Page 41

==========================================Chapter 6=========== 
① Real time data display mode 
 
Pressing [↑] and [↓] key under real time display mode (「D-No」display 0~5) will 
change「D-No」(data number) with following display appearing. 
 
Following data will be displayed on「DATA」display. 
D-NO DATA 
0 Display torque value 
1 Display torque voltage 
2 Display maximum torque (Maximum value hold) 
3 Display turning angles 
4 Electronic thermal value%(Over load detected when 100%) for adjustment 
5 Motor...

Page 42

======Chapter 6=============================================== 
② Tightening result display mode 
Pressing [↑] and [↓] key under tightening result display mode (「D-No」display 
_0~=6) will change「D-No」(data number) with following display appearing.  
Following data will be displayed on「DATA」display. (D-No. with asterisk mark is 
effective for single spindle specifications) 
 
 D-NO DATA 
 __0 Peak torque value 
 __1 Final angle value 
 __2 Snug torque detection 
 __3 Work Numbers 
* __4 1st area...

Page 43

==========================================Chapter 6=========== 
D-No. area display in tightening process for single spindle specifications 
 
  In.  Tightening is in process under initial speed. 
  Fr.  Tightening is in process under free run speed. 
  LS.  Tightening is in process under slow down speed. 
  Tq.  Tightening is in process under torque speed. 
 1E. 1st completed and waiting for 2nd step. 
  2d.  Tightening is in process under 2nd step. 
 2E. 2nd (cross) completed and waiting for 3rd step....

Page 44

======Chapter 6=============================================== 
③ Setting value display mode 
Pressing [↑] and [↓] key under tightening setting value display mode (2-digit 
D-No)display 00~74) will change「D-No」(data number) and you will be able to see 
individual setting value. 「PARM」parameter number can be changed from 1~64 
and the corresponding data will be displayed.  You can have all displays with 
setting value data and parameter numbers inclusive by operating [↑] or [↓] key.  
(Keep pressing [↑]...

Page 45

==========================================Chapter 6=========== 
Status display 
Displays this status display when UEC-F300 gives alarm or stop signal is OFF 
input.  Status display will be the following display (「D-NO」display is not 
available). 
 
 
(1) When stop signal OFF input. 
    Displays STOP on「DATA」display. 
 
 
 
 
 
 
 
(2) When ALARM occurs. 
 Displays Aln on「DATA」display. 
At the same time display of ALARM LED on「PARA」will light with alarm 
number display, and display of「D-NO」displays sub...

Page 46

======Chapter 6=============================================== 
6-3 BYPASS (non-operation) status 
Position of BYPASS switch will tell you non-operation switched on status.  Spindle 
unit will display on D-No display “U.01” together with spindle number but will not 
give「DATA」display under non-operation switched on status. 
 
6-3-1 Download mode and setting value select mode 
 (1) Down load mode 
Spindle unit becomes down load mode after switching on BYPASS.  Download 
mode is the status that you can...

Page 47

==========================================Chapter 6=========== 
6-3-2 Mode change 
Press [MODE] switch one time to change to setting value select mode and a cursor 
appearing with the first digit flushing. 
 
 
 
Press MODE switch to change to setting value 
select mode and a cursor appearing with the first 
digit flushing. 
 
Change parameter numbers +1, -1 by pressing  
↑ and ↓ key. 
Press SET switch to change to EDIT mode in 
order to amend setting value on display on DATA 
display. 
 
 
Do ups and...

Page 48

======Chapter 6=============================================== 
6-3-3 Key operation under non-operation status 
 
 
 
 
 
 
 
 
 
 
 
Setting value 
select mode 
[SET]key :Data setting or 
Press[MODE]key at bottom digit :Data not changed
[MODE]key 
[SET]key 
Data edit mode 
Download mode 
 
Key operation under setting value select mode 
 
 
Parameter number 
「PARM.ALN」 
Data number
「D-NO」① 
Data number 
「D-NO」② 
[MODE]key [MODE]key 
[MODE]key 
 
 
 
 
 
 
 
 
 
 
 
(1)Select of parameter number 
When...

Page 49

==========================================Chapter 6=========== 
6-3-4  (1) Parameter list (mutli-spindle specifications) 
【System parameter 】 
PARM  D-NO 
00-00   Torque unit        0    Nm (Others not available) 
00-01   (Spindle soft version)      0.17 
00-02   (Amplifier soft version)      4 
00-03   Function version        1.00 
00-04   External gear ratio      1.000 
00-20   Connected tool umber      5   UNR-F015-350NT 
      (Refer to next page tool list.) 
【Tightening parameter 】 
Parameter...

Page 50

======Chapter 6=============================================== 
PARM  D-NO 
   41   Cycle timer 
   43   Initial timer 
   45   Rotate speed increase time          0.5 seconds 
   46   Rotate speed decrease time          0.5 seconds 
   47   Reverse rotate speed increase time   0.5 seconds 
   48   Cut hold timer 
   49   Start delay timer             Pre-load 
   4A   1P timer                    1P 
   4B   Idle running measurement timer 
   50   Initial speed 
   51   Free run speed 
   52   Reduction...
Start reading Aimco Brakes Nutrunner FSeries Spindle Unit Manual