■ Mounting
IS-DV (surface-mount)
ABCDEFG
IS-DVF (fl ush-mount), IS-SS (fl ush-mount)
e.g.) IS-DVF
Special 
screwdriver
(included) Loosen
Tighten
Vandal-resistant 
front panel
81 mm (3-1/4)
194 mm (7-11/16)
Water escape holes
Do not block the holes.
Ø 6 mm
(Ø 1/4)35 mm
(1-3/8)
Anchor x 4 
(included)Screw mounting 
hole x 4
To insertion openingTo  
insertion 
opening
NOTE
Make room for threading a screw.
1  Peel off the protective seals on the plate (both sides).
2  Fill in the name on the transparent...

Page 22

22
■ Connections (IS-DV and IS-DVF)
D
NOCOMNC
PT300m (980)
D1D4
CAT5e/6
300m (980)
D1D8
CAT5e/6φ0.65-1.2mm 
(22-16 AWG)
10m (33)
φ0.65-1.2mm 
(22-16 AWG)
10m (33) φ0.65-1.2mm 
(22-16 AWG)
10m (33)
*1: Output specifi cations
Output method N/O or N/C dry closure contact
Voltage between
terminals24V AC, 0.5A (resistive load)
24V DC, 0.5A (resistive load)
Minimum overload (AC/DC): 
100mV, 0.1mA
NOTES:
Do not use the unoccupied terminals and ports for other purposes.
In order to prevent miswiring, label both...

Page 23

23
■ Connections (IS-SS)
D
NCCOMNO
PT300m (980)
D1D4
CAT5e/6
300m (980)D1D8
CAT5e/6
300m (980)C1C30
CAT5e/6
φ0.65-1.2mm 
(22-16 AWG)
10m (33)
φ0.65-1.2mm 
(22-16 AWG)
10m (33) φ0.65-1.2mm 
(22-16 AWG)
10m (33)
*1: Output specifi cations
Output method N/O or N/C dry closure contact
Voltage between
terminals24V AC, 0.5A (resistive load)
24V DC, 0.5A (resistive load)
Minimum overload (AC/DC): 
100mV, 0.1mA
NOTES:
Do not use the unoccupied terminals and ports for other purposes.
In order to prevent miswiring,...

Page 24

24
Room sub station (IS-RS)
■ Accessories
~Mounting bracket × 1
~Screw (for gang box) × 2
~Screw (for wall-mounting) × 2
~China RoHS paper × 1
~Tie-wrap × 1
■ Mounting


When a 1-gang box is not mounted, the cable and wires can be routed to the top of the unit. Cut a cable inlet on the upper part of 
the unit to allow passage of the wiring into the unit.
Mounting bracket (attached to the unit with shipment)
83.5 mm 
(3-5/16)Cable inlet The unit
Screw (for gang box) × 2 (included)
Screw (for...

Page 25

25
■ Connections
C
SP
SP
S
SE
NO
COM
PAGING
CONTACT
IN
CONTACT
OUT
150m (490)D1D4
CAT5e/6
150m (490)D1D8
CAT5e/6
150m (490)C1C30
CAT5e/6
2C2CP
NP2Cφ0.65-1.2mm 
(22-16 AWG)
15m (50)φ0.65-1.2mm 
(22-16 AWG)
15m (50)φ0.65-1.2mm 
(22-16 AWG)
15m (50)
*1: Output specifi cations
Output method N/O dry closure contact
Voltage between
terminals24V AC, 0.5A (resistive load)
24V DC, 0.5A (resistive load)
Minimum overload (AC/DC): 
100mV, 0.1mA
   
*2: Input specifi cations
Input method N/O or N/C dry closure contact...

Page 26

26
Power supply unit (IS-PU-UL and IS-PU-S)
■ Accessories
~AC cord × 1 (included in the package of this power supply unit)
~Precaution & mounting instruction sheet (paper) × 1
~China RoHS paper × 1 (IS-PU-S only)
■ Mounting
■ AC cord requirements
Type: Must comply with requirements set out by the Safety Approval/Certifi cation Organization in each country of use.• 
Employ a plug in style and ratings matched with AC outlet to be used.• 
Model 
namePlug confi guration UsageNominal voltage & 
current...

Page 27

27
TECHNICAL DATA AND PRECAUTIONS
Technical data
Operating temperature:• 
Control unit (IS-CCU, IS-SCU, IS-RCU, IS-IPC),
Master station (IS-MV), Room sub station (IS-RS), 
Power supply unit (IS-PU-UL, IS-PU-S)0 - 40°C (+32°F - +104°F)
Door station (IS-DV, IS-DVF, IS-SS) -10 - 60°C (+14°F - +140°F)
Dimensions:
• 
Control unit (IS-CCU, IS-SCU, IS-RCU, IS-IPC) 425 (W) x 88 (H) x 280 (D) mm
16-3/4 (W) x 3-1/2 (H) x 11-1/16 (D)
Color monitor master station (IS-MV) 250 (W) x 189 (H) x 59 (D) mm
9-7/8 (W) x...

Page 28

AIPHONE CO., LTD., NAGOYA, JAPAN
AIPHONE CORPORATION, BELLEVUE, WA, USA
AIPHONE S.A.S., LISSES-EVRY, FRANCE
http://www.aiphone.net/
WARRANTY
Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a period of two 
years after delivery to the ultimate user and will repair free of charge or replace at no charge, should it become defective upon which 
examination shall disclose to be defective and under warranty. Aiphone reserves unto itself the...
Start reading Aiphone IS Series Installation Manual

Related Manuals for Aiphone IS Series Installation Manual

All Aiphone manuals