Aiphone IS Series Installation Manual
Have a look at the manual Aiphone IS Series Installation Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 161 Aiphone manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
21 ■ Mounting IS-DV (surface-mount) ABCDEFG IS-DVF (fl ush-mount), IS-SS (fl ush-mount) e.g.) IS-DVF Special screwdriver (included) Loosen Tighten Vandal-resistant front panel 81 mm (3-1/4) 194 mm (7-11/16) Water escape holes Do not block the holes. Ø 6 mm (Ø 1/4)35 mm (1-3/8) Anchor x 4 (included)Screw mounting hole x 4 To insertion openingTo insertion opening NOTE Make room for threading a screw. 1 Peel off the protective seals on the plate (both sides). 2 Fill in the name on the transparent name plate. Be sure to leave 25 mm (1) of white space on the right end to account for insertion. 3 Insert the fi lled-in transparent name plate at the specifi ed insertion opening (indicated with in diagram). 2 mm (1/8)25 mm (1) Mounting height GL=1,500 mm (5) Tighten Special screw x 4 (included) Vandal-resistant front panel with the unit attachedFlush mount back box (included) Transparent name plate45 mm (1-13/16) 120 mm (4-3/4) 235 mm (9-5/16) 90 mm (3-9/16) 25 mm (1) 25 mm (1) Unit center Unit center The unit Screw (for wall-mounting) × 4 (included) Loosen the screw 1 with the special screwdriver, and remove the front panel. Insert the transparent name plate. 2 (IS-DV and IS-DVF)Open the terminal cover, and 3 connect the CAT5e/6 cable and option wires to the unit. Fasten the unit to the 4 mounting surface. Use board anchors or concrete * plugs as needed. Attach the front panel to the unit by 5 hanging the upper 2 parts on the unit. Tighten the screw with the lower part of * the front panel pressed to the wall. Mounting height (box center) GL=1,500 mm (5)Loosen Special screwdriver (included) Install the back box in the wall, and 1 then connect the CAT5e/6 cable and option wires to the unit with the terminal cover open. Insert the transparent name plate. (IS-DVF only) 2 See above for details.* Fasten the front panel to the 3 back box with the special screws. Option wires CAT5e/6 cable
22 ■ Connections (IS-DV and IS-DVF) D NOCOMNC PT300m (980) D1D4 CAT5e/6 300m (980) D1D8 CAT5e/6φ0.65-1.2mm (22-16 AWG) 10m (33) φ0.65-1.2mm (22-16 AWG) 10m (33) φ0.65-1.2mm (22-16 AWG) 10m (33) *1: Output specifi cations Output method N/O or N/C dry closure contact Voltage between terminals24V AC, 0.5A (resistive load) 24V DC, 0.5A (resistive load) Minimum overload (AC/DC): 100mV, 0.1mA NOTES: Do not use the unoccupied terminals and ports for other purposes. In order to prevent miswiring, label both ends of each cable with the unit and terminal names to which they are to be connected. For connecting other manufacture’s products, refer to the instruction manuals for those products. The illustration of the unit’s rear panel differs from the actual one. This is for simplifying the connection diagram. Central control unit (IS-CCU) Add-on control unit (IS-SCU) AC transformer or The terminals are inside the terminal * cover. After connecting, route the wires through the wiring paths, then close the cover. Be sure to route the CAT5e/6 cable * and option wires through inlet. When closing the terminal cover, * close it until it clicks. Electric door strike *1(non-shielded) (non-shielded)(Select one port.) (Select one port.) Terminal cover InletCAT5e/6 cableOption wires Connect to the electric door strike * according to its specifi cations.
