==========================================Chapter 4=========== Unit heat value Spindle unit type Average heat value Stand by heat value UEC-F024 About 26W About 18W UEC-F040 About 39W About 18W UEC-F120 About 74W About 18W UEC-F300M (I/O) About 5.5W UEC-F300M (CC-LINK) About 5.5W UEC-F300M (D-NET) About 5.5W ============================================================ 19
======Chapter 4=============================================== 4-2 Power plug connections Use right bottom power socket to supply spindle unit with electricity. Use accessory power cord which comes with spindle unit. Protect spindle unit by circuit protector when power supply. Connections 4: U 3: V 3-phase alternate current 2: W AC-200~220V 1: FG T/D MOTOR AC200-220V 4:U 3:V CN I/O AC200V 2:W 1:FG UEC- F024 URYU Suitable plugs Manufacturer : AMP Type : D3200S Rise Housing Number : 1-178128-4 (keying X) Type : Rise contact (crimp type) Number : 1-175218-3 Recommended circuit protector Spindle unit Circuit protector type (manufacturer : Izumi electric UEC-F024 NRC210L-5A-AA UEC-F040 NRC210L-7A-AA UEC-F120 NRC210L-15A-AA Note: Select delay action type. Recommended trans capacity Spindle unit Trans capacity UEC-F024 0.2KVA~0.3KVA X Spindle numbers UEC-F040 0.6KVA~1.0KVA X Spindle numbers UEC-F120 3.0KVA~6.0KVA X Spindle numbers ============================================================ 20
==========================================Chapter 4=========== 4-3 External control signal wiring 4-3-1 AXIX I/O signals When main operation is under setting. NO Signals IN/OUT Contents 1 2 3 4 Do not use. 5 BYPASS IN NO Select non-operation 6 7 Do not use. 8 Do not use. 9 10 Do not use. 11 SENSOR IN NO Proximity sensor connection for pin hole control 12 Do not use. 13 IN COMMON Common for input signals, connect +12~24V 14 Do not use. 15 BANK SELECT 1 IN NO 16 BANK SELECT 0 IN NO Change data OUT DATA 0-11 contents. 17 18 19 Do not use. 20 CCW IN NO Change rotating direction. Use for left thread or tools’ front has an extra gear. 21 Do not use. 22 OUT DATA 11 OUT NO Output system status as per BANK SELECT signal. 23 OUT COMMON Common for output signals, connect 0V. 24 OUT DATA 7 OUT NO 25 DATA OUT 6 OUT NO 26 DATA OUT 5 OUT NO 27 DATA OUT 4 OUT NO 28 DATA OUT 3 OUT NO 29 DATA OUT 2 OUT NO 30 DATA OUT 1 OUT NO 31 DATA OUT 0 OUT NO 32 DATA OUT 10 OUT NO 33 DATA OUT 9 OUT NO 34 DATA OUT 8 OUT NO Output system status as per BANK SELECT signal. IN: Input signal OUT: Output signal NC: Normal close NO: Normal open Suitable plugs Manufacturer: Honda communication industry (HONDA) Name :Multipolar connector small Vertical case Type :MR-34M, MR-34L =========================================================== 21
======Chapter 4=============================================== 4-3-2 AXIS I/O OUT DATA signals AXIS I/O BANK SELECT table Pin No. Signals IN/OUT Contents 16 15 BANK SELECT 0 BANK SELECT 1 IN NO IN NO Change OUT DATA 0-11 contents. OUT DATA BANK SEL.0 Pin16 BANK SEL.1 Pin15 Pin No. Signal Contents 31 OUT DATA0 NOK Result was NOK. 30 OUT DATA1 OK Result was OK. 29 OUT DATA2 READY Unit is ready. 28 OUT DATA3 HIGH NOK Judgment was high. 27 OUT DATA4 LOW NOK Judgment was low. 26 OUT DATA5 TQ.HIGH.NOK Torque exceeded upper limit. 25 OUT DATA6 TQ.LOW.NOK Torque not exceeded low limit. 24 OUT DATA7 BYPASS Non-operation status 34 OUT DATA8 NOK CODE 0 33 OUT DATA 9 NOK CODE 1 32 OUT DATA10 NOK CODE 2 B A N K 1 OFF OFF 22 OUT DATA11 NOK CODE 3 Output NOK contents by 4 codes. 31 OUT DATA0 TIME 1 NOK 1st tightening not completed in preset time. 30 OUT DATA1 TIME 2 NOK Final tightening not completed in preset time. 29 OUT DATA2 PRAM.SELECT0 28 OUT DATA3 PRAM.SELECT1 27 OUT DATA4 PRAM.SELECT2 26 OUT DATA5 PRAM.SELECT3 25 OUT DATA6 PRAM.SELECT4 24 OUT DATA7 PRAM.SELECT5 Output designated parameter numbers. 