    2-2-2 Spindle unit
     
     CPU    32bit RISC 
      Data communication    RS485 (half duplex operation) 2 port 
     
    2-3 Functions
    2-3-1 Functions 
     
    (1) Tightening functions 
    F-type nutrunner system will give you the following 9 options. 
    1. Torque control 
    2. Angle control 
    3.  Plastic area angle control 
    4. Spline fit-in control 
    5.  Pin hole control 
    6. Pre-load controls 
    7. Idle running control 
    8.  Spline angle control 
    9. Yield control 
    (2) Non-operation (BYPASS) function 
    Spindle unit outputs BYPASS signal indicating non-operation status when you 
    input BYPASS signal or select BYPASS of front panel RUN/BYPASS.    START 
    signal does not switch on spindle uni t under this status and SYNC signal 
    becomes high impedance in order not to give synchronized tightening 
    affections. 
    Spindle unit stops tightening when the status  turns into non-operation status.     
    While in non-operation status, spindle unit will tell you non-operation by LED 
    [BYPASS] lamp in the front panel flushing. 
     
    (3)  Signal output functions wh en NOK or Alarm takes place 
    When tightening NOK or alarm takes the place, spindle unit stops tool running 
    with corresponding error signal number output and contents of NOK and alarm 
    number display on the front panel. 
     
     
     
     
     
     
     
     
     
     
    ================================ =========================== 
         9  
    						
    							
    ======Chapter 3=============================================== 
    3-1 UEC-F panel (spindle unit) 
    3-1-1 UED front panel switch and connector
     
     
     
     
     
        Status change switch 
          RUN/BYPASS change switch 
            RUN : Operation possible status 
    BYPASS: Non-operation status 
        External communication device 
          RS485 connector 
          RS485 connector 
        Connector 
          Resolver connector 
            Tool’s resolver connection 
          MON. connector (monitor output) 
    Analog electric pressure of torque and angle pulse 
    output 
          T/D connector 
            Tool’s torque sensor connection 
          AXIS I/O connector 
    External input and output control connection 
          MOTOR connector 
            Tools’ magnet motor connection 
          AC IN connector 
            AC200V~220V 3-phase power plug 
     
     
     
     
     
     
     
     
     
     
     
     
    CN 
    I/O 
    UEC- 
    F024 
    URYU
    AC 200-220V 
    MOTOR 
    T/D 
    RESOLVER 
    MON. 
    RS 
    485 
    RUN 
    BYPASS 
    SW1 
    NOK 
    OK 
    ALARM 
    M/D ALM 
    SP RUN 
    POWER 
    CON1 
    =========================================================== 
         10  
    						
    							
    ==========================================Chapter 3=========== 
     
     
        Manual operation switch 
          START manual switch (not in use) 
          REVERSE manual switch (not in use) 
          CAL manual switch 
          RESET manual switch 
     
        Data display operation switch 
          MODE switch 
          SET switch 
          DATA UP cursor switch 
          DATA DOWN cursor switch 
     
       Note: Display unit (UEC-MKB) is an option.  
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    UEC-MKB 
    SET 
    MODE 
    DATA 
    PARM D-NO 
    DATA 
    RESET REV CALSTART 
    CN 
    I/O 
    UEC- 
    F024 
    URYU 
    AC 200-220V 
    MOTOR 
    T/D 
    RESOLVER 
    MON. 
    RS 
    485 
    RUN 
    BYPASS 
    NOK 
    OK 
    ALARM 
     
    ============================================================ 
         11  
    						
    							
    ======Chapter 3=============================================== 
    3-1-2 UEC-F front panel front display
     
     
         
          POWER LED (Yellow) 
            AC200V power supply will switch on. 
     
          SP RUN (Orange) 
    Lighting while tightening is in process, and flushing 
    while reverse operation is in process. 
            Lighting when power supply is switched on. 
     
          M/D ALM. [MAIN/DRIVER ALARM] (RED) 
    Lighting when the servo amplifier-related is giving 
    error. 
     
          ALARM (RED) 
            Lighting when error occurs. 
     
          OK (GREEN) 
           Lighting when tightening is in normal operation. 
     
          NOK [NO OK] (RED) 
    Lighting or flushing when judgment has provided 
    out of standard result. 
     
    Lighting   :Torque value out of range 
    Rapid flushing :Angle value out of range 
    Slow flushing  :Time out of range 
     
          BYPASS LED (RED) 
    Lighting when spindle unit is non-operation status. 
     
