Home > AllTrade > Nailer > AllTrade Snapon 15Ga Finish Nailer 870013 User Manual

AllTrade Snapon 15Ga Finish Nailer 870013 User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual AllTrade Snapon 15Ga Finish Nailer 870013 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 102 AllTrade manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							MODEL #870013
    FOR CUSTOMER SERVICE
    PARA EL SERVICIO
    PARA EL CONSUMIDOR1-888-278-8092
    Printed in Taiwan  
    SNAP-ON
    ®IS A TRADEMARK LICENSED BY SNAP-ON
    ®CORP.,
    U.S.A., WHICH DOES NOT MANUFACTURE OR 
    DISTRIBUTE THIS PRODUCT. CONSUMER INQUIRES SHOULD BE
    DIRECTED TO:
    ©COPYRIGHT 2007 ALLTRADE TOOLS, LLC.
    1431 VIA PLATA
    LONG BEACH, CA 90810-1462 USA
    870015 – 18 Gauge 2 Brad Nailer _Rev 9/6/07
    15 GAUGE ANGLED FINISH NAILER
    INSTRUCTION MANUALTHIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING SAFETY, OPERATION,
    MAINTENANCE AND STORAGE OF THIS PRODUCT. BEFORE USE, READ CAREFULLY AND 
    UNDERSTAND ALL CAUTIONS, WARNINGS, INSTRUCTIONS AND PRODUCT LABELS. FAILURE TO DO SO
    COULD RESULT IN SERIOUS PERSONAL INJURY AND/OR PROPERTY DAMAGE.
    IF YOU SHOULD HAVE ANY QUESTIONS OR EXPERIENCE A PROBLEM WITH YOUR SNAP-ON 
    PRODUCT, DO NOT RETURN THIS PRODUCT TO THE STORE. PLEASE CALL OUR CUSTOMER SERVICE
    DEPARTMENT AT 1-888-278-8092. BEFORE YOU CALL, HAVE THE FOLLOWING INFORMATION 
    AVAILABLE: MODEL No., DATE PURCHASED AND STORE LOCATION. 
    						
    							CONGRATULATIONS!
    Thanks for choosing this product. Our aim is to provide you with the highest quality prod-
    ucts, and we want you to be totally satisfied with your product and our Customer Service.
    If any help or advice is needed, please contact us at 1-888-278-8092. When properly
    cared for, this product will give you many years of satisfaction.GENERAL SAFETY RULES
    READ AND FOLLOW ALL INSTRUCTIONS. Failure to fol-
    low all instructions in this manual may result in severe personal injury or death.
    Keep this manual and refer to it for Safety Instructions, Operating Procedures,
    and Warranty.
    SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
    RECOGNIZE SAFETY SYMBOLS, WORDS AND LABELS
    The safety instructions provided in this manual are not intended to cover all possible
    conditions and practices that may occur when operating, maintaining and cleaning
    power tools.
    Always use common sense and pay particular attention to all the DANGER, 
    WARNING, CAUTIONand NOTEstatements of this manual.
    This is the safety alert symbol. It is used to alert
    you to potential personal injury hazards. Obey all
    safety messages that follow this symbol to avoid
    possible injury or death.
    DANGERindicates an imminently hazardous 
    situation which, if not avoided, will result in death
    or serious injury.
    WARNINGindicates a potentially hazardous 
    situation which, if not avoided, could result in
    death or serious injury.
    CAUTIONindicates a potentially hazardous 
    situation which, if not avoided, may result in
    minor or moderate injury.