34 OUT DATA8 Not used 33 OUT DATA 9 Not used 32 OUT DATA10 Signal 1 Signal between main unit. B A N K 2 ON OFF 22 OUT DATA11 Signal 2 Signal between main unit. 31 OUT DATA0 NOK Result was NOK. 30 OUT DATA1 OK Result was OK. 29 OUT DATA2 READY Unit is ready. 28 OUT DATA3 ALARM System is giving errors. 27 OUT DATA4 BUSY Tightening is in operation. 26 OUT DATA5 ANG.HIGH.NOK Turning angles exceeded upper limit. 25 OUT DATA6 ANG.LOW.NOK Turning angles not exceeded low limit. 24 OUT DATA7 BYPASS Non-operation status 34 OUT DATA8 Not used 33 OUT DATA 9 Not used 32 OUT DATA10 Not used B A N K 3 OFF ON 22 OUT DATA11 Not used 31 OUT DATA0 ALARM SUB 0 30 OUT DATA1 ALARM SUB 1 29 OUT DATA2 ALARM SUB 2 28 OUT DATA3 ALARM SUB 3 Alarm sub numbers: Output detailed code by 4 bit when alarm is provided. 27 OUT DATA4 ALARM CODE0 26 OUT DATA5 ALARM CODE1 25 OUT DATA6 ALARM CODE2 24 OUT DATA7 ALARM CODE3 Alarm sub numbers: Output code by 4 bit when alarm is provided. 34 OUT DATA8 Not used 33 OUT DATA 9 Not used 32 OUT DATA10 Not used B A N K 4 ON ON 22 OUT DATA11 Not used *Not in action When nutrunner is in in use. ============================================================ 22
==========================================Chapter 4=========== Upper limit: Value greater than standard upper limit NOK Value less than standard upper limit OK Low limit Value greater than standard low limit OK Value less than standard low limit NOK NOK< Standard low limit≦OK
======Chapter 4=============================================== 4-3-4 Input output signals (1) Input signals Providing input terminals with LOW (0V) will change spindle unit to “ON” status. 1. BYPASS: Non-operation signal While this signal is being switched “ON”, spindle unit becomes non-operation status and does not start tightening with providing BYPASS signal. Tightening operation will be suspended when spindle unit becomes non-operation status whil e in tightening operation. 2. BANK SELECT 0, 1: Output signal bank select signal Option of bank numbers 1~4 will change contents of 12 output signals. Combination of BANK SELECT 0 and BANK SELECT 1 signals will make following output signal change possible. BANK SELECT 1 BANK SELECT 0 OUTPUT BANK OFF (OPEN) OFF (OPEN) 1 OFF (OPEN) ON 2 ON OFF (OPEN) 3 ON ON 4 (2) Output signals Electric pressure of output terminals get s the same level as output common (0V) when output signals are switched “ON”. Output signals (OUT0~OUT11) will have the following meanings (output banks) due to BANK SELECT signals combination. ON: Connected with 0V. OFF: Input common (HIGH) level or open. BANK1 BANK2 BANK3 BANK SEL.0 (Pin No.16) OFF ON OFF ON Pin No BANK SEL.1 (Pin NO.15) OFF OFF ON ON 31 OUT DATA 0 NOK TIME 1 NOK NOK ALARM SUB 0 30 OUT DATA 1 OK TIME 2 NOK OK ALARM SUB 1 29 OUT DATA 2 READY PRAM.SELECT0 READY ALARM SUB 2 28 OUT DATA 3 HIGH NOK PRAM.SELECT1 ALARM ALARM SUB 3 27 OUT DATA 4 LOW NOK PRAM.SELECT2 BUSY ALARM CODE 0 26 OUT DATA 5 TQ.HIGH NOK PRAM.SELEC T3 ANG.HIGH NOK ALARM CODE 1 25 OUT DATA 6 TQ.LOW NOK PRAM.SELECT4 ANG.LOW NOK ALARM CODE 2 24 OUT DATA 7 BYPASS PRAM.SELECT5 BYPASS ALARM CODE 3 34 OUT DATA 8 NOK CODE0 Not used Not used Not used 33 OUT DATA 9 NOK CODE1 Not used Not used Not used 32 OUT DATA 10 NOK CODE2 SIGNAL 1 Not used Not used 22 OUT DATA 11 NOK CODE3 SIGNAL 2 Not used Not used ※ Bank 2 is not in use when multiple spindles are in operation. ================================ ============================ 24
