardware. 2. All digital stations can be display stations. 3. All ISDN-BRI stations can be display stations. 39
SYSTEM PARAMETERSaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa Notes: Digital data endpoints terminate on a port of the switch. Up to 800 ports can ter- minate digital data endpoints. The remaining system ports are available for terminat- ing digital voice terminals, trunks, etc. 1. For G3, the extensions are shared among the following applications: voice station, attendant, data endpoint, hunt group, recorded announcement, TEG, VDN, extension for failed automatic wakeup messages, attendant common shared extensions, code calling ID, and phantom extensions. (For example, it is possible to have 1600 sta- tions plus 1300 phantom extensions, that is, administration without hardware). In addition, there is another internal dial plan limit: PCOL groups, common shared extensions, access endpoints, code calling IDs, Listed Directory Numbers (LDNs), hunt groups, announcements, and TEGs are limited to 860. 2. When more than 23 B-Channels for every one D-Channel are provisioned, Non- Facility Associated Signaling (NFAS) must be used. 3. Trunks and access endpoints (see Data Parameters in Table C entries for more on access endpoints) consume the same resource. The sum of trunks and access end- points cannot exceed 400. 4. A fully equipped PPN cabinet and EPN cabinet without duplication (MCC system) has 184 port circuit pack slots available (after tone detectors and expansion inter- faces have been added in). A system using all these slots for digital line circuit packs has a maximum physical digital line capacity of 1472 lines (184 slots x 8 ports per slot). Replacing one of the digital line circuit packs with a trunk circuit pack or a cir- cuit pack other than a digital line circuit pack reduces the digital line capacity by 8 lines. Therefore, trunking and analog and hybrid terminal requirements must be con- sidered in determining the actual maximum for each system. When the second EPN is added in a G3 system, 1600 digital terminals can be configured in the system. 5. A button module (function key module) is a portion of memory required to store but- ton translations. Some digital voice terminals require no button modules while other terminals need one or more modules. Digital voice terminal button module and display requirements are given in the following table, ``Station Allocation Characteris- tics. These button module and display requirements limit the number of digital voice terminals with more than 10 feature buttons and/or displays that can be connected to a system. In G3, memory units are allocated by the system to each terminal based on the number of buttons actually translated. The button module scheme is no longer used in G3. There are 547,000 memory units available in G3 for terminals. 6. The system automatically initiates phantom user calls without any dialing from a voice terminal. An automatic wakeup call is an example of a phantom user call. 7. 40
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaSYSTEM PARAMETERS The following table shows the button module requirements of different station configurations. TABLE D. Station Allocation Characteristics bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Required Records Required Records and Station Type (G1,G3) Button Units* bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Analog set 500 S S+62 Analog set 2500 S S+62 Analog set 7101A S S+62 Analog set 8102 S S+62 Analog set 8110 S S+62 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb 10MET set - 10 buttons S S+52 20MET set - 20 buttons S + [B] S+152 30MET set - 30 buttons S + [B] S+252 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Hybrid set - 7303S S S+102 Hybrid set - 7305S S + [B] S+342 Hybrid set - 7309S S S+102 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Digital set - 7401D S S+92 Digital set - 7401 Plus S S+92 Digital set - 7403D S S+102 Digital set - 7404D S + M S+62 Digital set - 7404D w/display S + B + M S+192 Digital set - 7405D S + [B] S+342 Digital set - 7405D w/display S + B + [B] S+472 Digital set - 7406D S + [B] S+282 Digital set - 7406D w/display S + B + [B] S+342 Digital set - 7406 Plus S + [B] S+282 Digital set - 7407D (w/display) S + B + [B] S+472 Digital set - 7407 Plus S + B + [B] S+472 Digital set - 7410D S S+102 Digital set - 7434D S + [B] S+342 Digital set - 7434D w/call coverage module S + B + [B] S+542 Digital set - 7434D w/display S + 2B + [B] S+472 602A1 S + B + [B] S+342 PC S + B + [B] S+472 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb 510BCT S + B + [B] + M S+322 515BCT S + B + M S+232 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c aaaaaaaaaaaaaaaaaaa * Ð Assumes 3 call appearances per station in button 1-3 with all other available buttons assigned. Ð For call appearances other than 3, adjust total units by the following: adjustment=(Nca-3)*[(10*Ndisp)+(6*Nbri)] where: Nca=number of call appearance (assumes first Nca button is CA) Ndisp=total number of display stations in system Nbri=total number of BRI station in system 41