    TABLE OF CONTENTS
    CONGRATULATIONS! . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
    GENERAL SAFETY RULES  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
    RECOGNIZE SAFETY SYMBOLS, WORDS AND LABELS  . . . . . . . . 2-3
    IMPORTANT INFORMATION ABOUT THIS MANUAL  . . . . . . . . . . . 4
    SAFETY WARNINGS AND PRECAUTIONS  . . . . . . . . . . . . . . . . . . . 4-7
    FUNCTIONAL DESCRIPTION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-9
    COMPONENT INSTALLATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-9
    OPERATING THE ANGLED FINISH NAILER  . . . . . . . . . . . . . . . . . . . . . . 9-13
    SELECT TRIGGER ACTUATION MODE  . . . . . . . . . . . . . . . . . . . . . . 9-11
    ADJUSTING DEPTH OF NAILING  . . . . . . . . . . . . . . . . . . . . . . . . . . 11-12
    USING THE HOOK  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
    LOADING NAILS INTO THE AIR NAILER  . . . . . . . . . . . . . . . . . . . . 11
    USING THE NOSE ADAPTER  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-13
    REQUIRED DAILY PREPARATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-14
    USING THE AIR NAILER  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-15
    CHANGING DIRECTION OF EXHAUST AIR  . . . . . . . . . . . . . . . . . . . 15
    CLEARING JAMS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
    MAINTENANCE  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16-17
    MANDATORY MAINTENANCE  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
    TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18-19
    PARTS DIAGRAM  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19-20
    PARTS LIST  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-23
    SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
    1 YEAR LIMITED WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25-28
    2 
    						
    							IMPORTANT INFORMATION ABOUT THIS MANUAL
    Improper maintenance and operation are responsible for the majority of accidents
    involving angled finish nailers. The largest portion of these could be prevented by
    recognizing the basic safety rules and precautions. Most accidents can be avoided
    if the operator recognizes a potentially hazardous situation before it happens and by
    observing appropriate safety rules and procedures as outlined in this manual.
    Basic safety precautions are outlined in the SAFETYportion of this manual and
    throughout text in this manual where a potential hazard might occur.
    Hazards that MUSTbe avoided to prevent serious injury follow headers marked
    DANGER or WARNING. These same precautions are placed as labels on the tool
    itself.
    NEVERuse this nailer for applications that are NOTspecified in this manual.
    SAFETY WARNINGS AND PRECAUTIONS
    Do not operate angled finish nailer anywhere fastener may contact hidden
    electrical wiring.Contact with a “live” wire will make all metal parts of the
    angled finish nailer “live.” This can result in severe electrical shock, severe
    burns or death to the operator. Contact a qualified electrical contractor to
    ensure a safe working environment exists.
    Be aware of conduits or gas pipes.Striking a gas pipe could result in an explo-
    sion causing serious injuries or even death to the operator or bystanders.
    Be aware of what is behind the work piece.A fastener could travel through the
    work piece and out the other side, striking a bystander resulting in serious
    injury or even death.
    Do not operate the angled finish nailer in the presence of flammable liquids, such
    as gasoline, thinner, paint, or adhesives, gases or dust. Sparks created by the tool
    can cause flammable materials to ignite or explode. Failure to comply with this warn-
    ing could result in serious injury or even death to the operator.
    Keep bystanders, children and visitors away from area where angled finish
    nailer is being used.Distractions can result in severe injury or even death to
    anyone who inadvertently gets in the way of nailing operations.
    Do not use oxygen, combustible or bottled gases (such as carbon
    dioxide or nitrogen) as a power source for the angled finish nail-
    er.Use only compressed air from a source as outlined in this man-
    ual. The tool will explode resulting in severe injury or even death to the opera-
    tor and bystanders.
    3
    CAUTIONused without the safety alert symbol
    indicates a potentially hazardous situation which,
    if not avoided, may result in property damage.
    NOTEprovides additional information that is useful
    for proper use and maintenance of this tool. If a
    NOTE is indicated make sure it is fully understood.
    In addition to SAFETY ALERTSlisted above, there could also be numerous symbols
    alerting the operator that specific safety equipment is required to safely operate this
    tool. Learn these SAFETY SYMBOLSas well as the SAFETY ALERTSto prevent
    injury to the operator and to bystanders. 
    READ OPERATING INSTRUCTIONS:Read and understand tool labels,
    safety warnings and precautions in this manual before operating the tool.
    Failure to follow WARNINGS could result in serious injury or even death
    to the operator or bystanders.
    WEAR APPROVED EYE PROTECTION:Safety glasses must conform to
    the requirements of American National Standards Institute (ANSI) Z87.1
    and provide protection against flying particles from both front and side.
    WEAR HEARING PROTECTORS:Hearing protectors should be worn to
    protect the ears from loud exhaust noise produced by the air tools.
    USE ONLY CLEAN, DRY COMPRESSED AIR:Never use oxygen, com-
    bustible gases and any other bottled gas to operate air tools. Using these
    other sources can cause the air tool to explode.
