Have a look at the manual ATT DEFINITY Communications System Generic 3 Planning And Configuration Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 164 ATT manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaFEATURE DETERMINATION TABLE B (continued). Features Requiring Additional Hardware and/or Software bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Hardware and/or Actual Feature Software Hardware and/or Required Software Needed bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Recorded Telephone Dic - tation AccessTelephone dictation machines and, depend - ing on the type of machine, one port on a TN746 Analog Line circuit pack or one port on a TN763 Auxiliary Trunk circuit pack for each machine assigned. bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Remote Access Dedicated trunks, if Remote Access is not available via DID. bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Report Scheduler and System PrinterG3r requires a system port comprising a TN553 Packet Data circuit pack connected to a TN726 Data Line circuit pack. For G1, G3i, and G3r, other hardware requirements depend on the type of interface used for the system printer (dedicated for the Report Scheduler feature). The printer may be an AT&T 470- or 570-series printer, which uses a serial interface, or a compatible printer. A Personal Computer (PC) may be connected to the system printer port for collection of data; however, a serial interface on the PC must be provided for the connection. The system printer can be connected as follows: dUsing the Data Communications Equip - ment (DCE) jack on the back of the Control Cabinet which provides a stan - dard EAI-232C interface. This eliminates the need for a data module. An appropri - ate 50-foot cable is required. dUsing a TN754 Digital Line port and a data module. dUsing a TN726 Data Line port and an ADU. bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Requires multi-appearance voice terminals. Ringer Cutoffbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c 25
FEATURE DETERMINATIONaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa TABLE B (continued). Features Requiring Additional Hardware and/or Software bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Hardware and/or Actual Feature Software Hardware and/or Required Software Needed bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Station Identification/ Automatic Number Identif - ication (SID/ANI) (G1 name) Calling Party Number/Billing Number (CPN/BN) (G3)For G1 or G3i, assign an Interface Link (requires a TN765 Processor Interface cir - cuit pack) for a direct EIA-232 connection (if not already used). Alternately, a data module and TN754 Digital Line port (for G1 and G3i) can be used. For G3r or G1.2SE, TN464 Universal DS1 circuit pack (for G3r or G1.2SE) is used. Note that the link is administered on the Systems Processor Channel Assignments form. The link is used as an interface to a CallVisor ISDN Gateway adjunct (3B2 Processor) in support of SID/ANI (G1) or CPN/BN (G3). Requires display terminals. Requires ACD-related hardware also. Refer to the ACD feature coverage elsewhere in this table. Requires ISDN-PRI software and CallVisor ISDN Gateway software.* bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Requires Service Observing Software.* Service Observingbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Subnet Trunking Additional TN748 circuit packs, if Routing Patterns containing ``wait symbols are used heavily, and if dial tone detection is prefer - able to waiting for interval time-out. Private Networking, UDP, or ARS software. DCS software is optional. bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Ten-Digit to Seven-Digit Conversion (G1 Only)Either ARS and Private Networking software or ARS and UDP software. bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Time of Day Routing Time of Day Routing software. ARS software. bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Uniform Dial Plan (UDP) UDP software.bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c * Software is activated by enabling this feature on the System Parameters Customer Options form. 26
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaFEATURE DETERMINATION TABLE B (continued). Features Requiring Additional Hardware and/or Software bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Hardware and/or Actual Feature Software Hardware and/or Required Software Needed bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Voice Message Retrieval A TN725 Speech Synthesizer circuit pack. Each circuit pack has four ports to provide Voice Message Retrieval. Traffic Engineer - ing is required to determine the number of circuit packs. bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Voice Terminal Display A display-equipped voice terminal and one port on a TN754 Digital Line circuit pack or TN556 ISDN-BRI circuit pack. bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c 27
