Aiphone IS Series Installation Manual
Here you can view all the pages of manual Aiphone IS Series Installation Manual. The Aiphone manuals for Telephone are available online for free. You can easily download all the documents as PDF.
Page 11
11 ■ Connections 1CX1 1CX2M1 M21MX1 1MX21MX3 2MX12MX2 2MX3 M3 M4D1 D2IP1LAN IP2 IP3 D3 D4 2CX1 2CX23CX1 3CX24CX1 4CX2 P1P2P3P4L1L2L3L4L5L6L7L8S1 E S2 E S3 E S4 E IS-RCUMASTER STATIONIS-SCUIS-IPC DC48V DOOR/SUB STATIONVIDEO/AUDIO PA OUTPUT (600Ω)CONTACT INPUTCHIME INPUT (600Ω)ETHERNETVIDEO OUTPUTCONTACT OUTPUT (AC/DC24V 0.5A) B2B1 V1 V2 CAT5e/6 200m (650)CAT5e/6 200m (650)CAT5e/6 300m (980)CAT5e/6 300m (980) 10m (33)15m (50) 200m (650)CAT5e/6 150m (490)Coax 15m (50) NTSC15m (50) NTSC *2 *3 *4 *1 D C 2C...
Page 12
12 Add-on control unit ( IS-SCU) ■ Part names NOTE: The illustration of the unit may differ from the actual one. ■ Specifi cations Add-on control unit (IS-SCU) Power source 48V DC (supplied from the power supply unit) Current consumption Max. 1.2A Ambient temperature 0 - 40°C (+32°F - +104°F) Talk channels ~Video channelsLocal system: 2 talk & 2 video channels, 1 chime Master station(s) Max. 8 Video door station(s) Max. 8 Audio door station(s) Room sub station(s) Video outputNTSC BNC (Video channel...
Page 13
13 ■ Connections M1 M2M3 M4M5 M6M7 M8D1 D2MX1MX3 ID 1 2 MX2 D3 D4D5 D6D7 D8 P1P2P3P4L1L2L3L4 MASTER STATIONIS-CCU DC48V VIDEO/AUDIO DOOR/SUB STATION PA OUTPUT (600Ω)VIDEO OUTPUTCONTACT OUTPUT (AC/DC24V 0.5A) V1 V2 CAT5e/6 300m (980)CAT5e/6 300m (980) 15m(50) 200m (650)CAT5e/6 150m (490)Coax 15m (50) NTSC15m (50) NTSC *1 DC 2C M 1MX11MX21MX3 CoaxPT *2 φ0.8-1.2mm (20-16 AWG)CAT5e/6 (x3) BNC connector BNC connector BNC connectorBNC connector P NP 2C φ0.65-1.2mm (22-16 AWG) 15m (50) NP 2C φ0.65-1.2mm...
Page 14
14 Room sub control unit ( IS-RCU) ■ Part names NOTE: The illustration of the unit may differ from the actual one. ■ Specifi cations Room sub control unit (IS-RCU) Power source 48V DC (supplied from the power supply unit) Current consumption Max. 1.8A Ambient temperature 0 - 40°C (+32°F - +104°F) Talk channels Local system: 2 talk channels, 1 chime Audio door station(s) Room sub station(s)Max. 30 Mounting Rack-mount (19-inch, 2U rack) or wall-mount Material Steel plate Color Black CONTACT OUTPUT...
Page 15
15 ■ Connections C1 C2CX1/IP1 ID 1 2 3 4CX2/IP2 C3 C4C5 C6C7 C8C9 C10C11 C12C13 C14C15 C16C17 C18C19 C20C21 C22C23 C24C25 C26C27 C28C29 C30 P1P2P3P4L1L2L3L4 IS-CCU/ IS-IPC DC48V AUDIO DOOR/SUB STATION PA OUTPUT (600Ω)CONTACT OUTPUT (AC/DC24V 0.5A) CAT5e/6 300m (980)15m (50) 200m (650)CAT5e/6 150m (490) *1 CD 1CX11CX2 PT *2 10m (33) IP1IP2 CAT5e/6 (x2) CAT5e/6 (x2) φ0.8-1.2mm (20-16 AWG)2C P NP 2C φ0.65-1.2mm (22-16 AWG) NP 2C φ0.65-1.2mm (22-16 AWG) NP 2C φ0.65-1.2mm (22-16 AWG) 15m (50) *1: This...
Page 16
16 IP control unit ( IS-IPC) IPThis unit is needed to connect a local system to a standard (IP) system. ■ Part names NOTE: The illustration of the unit may differ from the actual one. ■ Specifi cations IP control unit (IS-IPC) Power source 48V DC (supplied from the power supply unit) Current consumption Max. 105mA Ambient temperature 0 - 40°C (+32°F - +104°F) Talk channels ~Video channels, other channels2 talk & 2 constrained video channels, 1 chime, and 1 telephone (North America only) Central...
Page 17
17 ■ Connections IP1 IP2 IP3LAN IS-RCU IS-CCU DC48V ETHERNET CO TELEPHONE 10m (33) 10m (33)15m (50) 2C IP1IP2IP3 φ0.8-1.2mm (20-16 AWG)IP1 IP2 IP3 IS-RCU IS-CCU CAT5e/6 (x3)10BASE-T 100BASE-TX 100m (330) CX1/IP1CX2/IP2 CAT5e/6 (x2) P *3 *1: When connecting a central control unit (IS-CCU) to this unit, connect it to the IP1, IP2 and IP3 ports. *2: When connecting a room sub control unit (IS-RCU) to this unit, connect it to the IP1 and IP2 ports. *3: Do not install two power supplies in parallel to a...
Page 18
18 Color monitor master station (IS-MV) For the part names and their functions, see the OPERATION MANUAL.* ■ Accessories ~Mounting bracket × 1 ~Name card × 1 ~Desktop stand × 1 ~Screw (15mm (5/8), for wall-mounting) × 4 ~Tie-wrap × 1 ~Screw (25mm (1), for gang box) × 4 ~Name plate × 1 ~Screw (10mm (7/16), for desktop stand) × 4 ~China RoHS paper × 1 ■ Mounting When mounting on a wall Mounting bracket (attached to the unit with shipment) Mounting bracket (attached to the unit with shipment)...
Page 19
19 When mounting on a desktop stand 30r 45r 60r ■ Connections M VVAA VIDEO OUTPUT AUDIO OUTPUT M1M4 CAT5e/6 Coax2C M1M8 CAT5e/6 P NP NTSC NOTES: Do not use the unoccupied terminals and ports for other purposes. In order to prevent miswiring, label both ends of each cable with the unit and terminal names to which they are to be connected. For connecting other manufacture’s products, refer to the instruction manuals for those products. The illustration of the unit’s rear panel differs from the actual one....
Page 20
20 Vandal-resistant video door station (IS-DV, IS-DVF), Vandal-resistant audio door station (IS-SS) ■ Accessories ~Screw (for wall-mounting) × 4 (IS-DV only) ~Special screwdriver × 1 ~Anchor × 4 (IS-DV only) ~Back box × 1 (IS-DVF and IS-SS only) ~Transparent name plate × 2 (IS-DV and IS-DVF only) ~China RoHS paper × 1 ~Special screw × 4 (IS-DVF and IS-SS only) ■ Mounting locations (IS-DV and IS-DVF) Do not install this unit in any of the following locations where lighting or the ambient...