23 ■ Connections (IS-SS) D NCCOMNO PT300m (980) D1D4 CAT5e/6 300m (980)D1D8 CAT5e/6 300m (980)C1C30 CAT5e/6 φ0.65-1.2mm (22-16 AWG) 10m (33) φ0.65-1.2mm (22-16 AWG) 10m (33) φ0.65-1.2mm (22-16 AWG) 10m (33) *1: Output specifi cations Output method N/O or N/C dry closure contact Voltage between terminals24V AC, 0.5A (resistive load) 24V DC, 0.5A (resistive load) Minimum overload (AC/DC): 100mV, 0.1mA NOTES: Do not use the unoccupied terminals and ports for other purposes. In order to prevent miswiring, label both ends of each cable with the unit and terminal names to which they are to be connected. For connecting other manufacture’s products, refer to the instruction manuals for those products. The illustration of the unit’s rear panel differs from the actual one. This is for simplifying the connection diagram. Terminal coverCAT5e/6 cable Central control unit (IS-CCU) Room sub control unit (IS-RCU) Add-on control unit (IS-SCU) AC transformer or or The terminals are inside the terminal * cover. After connecting, route the wires through the wiring paths, then close the cover. Be sure to route the CAT5e/6 cable * and option wires through inlet. When closing the terminal cover, * close it until it clicks. Electric door strike *1(non-shielded) (non-shielded) (non-shielded)(Select one port.) (Select one port.) (Select one port.) Connect to the electric * door strike according to its specifi cations. InletOption wires
24 Room sub station (IS-RS) ■ Accessories ~Mounting bracket × 1 ~Screw (for gang box) × 2 ~Screw (for wall-mounting) × 2 ~China RoHS paper × 1 ~Tie-wrap × 1 ■ Mounting When a 1-gang box is not mounted, the cable and wires can be routed to the top of the unit. Cut a cable inlet on the upper part of the unit to allow passage of the wiring into the unit. Mounting bracket (attached to the unit with shipment) 83.5 mm (3-5/16)Cable inlet The unit Screw (for gang box) × 2 (included) Screw (for wall-mounting) × 2 (included)1-gang box Fasten the mounting 1 bracket to the wall. Connect the CAT5e/6 cable 2 and option wires to the unit. Mount the unit 3 on the mounting bracket.Option wiresCAT5e/6 cable Mounting bracket (attached to the unit with shipment) The unit
25 ■ Connections C SP SP S SE NO COM PAGING CONTACT IN CONTACT OUT 150m (490)D1D4 CAT5e/6 150m (490)D1D8 CAT5e/6 150m (490)C1C30 CAT5e/6 2C2CP NP2Cφ0.65-1.2mm (22-16 AWG) 15m (50)φ0.65-1.2mm (22-16 AWG) 15m (50)φ0.65-1.2mm (22-16 AWG) 15m (50) *1: Output specifi cations Output method N/O dry closure contact Voltage between terminals24V AC, 0.5A (resistive load) 24V DC, 0.5A (resistive load) Minimum overload (AC/DC): 100mV, 0.1mA *2: Input specifi cations Input method N/O or N/C dry closure contact (start signal only detection method) Detection confi rmation time100 ms or more Contact resistance During N/O dry closure: Less than 700 Ω During N/C dry closure: At least 4 k Ω Terminal short current Less than 10 mA Voltage between terminalsLess than 5 V DC (when open between terminals) NOTES: Do not use the unoccupied terminals and ports for other purposes. In order to prevent miswiring, label both ends of each cable with the unit and terminal names to which they are to be connected. For connecting other manufacture’s products, refer to the instruction manuals for those products. The illustration of the unit’s rear panel differs from the actual one. This is for simplifying the connection diagram. Central control unit (IS-CCU) External speaker (more than 8Ω 3W) Add-on control unit (IS-SCU) Room sub control unit (IS-RCU) or or Contact input *2(Sensor, etc.) Contact output *1(Electric door strike, strobe light, etc.) (Select one port.) (Select one port.) (Select one port.) (non-shielded) (non-shielded) (non-shielded) NP: Non-polarized P: Polarized