==========================================Chapter 4=========== Output bank 1 (DATA 0) NOK: Tightening NOK signal (when completed with NOK) This is output when tightening result of spindle unit completed out of preset range. (DATA 1) OK: Tightening OK signal (when completed with OK) This is output when tightening result of spindle unit completed normally within preset range. (DATA 2) READY: Input permission signal This is output when spindle unit is prepar ed to give operation (tightening, reverse or etc) as per input signals provided by external equipment such as sequencer. READY signal will be switched OFF under the following conditions. ○ Under initial processing for a few seconds when switched on. ○ Error signal output ○ Non-operation status (under setting, download or etc.) ○ When not in use ○ Under reset processing ○ Others when spindle unit is unable to meet external input (DATA 3) HIGH NOK: Upper limit NOK This is output when tightening comple ted with torque or angle exceeded upper limit, or initial NOK/ cycle NOK detected. (DATA4) LOW NOK: Low limit NOK This is output when tightening completed with torque or angle under low limit, or initial NOK/cycle NOK detected. (DATA5) TQ HIGH NOK: Torque upper limit NOK This is output when tightening complet ed with peak torque or final torque exceeded upper limit. (DATA6) TQ LOW NOK: Torque low limit NOK This is output when tightening completed with peak torque or final torque under low limit. (DATA7) BYPASS: non-operation status This is output when spindle unit is non-operation status. (DATA8-11) NOK CODE 0~3: NOK cont ents will be output via 4 points code. NOK CODE0 NOK CODE1 NOK CODE2 NOK CODE3 Pin 34 Pin 33 Pin 32 Pin 22 Contents ON OFF OFF OFF Alarm (refer to bank4 for the details. OFF ON OFF OFF Initial timer NOK ON ON OFF OFF Cycle timer NOK OFF OFF ON OFF Snug torque NOK ON OFF ON OFF Fit-in upper torque NOK OFF ON ON OFF Fit-in incline NOK ON ON ON OFF Plastic area angle incline NOK OFF OFF OFF ON Concurrent turning NOK ON OFF OFF ON Angle upper limit NOK OFF ON OFF ON Angle low limit NOK ================================ ============================ 25
======Chapter 4=============================================== Output bank 2 (Not applicable when multiple spindles are in use) (DATA0) Time 1 NOK: Time over of 1st area (not used yet) This is output when tightening of spindle unit fails to reach 1st torque or 1st angle before time of 1st timer is over. This is also output when tightening of spindle unit reaches 1st torque or 1st angle within preset minimu m tightening time. Use this function for “No bolt” or “No work” detection. (DATA1) Time 2 NOK: Time over of final tightening area (not used yet) This is output when spindle unit running time from 1st torque or 1st angle got longer than final time before tightening torque reac hes cut torque or cut angle. This is also output when spindle unit running time to reach cut torque or cut angle was shorter than preset minimum tightening time. (DATA2-7) PRAM.SELECT 0-5: Outputs designated parameter numbers. (DATA10-11) SIGNAL 1-2: Signals amongst spindle units Output bank 3 (DATA0) NOK: Tightening NOK signal (NOK end) This is output when spindle unit tighteni ng completion ended with result out of preset range. (DATA1) OK: Tightening OK signal (Normal completion) This is output when spindle unit tighteni ng ended normally within preset range. (DATA2) READY: Input permission signal This is output when spindle unit is prepar ed to give operation (tightening, reverse or etc) as per input signals provided by external equipment such as sequencer. READY signal will be switched OFF under the following conditions. ○ Under initial processing for a few seconds when switched on. ○ Error signal output ○ Non-operation status (under setting, download or etc.) ○ When not in use ○ When reset processing ○ Others when spindle unit is unable to meet external input (DATA3) ALARM: System error signal (Abnormal completion) This is output when spindle unit system che ck detects error, or spindle unit detects error during tightening operation. (DATA4) BUSY: In operation signal This is out put while tightening is in process. (DATA5) ANG.HIGH NOK: Angle upper limit NOK This is output when tightening complet ed with tightening angles exceeded upper limit. (DATA6) ANG/LOW NK: Angle low limit NOK This is output when tightening completed with tightening angles not exceeded low limit. (DATA7) BYPASS: non-operation status This is output when spindle unit is non-operation status. ================================ ============================ 26