    NEVER POINT THE ANGLED FINISH NAILER AT YOURSELF OR 
    OTHERS:Fasteners are under extreme pressure and can cause severe
    injury or even death if misused.
    DO NOT EXCEED 120 psi (8.43 kg/cm
    2G).Using excessive pressure
    from the power source can cause the angled finish nailer to explode
    resulting in severe injury or even death to the operator or bystanders. 
    						
    							Always use hearing protection to protect your ears against
    hearing loss due to exhaust noise. Always wear proper safe-
    ty glasses to prevent injuries to the eyes from fragments of
    the work piece, defective nails or other debris caused by using the angled
    finish nailer.All safety glasses must have side shields and should conform to
    the requirements of the American National Standards Institute (ANSI) z87.1.
    Failure to comply with this warning could lead to serious or permanent damage
    to the ears as well as serious damage or permanent blindness in the eyes. 
    Never carry the angled finish nailer by the air hose.A sudden disconnection
    of the air hose could cause the angled finish nailer to remain charged and an
    accidental firing could occur. Failure to comply with this warning could lead to
    serious injury to the operator or bystanders.
    Always disconnect the power source and ensure the tool is not charged
    before loading fasteners.Failure to comply with this warning could cause
    severe injury or death to the operator, bystanders and severe damage to the
    angled finish nailer.
    Never use a non-relieving air coupler with the angled finish nailer.Always
    use couplers that release any built-up charge in the angled finish nailer’s firing
    mechanism. A non-relieving air coupler can allow the angled finish nailer to dis-
    charge a fastener while the tool is disconnected from the power source. Failure
    to comply with this warning can result in serious or permanent injury or even
    death to the operator or to bystanders.
    Do not drive nails on top of other nails.Do not operate the angled finish nail-
    er at too steep of an angle. Nails can ricochet. Failure to comply with this warn-
    ing can result in serious injury or even death to the operator or bystanders.
    Do not modify the angled finish nailer in any way.Unauthorized alterations
    can jeopardize safety in the tool’s operation. Failure to follow this precaution can
    result in serious injury or even death to the operator or bystanders.
    On rooftops and other high locations, always move forward as you use the
    angled finish nailer.You can easily loose your footing if moving backwards.
    When nailing against a perpendicular surface, nail from the top down. This
    causes less fatigue and reduces the chances of accidents.
    Ensure the work area is sufficiently illuminated to operate power tools.The
    work area should be clear and free of litter.
    Do not connect angled finish nailer to an air source capable of
    generating more than 200 psi (14.06 kg/cm
    2G).Over-pressurizing
    the angled finish nailer will result in bursting, abnormal operation or
    breakage of the tool. Use only clean, dry, regulated compressed air
    at levels specified on the tool. Failure to comply can cause severe injury or
    death to the operator or bystanders.
    Do not attempt to fasten the trigger in the “ON” position.This could lead to
    an accidental discharge of the angled finish nailer. Do not operate the angled fin-
    ish nailer if any portion of the tool’s operating controls are inoperable, discon-
    nected, altered in any way or not in proper working order. Failure to comply with
    this warning could result in serious injury or even death to the operator or other
    bystanders.
    All air compressors must comply with the requirements of ANSI
    b19.3.Pressure regulators must be used to limit air pressure where
    air supply pressure exceeds the tool’s rated operating pressure.
    Do not carry the angled finish nailer with a finger on the trigger.This could
    lead to an accidental discharge of the angled finish nailer. Do not press the trig-
    ger of the angled finish nailer unless it is pressed firmly against the work piece.
    Do not point the angled finish nailer at yourself or in the direction of another
    person. Failure to comply with this warning could result in serious injury or
    even death to the operator or other bystanders.
    Do not tamper with the work piece contact.The work piece contact prevents
    accidental discharge of the angled finish nailer and should never be removed or
    compromised in any way. Failure to comply with this warning could result in
    serious injury or even death to the operator or other bystanders.
    Always disconnect air hose and remove any remaining nails:
    1. When angled finish nailer is left unattended.
    2. Before performing any maintenance or repair on the angled finish nailer.
    3. Before attempting to clear a jam in the angled finish nailer.
    4. Before moving the angled finish nailer to a new location.
    Always check the overall condition of the angled finish nailer before using.