26 Power supply unit (IS-PU-UL and IS-PU-S) ■ Accessories ~AC cord × 1 (included in the package of this power supply unit) ~Precaution & mounting instruction sheet (paper) × 1 ~China RoHS paper × 1 (IS-PU-S only) ■ Mounting ■ AC cord requirements Type: Must comply with requirements set out by the Safety Approval/Certifi cation Organization in each country of use.• Employ a plug in style and ratings matched with AC outlet to be used.• Model namePlug confi guration UsageNominal voltage & current rating IS-PU-UL North American 125V, 10A IS-PU-S Universal European 250V, 6A Up to 3 power supply units can be * mounted on the rack.Power supply unit (IS-PU-UL, IS-PU-S) AC cord (approx.1.8m (6))AC cord inlet Rack for the power supply unit (IS-RACK) The IS-RACK is available. Consult an authorized * Aiphone dealer for details. DC output terminals Connect the power wires.1 Plug in the AC cord securely.2 The power supply unit cannot be mounted on a wall directly.• By using the IS-RACK (sold separately), the power supply unit can be set in the 19-inch rack or mounted on a wall.•
27 TECHNICAL DATA AND PRECAUTIONS Technical data Operating temperature:• Control unit (IS-CCU, IS-SCU, IS-RCU, IS-IPC), Master station (IS-MV), Room sub station (IS-RS), Power supply unit (IS-PU-UL, IS-PU-S)0 - 40°C (+32°F - +104°F) Door station (IS-DV, IS-DVF, IS-SS) -10 - 60°C (+14°F - +140°F) Dimensions: • Control unit (IS-CCU, IS-SCU, IS-RCU, IS-IPC) 425 (W) x 88 (H) x 280 (D) mm 16-3/4 (W) x 3-1/2 (H) x 11-1/16 (D) Color monitor master station (IS-MV) 250 (W) x 189 (H) x 59 (D) mm 9-7/8 (W) x 7-1/2 (H) x 2-3/8 (D) Vandal-resistant video door station (IS-DV) 105 (W) x 215 (H) x 32 (D) mm 4-3/16 (W) x 8-1/2 (H) x 1-5/16 (D) Vandal-resistant video door station (IS-DVF)IS-DVF 150 (W) x 265 (H) x 38 (D) mm 5-15/16 (W) x 10-7/16 (H) x 1-1/2 (D) Flush mount back box 120 (W) x 235 (H) x 45 (D) mm 4-3/4 (W) x 9-5/16 (H) x 1-13/16 (D) Vandal-resistant audio door station (IS-SS)IS-SS 150 (W) x 265 (H) x 32 (D) mm 5-15/16 (W) x 10-7/16 (H) x 1-5/16 (D) Flush mount back box 120 (W) x 235 (H) x 45 (D) mm 4-3/4 (W) x 9-5/16 (H) x 1-13/16 (D) Room sub station (IS-RS) 116.5 (W) x 199 (H) x 64 (D) mm 4-5/8 (W) x 7-7/8 (H) x 2-9/16 (D) Power supply unit (IS-PU-UL, IS-PU-S) 130 (W) x 265 (H) x 83 (D) mm 5-1/8 (W) x 10-7/16 (H) x 3-5/16 (D) Weight: • Control unit (IS-CCU, IS-SCU, IS-RCU) Approx. 4.0 kg (8.82 lbs.) IP control unit (IS-IPC) Approx. 3.6 kg (7.94 lbs.) Color monitor master station (IS-MV) Approx. 820 g (1.81 lbs.) Vandal-resistant video door station (IS-DV) Approx. 520 g (1.15 lbs.) Vandal-resistant video door station (IS-DVF)IS-DVF Approx. 810 g (1.79 lbs.) Flush mount back box Approx. 600 g (1.32 lbs.) Vandal-resistant audio door station (IS-SS)IS-SS Approx. 820 g (1.81 lbs.) Flush mount back box Approx. 600 g (1.32 lbs.) Room sub station (IS-RS) Approx. 530 g (1.17 lbs.) Power supply unit (IS-PU-UL, IS-PU-S) Approx. 1.5 kg (3.31 lbs.) Technical precautions Cleaning: Clean the units with a soft cloth dampened with a neutral household cleanser. Do not use an abrasive cleanser or cloth.•
AIPHONE CO., LTD., NAGOYA, JAPAN AIPHONE CORPORATION, BELLEVUE, WA, USA AIPHONE S.A.S., LISSES-EVRY, FRANCE http://www.aiphone.net/ WARRANTY Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a period of two years after delivery to the ultimate user and will repair free of charge or replace at no charge, should it become defective upon which examination shall disclose to be defective and under warranty. Aiphone reserves unto itself the sole right to make the fi nal decision whether there is a defect in materials and/or workmanship; and whether or not the product is within the warranty. This warranty shall not apply to any Aiphone product which has been subject to misuse, neglect, accident, power surge, or to use in violation of instructions furnished, nor extended to units which have been repaired or altered outside of the factory. This warranty does not cover batteries or damage caused by batteries used in connection with the unit. This warranty covers bench repairs only, and any repairs must be made at the shop or place designated in writing by Aiphone. Aiphone will not be responsible for any costs incurred involving on site service calls. Aiphone will not provide compensation for any loss or damage incurred by the breakdown or malfunction of its products during use, or for any consequent inconvenience or losses that may result. The object area of is the EU. FCC This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. Increase the separation • between the equipment and receiver. Consult the dealer or an experienced radio/TV technician for help. • Printed in Japan