Page 11
11 ADDITIONAL PRECAUTIONS FOR USING THE ECOGRINDER In addition to the general safety notes described on the preceding pages, please read and observe the following precautionary notes before using the Ecogrinde\ r. DANGER! SAFETY ADVICE • Please note safety instructions on Page 3-5. • Do not pierce the motor housing as this could damage the double insulation. • Always remove plug from the outlet before making any changes to the settings or performing maintenance. • Ensure the tool is...
Page 12
12 HOW TO GRIND WARNING! 1. During operation, be sure to wear safety glasses and hearing protection.\ 2. Some dust created when using this grinder contains chemicals known to cause cancer, birth defects or other reproductive harm. Some example of these chemicals are: a. Lead based paints b. Crystalline silica found in cement, bricks and other masonry products c. Arsenic and chromium coming from pressure treated wood d. Pesticides and other chemicals that could have been applied to the work \...
Page 13
13 8. Hold the unit tightly to prevent it from walking, and remove the high spots in the work surface from the top down. 9. This grinder is designed to be used dry, if the surface is wet the dust will not be able to pass through the fan and a breakdown will result. ECOGRINDER OPERATION CAUTION! Always be sure that the tool is switched off and unplugged before adjusting or checking function on tool. MAIN CONNECTION Connect only to single-phase AC current supply and only to the main voltage...
Page 14
14 CIRCUIT BREAKER CAUTION! If the tool stops during operation you need to switch the unit off befor\ e resetting the circuit breaker. Resetting the circuit breaker with the trigger lock on can cause an accident. Note: If the circuit breaker stops the tool repeatedly, this could be an indication that excessive pressure is being applied to the tool, slowing the motor and causing it \ to overheat. Use less force and allow the tool to do the work. The circuit breaker c\ an also trip, if the carbon...
Page 15
15 2. Make sure the ON/OFF switch is off. – If you plug in the power supply cord without realizing that the switch is ON, the machine will start and may cause an accident. Make sure the on/off switc\ h trigger is out and the locking button is not engaged. 3. Inspect the protective wheel cover. – Do not remove the wheel cover. It will protect you if the grinding wheel breaks. – Be sure to firmly attach the grinding wheel or any optional accessory. 4. Inspect the grinding wheel. – Check if you...
Page 16
16 ABOUT DOUBLE INSULATION This machine is designed with double insulation. Two insulations are used between the conductor and the outer body of the machine. An electric machine with the double insulation highly improves safety from electric shocks. Do not attach or replace unspecified parts and do not assemble incorrectly. This may cause the insulation to malfunction. LAWS AND REGULATIONS OF NOISE LEVELS Please observe local laws and regulations regarding noise level in order\ to...
Page 17
17 With the slide cover as- sembly open, the unit can now be pushed up against the wall allowing the hous- ing to ride along the edge. (See Figure 6: Slide Cover Assembly Open). With the slide cover assembly open, extra care should be taken to hold the unit flat to prevent grooving along the wall. Edge grinding will work best with our 5” grinding wheel. This configuration allows you about 1mm clearance between the grinding wheel and the wall. DUST HOSE AND BAG INSTALLATION 1....
Page 18
18 3. With the dust hose attached to the tool, you can now install the dust bag onto the dust bag holder. 4. Open up the hook and loop strap and slide the hose end into bag until the end of the bag is even with shoulder on the hose end. Tighten the hook and loop strap so the strap is behind the raised lip on the hose fitting. 5. When in use, the dust bag and hose should lie flat on the ground. When the bag is new it will not inflate immediately. As the pores in the bag...
Page 19
19 ECOGRINDER MAINTENANCE DAILY 1. Before daily start-up inspect grinder, power cord, circuit breaker assembly, and grinding wheel looking for chips and cracks. Inspect the dust bag for holes or if it is full and needs to be replaced. 2. If damage has occurred, repair affected areas before use. 3. Turn the unit on to ensure that the fan is running and the dust bag is inflating. A new bag will not inflate until the pores in the material start to fill with stone dust. 4. After daily...
Page 20
20 REPLACING AND CHECKING THE CARBON BRUSHES In order to keep your tool running correctly, you need to check your carbon brushes after every one hundred hours of use. Carbon brushes wear out over time based on the grinder’s usage. If a carbon brush is worn out, it may cause the motor to malfunc\ tion or fail to run. The carbon brushes should be replaced before the twisted wire reaches the bottom of the slot. DANGER! Be sure to unplug the power cord from the outlet before servicing the un\ it,...