==========================================Chapter 4=========== Output bank 4 (DATA0~3) ALARM SUB 0~3 Output detailed code when ALARM is provided. 4-bit will be provided. (DATA4~7) ALARM CODE 0~3 Output detailed code when ALARM is provided. 4-bit will be provided. Contents of errors shall be classified in the following table.This is from 8-bit combination of ALARM code and ALARM sub. ALARM NUMBERS ALARM SUB NUMBERS ALARM CODE0 ALARM CODE1 ALARM CODE2 ALARM CODE3 ALARM CODE0 ALARM CODE1 ALARM CODE2 ALARM CODE3 Pin27 Pin26 Pin25 Pin24 Pin31 Pin30 Pin29 Pin28 CONTENTS ON OFF OFF OFF OFF OFF OFF OFF (A1_0)ZERO POINT MASTER ERROR ON OFF OFF OFF ON OFF OFF OFF (A1_1)CAL ERROR ON OFF OFF OFF OFF OFF ON OFF (A1_4)SWITCH ON UNDER ZERO POINT MASTER ERROR ON OFF OFF OFF ON OFF ON OFF (A1_5)SWITCH ON UNDER CAL ERROR ON OFF OFF OFF OFF ON OFF ON (A1_6)ZERO POINT ERROR OFF ON OFF OFF ON OFF OFF OFF (A2_1) TORQUE OVER UNDER TORQUE CUT ON ON OFF OFF ON OFF OFF OFF (A3_1)TOOL TYPE ERROR ON ON OFF OFF OFF ON OFF OFF (A3_2)START WITH NO TOOL CONNECTED ON ON OFF OFF ON ON OFF OFF (A3_3)TOOL NOT CONNECTED OFF OFF ON OFF OFF OFF OFF OFF (A4_0)F-ROM WRITING ERROR OFF OFF ON OFF ON OFF OFF OFF (A4_1)F-ROM UPLOAD ERROR OFF OFF ON OFF OFF ON OFF OFF (A4_2)F-ROM AMPLIFIER SIDE ERROR OFF ON ON OFF OFF OFF OFF OFF (A6_0)NON-SETTING OF SERVO TYPE OFF OFF OFF ON ON OFF OFF OFF (A8_1)SPINDLE UNIT OVER –HEATING ERROR OFF OFF OFF ON OFF OFF ON OFF (A8_4)OVER CURRENT OFF OFF OFF ON ON OFF ON OFF (A8_5)OVER VOLTAGE,INTERNAL POWER PRESSURE ERROR OFF OFF OFF ON OFF ON ON OFF (A8_6)POWER VOLTAGE PRESSURE ERROR OFF OFF OFF ON ON OFF OFF ON (A8_9)OVER SPEED OFF OFF OFF ON OFF ON OFF ON (A8_10)OVER LOAD OFF OFF OFF ON ON ON OFF ON (A8_11)RESOLVER ERROR ON OFF OFF ON ON OFF OFF OFF (A9_1)SETTING ERROR ON OFF OFF ON OFF ON OFF OFF (A9_2)SYSTEM ERROR 1 ON OFF OFF ON ON OFF ON OFF (A9_5)SYSTEM ERROR 4 ON OFF OFF ON OFF ON ON OFF (A9_6)SYSTEM ERROR 5 ON OFF OFF ON ON ON ON OFF (A9_7)TORQUE LIMIT OVER ================================ ============================ 27
======Chapter 4=============================================== 4-4 Spindle unit number setting Set spindle unit number from 1 when you use UEC-F300 system for multiple nutrunners. Make this setting from DIP (SW1) switch available in the front panel of spindle unit. Note: Keep DIP switch 1~3 OFF position for ordinary use. DIP switch numbers 1 OFF: Multiple spindles specifications ON: Single spindle specifications 2 OFF:Level start method ON:One pulse start method (effective for single specifications) 3 OFF:Smooth speed reduction to torque speed ON:Quick speed reduction to torque speed Remove optional display unit when your spindle unit comes with optional display unit. Open 2 screws available in the bottom of display unit. Refer to chapter 8. CON1 OFF ON SW1 12POWER 345SP RUN 678M/D ALM BYPASS ALARM OK RUN NOK Spindle numbers setting table DIP SWITCH NUMBERS SPNDLE NUMBE RS 4 5 6 7 8 1 OFF OFF OFF OFF ON 2 OFF OFF OFF ON OFF 3 OFF OFF OFF ON ON 4 OFF OFF ON OFF OFF 5 OFF OFF ON OFF ON 6 OFF OFF ON ON OFF 7 OFF OFF ON ON ON 8 OFF ON OFF OFF OFF 9 OFF ON OFF OFF ON 10 OFF ON OFF ON OFF 11 OFF ON OFF ON ON 12 OFF ON ON OFF OFF 14 OFF ON ON ON OFF 15 OFF ON ON ON ON 16 ON OFF OFF OFF OFF DIP SWITCH NUMBERS SPNDLE NUMBE RS 4 5 6 7 8 17 ON OFF OFF OFF ON 18 ON OFF OFF ON OFF 19 ON OFF OFF ON ON 20 ON OFF ON OFF OFF 21 ON OFF ON OFF ON 22 ON OFF ON ON OFF 23 ON OFF ON ON ON 24 ON ON OFF OFF OFF 25 ON ON OFF OFF ON 26 ON ON OFF ON OFF 27 ON ON OFF ON ON 28 ON ON ON OFF OFF 29 ON ON ON OFF ON 30 ON ON ON ON OFF 31 ON ON ON ON ON Note: Spindle number setting cannot be duplicated. Make spindle number setting from 1 in order of number. ============================================================ 28