SYSTEM PARAMETERSaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa TABLE D (continued). Station Allocation Characteristics bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Required Records Required Records and Station Type (G1,G3) Button Units* bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Basic Attendant Console A + 2B A Enhanced Attendant Console A + 2B A Attendant Selector Console A + 2B A bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Feature Module [B] 240 Display B ** DTDM M M bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb MPDM/MTDM/7400A/7400B/7500B M M Call Coverage Module B 200 EIA (PI-Simplex) M M CDR M M Netcon Data Channel 2M 2M Processor Interface Link 2M 2M bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb [ISDN sets for G3 only] ISDN-BRI UDM - 7500 M + I ISDN-BRI set - 7505 S + I + 190 ISDN-BRI set - 7506 w/display S + I + 250 ISDN-BRI set - 7507 w/display S + I + 480 ISDN-BRI set - 8503T S + I + 50 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c LEGEND:bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Notation Meaning G1 G3 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb A Attendant record 7 7 S Basic station record 1600 1600 B Large button module 1000 2000 M Data module record 800 800 I ISDN-BRI endpoint record N/A N/A # Button memory units N/A 547200 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb c c c c c c c c c c c c c c c c c c aaaaaaaaaaaaaaaaaaa * Ð Assumes 3 call appearances per station in button 1-3 with all other available buttons assigned. Ð For call appearances other than 3, adjust total units by the following: adjustment=(Nca-3)*[(10*Ndisp)+(6*Nbri)] where: Nca=number of call appearance (assumes first Nca button is CA) Ndisp=total number of display stations in system Nbri=total number of BRI station in system ** For G3, the number of button memory units required for a display depends on the station type. The number of button memory units required for a display is indicated for each station type in the table above. Note that these values depend on the assumptions in the previous footnote. (Call appearances are only translated on buttons 1-3.) 42
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaSYSTEM PARAMETERS Notes: Regarding station allocation: 1. For G1, [B] is equivalent to B. For G3, [B] indicates large button modules that are allo- cated only when a button on that module is administered. 2. Any digital DCP station can add a 7400B, requiring one data module record. 3. A DTDM can be added to a 7403D or 7405D, requiring one data module record. 4. The 6504-T is administered as a 7505D and the 6508-T is administered as a 7507D (G3 only). 5. A data module (ADM-T) can be added to a 7505D, 7506D, or 7507D, requiring one data module record (G3 only). 6. The PC/ISDN is administered as a 7506D or 7507D with ADM (G3 only). 7. An ISDN-BRI endpoint record is required for each distinct ISDN-BRI endpoint. Thus each voice-only, data-only, or voice-data endpoint uses one of these records. 43
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaSYSTEM VERSION DETERMINATION SYSTEM VERSION DETERMINATION From the information given in Tables A, C, and D, you should now be able to determine the sys- tem version needed. Check the version in one of the boxes provided. G1 G3i G3r 43
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaHARDWARE AND SOFTWARE DETERMINATION HARDWARE AND SOFTWARE DETERMINATION Voice/Data Terminal Equipment Assignments Use Table E to list the system users and their individual equipment needs. Blank columns are provided so that you can fill in the name, extension number, application (voice and/or data), type of terminal equipment, and adjunct(s) required for each user. A current phone directory and sta- tion survey may be helpful when filling in this table. Note:Before entering the information in Table E, review the DEFINITYÒCommunications System Generic 1 and System 75 and System 85ÐTerminals and AdjunctsÐ Reference, 555-015-201, to strengthen your familiarity with the systems terminals and adjuncts. Voice/Data Terminal Totals Using the information listed in Table C and Table E, complete Tables F and G to summarize your terminal and adjunct needs. As mentioned above, detailed information for each voice terminal and adjunct can be found in the DEFINITYÒCommunications System Generic 1 and System 75 and System 85ÐTerminals and AdjunctsÐReference, 555-015-201. After completing Tables F and G, complete Table H to ensure that the identified equipment is within the maximum limits of the system. 45