Aiphone IS Series Installation Manual
Here you can view all the pages of manual Aiphone IS Series Installation Manual. The Aiphone manuals for Telephone are available online for free. You can easily download all the documents as PDF.
Page 1
Thank you for selecting Aiphone for your communication and security needs. Please read this manual carefully before installation, and keep it in a safe place for future reference. Also read the SETTING MANUAL and OPERATION MANUAL on the bundled CD-ROM. When the installation is completed, confi gure the system by following the SETTING MANUAL. Otherwise, the system will be non- functional. IMPORTANT Do not install the system until you have completely understood the system and this manual.• The system must...
Page 2
2 CONTENTS PRECAUTIONS ................................ 3 WARNING ....................................... 3 CAUTION ........................................ 3 GENERAL PRECAUTIONS ............ 3 Notes on using this system .......... 4 Notices ............................................ 4 SYSTEM CONFIGURATIONS .......... 4 Entire system ................................ 4 System confi guration examples .... 5 ■ Standard (IP) system ............................ 5 CONNECTIONS .................................
Page 3
3 PRECAUTIONS General Prohibitions Prohibition to Dismantle the Unit Prohibition on Subjecting the Unit to Water General Precautions WARNING Negligence could result in death or serious injury. 1. Do not dismantle or alter the unit. Fire or electric shock could result. 2. Keep the unit away from water or any other liquid. Fire or electric shock could result. 3. High voltage is present internally. Do not open the case. Electric shock could result. 4. The unit is not of explosion-proof. Do...
Page 4
4 SYSTEM CONFIGURATIONS The IS system is a commercial and security video intercom system especially designed for applications in facilities such as offi ce buildings, factories, schools, hospitals, and prisons. Installed separately from conventional general-purpose internal communications systems, the IS system can be used as a video door entry system, emergency announcement system, rescue assistance system, urgent call system, public announcement system, and access control system. The IS system can be...
Page 5
5 System confi guration examples ■ Standard (IP) system The following is an example of standard (IP) system for controlling security and communication for facilities. A site must be confi gured with an IP-based system. • A standard (IP) system can consist of local systems and IP units.• A local system (Hard wired network system) without connecting to an IP network can also be an independent system.• When using a local system as an independent system, it needs at least one central control unit (IS-CCU)....
Page 6
6 CONNECTIONS System connection diagram The following is an example of standard (IP) system connection diagram. Refer to page 9 to 26 for details about each unit connection. * IPIS-IPC*1 IS-CCU IS-RCUIS-SCU IS-RSIS-RS IS-RS IS-MV IS-DV/IS-DVF /IS-SS IS-DV/IS-DVF /IS-SS IS-MV PT PT IS-SS IS-PU-UL IS-PU-S IS-PU-UL IS-PU-S IS-PU-UL IS-PU-SIS-PU-UL IS-PU-S Local system (Max.8) (Max. 8) (Max. 4)(Max. 4) (Max. 2) (Max. 4) (Max. 1) (Max. 30) To Internet/WAN Monitor MonitorRecorderRecorder Broadband router...
Page 7
7 IP IP IS-IPC*1 IS-RCU IS-RS IS-IPMV IS-IPDV /IS-IPDVF IP PTIS-SS IP PS-2420/D/UL/S*2PS-2420/D/UL/S*2 IS-PU-UL IS-PU-S IS-PU-UL IS-PU-SPoEPoE AC transformer Maximum number of each unit connectable to a local system and a site of standard (IP) system Category Model name TypeMax. number Local system Standard (IP) system LocalControl unitIS-CCU Central control unit 1 8*4 IS-SCU Add-on control unit 2 16 IS-RCU Room sub control unit 4 32 Master station IS-MV Color monitor master station 20 160 Sub...
Page 8
8 Cables Cables and connectors are not included with the products. Refer to page 9 to 26 for details about each unit connection. Notes on cables Pair4 Pair3 12345678 12345678 Pair2 Pair1 T568A Pair4 Pair2Pair3 Pair1 T568B How to connect or disconnect stranded wires. 8mm(3/8") Notes on CAT5e/6 cables Do not bend the cables to an extent where the radius is • less than 25 mm (1”). Communication failure could result. Do not remove the CAT5e/6 cable jacket more than • necessary. Odd number cables, such...
Page 9
9 UNIT DETAILS Control unit common information The information on this page is common to Central control unit (IS-CCU), Add-on control unit (IS-SCU), Room sub control unit (IS-* RCU) and IP control unit (IS-IPC). ■ Accessories ~Mounting bracket × 2 ~Installation manual (a booklet)*1 × 1 ~Screw (for wall-mounting) × 4 ~CD-ROM (Installation manual, Setting manual and Operation manual)*2 × 1 ~Screw (for rack-mounting) × 4 ~China RoHS paper × 1 ~Screw (for fi xing mounting bracket) × 6 ■ Mounting...
Page 10
10 Central control unit ( IS-CCU) ■ Part names NOTE: The illustration of the unit may differ from the actual one. ■ Specifi cations Central control unit (IS-CCU) Power source 48V DC (supplied from the power supply unit) Current consumption Max. 800mA Ambient temperature 0 - 40°C (+32°F - +104°F) Talk channels ~Video channelsLocal system: 2 talk & 2 video channels, 1 chime Master station(s) Max. 4 Video door station(s) Max. 4 Audio door station(s) Room sub station(s) Add-on control unit Max. 2 Room sub...