Home > Alarm Lock > Alarm Lock > Alarm Lock PL3000 Programming Instructions User Manual

Alarm Lock PL3000 Programming Instructions User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Alarm Lock PL3000 Programming Instructions User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 84 Alarm Lock manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							1 
    Trilogy 
    PL3000 
    Programming Instructions 
    © ALARM LOCK 2007 
    AL-PRE PROXCARD® 
    READER / ENROLLER 
    DL-WINDOWS PROGRAMMING 
    SOFTWARE 
    PL Trilogy Series 
    Stand-Alone Access Control System 
    with ProxCard
    ® Access 
    WI1280A  5/07 
      
    PL3000 
    HID HID CORPORATION 
    PROXCARD® 
    PROXKEY® 
    KEYFOB 
    AL-IR1 PRINTER 
    AL-DTM 
    DATA TRANSFER 
    MODULE 
    345 Bayview Avenue 
    Amityville, New York 11701 
    For Sales and Repairs 1-800-ALA-LOCK 
    For Technical Service 1-800-645-9440
      
    						
    							2 
    Table of Contents 
    THE ALARM LOCK TRILOGY PL-SERIES STAND-ALONE ACCESS CONTROL SYSTEM IS A STATE-OF-THE-ART  
    M
    ICROPROCESSOR-BASED PROGRAMMABLE PROXIMITY SECURITY LOCK. 
    PL3000 
    Features an HID compatible ProxCard® reader, and a real-time clock/calendar 
    that automatically adjusts for Daylight Saving Time and allows for automated 
    programming of events.  To increase security, the PL Series lock does not in-
    clude a keypad.  Features three methods of programming:  (1) transfer program-
    ming instructions directly from your laptop or desktop PC using DL-Windows 
    software and a special AL-PCI2 cable; (2) transfer data from your PC to your 
    PL3000 lock via the AL-DTM handheld Data Transfer Module; and (3) use 9 
    proximity cards as Function Cards when lock is first powered up.  In addition, 
    data can be retrieved from the lock in one of three ways (1) through an infrared 
    printer; (2) directly from the lock to the PC; or (3) through an AL-DTM to your PC.   
     
     
     
     
     
     
     
     
    Note:  ProxCard® and ProxKey® are trademarks of the HID© Corporation. 
    PL SERIES LOCKS 
    PL3000  
    PL Series Lock Features ............................... 3  
    Supported Products ....................................... 4  
    Lock Design Overview ................................... 5  
    Terminology Used in this Manual ................. 6  
    Default User Numbers ................................... 8  
    LED and Sounder Indicators ......................... 9 
    Product Communication Examples ............. 10  
    Wiring and Power Up ..................................... 11 
    Battery Replacement ..................................... 11 
    Erase All Programming ................................. 11 
    Quick Start ...................................................... 12 
    Function Cards--Overview ............................ 14 
    Function Card #1 ............................................ 15 
    Function Card #2 ............................................ 16 Function Card #3 ............................................ 18 
    Function Card #4 ............................................ 19 
    Function Card #5 ............................................ 20 
    Function Card #6 ............................................ 21 
    Function Card #7 ............................................ 22 
    Function Card #8 ............................................ 23 
    Function Card #9 ............................................ 24 
    User Card Record Sheet ................................ 25 
    Glossary .......................................................... 26 
    Lost Function Cards ...................................... 27 
    Warranty .......................................................... 28  
    						
    							3 
    Audit Trail 
    •40,000 Event Capacity 
    •Entries Logged with Time and Date 
    •Critical Programming Events Logged 
    •Printable using the AL-IR1 Hand-Held Printer (only via programmed Function Cards) 
    •Uploadable using Alarm Locks DL-Windows software  
    •Transferable through AL-DTM 
     
    Lock Features 
    •Metal Key Override for all cylindrical locks 
    •Non-Volatile (Fixed) Memory 
    •Real-Time Clock (with automatic Daylight Saving Time adjust)
     