    Check for and tighten any loose screws.Ensure all safety systems are in work-
    ing condition before using the angled finish nailer. The angled finish nailer must
    not operate if only the trigger is pulled or if only the work piece contact is
    pressed against the work piece. The angled finish nailer must only be used if
    both the trigger and work piece contact work at the same time.
    6 
    						
    							COMPONENT INSTALLATION
    Never use a non-relieving air coupler with the angled
    finish nailer.Always use couplers that release any built-up charge in the angled
    finish nailer’s firing mechanism. A non-relieving air coupler can allow the angled
    finish nailer to discharge a fastener while the tool is disconnected from the
    power source. Failure to comply with this warning can result in serious or per-
    manent injury or even death to the operator or to bystanders.
    When selecting an air compressor, it must comply with the requirements of the
    American National Safety Institute - ANSI B19.3.
    Choose an air compressor that can supply more than the required air pressure to
    ensure optimum efficiency. Always use clean, dry compressed air with a maximum
    pressure of 200 psi. Use a pressure regulator and set the pressure between 70 –
    120 psi. (5.0 – 8.5 kg/cm2G). Before each use, check the pressure regulator to
    ensure it is functioning within the proper pressure range.
    Using an air pressure of more than 120 psi can
    cause the angled finish nailer to malfunction or possibly explode
    causing severe injury or property damage.
    SELECTING A PROPER AIR HOSE
    Use an air hose with the largest diameter and shortest length possible to ensure
    continuous, efficient nailing operations. Using an air pressure of 70 psi (5.0
    kg/cm
    2G), an air hose with an inside diameter of 1/4 (6.5 mm) or greater and a hose
    length of less than 6.6 ft (20 m), it is recommended that a 0.5 second interval be
    allowed between each nailing. Air supply hoses shall have a minimum working pres-
    sure of 150 psi (10.7 kg/cm
    2G) or 150% of the maximum pressure produced by the
    compressor or whichever is higher.
    Low air output by the compressor or a longer hose with
    a smaller inside diameter in relation to the nailing frequency may decrease
    the driving capability of the air nailer.
    SELECTING A QUICK DISCONNECT
    1. Remove the plastic protective plug
    from the tool’s air inlet.
    2. Insert a 1/4 NPT male quick 
    disconnect into the air inlet. Install the female portion to the air hose.
    Thoroughly clean and maintain the angled finish nailer after every use.
    Lubricate moving parts to prevent rust and minimize friction-related wear. Wipe
    down the entire tool and remove all dust from the moving parts. Properly store
    the angled finish nailer in a suitable case to keep it ready for the next job.
    All maintenance and repairs should be performed by an authorized repair
    facility.Call 1-888-278-8092 to obtain a list of repair facilities in your area or
    to make arrangements to return the tool for service.
    FUNCTIONAL DESCRIPTION
    CONTROLS AND COMPONENTS:
    1. Exhaust Cover
    2. Trigger
    3. Nail Depth Adjuster
    4. Latch
    5. No-mar Nosepiece
    6. Pusher 
    7. Hanging Hook
    8. Air Inlet 
    9. Nail Release
    7
    10. Work Piece Contact 
    11. Trigger Actuation Mode Selector
    ACCESSORIES:
    12. Lubricant 
    13. Safety Glasses
    14. Hex Wrenches (2) 
    15. Fasteners
    8 
    						
    							OPERATION IN SINGLE SEQUENTIAL ACTUATION MODE
    To select the Single Sequential Actuation Mode (see
    Figure 1): 
    1. Press and hold the red Actuation Selector embedded
    in the trigger.
    2. Rotate Actuation Selector down to the Single
    Sequential Actuation (T).
    3. Release Actuation Selector, ensuring locking tab is
    fully seated in the slot.
    Ensure selector has locked into position. Ensure 
    actuation process is fully understood before attempting to use angled 
    finish nailer.
    TO USE THE ANGLED FINISH NAILER IN SINGLE SEQUENTIAL 
    ACTUATION MODE:
    1. Firmly grip angled finish nailer 
    handle.
    2. Position angled finish nailer work
    piece contact on work piece surface.
    3. Push angled finish nailer against
    work piece compressing work piece
    contact.
    4. Pull trigger on angled finish nailer to
    drive nail. The angled finish nailer will
    recoil away from the work piece as
    nail is driven.
    5. Remove finger from trigger and lift
    angled finish nailer away from surface
    of work piece.