     
     
     
     
     
     
     
     
     
     
     
    CN 
    I/O 
    UEC- 
    F024 
    URYU
    AC 200-220V 
    MOTOR 
    T/D 
    RESOLVER 
    MON. 
    RS 
    485 
    RUN 
    BYPASS 
    SW1 
    NOK 
    OK 
    ALARM 
    M/D ALM 
    SP RUN 
    POWER 
    CON1 
    ============================================================ 
         12  
    						
    							
    ==========================================Chapter 3=========== 
     
     
         
     
        Data display (4-digit) 
          Data display (torque and others) 
     
        PARM display (2-digit) 
          Parameter number display 
          Or, alarm number display 
     
        D-NO display (2-digit) 
          Data number display 
          Or, spindle unit number display 
     
        Note: Display unit (UEC-MKB) is an option. 
    UEC-MKB 
    SET 
    MODE 
    DATA 
    PARM D-NO 
    DATA 
    RESET REV CAL START 
    CN 
    I/O 
    UEC- 
    F024 
    URYU 
    AC 200-220V 
    MOTOR 
    T/D 
    RESOLVER 
    MON. 
    RS 
    485 
    RUN 
    BYPASS 
    NOK 
    OK 
    ALARM 
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    ============================================================ 
         13  
    						
    							
    ======Chapter 3=============================================== 
    3-2 Tool
     
     
     UNR-F015-350NT external appearance 
     
     
     
     
     
     
     
     
     
     
     
     
     UNR-801RM3-S external appearance 
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    ============================================================ 
         14  
    						
    							
    ==========================================Chapter 4=========== 
    Chapter 4    Installation and wiring
     
      How to set up 
          Conform to following instructions when you use UEC-F series system. 
     
    No. Item Contents Ref. 
    ① Select dust free control 
    box Give spindle unit specified intervals. 4-1
    ② Select cooling or heating 
    equipment. Have an appropriate one equipped 
    according to your environment. 2-1
    ③ Select circuit protector. Give eac h spindle unit circuit protector. 4-2
    ④ Select control equipment 
    (I/O). Connect only necessary control signals with 
    spindle unit. 4-3
    ⑤ Number switch setting of 
    spindle unit Number switch setting is made prior to 
    shipment.  Confirm the setting before 
    assembly. 4-4
    ⑥ Mount spindle unit to 
    control box Consider external dimensions and mount 
    spindle unit by giving intervals described in 
    4-1. 4-1
    ⑦ Power cord connection 
    with power socket Make connections by accessory 
    connectors. 4-2
    ⑧ Tool cable wiring Do  wiring  and  setting of pre-amplifier and 
    motor cables.  
    ⑨  Power supply Switch on power supply after wiring and 
    power voltage check. 5-1  
    Chapter 5 
    ⑩  Input setting values Input  torque  value, angle number, speed, 
    timer and etc. Chapter 6 
    ⑪  Initial action confirmation Make  initial action confirmation 5-2
        
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    ================================ ============================ 
         15  
    						
    							
    ======Chapter 4=============================================== 
    4-1 External dimensions and mounting dimensions
     
      Mounting 1 mounting slot at upper part M4 screw 
    2 deep holes at bottom part M4 screw 
     
      Weight  UEC-F024 1.4kg 
        UEC-F040 1.8kg 
     
     Handling instructions 
    1. Give right and left of spindle unit 10mm or greater space for 
    heat radiation. 
    2. Give spindle unit under space about 100mm distance for cable 
    wiring. 
     
     
    UEC-F024 type 
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    AC 200-220V 
    40 10 
    60 
    10 
    7.5 
    5 
    255 
    5 
    30
    12.5 
    5 
    30 
    5 
    CN I/O 
    URYU
    UEC- F024 
    MOTORT/D 
    RESOLVER
    MON. 
    RS 485 
    RUN 
    BYPASS 
    SW1 
    NOK OK ALARM M/D ALM SP RUN POWER 
    CON1 
    265 235 
    160 75 
    ============================================================ 
      16  
    						
    							
    ==========================================Chapter 4=========== 
     
     
     
     
     
     
     
     
     
     
        UEC-F040 type 
     
     
    14.5 
    265 235 
    160 75 
    AC 200-220V 
    40 10 
    60 
    10 
    7.5 
    5 
    255 
    5 
    30 
    12.5 
    5 
    30 
    5 
    CN I/O 
    URYU
    UEC- F040 
    MOTOR T/D 
    RESOLVER
    MON. 
    RS 485 
    RUN 
    BYPASS 
    SW1 
    NOK OK ALARM M/D ALM SP RUN POWER 
    CON1 
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    ============================================================ 
         17  
    						
    							
    ======Chapter 4=============================================== 
     
      UEC-F120 type 
     
      Mounting 2 mounting slots at upper part M4 screw 
    2 deep holes at bottom part M4 screw 
     
      Weight  UEC-F120 3.1kg 
         
     
     Handling instructions 
     
    1.     Give right and left of spindle unit 10mm or            
    greater space for heat radiation. 
    2. Give spindle unit under space about 100mm              
    distance for cable wiring. 
     
    90 
    UEC-F120 URYU 
    AC 200-220V 
    CON1 
    MOTOR 
    RESOLVER 
    CON1 
    MON. 
    RS 485 
    SW1 
    NOK OK ALARM M/D ALM SP RUN POWER 
    BYPASS RUN 
    CON1 
    265 235 
    5 
    7.5 
    12.5 
    255 
    5 5 5 
    16175
    60 
    5 14.5 15 15 
    15 15 60 
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    ============================================================ 
         18  
    						