    •Programmable Relay (via DL-Windows only) 
    •Visual and Audible Feedback 
    •Battery Status Monitor 
     
    Scheduling (Using DL-Windows) 
    •500 Scheduled Events 
    •Automated Unlock/Lock 
    •Enable/Disable Users  
    •Enable/Disable Groups  
    •Real-time clock and calendar  
     
    User Access Methods 
    •ProxCard® and ProxKey® Keyfob 
    •Batch Enroll - Quickly and easily enroll multiple ProxCards
    ® and ProxKey® keyfobs without the use of a PC 
     
    Note:  ProxCards® and ProxKey® Keyfobs both function identically (Keyfobs can be substituted for 
    all references to the ProxCard® in this manual). 
     
    User Features 
    •1700 Users (1999 using DL-Windows) 
    •Service Card (“One-Time-Only” Code) 
    •User Lockout Mode (only via programmed Function Cards) 
    •Users Assignable to 4 Groups  
     
    Computer Programming 
    •Partial Programming may be performed at the lock or full programming from a PC using Alarm Locks 
    DL-Windows Software
     
    PL Series Lock Features 
    HID HID CORPORATION  
    						
    							4 
    AL-DTM - Data Transfer Module 
    The enhanced AL-DTM may be used to transfer program data between a PC running DL-Windows 
    software and locks.  Use of the older AL-DTM model 1 is not recommended.  
     
    Prox Card Reader/Enroller (AL-PRE) 
    An AL-PRE is used to quickly enroll multiple ProxCards® and ProxKey® keyfobs into DL-W indows.  Use the 
    supplied 9-pin DB9 to DB9 serial cable to connect the AL-PRE to your computer’s serial COM port.  Compatible 
    with most HID ProxCards
    ® and ProxKey® keyfobs (37 bits or less).  For PDL and PL series locks only. 
    HID 
    HID CORPORATION 
    ProxCard® / ProxKey® Keyfob 
    Compatible with most HID ProxCards® 
    and ProxKey® keyfobs (37 bits or less).  
    Note:  ProxCard® and ProxKey® are trademarks of 
    the HID© Corporation. 
    Double-ended Mini Banana Plug Connector 
    After you create the program in DL-W indows and transfer the program from your computer to an AL-DTM, 
    transfer the program from the AL-DTM to the lock(s) via a double-ended mini banana plug.  You can also 
    use this cable to transfer the Lock Program from your lock to an AL-PRE. 
    DB9 to DB9 Serial Cable 
    Enroll ProxCards quickly into DL-Windows, then transfer this new ProxCard® data from the computer to 
    the AL-PRE via this 9-pin DB9 to DB9 serial cable.  Once the data is in the AL-PRE, you can transfer the 
    data to the lock via the double-ended mini banana plug (see above), thus avoiding the need to use an AL-
    PCI2 cable for this process. 
    AL-PCI2 Cable 
    An ALARM LOCK AL-PCI2 cable is required to communicate between your computer’s RS-232 serial com-
    munications port (COM 1-4) and the AL-DTM or lock.  One end of the AL-PCI2 cable is designed to be used 
    on a 9-pin serial Com Port.  If your computer has a 25-pin Com Port only, a 25-pin to 9-pin adapter must be 
    used.  The other end of the AL-PCI2 cable features a 2-pin banana plug connector which is polarity sensi-
    tive--the TAB (marked “GND”) side must be plugged into the lock’s black (left) terminal. 
    Supported Products 
    Infrared Printer (AL-IR1) 
    An AL-IR1 printer is used to print Audit Trails 
    without the need for a PC.  Its infrared reader 
    means no cable connection to the lock is 
    needed.  
    						
    							5 
    Lock Design Overview 
    Why Use Software inside a Lock? 
    With ordinary door locks, the need to make physical copies of metal keys and distributing them can be a huge organ-
    izational and financial task -- and what will you do if someone causes a security breach by losing their key? 
     
