==========================================Chapter 4=========== Unit heat value Spindle unit type Average heat value Stand by heat value UEC-F024 About 26W About 18W UEC-F040 About 39W About 18W UEC-F120 About 74W About 18W UEC-F300M (I/O) About 5.5W UEC-F300M (CC-LINK) About 5.5W UEC-F300M (D-NET) About 5.5W...
Page 22
======Chapter 4=============================================== 4-2 Power plug connections Use right bottom power socket to supply spindle unit with electricity. Use accessory power cord which comes with spindle unit. Protect spindle unit by circuit protector when power supply. Connections 4: U 3: V 3-phase alternate current 2: W AC-200~220V 1: FG T/D MOTOR AC200-220V 4:U 3:V CN I/O AC200V 2:W 1:FG UEC- F024 URYU Suitable plugs...
Page 23
==========================================Chapter 4=========== 4-3 External control signal wiring 4-3-1 AXIX I/O signals When main operation is under setting. NO Signals IN/OUT Contents 1 2 3 4 Do not use. 5 BYPASS IN NO Select non-operation 6 7 Do not use. 8 Do not use. 9 10 Do not use. 11 SENSOR IN NO Proximity sensor connection for pin hole control 12 Do not use. 13 IN COMMON Common for input signals, connect +12~24V 14 Do not use. 15 BANK SELECT 1 IN...
Page 24
======Chapter 4=============================================== 4-3-2 AXIS I/O OUT DATA signals AXIS I/O BANK SELECT table Pin No. Signals IN/OUT Contents 16 15 BANK SELECT 0 BANK SELECT 1 IN NO IN NO Change OUT DATA 0-11 contents. OUT DATA BANK SEL.0 Pin16 BANK SEL.1 Pin15 Pin No. Signal Contents 31 OUT DATA0 NOK Result was NOK. 30 OUT DATA1 OK Result was OK. 29 OUT DATA2 READY Unit is ready. 28 OUT DATA3 HIGH NOK Judgment was high. 27 OUT DATA4 LOW NOK Judgment was low....
Page 25
==========================================Chapter 4=========== Upper limit: Value greater than standard upper limit NOK Value less than standard upper limit OK Low limit Value greater than standard low limit OK Value less than standard low limit NOK NOK< Standard low limit≦OK
Page 26
======Chapter 4=============================================== 4-3-4 Input output signals (1) Input signals Providing input terminals with LOW (0V) will change spindle unit to “ON” status. 1. BYPASS: Non-operation signal While this signal is being switched “ON”, spindle unit becomes non-operation status and does not start tightening with providing BYPASS signal. Tightening operation will be suspended when spindle unit becomes non-operation status whil e in tightening operation. 2....
Page 27
==========================================Chapter 4=========== Output bank 1 (DATA 0) NOK: Tightening NOK signal (when completed with NOK) This is output when tightening result of spindle unit completed out of preset range. (DATA 1) OK: Tightening OK signal (when completed with OK) This is output when tightening result of spindle unit completed normally within preset range. (DATA 2) READY: Input permission signal This is output when spindle unit is prepar ed to give operation (tightening,...
Page 28
======Chapter 4=============================================== Output bank 2 (Not applicable when multiple spindles are in use) (DATA0) Time 1 NOK: Time over of 1st area (not used yet) This is output when tightening of spindle unit fails to reach 1st torque or 1st angle before time of 1st timer is over. This is also output when tightening of spindle unit reaches 1st torque or 1st angle within preset minimu m tightening time. Use this function for “No bolt” or “No work” detection....
Page 29
==========================================Chapter 4=========== Output bank 4 (DATA0~3) ALARM SUB 0~3 Output detailed code when ALARM is provided. 4-bit will be provided. (DATA4~7) ALARM CODE 0~3 Output detailed code when ALARM is provided. 4-bit will be provided. Contents of errors shall be classified in the following table.This is from 8-bit combination of ALARM code and ALARM sub. ALARM NUMBERS ALARM SUB NUMBERS ALARM CODE0 ALARM CODE1 ALARM CODE2 ALARM CODE3 ALARM CODE0 ALARM...
Page 30
======Chapter 4=============================================== 4-4 Spindle unit number setting Set spindle unit number from 1 when you use UEC-F300 system for multiple nutrunners. Make this setting from DIP (SW1) switch available in the front panel of spindle unit. Note: Keep DIP switch 1~3 OFF position for ordinary use. DIP switch numbers 1 OFF: Multiple spindles specifications ON: Single spindle specifications 2 OFF:Level start method ON:One pulse start method (effective for single...