    OPERATION IN CONTACT ACTUATION MODE
    When using contact actuation mode, be careful of unin-
    tentional double fires resulting from tool recoil. Unwanted fasteners may be
    driven if the work piece contact is allowed to accidentally re-contact the work
    piece.
    9
    To improve the connection between the quick disconnect and air nailer, and to help
    prevent oxidation, apply PTFE tape or joint compound to the connector threads
    before insertion. 
    3. Snap the air hose onto the quick disconnect on the air nailer. Check for air
    leaks.
    LUBRICATION
    To ensure maximum performance, it is recommended to install an air set (oiler, reg-
    ulator, and air filter) as close as possible to the air nailer. Adjust the oiler so that
    approximately one drop of oil will be released for every 50 nails.
    If an air set is not used or is unavailable, oil the tool using pneumatic tool oil by plac-
    ing 2 or 3 drops into the air inlet. This should be done before and after use.  For
    proper lubrication, the tool must be fired several times after the oil is introduced to
    the filter.
    OPERATING THE FINISH NAILER 
    Always use hearing protection to protect your ears against
    hearing loss due to exhaust noise. Always wear proper safe-
    ty glasses to prevent injuries to the eyes from fragments of
    the work piece, defective nails or other debris caused by using the angled
    finish nailer.All safety glasses must have side shields and should conform to
    the requirements of the American National Standards Institute (ANSI) z87.1.
    Failure to comply with this warning could lead to serious or permanent damage
    to the ears as well as serious damage or permanent blindness in the eyes. 
    Always disconnect the air hose before making adjustments or checking the
    functionality of the air nailer.SELECT TRIGGER ACTUATION MODE
    The angled finish nailer is equipped with a selectable trigger. This allows the selec-
    tion of Single Sequential Actuation Modeor Contact Actuation Mode.
    Figure 1
    10 
    						
    							To select Contact Sequential Actuation Mode (see Figure 2): 
    1. Press and hold Actuation Selector embedded in the
    trigger.
    2. Rotate Actuation Selector up to the Contact
    Sequential Actuation (TTT).
    3. Release Actuation Selector, ensuring locking tab is
    fully seated in the slot.
    Ensure selector has locked into position. Ensure 
    actuation process is fully understood before attempting to use angled 
    finish nailer.
    TO USE THE ANGLED FINISH NAILER IN CONTACT ACTUATION MODE:
    1. Firmly grip angled finish nailer handle.
    2. Pull and hold the angled finish nailer trigger.
    3. Push angled finish nailer against work piece compressing work piece contact.
    4. The angled finish nailer will drive nail upon contact. The angled finish nailer will
    recoil away from the work piece as nail is driven.
    ADJUSTING DEPTH OF NAILING
    Be aware of material thickness when using nailer. A pro-
    truding nail may cause injury.
    Adjust the depth of nailing by turning the adjust-
    ment knob (Figure 3, Item 1) to the left (A) for
    the deepest setting and to the right (B) for the
    shallowest setting. To increase the depth of the
    nails, when the adjustment knob is already set
    to its highest setting, increase the air pressure.
    To decrease the depth of nails when the adjust-
    ment knob is already set to its lowest setting,
    decrease the air pressure. Should nails be driv-
    en too deep even when the adjustment knob is
    set at its lowest setting, decrease the air pres-
    sure. In general, the angled finish nailer will
    have a longer service life when the adjustment
    knob is set a lower setting causing less wear
    and tear on the driving mechanism.
    Always disconnect the air nailer before making any
    adjustments to the nail depth knob.
    USING THE HOOK
    Always disconnect the air hose before hanging the air nailer with the hook.
    NEVER hook the air nailer in a high location or on an unstable platform.
    LOADING NAILS INTO THE AIR NAILER
    Always disconnect the air hose from the nailer before adding or removing
    nails to the air nailer.
    NEVER use deformed nails or nail strip. Failure to observe this precaution
    can result in poor nail feeding and/or jams in the feeding mechanism.
    To load nails in angled finish nailer, slide nails through opening in back of magazine.
    Pull pusher back until it is behind nails and release. (Figure 4). 
    To remove nails, depress center of pusher until pusher is no longer contacting nails.
    Allow pusher to release past nails and slide nails back until they rest against nail
    release. Depress nail release and nails can be removed from end of magazine.