    The answer lies in the advantage of SOFTWARE.  Software (also called firmware) is not hard or fixed like hard-
    ware is.  Software is soft -- flexible and changeable to your needs.  Software exists inside your Alarm Lock™ series 
    lock, and can be programmed (and re-programmed again and again) to suit your changing requirements.  No more 
    metal keys to distribute...instead, distribute ProxCards
    ® -- and delete them from the software when needed.  (A Prox-
    Card® is the software equivalent of a metal key--present a programmed card to the reader to unlock the lock).  Fur-
    thermore, proximity cards differ from metal keys in that proximity cards are not duplicates---each card is unique to 
    the lock, and therefore cards can be deleted from the lock without needing to be in hand.   
     
    Preparing to Program your Lock 
    You can program your lock in one of three ways: 
     
    1.    By a direct connection to a PC with the computer program DL-Windows installed. 
    2.    By a direct connection to an AL-DTM module, allowing the transfer of lock data from the computer to the lock. 
    3.    By using 9 proximity cards (provided) as Function Cards when lock is first powered up. 
     
    It is recommended that DL-Windows be used when programming your PL3000 lock--especially if you intend to enroll 
    many User Cards.  DL-Windows can always be used as a back-up, restoring the information to your PL3000 lock 
    should the future need arise.  It is also recommended that you make use of the 9 Function Cards in addition to DL-
    Windows.  Although this guide will show you how to program your lock manually, without DL-Windows, please see 
    User Guide OI237 for programming and additional information about DL-Windows. 
     
    Programming your lock begins after you unpack it from the box -- there is a specific procedure outlined in Quick 
    Start (page 12) in which you wake up the lock to prepare it for programming.  This Quick Start procedure shows 
    you all the steps required to get your lock to start working using Function Cards.   
     
    Turn the page and learn about the special terminology used with your lock.  Once that is clear, use the Quick Start 
    procedure on page 12 to help you get up and running.   
    ProxCard / Keyfob Reader 
    PC / AL-DTM Interface 
    (communications port) 
    Tri-Color Status LED 
    Infrared LED (for Printer)  
    						
    							6 
    Terminology Used in this Manual 
    What is a Lock Program? 
    (Also called Lock Programming).  A Lock Program contains the 
    instructions that a lock uses to perform its various functions.  You 
    can also use DL-Windows (defined below) to create a Lock Pro-
    gram on your computer, and then transfer and store the Program 
    in the circuitry contained inside the lock itself.  The Lock Program 
    is essentially a computer database file that maintains feature set-
    tings, schedules, audit trails, etc.  Using DL-Windows, Lock Pro-
    grams can be created with default information, edited on your PC, 
    and then sent to (or received from) locks.   
     The Lock Program consists of 4 areas:  Prox Card Entries, Fea-
    tures, Time Zones, and Schedules, all defined below:   
     
     
    What are Prox Card Entries? 
    Because this lock has no keypad through which to enter User 
    Codes, proximity cards can be added to the Lock Program, allow-
    ing entry (the PL3000 to unlock) for valid proximity cards.  The 
    proximity card entries are a part of the Lock Program, and the Lock 
    Program is stored in the lock circuitry awaiting the Users to present 
    their programmed proximity cards.   
     
     
    What are Features? 
    Your lock is designed to support several options and functions.  
    Using DL-Windows software (the Programmable Features win-
    dow), you can select the features you wish to activate, such as if 
    the lock will automatically adjust for Daylight Saving Time in the 
    spring and autumn, or if the lock sounder should be disabled or 
    enabled.  Note:  Features may only be added via DL-Windows 
     
     
    What is a TimeZone? 
    Events (recorded lock activities) can be programmed to occur at 
    certain times.  It is these times (for example, “every Tuesday at 
    5PM”) that are referred to as TimeZones.  In DL-Windows, you can 
    use the Schedule-TimeZone screen to create these TimeZones, 
    and once created, you can link events to these TimeZones.  Note:  
    TimeZones may only be added via DL-Windows 
     
