Page 21

==========================================Chapter 4=========== 
 
 
Unit heat value 
 
Spindle unit type Average heat value Stand by heat value 
UEC-F024        About 26W       About 18W 
UEC-F040        About 39W       About 18W 
UEC-F120        About 74W       About 18W 
UEC-F300M 
(I/O) 
                    About 5.5W 
UEC-F300M 
(CC-LINK) 
                    About 5.5W 
UEC-F300M 
(D-NET) 
                    About 5.5W...

Page 22

======Chapter 4=============================================== 
4-2 Power plug connections
 
Use right bottom power socket to supply spindle unit with electricity. 
Use accessory power cord which comes with spindle unit. 
Protect spindle unit by circuit protector when power supply. 
 
 
 
 
 
      Connections 
 
      4: U 
      3: V 3-phase alternate current 
      2: W  AC-200~220V 
      1: FG 
T/D
MOTOR
AC200-220V
4:U 
3:V CN 
  I/O 
AC200V 
2:W 
1:FG
 
UEC- 
F024 
 
 
URYU 
 
 
 
 
Suitable plugs...

Page 23

==========================================Chapter 4=========== 
4-3 External control signal wiring
4-3-1 AXIX I/O signals  When main operation is under setting. 
NO Signals IN/OUT Contents 
1   
2   
3   
4   
Do not use. 
5 BYPASS IN    NO Select non-operation 
6  
7  
 Do not use. 
8   Do not use. 
9   
10   
Do not use. 
11 SENSOR IN    NO Proximity sensor connection for pin hole control
12   Do not use. 
13 IN COMMON  Common for input signals, connect +12~24V 
14   Do not use. 
15 BANK SELECT 1 IN...

Page 24

======Chapter 4=============================================== 
4-3-2 AXIS I/O OUT DATA signals
AXIS I/O BANK SELECT table 
Pin No. Signals IN/OUT Contents 
16 
15 
BANK SELECT 0 
BANK SELECT 1 
IN   NO 
IN   NO 
Change OUT DATA 0-11 contents. 
 
OUT DATA  BANK 
SEL.0 
Pin16 
BANK 
SEL.1 
Pin15 Pin 
No. 
Signal 
Contents 
31 OUT DATA0 NOK Result was NOK. 
30 OUT DATA1 OK Result was OK. 
29 OUT DATA2 READY Unit is ready. 
28 OUT DATA3 HIGH NOK Judgment was high. 
27 OUT DATA4 LOW NOK Judgment was low....

Page 25

==========================================Chapter 4=========== 
Upper limit: Value greater than standard upper limit  NOK 
  Value less than standard upper limit  OK 
Low limit Value greater than standard low limit  OK 
  Value less than standard low limit  NOK 
 
NOK< Standard low limit≦OK

Page 26

======Chapter 4=============================================== 
4-3-4  Input output signals 
(1) Input signals 
Providing input terminals with LOW (0V)  will change spindle unit to “ON” status. 
 
1. BYPASS:  Non-operation signal 
While this signal is being switched “ON”, spindle unit becomes 
non-operation status and does not  start tightening with providing 
BYPASS signal. 
Tightening operation will be suspended  when spindle unit  becomes 
non-operation status whil e in tightening operation. 
  2....

Page 27

==========================================Chapter 4=========== 
Output bank 1 
(DATA 0) NOK: Tightening NOK signal (when completed with NOK) 
This is output when tightening result of spindle unit completed out of preset range. 
 
(DATA 1) OK: Tightening OK signal (when completed with OK) 
This is output when tightening result of  spindle unit completed normally within 
preset range. 
 
(DATA 2) READY: Input permission signal 
This is output when spindle unit is prepar ed to give operation (tightening,...

Page 28

======Chapter 4=============================================== 
Output bank 2 (Not applicable when  multiple spindles are in use) 
(DATA0) Time 1 NOK: Time over of 1st area (not used yet) 
This is output when tightening of spindle unit fails to reach 1st torque or 1st angle 
before time of 1st timer is over.    This is also  output when tightening of spindle unit 
reaches 1st torque or 1st angle within preset minimu m tightening time.    Use this 
function for “No bolt” or “No work” detection....

Page 29

==========================================Chapter 4=========== 
Output bank 4 
(DATA0~3) ALARM  SUB  0~3 
Output detailed code when ALARM is provided.    4-bit will be provided. 
(DATA4~7) ALARM CODE 0~3 
Output detailed code when ALARM is provided.    4-bit will be provided. 
 
Contents of errors shall be classified in  the following table.This is from 8-bit 
combination of ALARM code and ALARM sub. 
 
ALARM NUMBERS ALARM SUB NUMBERS ALARM CODE0 ALARM CODE1 ALARM CODE2 ALARM CODE3 ALARM CODE0 ALARM...

Page 30

======Chapter 4=============================================== 
4-4 Spindle unit number setting 
Set spindle unit number from 1 when you use UEC-F300 system for multiple 
nutrunners.  Make this setting from DIP (SW1) switch available in the front panel 
of spindle unit. 
 
Note: Keep DIP switch 1~3 OFF position for ordinary use. 
 
DIP switch numbers 
1  OFF: Multiple spindles specifications 
ON: Single spindle specifications 
2  OFF:Level start method 
ON:One pulse start method (effective for 
single...