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaSYSTEM PARAMETERS SYSTEM PARAMETERS Table C provides information on the overall capacities of the system. The numbers shown in the table are maximum limits for each of the items listed. This information, plus the information in Table A, can be used to determine which version of the system to order. Additional information associated with the features listed in Table C is available in the DEFIN- ITY ÒCommunications System Generic 1 and Generic 3ÐFeature Description, 555-230-201. Note:One additional parameter of the G3r system that is not noted in the table is distance. Please note that there is a maximum 100-mile end-to-end circuit distance between any two DS1 remoted EPNs. That is, if two EPNs are DS1, the sum of the total cir- cuit distance cannot exceed 100 miles. For example, if one EPN is 75 circuit miles from the Center Stage Switch (CSS), a second EPN cannot be more than 25 circuit miles away from the CSS. TABLE C. System Parameters bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Item G1 G3i G3r bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Abbreviated Dialing (AD) AD lists per system 1,600 1,600 5,000 AD list entry size 24 24 24 AD entries per system 8,000 10,000 25,000 Personal Lists 1,600 1,600 5,000 Max. entries 10 10 10 Per extension 3 3 3 Group Lists 100 100 1,000 Max. entries 90 90 90 Per extension 3 3 3 System Lists 1 1 1 Max. entries 90 90 90 Enhanced Lists 1 1 1 Max. entries 1,000 1,000 1,000 Alphanumeric Dialing No Yes Yes Max. entries None 200 1,250 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c 29
SYSTEM PARAMETERSaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa TABLE C (continued). System Parameters bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Item G1 G3i G3r bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Applications Adjuncts BX.25 Links: Single-Carrier Cabinet (SCC)/ Multi-Carrier Cabinet (MCC) 4/8 4/8 16 application processors [3B2 Message Center Service (MCS), etc.] 1 1 7 AUDIX adjuncts 1 1 5 CMS adjuncts 1 1 1 ICM adjuncts None 1 1 CallVisor ISDN Gateway 1 1 1 Message Service Adjuncts (MSA) 1 1 1 CallVisor ASAI Adjuncts None 8 8 Asynchronous Links (EIA-232) 5 5 10 CDR output devices 2 2 2 Journal printer 2 2 2 System printer 2 2 2 Property Management System (PMS) 1 1 1 BX.25 Processor Channels 64 64 128 Hop Channels 64 64 128 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Attendant Service Attendant positions (day/night) 6/1 6/1 27/1 Switched loops/consoles 6 6 6 Attendant control restriction groups 64 64 96 100s groups/attendant console 20 20 20 Queue length 30 30 300 Emergency access queue length 50 50 80 Other access queues Maximum number of queues 1 1 12 Maximum number of queue slots 50 50 80 Size range of reserved queue None 2-75 2-75 Reserved queue default size None 5 5 Centralized Attendant Service (CAS) Release link trunk groups at branch 1 1 1 Release link trunks at branch 99 99 99 Release link trunk groups at main 99 99 99 Release link trunks at main 400 400 4,000 Branches per main 99 99 99 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c 30
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaSYSTEM PARAMETERS TABLE C (continued). System Parameters bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Item G1 G3i G3r bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb ARS/AAR AAR/ARS patterns 254 254 640 ARS patterns for measurement 20 20 25 Trunk groups in an ARS pattern 6 6 16 Entries in RNX table 640 None None Entries in FNPA table 200 None None Toll tables 32 32 32 RHNPA tables 32 32 32 UDP (entries) 240 240 50,000 Choices per RHNPA table 12 12 12 Entires in TOLL table 800 800 800 Entries in HNPA & RHNPA tables 800 1,000 1,000 FRLs 8 8 8 Inserted digit strings* 1,200 1,200 3,000 Digits inserted for ARS/AAR 36 36 36 Digits deleted for ARS/AAR 11 18 18 Routing plans 8 8 8 Time of Day (TOD) charts 8 8 8 ARS/AAR table entries (NPA, NXX, RXX, HNPA, FNPA) None 2,000 2,000 Digit conversion entries 180 300 300 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb CallVisor ASAI Number of CallVisor ASAI links None 8 8 Number of BX.25 Outbound Call Management (OCM) adjuncts None 1 1 Notification requests None 170 460 Simultaneous active adjunct controlled calls None 300 3,000 Active controlling associations None 2,000 3,000 Switch to adjunct associations None 127 127 Extension controllers per station domain None 2 2 Call controllers per call None 1 1 Call monitors per call None 1 1 Number of adjunct users None 40 100 Maximum adjunct controlled agents None 200 200 OCM agent move (maximum agents) 80 80 80 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c * This is the number of available 12-character inserted-digit-strings available for AAR/ARS preferences. 31
SYSTEM PARAMETERSaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa TABLE C (continued). System Parameters bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Item G1 G3i G3r bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Authorization Classes of restriction 64 64 96 Classes of service 16 16 16 Authorization codes 5,000 5,000 90,000 Length of authorization code 4-7 4-7 4-7 Remote access barrier codes 10 10 10 Length of barrier code 4-7 4-7 4-7 Toll call lists None 1 1 Restricted call lists None 1 1 Account code digits 1-15 1-15 1-15 Unrestricted/allowed call lists 10 10 10 Total call list entries 1,000 1,000 1,000 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Automatic Callback Calls 160 160 1,000 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Automatic Wakeup Wakeup requests per system 1,600 1,600 10,000 Wakeup requests per extension 1 1 1 Wakeup requests per 15-minute interval 300 300 950 Advance wakeup request time: Hours 23 23 23 Minutes 55 55 55 Simultaneous display requests 10 10 10 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb BCMS Measured agents per system 30 200 200 Measured trunk groups 30 32 32 VDNs None 512 512 Measured trunk group members 400 400 400 Reporting periods (30 min. or 60 min.) 25 25 25 Daily summary reports 7 7 7 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Call Appearances Call appearances/station* 54 54 54 Bridged images/appearance 7 7 15 Total bridged appearances 1,600 1,600 10,000 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c * The number of call appearances is the sum of primary and bridged appearances; at most 10 can be primary. 32