     
    What is a Schedule? 
    Your lock can be programmed using DL-Windows to maintain a 
    schedule in which certain events can occur automatically.  For ex-
    ample, you can program the lock to allow Groups of Users (with 
    their User Codes) access ONLY during specific business hours.  
    With another example, you can program another lock to UNLOCK 
    at 9am, LOCK at noon for lunch, UNLOCK at 1pm, and LOCK 
    again at 5pm--every weekday.  As you can see, many different 
    combinations of Schedules can be created to suit the needs of the 
    Users.  First you create TimeZones (see above).  Next you create 
    events and link them to your TimeZones (also using the Sched-
    ule-TimeZone screen in DL-Windows).  When finished, you can 
    view (in DL-W indows) your schedule in the Schedule View 
    screen.  Note:  Schedules may only be added via DL-Windows
     
     
     
    What is a User? 
    A User is a person who is authorized to simply use or make certain 
    programming changes or operate the lock.  This User can be any-
    one--from a one-time visitor (who will almost certainly have no au-thority to make changes) to the owner of the building in which the 
    lock is installed (who will probably wish to have total authority to 
    make changes).  The PL Series locks can hold up to 1999 Users in 
    its programming memory using DL-W indows, and 1700 with the 
    Function Cards (see Function Card definition below).   
     
     
    What is a Programming Level? 
    With other Trilogy locks that possess keypads (such as the 
    PDL3000, ETPDL, etc.), the Programming Level defines the range 
    of programming tasks a User is allowed to perform using the key-
    pad.  However, the PL3000 lock does not include a keypad, and 
    changes to the PL3000 Lock Program are initiated by the Function 
    Cards.  Therefore, the physical possession of the Function Cards 
    is the sole factor for determining who can make changes to the 
    Lock Program.  The Function Cards, once programmed, must 
    be safeguarded, as they are essential to the security of the 
    lock.   
     
     
    What is a User Number? 
    (User Number = Location Number = User Location = Slot in Lock) 
    User Numbers are used primarily with DL-W indows, and are sig-
    nificant within each individual lock only.  PL Series locks can hold 
    up to 1700 proximity cards in its programming memory, which can 
    be thought of as simply a numbered list from 301 through 2000 
    (User Numbers 2-300 are not accessible except through DL-
    Windows, making the total Users 1999--but only when using DL-
    Windows.  User Number 1, the Master, is not accessible with the 
    PL3000).  Each entry in the list is represented by a User Number, 
    and proximity cards can be assigned to (programmed into) each 
    location.  When a proximity card is assigned to a location, the card 
    information is stored within the Lock Program.  Because Users are 
    physically given proximity cards, it is convenient to think of each 
    location as a User, although technically the User Number is a 
    location within the Lock Program that holds the proximity card in-
    formation.  It is easier to simply say User 297 rather than The 
    User in possession of the proximity card assigned to the User Lo-
    cation number 297. 
    Note:  Where a User is located in this list--their User Location--is a 
    commonly used description of their User Number.  Because of 
    their similarities, a User Number, User Location and Location 
    Number can be used interchangeably.  In some DL-Windows 
    screens, the word Slot is also used.  All of these terms are meant 
    to convey the same concept. 
     
    Note:  User Numbers 1-11 have special programming abilities 
    within other Trilogy locks that possess keypads.  However, with 
    the keypad-less PL3000, several differences exist:  User Number 
    1 is disabled, and User Numbers 2-11 possess no special signifi-
    cance other than as Basic Users, programmable using DL-
    Windows only.  In addition, Users 2-11 remain consistent with 
    other Trilogy locks in that they are unaffected by Entry Delay 
    changes.  (In DL-Windows, Entry Delay is located in the Features 
    screen, Options tab.  With other keypad locks, Function 67 is 
    used). 
     
     
    What is a Group? 
    With many lock applications, it is convenient for large numbers of 
    similar Users to be grouped together.  Placing Users into Groups 
    (by assigning them specific User Numbers) allows large numbers 
    of Users to be controlled all at once rather than individually--saving  
    						
    							7 
    time and effort.  In DL-Windows, Groups are controlled via sched-
    ules, and a typical example involves enabling or disabling a 
    Group at a certain time.  Note:  Groups may only be added or 
    changed via DL-Windows.   
     
