Page 11

11
■ Connections
1CX1
1CX2M1
M21MX1
1MX21MX3
2MX12MX2
2MX3 M3
M4D1
D2IP1LAN
IP2 IP3 D3
D4 2CX1
2CX23CX1
3CX24CX1
4CX2
P1P2P3P4L1L2L3L4L5L6L7L8S1 E S2 E S3 E S4 E
IS-RCUMASTER STATIONIS-SCUIS-IPC
DC48V
DOOR/SUB STATIONVIDEO/AUDIO
PA OUTPUT (600Ω)CONTACT INPUTCHIME INPUT (600Ω)ETHERNETVIDEO OUTPUTCONTACT OUTPUT (AC/DC24V  0.5A)
B2B1
V1 V2
CAT5e/6
200m
(650)CAT5e/6
200m
(650)CAT5e/6
300m
(980)CAT5e/6
300m
(980)
10m (33)15m
(50)
200m
(650)CAT5e/6
150m
(490)Coax
15m (50)
NTSC15m (50)
NTSC
*2
*3
*4 *1
D C
2C...

Page 12

12
Add-on control unit (
IS-SCU)
■ Part names
NOTE:
The illustration of the unit may differ from the actual one.
■ Specifi cations
Add-on control unit (IS-SCU)
Power source 48V DC (supplied from the power supply unit)
Current consumption Max. 1.2A
Ambient temperature 0 - 40°C (+32°F - +104°F)
Talk channels
~Video 
channelsLocal system: 2 talk & 2 video channels, 
1 chime
Master station(s) Max. 8
Video door station(s)
Max. 8 Audio door station(s)
Room sub station(s)
Video outputNTSC  
BNC (Video channel...

Page 13

13
 
■ Connections
M1
M2M3
M4M5
M6M7
M8D1
D2MX1MX3
ID 1
2
MX2 D3
D4D5
D6D7
D8
P1P2P3P4L1L2L3L4
MASTER STATIONIS-CCU
DC48V
VIDEO/AUDIO DOOR/SUB STATION
PA OUTPUT (600Ω)VIDEO OUTPUTCONTACT OUTPUT (AC/DC24V  0.5A)
V1 V2
CAT5e/6
300m
(980)CAT5e/6
300m
(980)
15m(50) 200m
(650)CAT5e/6
150m
(490)Coax
15m (50)
NTSC15m (50)
NTSC
*1
DC
2C
M
1MX11MX21MX3
CoaxPT
*2
φ0.8-1.2mm 
(20-16 AWG)CAT5e/6 (x3)
BNC
connector BNC
connector
BNC
connectorBNC
connector
P NP
2C
φ0.65-1.2mm
(22-16 AWG)
15m (50)
NP
2C
φ0.65-1.2mm...

Page 14

14
Room sub control unit (
IS-RCU)
■ Part names
NOTE:
The illustration of the unit may differ from the actual one.
■ Specifi cations
Room sub control unit (IS-RCU)
Power source 48V DC (supplied from the power supply unit)
Current consumption Max. 1.8A
Ambient temperature 0 - 40°C (+32°F - +104°F)
Talk channels Local system: 2 talk channels, 1 chime
Audio door station(s)
Room sub station(s)Max. 30
Mounting Rack-mount (19-inch, 2U rack) or wall-mount
Material Steel plate
Color Black
CONTACT OUTPUT...

Page 15

15
■ Connections 
C1
C2CX1/IP1
ID 1
2
3
4CX2/IP2
C3
C4C5
C6C7
C8C9
C10C11
C12C13
C14C15
C16C17
C18C19
C20C21
C22C23
C24C25
C26C27
C28C29
C30
P1P2P3P4L1L2L3L4
IS-CCU/
IS-IPC
DC48V
AUDIO DOOR/SUB STATION
PA OUTPUT (600Ω)CONTACT OUTPUT (AC/DC24V  0.5A)
CAT5e/6
300m
(980)15m (50)
200m
(650)CAT5e/6
150m
(490)
*1
CD
1CX11CX2
PT
*2
10m
(33)
IP1IP2
CAT5e/6 (x2)
CAT5e/6 (x2)
φ0.8-1.2mm 
(20-16 AWG)2C P NP
2C
φ0.65-1.2mm
(22-16 AWG)
NP
2C
φ0.65-1.2mm
(22-16 AWG)
NP
2C
φ0.65-1.2mm
(22-16 AWG)
15m (50)
*1: This...

Page 16

16
IP control unit (
IS-IPC)
IPThis unit is needed to connect a local system to a standard (IP) system.
■ Part names
NOTE:
The illustration of the unit may differ from the actual one.
■ Specifi cations
IP control unit (IS-IPC)
Power source 48V DC (supplied from the power supply unit)
Current consumption Max. 105mA
Ambient temperature 0 - 40°C (+32°F - +104°F)
Talk channels
~Video 
channels, other channels2 talk & 2 constrained video channels,
1 chime, and 1 telephone (North America 
only)
Central...

Page 17

17
■ Connections
IP1 IP2 IP3LAN
IS-RCU
IS-CCU
DC48V
ETHERNET
CO
TELEPHONE
10m (33)
10m (33)15m (50)
2C
IP1IP2IP3
φ0.8-1.2mm 
(20-16 AWG)IP1 IP2 IP3
IS-RCU
IS-CCU
CAT5e/6 (x3)10BASE-T
100BASE-TX
100m (330)
CX1/IP1CX2/IP2
CAT5e/6 (x2)
P
*3
*1: When connecting a central control unit (IS-CCU) to this unit, connect it to the IP1, IP2 and IP3 ports.
*2: When connecting a room sub control unit (IS-RCU) to this unit, connect it to the IP1 and IP2 ports.
*3: Do not install two power supplies in parallel to a...

Page 18

18
Color monitor master station (IS-MV)
For the part names and their functions, see the OPERATION MANUAL.* 
■ Accessories
~Mounting bracket × 1
~Name card × 1
~Desktop stand × 1
~Screw (15mm (5/8), for wall-mounting) × 4
~Tie-wrap × 1
~Screw (25mm (1), for gang box) × 4
~Name plate × 1
~Screw (10mm (7/16), for desktop stand) × 4
~China RoHS paper × 1
■ Mounting
When mounting on a wall


Mounting bracket 
(attached to the unit with shipment)
Mounting bracket 
(attached to the unit with shipment)...

Page 19

19
When mounting on a desktop stand
30r
45r
60r
■ Connections
M
VVAA
VIDEO
OUTPUT
AUDIO
OUTPUT
M1M4
CAT5e/6
Coax2C
M1M8
CAT5e/6
P
NP
NTSC
NOTES:
Do not use the unoccupied terminals and ports for other purposes.
In order to prevent miswiring, label both ends of each cable with the unit and terminal names to which they are to be connected.
For connecting other manufacture’s products, refer to the instruction manuals for those products.
The illustration of the unit’s rear panel differs from the actual one....

Page 20

20
Vandal-resistant video door station (IS-DV, IS-DVF), 
Vandal-resistant audio door station (IS-SS)
■ Accessories
~Screw (for wall-mounting) × 4 (IS-DV only)
~Special screwdriver × 1
~Anchor × 4 (IS-DV only)
~Back box × 1 (IS-DVF and IS-SS only)
~Transparent name plate × 2 (IS-DV and IS-DVF only)
~China RoHS paper × 1
~Special screw × 4 (IS-DVF and IS-SS only)
■ Mounting locations (IS-DV and IS-DVF)
Do not install this unit in any of the following locations where lighting or the ambient...