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaSYSTEM PARAMETERS TABLE C (continued). System Parameters bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Item G1 G3i G3r bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Cabinets PPN MCC 1 1 1 Single-carrier control (basic) 1 1 None Single-carrier control cabinet (duplicated) 2 2 None Single-carrier port cabinet (basic) 3 3 None Single-carrier port cabinet (duplicated) 2 2 None EPN MCC 1 2 21 Single-carrier expansion control cabinet (basic) 1 2 20 Single-carrier expansion control cabinet (duplicated) 2 4 None Single-carrier port cabinet (basic) 2 9 60 Single-carrier port cabinet (duplicated) 2 8 None Inter-port network connectivity Port networks 2 3 22 Maximum number of port networks/cabinet 1 1 2 Switch nodes (simplex) None None 2 Switch nodes (duplicated) None None 4 DS1 converter complex (simplex) None None 20 DS1 converter complex (duplicated) None None 40 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Call Coverage Coverage paths 600 600 5,000 With hospitality parameter reduction 5 5 None Coverage points in a path 3 3 3 Coverage path lists 4 4 4 Coverage paths linked together 4 4 4 Coverage paths included in call coverage report 100 100 100 Coverage Answer Groups (CAGs) 200 200 500 Members per CAG 8 8 8 Max. users per coverage path 2,900 2,900 2,187 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Call Detail Recording (CDR) Call Detail Recording Utility (CDRU) capacity (calls per hour) 10,000 10,000 40,000 Number of CDRUs per system 1 1 1 CDRU trackable extensions 1,600 1,600 10,000 Intra-switch call trackable extensions 100 500 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c 33
SYSTEM PARAMETERSaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa TABLE C (continued). System Parameters bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Item G1 G3i G3r bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Call Forwarding Call forwarded numbers 1,600 1,600 10,000 Call forwarded digits 16 16 16 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Call Park Number of parked calls 482 723 723 Attendant group common shared extension numbers 10 10 40 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Call Pickup Groups Number of groups 800 800 5,000 With hospitality parameter reduction 5 5 None Call pickup members per system 1,600 1,600 10,000 Call pickup members per group 50 50 50 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Call Vectoring/Call Prompting Vectors per system None 256 512 Vector directory numbers None 500 3,000 Steps per vector None 15 32 Priority levels None 4 4 Multiple split queuing splits/call None 3 3 Multiple splits for agent logins None 3 4 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Carriers in MCCs Control carrier in simplex system 1 1 1 Control carriers in duplicated system 2 2 2 Port carrier in simplex PPN cabinet 4 4 4 Port carrier in simplex CSS PPN cabinet None None 3 Port carrier in duplicated PPN cabinet 3 3 3 Port carrier in duplicated CSS PPN cabinet None None 2 Port carrier in fully duplicated CSS PPN cabinet None None 1 Expansion control carrier in EPN cabinet 1 1 1 Port carrier in EPN cabinet 4 4 4 Port carrier in simplex CSS EPN cabinets 2-16 None None 4 Port carrier in simplex-duplicated processor CSS EPN cabinet 2 of 22 None None 3 Port carrier in simplex-fully duplicated CSS EPN cabinet 2 of 22 None None 2 Port carrier in simplex and duplicated CSS EPN cabinets 3-22 None None 4 Switch node in simplex PPN cabinet None None 1 Switch node in duplicate processor PPN cabinet None None 1 Switch node in fully duplicated PPN cabinet None None 2 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c 34
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaSYSTEM PARAMETERS TABLE C (continued). System Parameters bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Item G1 G3i G3r bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Communication Interface Links MCC 8 8 8 SCC 4 4 4 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Conference Parties 6 6 6 Simultaneous 3-way conference calls 483 483 3,542 Simultaneous 6-way conference calls 240 240 1,771 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Data Parameters Access endpoints None 400 5000 Administered connections* 18 128 128 Alphanumeric dialing No Yes Yes Maximum entries None 200 600 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Dial Plan Extensions 2,500 2,900 21,875 Number portability None None Yes Feature Dial access codes Number of access codes 70 70 70 Number of digits 1-3 1-3 1-4 Trunk dial access codes Number of access codes 197 197 1,331 Number of digits 1-4 1-4 1-4 Names Number of names 3,064 3,064 19,111 Number of characters in a name 15 15 15 Integrated directory entries 1,600 1,600 10,000 Minimum extension size 1 1 1 Maximum extension size 5 5 5 DID-listed directory numbers 8 8 20 Non-DID-listed directory numbers 50 50 666 Prefix extensions Yes Yes Yes Phantom extensions (admin. without hardware) 1,600 10,000 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Digital Data Endpoints 800 800 5,000 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Do Not Disturb (DND) DND requests per system (3) 1,600 1,600 10,000 Simultaneous display requests 10 10 30 bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c * These are permanent switched connections in G1. 35