Page 11
ANETS I12 Cooking Computer ANETS P/N 60149509 Page 11 of 28 L22-353 Rev 1 3.3 Beeper Volume and Tone: Volume and Tone of the beeper alarm may be changed in this section. Volume ranges are 1,2 and 3, where 3 is the loudest setting. This model also has a selection for tone. With display showing , press the product key [0]. Display will show . Press product key 3, display shows [VOLUME n] [BEEPER]. Use the product key [0] to scroll through choices (n= 1,2,3, or T). Beeper...
Page 12
ANETS I12 Cooking Computer ANETS P/N 60149509 L22-353 Rev 1 Page 12 of 28 6 7 3.6 Recovery Test Value: This controller maintains a record of heat up times for the appliance. A poorly running appliance will have increased recovery times stored in this display. There is no selection done here, just the display of recovery time values. With display showing , press the product key [0]. Display will show . Press product key 6, display will show [RECOVERY] [TEST]. Press the product...
Page 13
ANETS I12 Cooking Computer ANETS P/N 60149509 Page 13 of 28 L22-353 Rev 1 4 To Enter Programming Level 3 (for the Technician) With no cook timers running, displays will show one of the following displays: ; , or . Press the key. The left display will show . The right display will be blank. Enter password using the product keys as a numeric keypad for entry. Display will show . Product key indicators...
Page 14
ANETS I12 Cooking Computer ANETS P/N 60149509 L22-353 Rev 1 Page 14 of 28 4.3 Minnimum ON and OFF Cycle Time With display showing press product key 3. Display shows [MIN ON:nn] [MIN ON], where “nn” is the value, in seconds, of time for minimum heat pulse period. To change this value, use the product keys for numeric entry of a new value, then press the key to save. Display shows [MIN OFF:nn] [MIN OFF], where “nn” is the value, in seconds, of time for minimum heat off period....
Page 15
ANETS I12 Cooking Computer ANETS P/N 60149509 Page 15 of 28 L22-353 Rev 1 5 4.5 Diagnostic Menu Entry The diagnostic menu is used to determine the functionality of controller outputs and inputs. By exercising each output and examining inputs, a determination can be made if an appliance problem is controller related. In the diagnostic menu, product keys are assigned specific inputs or outputs. All outputs in the ON state should produce 22VDC at the appropriate pins on the controller...
Page 16
ANETS I12 Cooking Computer Service ANETS P/N 60149509 Page 16 of 28 L22-353 Rev 1 8 4.6 Ready Level With display showing press product key 6. Display shows [READY nn], where “nn” is the value, in degrees, below set temperature that the message is displayed. To change this value, use the product keys for numeric entry of a new value. Press the key. Display now shows . 4.7 Temperature Operating Range Forces the control to display the range of temperatures that may be set by...
Page 17
ANETS I12 Cooking Computer ANETS P/N 60149509 Page 17 of 28 L22-353 Rev 1 4.8.2 Cook Now(Single Only) Should operators be forced to acknowledge a Cook Done Alarm before starting another cook? This setting forces that requirement. Factory default value is OFF. With display showing , press product key 2. Display will show [NOW xxx] [COOK NOW], where “xxx” is ON or OFF. Use product key [0] change value. Press the to save choice. Display returns to . Note: With OFF value...
Page 18
ANETS I12 Cooking Computer ANETS P/N 60149509 L22-353 Rev 1 Page 18 of 28 4.8.5 Hold Alarm Duration With the display showing , press product key 5. Display will show [HD-DUR:nn] [DURATION], where “nn” is the time in seconds the hold alarm will sound. Use product keys for numeric entry of desired value, then press the to save choice. Display returns to . 4.8.6 Cancel Duration With the display showing , press product key 6. Display will show [CANCEL:nn] [DELAY] , where “nn” is the...
Page 19
ANETS I12 Cooking Computer ANETS P/N 60149509 Page 19 of 28 L22-353 Rev 1 4.8.9 Standing Pilot Toggle For some applications, it is desirable to maintain the gas pilot flame when the appliance is OFF. Heat from the pilot keeps solid shortening in the liquid state for quicker warm-ups in the morning. Default setting for standing pilot is off. Note: Heat Demand Profile (section 4.8.3) must be set to Generic 1, or T-stat. Standing Pilot toggle has no effect in with any other setting. With...
Page 20
ANETS I12 Cooking Computer ANETS P/N 60149509 L22-353 Rev 1 Page 20 of 28 4.9 Number of Basket Lifts With the display showing ; press key 9. Display will show ; where the number is the current setting for basket lift outputs. Use product key [0] to scroll through the choices: 0 = no basket lift outputs 1 = one basket lift output for all keys. 2 = two outputs – keys 1-6 on left side, 7-12 on the right. 3 = Four outputs: keys 1-3 and keys 4-6 on left side. Keys 7-9 and keys 10-12...