    ■ Mounting
    IS-DV (surface-mount)
    ABCDEFG
    IS-DVF (fl ush-mount), IS-SS (fl ush-mount)
    e.g.) IS-DVF
    Special 
    screwdriver
    (included) Loosen
    Tighten
    Vandal-resistant 
    front panel
    81 mm (3-1/4)
    194 mm (7-11/16)
    Water escape holes
    Do not block the holes.
    Ø 6 mm
    (Ø 1/4)35 mm
    (1-3/8)
    Anchor x 4 
    (included)Screw mounting 
    hole x 4
    To insertion openingTo  
    insertion 
    opening
    NOTE
    Make room for threading a screw.
    1  Peel off the protective seals on the plate (both sides).
    2  Fill in the name on the transparent name plate.
     Be sure to leave 25 mm (1) of white space on the 
    right end to account for insertion.
    3 Insert the fi lled-in transparent name plate at the 
    specifi ed insertion opening (indicated with 
     in 
    diagram).
    2 mm (1/8)25 mm
    (1)
    Mounting height
    GL=1,500 mm (5)
    Tighten
    Special screw x 4 
    (included) Vandal-resistant front panel with the unit attachedFlush mount back box (included)
    Transparent name plate45 mm
    (1-13/16) 120 mm
    (4-3/4)
    235 mm
    (9-5/16)
    90 mm (3-9/16) 
    25 mm (1) 
    25 mm (1) 
    Unit center
    Unit 
    center
    The unit
    Screw (for wall-mounting) × 4 
    (included)
    Loosen the screw 1 with the special 
    screwdriver, and 
    remove the front 
    panel.
    Insert the transparent name plate.
    2 (IS-DV and IS-DVF)Open the terminal cover, and 
    3 connect the CAT5e/6 cable and 
    option wires to the unit. Fasten the unit to the 
    4 mounting surface.
    Use board anchors or concrete * plugs as needed.
    Attach the front panel to the unit by 5 hanging the upper 2 parts on the unit.
    Tighten the screw with the lower part of * the front panel pressed to the wall.
    Mounting height (box center)
    GL=1,500 mm (5)Loosen
    Special screwdriver
    (included)
    Install the back box in the wall, and 1 then connect the CAT5e/6 cable 
    and option wires to the unit with the 
    terminal cover open.
    Insert the transparent name plate. (IS-DVF only)
    2 See above for details.* 
    Fasten the front panel to the 3 back box with the special screws.
    Option wires
    CAT5e/6 cable 
    						
    							22
    ■ Connections (IS-DV and IS-DVF)
    D
    NOCOMNC
    PT300m (980)
    D1D4
    CAT5e/6
    300m (980)
    D1D8
    CAT5e/6φ0.65-1.2mm 
    (22-16 AWG)
    10m (33)
    φ0.65-1.2mm 
    (22-16 AWG)
    10m (33) φ0.65-1.2mm 
    (22-16 AWG)
    10m (33)
    *1: Output specifi cations
    Output method N/O or N/C dry closure contact
    Voltage between
    terminals24V AC, 0.5A (resistive load)
    24V DC, 0.5A (resistive load)
    Minimum overload (AC/DC): 
    100mV, 0.1mA
    NOTES:
    Do not use the unoccupied terminals and ports for other purposes.
    In order to prevent miswiring, label both ends of each cable with the unit and terminal names to which they are to be connected.
    For connecting other manufacture’s products, refer to the instruction manuals for those products.
    The illustration of the unit’s rear panel differs from the actual one. This is for simplifying the connection diagram.
    Central control unit 
    (IS-CCU)
    Add-on control unit 
    (IS-SCU) AC transformer
    or
    The terminals are inside the terminal * 
    cover. After connecting, route the 
    wires through the wiring paths, then 
    close the cover.
    Be sure to route the CAT5e/6 cable 
    * 
    and option wires through inlet.
    When closing the terminal cover, 
    * 
    close it until it clicks.
    Electric door strike *1(non-shielded)
    (non-shielded)(Select one port.)
    (Select one port.)
    Terminal cover InletCAT5e/6 cableOption 
    wires
    Connect to the electric door strike * 
    according to its specifi cations. 
    						
