Page 51

==========================================Chapter 6=========== 
6-3-4 (2) Tool list 
Tool 
setting 
No. Tool type Max. torque 
Nm 
Max. speed CAL Spindle unit 
1 UNR-F015-45NT 4.5 3200 34.3 UEC-F024 
2 UNR-F015-65NT 6.5 2222 34.3 UEC-F024 
3 UNR-F015-200NT 20.0 730 34.3 UEC-F024 
4 UNR-F015-280NT 28.0 507 34.3 UEC-F024 
5 UNR-F015-350NT 35.0 412 34.3 UEC-F024 
11 UNR-F015-500NT 50.0 221 78.6 UEC-F024 
12 UNR-F015-800NT 80.0 180 78.6 UEC-F024 
13 UNR-F015-25NTC 28.0 469 53.4 UEC-F024 
14 UNR-F015-55NTC...

Page 52

======Chapter 6=============================================== 
Calibration value setting 
 
Input tools’ torque in spindle unit as the calibration value usually.  Change calibration 
number, however, to compensate the difference UEC-F300 detect display and 
inspection result by test equipment which can be caused by  physical circumstances 
such as special socket or additional offset gears giving tools’ front part burdens, or 
fasteners’ nature of joint.   
 
Inspection result from test equipment 
x CAL...

Page 53

==========================================Chapter 7=========== 
Chapter 7 Trouble shooting 
7-1 Alarm display 
We will explain trouble conditions and how to pursue the causes when ALARM 
LED on spindle unit front panel is lighting while in operation of UEC-F300. 
 
Display of alarm sub code       Note: Optional display panel is required. 
 
Keep pressing [MODE] switch until 「DATA」 “ALn” is displayed.  Make it a few 
times.  Panel display will become the following status with alarm sub code display...

Page 54

======Chapter 7=============================================== 
7-2  Alarm numbers and the contents 
Alar
m Sub 
Code 
Place Error contents and remarks Disposi- tion 
0 Zero point master error.  Tool and torque sensor 
connection original point voltage error. 01.09.11. 
31.33.34. 
36 
1 CAL error.  Torque sensor  CAL voltage error. 01.09.11.31.
33.34.36 
4 Switched on under Zero point master error.    Unable 
to start tightening due to Zero point master error. 
Unable to start tightening until fixed....

Page 55

==========================================Chapter 7=========== 
Trouble shooting 
No. Trouble shooting 
01 Check pre-amplifier cable. 
02 Check resolver cable. 
03 Check motor power cable. 
04 Replace pre-amplifier cable with spare. 
05 Replace resolver cable with spare. 
06 Check motor power cable with spare. 
07 Replace spindle unit power cord. 
08 Check rotating resistance given by nutrunner front tool (spindle adapter    or etc). 
09 Check original point calibration value. 
10 Check fasteners (to be...

Page 56

======Chapter 8=============================================== 
Chapter 8 Option 
 
UEC-F300 unit provide the following options. 
 
      1. UEC-MKB 
  Display unit to be installed to UEC-F024 and UEC-F040. 
      2. UEC-MKB II 
   Display unit to be installed to UEC-F120. 
Installation and removal 
Open or tighten 2 screws at the bottom part highlighted by black circle (●) for 
installation and removal.  Do not open screws available at top part this display unit. 
 
UEC-MKB
SET
MODE 
DATA 
PARM 
RESET...