     
    What are Function Cards? 
    There are three ways to program the PL3000 lock:  (1) Using DL-
    Windows; (2) Using a pre-programmed AL-DTM module; and (3) 
    Using proximity cards as Function Cards at first power-up.  The 
    Function cards are simply 9 standard proximity cards labeled one 
    through nine, and after being presented (enrolled into) the 
    PL3000 lock (see page 12 for procedure), each card will then be 
    able to perform a specific function, as follows: 
     
    Card 1        Initiates PC communications (User 298). 
    Card 2        Initiates AL-DTM communications (User 299). 
    Card 3        Initiates entry of new proximity cards starting at 
    User 301 (and ending at User 2000). 
    Card 4        Initiates removal of next presented proximity 
    card. 
    Card 5        Toggles Passage Mode. 
    Card 6        Initiates AL-IR1 printing with Time, Date, Ver-
    sion Number and Audit Trail Log. 
    Card 7        Toggles Total User Lockout mode. 
    Card 8        Enables Function Card #9 (User 297). 
    Card 9        The Service Card, allowing access one-time-
    only (User 300). 
     
    It is still possible to perform all lock programming via DL-
    Windows or via an AL-DTM module, with or without ever en-
    rolling the Function Cards at first start up.  However, it is 
    highly recommended that Function Cards be enrolled even if you 
    do not intend to use them--because once the lock is in operation, 
    you may not enroll Function Cards without first performing a cold 
    start (removing all programming and thus re-loading all original 
    factory default settings).  See Glossary entry for Default on page 
    26 for more information.   
     
    Note:  If the Function Card enrollment process is bypassed and 
    the AL-DTM is used to move programming data from the PC to 
    the PL3000 lock, the PL3000 lock will always default to Door 
    #1.  In addition, the current AL-DTM allows the programming of 
    specific door numbers (and their associated data files), regardless 
    of the door number sent to the AL-DTM by the PL3000 lock.  See 
    page 16 for more information.   
     
    IMPORTANT NOTE:   
    When programming is sent from DL-W indows (or an AL-DTM) to 
    the lock, Function Cards 1, 2, 8, and 9 will be overwritten with the 
    existing data in DL-Windows for the User Locations 298, 299, 297 
    and 300, respectively.  Therefore, to continue to use Function 
    Cards 1, 2, 8 and 9 that were enrolled at startup with DL-
    Windows, be sure to enroll the same Function Cards 1, 2, 8 
    and 9 used at startup into the correct locations within DL-
    Windows.   
     
    In addition, Function Cards 3 through 7 are not recognized by DL-
    Windows.  Therefore, DL-Windows will not send the data for 
    Function Cards 3-7 to the AL-DTM, nor will the AL-DTM be able 
    to send this Function Card data to the PL3000 lock.  Accordingly, 
    Function Cards are designed to be used for limited-use installa-
    tions where DL-Windows will not be used (or is not available).  If 
    DL-Windows is used, Function Cards 3-7 will most likely never be used.  The advantage of the PL3000 lock is that it is designed to 
    be flexible for any application.   
     
    Who are Users 297-300? 
    Proximity cards assigned to User Numbers 297, 298, 299 and 
    300 have special abilities, as follows: 
     User 297 (Function Card #8):  Quick Enable User 300 
    Function Card #8 (assigned to User 297) possesses the unique 
    ability to enable Function Card #9 (assigned to User 300).  
    When Function Card #8 is presented to the lock, User 300 is 
    enabled, allowing Function Card #9 to unlock the PL3000 (for 
    one time).  Once used, Function Card #9 (User 300) becomes 
    disabled. 
     For example, you wish to allow one-time access to a temporary 
    worker.  Simply present Function Card #8 to the lock and give 
    Function Card #9 to your temporary worker.  Later, when the 
    temporary worker presents Function Card #9 to the lock, the 
    PL3000 unlocks and allows access (for one time only).  If the 
    temporary worker re-presents his card, access will be denied.  
    Later, if you wish to grant the temporary worker re-access, sim-
    ply re-present Function Card #8 to the lock and Function Card 
    #9 will be re-enabled (again for one time only).   
     