    							23
    ■ Connections (IS-SS)
    D
    NCCOMNO
    PT300m (980)
    D1D4
    CAT5e/6
    300m (980)D1D8
    CAT5e/6
    300m (980)C1C30
    CAT5e/6
    φ0.65-1.2mm 
    (22-16 AWG)
    10m (33)
    φ0.65-1.2mm 
    (22-16 AWG)
    10m (33) φ0.65-1.2mm 
    (22-16 AWG)
    10m (33)
    *1: Output specifi cations
    Output method N/O or N/C dry closure contact
    Voltage between
    terminals24V AC, 0.5A (resistive load)
    24V DC, 0.5A (resistive load)
    Minimum overload (AC/DC): 
    100mV, 0.1mA
    NOTES:
    Do not use the unoccupied terminals and ports for other purposes.
    In order to prevent miswiring, label both ends of each cable with the unit and terminal names to which they are to be connected.
    For connecting other manufacture’s products, refer to the instruction manuals for those products.
    The illustration of the unit’s rear panel differs from the actual one. This is for simplifying the connection diagram.
    Terminal coverCAT5e/6 cable
    Central control unit 
    (IS-CCU)
    Room sub control unit 
    (IS-RCU) Add-on control unit 
    (IS-SCU) AC transformer
    or or
    The terminals are inside the terminal * 
    cover. After connecting, route the 
    wires through the wiring paths, then 
    close the cover.
    Be sure to route the CAT5e/6 cable 
    * 
    and option wires through inlet.
    When closing the terminal cover, 
    * 
    close it until it clicks.
    Electric door strike *1(non-shielded)
    (non-shielded)
    (non-shielded)(Select one port.)
    (Select one port.)
    (Select one port.)
    Connect to the electric * 
    door strike according to its 
    specifi cations.
    InletOption 
    wires 
    						
    							24
    Room sub station (IS-RS)
    ■ Accessories
    ~Mounting bracket × 1
    ~Screw (for gang box) × 2
    ~Screw (for wall-mounting) × 2
    ~China RoHS paper × 1
    ~Tie-wrap × 1
    ■ Mounting
    
    
    When a 1-gang box is not mounted, the cable and wires can be routed to the top of the unit. Cut a cable inlet on the upper part of 
    the unit to allow passage of the wiring into the unit.
    Mounting bracket (attached to the unit with shipment)
    83.5 mm 
    (3-5/16)Cable inlet The unit
    Screw (for gang box) × 2 (included)
    Screw (for wall-mounting) × 2 (included)1-gang box
    Fasten the mounting 1 bracket to the wall.
    Connect the CAT5e/6 cable 
    2 and option wires to the unit. Mount the unit 
    3 on the mounting 
    bracket.Option wiresCAT5e/6 cable
    Mounting bracket 
    (attached to the unit with shipment)
    The unit 
    						
    							25
    ■ Connections
    C
    SP
    SP
    S
    SE
    NO
    COM
    PAGING
    CONTACT
    IN
    CONTACT
    OUT
    150m (490)D1D4
    CAT5e/6
    150m (490)D1D8
    CAT5e/6
    150m (490)C1C30
    CAT5e/6
    2C2CP
    NP2Cφ0.65-1.2mm 
    (22-16 AWG)
    15m (50)φ0.65-1.2mm 
    (22-16 AWG)
    15m (50)φ0.65-1.2mm 
    (22-16 AWG)
    15m (50)
    *1: Output specifi cations
    Output method N/O dry closure contact
    Voltage between
    terminals24V AC, 0.5A (resistive load)
    24V DC, 0.5A (resistive load)
    Minimum overload (AC/DC): 
    100mV, 0.1mA
       
    *2: Input specifi cations
    Input method N/O or N/C dry closure contact (start
    signal only detection method)
    Detection confi rmation 
    time100 ms or more
    Contact resistance During N/O dry closure: Less than 700 Ω
    During N/C dry closure: At least 4 k Ω
    Terminal short current Less than 10 mA
    Voltage between
    terminalsLess than 5 V DC (when open between
    terminals)
    NOTES:
    Do not use the unoccupied terminals and ports for other purposes.
    In order to prevent miswiring, label both ends of each cable with the unit and terminal names to which they are to be connected.
    For connecting other manufacture’s products, refer to the instruction manuals for those products.
    The illustration of the unit’s rear panel differs from the actual one. This is for simplifying the connection diagram.
    Central control unit 
    (IS-CCU)
    External speaker 
    (more than 8Ω 3W)
    Add-on control unit 
    (IS-SCU)
    Room sub control unit 
    (IS-RCU)
    or
    or
    Contact input *2(Sensor, etc.) Contact output 
    *1(Electric door strike, 
    strobe light, etc.)
    (Select one port.)
    (Select one port.)
    (Select one port.) (non-shielded)
    (non-shielded)
    (non-shielded)
    NP: Non-polarized
    P: Polarized 
    						
    							26
    Power supply unit (IS-PU-UL and IS-PU-S)
    ■ Accessories
    ~AC cord × 1 (included in the package of this power supply unit)
    ~Precaution & mounting instruction sheet (paper) × 1
    ~China RoHS paper × 1 (IS-PU-S only)
    ■ Mounting
    ■ AC cord requirements
    Type: Must comply with requirements set out by the Safety Approval/Certifi cation Organization in each country of use.• 
    Employ a plug in style and ratings matched with AC outlet to be used.• 
    Model 
    namePlug confi guration UsageNominal voltage & 
    current rating
    IS-PU-UL
    North American 125V,  10A
    IS-PU-S
    Universal European 250V, 6A
    Up to 3 power supply units can be  * 
    mounted on the rack.Power supply unit
    (IS-PU-UL, IS-PU-S)
    AC cord 
    (approx.1.8m (6))AC cord inlet
    Rack for the power supply unit (IS-RACK)
    The IS-RACK is available. Consult an authorized  * 
    Aiphone dealer for details. DC output terminals
    Connect the power wires.1 
    Plug in the AC cord securely.2 
    The power supply unit cannot be mounted on a wall directly.• 
    By using the IS-RACK (sold separately), the power supply unit can be set in the 19-inch rack or mounted on a wall.•  
    						