    USING THE NO-MAR NOSEPIECE
    Always disconnect the air hose before attaching the 
    no-mar nosepiece.
    11
    Figure 3Figure 4
    Figure 2
    12 
    						
    							4. With work piece contact against the work piece, pull trigger. The trigger must
    operate smoothly.
    5. Connect air supply and set regulator for 70 psi. DO NOT load a fastener strip.
    6. Select Single Sequential Actuation Operation. Check for leaks. Without pulling
    the trigger, press the work piece contact against the work piece. The tool MUST
    NOToperate. Holding the tool away from the work piece, pull trigger and hold
    for 5 seconds. The tool MUST NOToperate. Repeat steps several times.
    Without pulling trigger, press nailer against work piece and pull trigger. The tool
    MUSToperate. Release trigger. Driver MUSTmove up.
    7. Select Contact Actuation Operation. Holding nailer away from work piece, pull
    trigger. The tool MUST NOToperate. While still pulling trigger, press the nailer
    against work piece. The tool MUSToperate.
    8. If Steps 1 through 7 function properly, prepare the tool for use. Select opera-
    tion mode and load fasteners. 
    9. Set the required depth of drive. 
    10. Repeat these steps daily. Test again if the nailer is dropped, jammed, etc.
    USING THE AIR NAILER
    To drive a nail, place the work piece
    contact of the air nailer against the work
    piece and pull the trigger. See Figure 6.
    To avoid any unexpected nailings, 
    perform the operation as follows:
    1. Avoid placing the work piece contact
    against the work piece with excessive
    force.
    2. Pull the trigger fully and hold it in the
    fired position for 1 to 2 seconds
    before releasing the trigger. This will
    give the air nailer time to completely
    expend the previous nail and build
    enough pressure for the next nail.
    14
    In order to prevent the surface of the work piece from being scratched or damaged,
    use the nose adapter. Install nose adapter by fitting the protrusion on the inside of
    adapter with notch in contact arm. See Figure 5. 
    Store the nose adapter in place when not being used.  
    Never use a non-relieving air coupler with the angled
    finish nailer. Always use couplers that release any built-up charge in the
    angled finish nailer’s firing mechanism. A non-relieving air coupler can
    allow the angled finish nailer to discharge a fastener while the tool is dis-
    connected from the power source. Failure to comply with this warning can
    result in serious or permanent injury or even death to the operator or to
    bystanders.
    When the air hose is disconnected, the pressure reservoir in the air nailer will dis-
    charge removing any built-up air inside the tool.
    REQUIRED DAILY PREPARATION
    The following steps should be performed on a daily basis to ensure the angled fin-
    ish nailer is operating correctly:
    1. Disconnect air supply from nailer and remove fastener strip.
    2. Check all screws, nuts and pins and ensure all are tight.
    3. Press the pusher release button and slide back the pusher assembly
    (Overriding the reload indicator). Press the work piece contact against a work
    piece ensuring smooth movement.
    13
    Figure 6
    Figure 5 
    						
    							MAINTENANCE
    STORAGE OF NAILS
    Always handle nail strips and their box very carefully. If the nail strips have been
    mishandled, they may be out of shape or have breaks in the connecting strips. This
    will cause the nails to feed poorly and possibly result in misfiring or jams in the air
    nailer.
    Avoid storing nails in a very humid or hot environment or place in direct sunlight. 
    OVERALL MAINTENANCE OF AIR NAILER
    Always disconnect the air hose from air nailer before
    attempting any type of maintenance or visual inspection of tool.
    Always visually inspect air nailer before
    every use. Check on the overall condition
    and for any loose screws. Tighten any
    screws that have come loose. See Figure
    9.
    Visually inspect the work piece contact
    and trigger to ensure there is free move-
    ment. See Figure 10.
    When the tool is not going to be used for
    an extended period, wipe off all dust and
    debris that have collected on it. Tighten all
    loose screws. Lubricate the firing mecha-
    nism with pneumatic tool oil. See page 9
    for Lubrication.
    Store the air nailer in a safe location or in
    suitable carrying case. It is recommended
    that the air nailer be secured in a locked
    location to prevent unauthorized usage. 
    Avoid exposure to direct sunlight and/or locations with high humidity and heat.