    User 298 (Function Card #1):  Quick PC Communications Card  
    Presenting the proximity card for User 298 (Function Card #1) 
    initiates data to be sent to or from the lock and DL-Windows.  
    Therefore, an AL-PCI2 cable with a PC is required.   
     
    User 299 (Function Card #2):  AL-DTM Data Transfer Card 
    Presenting the card assigned to User 299 (Function Card #2) will 
    initiate data transfer with the AL-DTM.  An AL-PCI2 cable and an 
    AL-DTM (first programmed by the computer via DL-Windows) is 
    required.  Note:  This card does not unlock the lock (does not 
    allow access).   
     
    User 300 (Function Card #9):  One-Time-Only Service Card 
    This is a One-Time Only Service User Card (Function Card #9) 
    enabled by the proximity card assigned to User 297 (Function 
    Card #8).  For example, User 300 Function Card #9) is some-
    times used for guard tour duties.  See User 297:  Quick Enable 
    User 300 above.   
     
     
    What is DL-Windows? 
    DL-Windows is a computer program that allows you to program 
    your ALARM LOCK T3 Security Lock.  You do not need DL-
    Windows to program your lock, but it makes programming much 
    faster and easier.  With DL-Windows, you can quickly create Lock 
    Programs (programs that make the lock perform its many func-
    tions) add multiple Users (who have access), add ProxCards
    ® and 
    ProxKey® keyfobs, retrieve event logs, and create Schedules.  The 
    benefit of DL-W indows is that it allows you to set up all lock pro-
    gramming in advance (on your computer), and then later send the 
    information to the locks at your convenience.  For more informa-
    tion, see OI237.   
    Terminology Used in this Manual (contd)  
    						
    							8 
    Default User Numbers for PL3000 
    USER TYPE  ASSIGNED TO  
    USER NUMBER: 
    (Not Used--The PL3000 does not contain a Master Number)  1 
    Basic User Cards (Accessible through DL-Windows only) with 
    no Entry Delay  2 - 11 
    Quick Enable User 300 (Function Card #8)  297 
    Quick PC Communications Card (Function Card #1)  298 
    AL-DTM Data Transfer Card (Function Card #2)  299 
    One-Time-Only Service Card (Function Card #9)  300 
    Basic User Cards  301-2000  Basic User Cards (Accessible through DL-Windows only)  12 - 296 
    •Users 2-296 can only be accessed through DL-Windows. 
    •User 298 is the only code that will initiate PC communications (with DL-Windows). 
    •User 299 is a Non-Pass Code (does not unlock the PL3000).  This is the only code that will initiate data transfer with 
    the AL-DTM. 
    NOTES:  
    Default User Numbers  
    The table below displays a graphical representation of how 
    the internal memory of the PL3000 lock is organized.  The 
    default settings are the original settings that were set at the 
    factory (the locks original factory condition when the lock 
    was first taken out of its box).  The default settings are per-
    manently encoded within the locks fixed memory, and when 
    the lock is first started, or when power is removed and re-applied (see Wiring and Power-Up, page 11), the original 
    factory default settings are re-loaded and take effect.   
     
    For more information, see the explanations for User Num-
    bers in the Terminology Used in this Manual section on 
    pages 6-7.  
    						
