Page 51
==========================================Chapter 6=========== 6-3-4 (2) Tool list Tool setting No. Tool type Max. torque Nm Max. speed CAL Spindle unit 1 UNR-F015-45NT 4.5 3200 34.3 UEC-F024 2 UNR-F015-65NT 6.5 2222 34.3 UEC-F024 3 UNR-F015-200NT 20.0 730 34.3 UEC-F024 4 UNR-F015-280NT 28.0 507 34.3 UEC-F024 5 UNR-F015-350NT 35.0 412 34.3 UEC-F024 11 UNR-F015-500NT 50.0 221 78.6 UEC-F024 12 UNR-F015-800NT 80.0 180 78.6 UEC-F024 13 UNR-F015-25NTC 28.0 469 53.4 UEC-F024 14 UNR-F015-55NTC...
Page 52
======Chapter 6=============================================== Calibration value setting Input tools’ torque in spindle unit as the calibration value usually. Change calibration number, however, to compensate the difference UEC-F300 detect display and inspection result by test equipment which can be caused by physical circumstances such as special socket or additional offset gears giving tools’ front part burdens, or fasteners’ nature of joint. Inspection result from test equipment x CAL...
Page 53
==========================================Chapter 7=========== Chapter 7 Trouble shooting 7-1 Alarm display We will explain trouble conditions and how to pursue the causes when ALARM LED on spindle unit front panel is lighting while in operation of UEC-F300. Display of alarm sub code Note: Optional display panel is required. Keep pressing [MODE] switch until 「DATA」 “ALn” is displayed. Make it a few times. Panel display will become the following status with alarm sub code display...
Page 54
======Chapter 7=============================================== 7-2 Alarm numbers and the contents Alar m Sub Code Place Error contents and remarks Disposi- tion 0 Zero point master error. Tool and torque sensor connection original point voltage error. 01.09.11. 31.33.34. 36 1 CAL error. Torque sensor CAL voltage error. 01.09.11.31. 33.34.36 4 Switched on under Zero point master error. Unable to start tightening due to Zero point master error. Unable to start tightening until fixed....
Page 55
==========================================Chapter 7=========== Trouble shooting No. Trouble shooting 01 Check pre-amplifier cable. 02 Check resolver cable. 03 Check motor power cable. 04 Replace pre-amplifier cable with spare. 05 Replace resolver cable with spare. 06 Check motor power cable with spare. 07 Replace spindle unit power cord. 08 Check rotating resistance given by nutrunner front tool (spindle adapter or etc). 09 Check original point calibration value. 10 Check fasteners (to be...
Page 56
======Chapter 8=============================================== Chapter 8 Option UEC-F300 unit provide the following options. 1. UEC-MKB Display unit to be installed to UEC-F024 and UEC-F040. 2. UEC-MKB II Display unit to be installed to UEC-F120. Installation and removal Open or tighten 2 screws at the bottom part highlighted by black circle (●) for installation and removal. Do not open screws available at top part this display unit. UEC-MKB SET MODE DATA PARM RESET...