Page 31

September 2012 L01019431
Troubleshooting
Problem:
Can not establish communications with the controller.
Possible Solutions: 
1.  Make sure the controller has power.  Is the controller’s Green LED on?
2.  Check RS485 connections.
3.  Check for loose cable connection either on the controller or COM Port.
4.  Was the software installed successfully?
5. Go to Setup│Communication Settings and verify COM Port and baud rate settings.
6.  Physically verify that the axis address matches with the controller unit...

Page 32

September 2012 L01019432 Problem:
The Controller has a fault condition.
Possible Solutions:
1.  Verify your program for improper syntax that may cause an error code. 
2.  Physically press the reset button on the controller to clear an error. 
3.  Another way to clear an error is by using either the SMC50WIN software or the direct 
mode command instructions set.
4.  The SMC50WIN can clear an error in the real time motion tab section by clicking on 
the verify parameters button.
5.   The direct mode...

Page 33

September 2012 L01019433
Section 6: Sample Programs
Sample Program 1:
Sample Program 1 illustrates a typical application where a system moves to a specifi c  position 
required.  The sample program shows how to use motion and go to instruction commands. 

Page 34

September 2012 L01019434
Sample Program 2:
Sample Program 2 illustrates a typical application where a system is fi rst sent home to a datum or 
0 position.  This sample program shows how a motor will move to a 3 different positions utilizing 
some of the motion commands and loop routine. 

Page 35

September 2012 L01019435 

Page 36

September 2012 L01019436
Appendix 1: ASCII Table for Direct Mode
ASCII Symbol Hex Value ASCII Symbol Hex Value
Carriage Return 0D I 49
030J4A
1 31 L0 4C 30
2 32 LS 4C 53
333M4D
434N4E
535O4F
636P50
737S53
838V56
939Z5A
A41 ! 21
B42$24
F43+2B
G44 - 2D
H45 . 2E 

Page 37

September 2012 L01019437
ANAHEIM AUTOMATION
COPYRIGHT 
Copyright 2012 by Anaheim Automation. All rights reserved. No part of this publication may be reproduced, 
transmitted, transcribed, stored in a retrieval system, or translated into any language, in any form or by 
any means, electronic, mechanical, magnetic, optical, chemical, manual, or otherwise, without the prior 
written permission of Anaheim Automation, 910 E. Orangefair Lane, Anaheim, CA 92801. 