    DO NOT hold the trigger in a half-pulled position. This
    could cause an unexpected nailing to occur if the work piece contact is permit-
    ted to re-contact the work piece. Failure to comply could result in damage to
    work piece.CHANGING DIRECTION OF EXHAUST AIR
    The direction of exhaust air on the air nailer can be
    directed 360˚ degrees by placing hand on exhaust
    cover and turning. See Figure 7.
    CLEARING JAMS
    Typically, jams are caused when a fastener or a fastener fragment becomes wedged
    between the driver blade and nail guide. Using the wrong fastener can also cause jams.
    TO CLEAR A JAM:
    1. Disconnect the air supply and remove the
    fastener strip. Leave the pusher assem-
    bly open.
    2. Pull out the latch tab and open the jam-
    clearing door.
    3. Remove all debris that has built up dur-
    ing operation.
    4. Remove jammed fastener. If fastener is
    difficult to grasp, use needle nose pliers
    instead of fingers. 
    5. If necessary, insert a flat-blade screw-
    driver so that it touches the tip of the
    driver blade. See Figure 8. Tap the screw-
    driver with a hammer. The screwdriver
    will push the driver blade back, freeing
    the jam.
    6. Close the jam-clearing door securely.
    15
    Figure 8
    Figure 9
    Figure 10
    Figure 7
    16 
    						
    							TROUBLESHOOTING
    Most minor problems can be resolved quickly and easily using the troubleshooting
    table below. For problems that cannot be solved, contact Customer Service (toll
    free) at 1-888-278-8092.
    PROBLEM POSSIBLE CAUSE SOLUTION Remove the air nailer from use and schedule to have it
    repaired at an authorized repair facility if the work piece contact is binding
    or not moving freely. Do not attempt to repair the air nailer. Failure to com-
    ply can result in malfunction of the tool and severe injury to the operator or
    any bystanders.
    MANDATORY MAINTENANCE 
    All maintenance and repairs should be performed by an
    authorized repair facility.  Call 1-888-278-8092 to obtain a list of repair facil-
    ities in your area or to make arrangements to return the tool for service.
    ACTION REASON OPERATION
    Clean magazine and
    feeder mechanism.
    Prevents angled finish
    nailer from jamming.
    Use compressed air and
    clean daily.
    Inspect and ensure work
    piece contact operates
    properly.
    Ensures operator safety
    and keeps angled finish
    nailer working 
    efficiently.
    Use compressed air and
    clean daily.
    Lubricate angled finish
    nailer after every use
    using pneumatic tool oil.
    Extends life of angled
    finish nailer.
    Apply 2 – 3 drops of
    pneumatic tool oil to
    angled finish nailer air
    inlet after every use.
    Nailer operates, but no
    nail is driven.
    Check for jammed nail.
    Ribbon spring weakened
    or damaged.
    Inspect nail feeder
    mechanism.
    Ensure correct nails are
    being used.
    Clear jammed nail.
    Replace ribbon spring.
    Clean and lubricate nail
    feeder.
    Use ONLY recommend-
    ed nails.
    Weak drive. Slow to
    cycle between nailings.
    Ensure proper air pres-
    sure is being used.
    Inspect for worn driver
    blade.
    Inspect piston O-ring for
    wear or damage.
    Increase air pressure, 
    Do not exceed 120 psig
    (8.3 bars, 8.5 kg/cm
    2)
    Contact Customer
    Service.
    Nails driven too deep.
    Check air pressure.
    Reduce air pressure.
    Angled finish nailer
    feeds intermittently or
    skips nails.
    Ensure correct nails are
    being used.
    Inspect nail feeder
    mechanism.
    Ribbon spring weakened
    or damaged.
    Piston O-ring damaged
    or worn
    Nail feeder worn or
    damaged.
    Use ONLY recommend-
    ed nails.
    Clean and lubricate nail
    feeder.
    Replace ribbon spring.
    Use recommended
    pneumatic tool oil.
    Contact Customer
    Service.
    Replace nail feeder.
    Nails jam or driven nail
    is bent.
    Ensure correct nails are
    being used.
    Inspect for worn driver
    blade.
    Nail feeder worn or
    damaged.
    Use ONLY recommend-
    ed nails.
    Contact Customer
    Service.
    Replace nail feeder.
    17 
    						
    All AllTrade manuals Comments (0)

    Related Manuals for AllTrade Snapon 15Ga Finish Nailer 870013 User Manual