    							27
    TECHNICAL DATA AND PRECAUTIONS
    Technical data
    Operating temperature:• 
    Control unit (IS-CCU, IS-SCU, IS-RCU, IS-IPC),
    Master station (IS-MV), Room sub station (IS-RS), 
    Power supply unit (IS-PU-UL, IS-PU-S)0 - 40°C (+32°F - +104°F)
    Door station (IS-DV, IS-DVF, IS-SS) -10 - 60°C (+14°F - +140°F)
    Dimensions:
    • 
    Control unit (IS-CCU, IS-SCU, IS-RCU, IS-IPC) 425 (W) x 88 (H) x 280 (D) mm
    16-3/4 (W) x 3-1/2 (H) x 11-1/16 (D)
    Color monitor master station (IS-MV) 250 (W) x 189 (H) x 59 (D) mm
    9-7/8 (W) x 7-1/2 (H) x 2-3/8 (D)
    Vandal-resistant video door station (IS-DV) 105 (W) x 215 (H) x 32 (D) mm
    4-3/16 (W) x 8-1/2 (H) x 1-5/16 (D)
    Vandal-resistant video door 
    station (IS-DVF)IS-DVF 150 (W) x 265 (H) x 38 (D) mm
    5-15/16 (W) x 10-7/16 (H) x 1-1/2 (D)
    Flush mount back box 120 (W) x 235 (H) x 45 (D) mm
    4-3/4 (W) x 9-5/16 (H) x 1-13/16 (D)
    Vandal-resistant audio door 
    station (IS-SS)IS-SS 150 (W) x 265 (H) x 32 (D) mm
    5-15/16 (W) x 10-7/16 (H) x 1-5/16 (D)
    Flush mount back box 120 (W) x 235 (H) x 45 (D) mm
    4-3/4 (W) x 9-5/16 (H) x 1-13/16 (D)
    Room sub station (IS-RS) 116.5 (W) x 199 (H) x 64 (D) mm
    4-5/8 (W) x 7-7/8 (H) x 2-9/16 (D)
    Power supply unit (IS-PU-UL, IS-PU-S) 130 (W) x 265 (H) x 83 (D) mm
    5-1/8 (W) x 10-7/16 (H) x 3-5/16 (D)
    Weight:
    • 
    Control unit (IS-CCU, IS-SCU, IS-RCU) Approx. 4.0 kg (8.82 lbs.)
    IP control unit (IS-IPC) Approx. 3.6 kg (7.94 lbs.)
    Color monitor master station (IS-MV) Approx. 820 g (1.81 lbs.)
    Vandal-resistant video door station (IS-DV) Approx. 520 g (1.15 lbs.)
    Vandal-resistant video door 
    station (IS-DVF)IS-DVF Approx. 810 g (1.79 lbs.)
    Flush mount back box Approx. 600 g (1.32 lbs.)
    Vandal-resistant audio door 
    station (IS-SS)IS-SS Approx. 820 g (1.81 lbs.)
    Flush mount back box Approx. 600 g (1.32 lbs.)
    Room sub station (IS-RS) Approx. 530 g (1.17 lbs.)
    Power supply unit (IS-PU-UL, IS-PU-S) Approx. 1.5 kg (3.31 lbs.)
    Technical precautions
    Cleaning: Clean the units with a soft cloth dampened with a neutral household cleanser. Do not use an abrasive cleanser or cloth.•  
    						
    							AIPHONE CO., LTD., NAGOYA, JAPAN
    AIPHONE CORPORATION, BELLEVUE, WA, USA
    AIPHONE S.A.S., LISSES-EVRY, FRANCE
    http://www.aiphone.net/
    WARRANTY
    Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a period of two 
    years after delivery to the ultimate user and will repair free of charge or replace at no charge, should it become defective upon which 
    examination shall disclose to be defective and under warranty. Aiphone reserves unto itself the sole right to make the fi nal decision 
    whether there is a defect in materials and/or workmanship; and whether or not the product is within the warranty. This warranty 
    shall not apply to any Aiphone product which has been subject to misuse, neglect, accident, power surge, or to use in violation of 
    instructions furnished, nor extended to units which have been repaired or altered outside of the factory. This warranty does not cover 
    batteries or damage caused by batteries used in connection with the unit. This warranty covers bench repairs only, and any repairs 
    must be made at the shop or place designated in writing by Aiphone. Aiphone will not be responsible for any costs incurred involving 
    on site service calls. Aiphone will not provide compensation for any loss or damage incurred by the breakdown or malfunction of its 
    products during use, or for any consequent inconvenience or losses that may result.
    The object area of 
     is the EU.
    FCC
    This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause 
    harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired 
    operation.
    This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. 
    These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment 
    generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may 
    cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular 
    installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the 
    equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 
    Reorient or relocate the receiving antenna
    • 