    							9 
    ACTIVITY LED SOUNDER COMMENTS 
    Access Granted  
    or  
    Remote Release 2 GREEN Flashes 2 Beeps  
    Invalid Card 7 RED Flashes 7 Beeps Invalid Card = A card that does not 
    exist in the Lock Program 
    (memory). 
    Valid but Disabled Card 1 GREEN, 4 RED 
    Flashes 1 long, 5 short 
    beeps Card exists in memory, but dis-
    abled. 
    Low Battery -- 4-second continu-
    ous beep See page 11 before changing bat-
    teries. 
    User Card Error RED Flash Sequence of 7 
    beeps repeated 4 
    times  Non-fatal memory or clock error 
    has been detected.  Under this 
    condition, unexpected operation is 
    possible.  Remove power and re-
    start. 
    LED and Sounder Indicators 
    The PL Series locks provide visual and audible feedback.  With a fully charged battery, the LED and sounder feed-
    back is as follows:  
    						
    							10 
    DB9 to DB9 Serial 
    Cable (supplied) 
    Scenario 3   Enroll ProxCards® quickly into DL-Windows, then transfer this new ProxCard® data from the computer through the AL-PRE 
    to the lock (thus avoiding the need to use an AL-PCI2 cable).  For PDL and PL series locks only.  You must always use Function Card 
    #2 to send and receive data using DL-Windows and the AL-PRE. 
    IBM COMPATABLE  
    LAPTOP OR DESKTOP PC 
    CONNECT DB9 CABLE 
    TO COMPUTER SERIAL 
    PORT (COM 1-4) 
    AL-PRE PROXCARD READER/
    ENROLLER 
    NOTE:  OBSERVE TAB DIREC-
    TION WHEN INSERTING CABLE 
    INTO AL-PRE AND LOCK 
    DOUBLE-ENDED MINI BANANA 
    PLUG CONNECTOR 
    PL3000 LOCK 
    Scenario 1   Create the program in DL-Windows on your computer, then transfer the program from the computer directly to the lock via an 
    AL-PCI2 cable.  You must always use Function Card #1 to send or receive data Using DL-Windows. 
    IBM COMPATABLE  
    LAPTOP OR DESKTOP PC 
    NOTE:  OBSERVE TAB DIRECTION W HEN 
    INSERTING CABLE INTO LOCK 
    AL-PCI2 CABLE 
    CONNECT TO SERIAL PORT 
    (COM 1-4) 
    PL3000 LOCK 
    Scenario 2   Create the program in DL-Windows and transfer the program from your computer to an AL-DTM (via an AL-PCI2 cable)
    …then transfer the program from the AL-DTM to the lock(s) (via a double-ended mini banana plug).  The hand-held AL-DTM is 
    useful because you do not have to transport (or find electricity for) your computer.  Data can also flow in reverse, from the lock, 
    through the AL-DTM, back to the computer for examination.  You must always use Function Card #2 to send and receive data us-
    ing DL-Windows and the AL-DTM. 
    IBM COMPATABLE  
    LAPTOP OR DESKTOP PC 
    NOTE:  OBSERVE TAB DIRECTION W HEN 
    INSERTING CABLE INTO LOCK 
    AL-PCI2 CABLE 
    CONNECT TO SERIAL PORT 
    (COM 1-4) 
    AL-DTM DATA 
    TRANSFER 
    MODULE 
    NOTE:  OBSERVE TAB DIREC-
    TION WHEN INSERTING CABLE 
    INTO AL-DTM AND LOCK 
    DOUBLE-ENDED MINI BANANA 
    PLUG CONNECTOR 
    PL3000 LOCK 
    Product Communication Examples 
    Send to lock Receive from lock 
    Scenario 4   Use the AL-IR1 Infrared printer to print your lock’s audit trail (event log), clock settings and software version.  No ca-
    ble required.  You must always use Function Card #6 to print.   
    PL3000 LOCK AL-IR1  
    INFRARED PRINTER 
    NOTE:  
    The AL-PCI2 cable is designed to be used on a 9 pin serial COM port.  If your computer has a 25 pin COM port, a 25 pin to 9 pin adapter must be used.   
    Warning:  Polarity MUST be observed when connecting cables to the lock.  The tab (–) must plug into the negative (black) hole.  
    						
    All Alarm Lock manuals Comments (0)