==========================================Chapter 2=========== 2-2-2 Spindle unit CPU 32bit RISC Data communication RS485 (half duplex operation) 2 port 2-3 Functions 2-3-1 Functions (1) Tightening functions F-type nutrunner system will give you the following 9 options. 1. Torque control 2. Angle control 3. Plastic area angle control 4. Spline fit-in control 5. Pin hole control 6. Pre-load controls 7. Idle running control 8. Spline angle control 9. Yield control (2) Non-operation (BYPASS) function Spindle unit outputs BYPASS signal indicating non-operation status when you input BYPASS signal or select BYPASS of front panel RUN/BYPASS. START signal does not switch on spindle uni t under this status and SYNC signal becomes high impedance in order not to give synchronized tightening affections. Spindle unit stops tightening when the status turns into non-operation status. While in non-operation status, spindle unit will tell you non-operation by LED [BYPASS] lamp in the front panel flushing. (3) Signal output functions wh en NOK or Alarm takes place When tightening NOK or alarm takes the place, spindle unit stops tool running with corresponding error signal number output and contents of NOK and alarm number display on the front panel. ================================ =========================== 9
======Chapter 3=============================================== 3-1 UEC-F panel (spindle unit) 3-1-1 UED front panel switch and connector Status change switch RUN/BYPASS change switch RUN : Operation possible status BYPASS: Non-operation status External communication device RS485 connector RS485 connector Connector Resolver connector Tool’s resolver connection MON. connector (monitor output) Analog electric pressure of torque and angle pulse output T/D connector Tool’s torque sensor connection AXIS I/O connector External input and output control connection MOTOR connector Tools’ magnet motor connection AC IN connector AC200V~220V 3-phase power plug CN I/O UEC- F024 URYU AC 200-220V MOTOR T/D RESOLVER MON. RS 485 RUN BYPASS SW1 NOK OK ALARM M/D ALM SP RUN POWER CON1 =========================================================== 10
==========================================Chapter 3=========== Manual operation switch START manual switch (not in use) REVERSE manual switch (not in use) CAL manual switch RESET manual switch Data display operation switch MODE switch SET switch DATA UP cursor switch DATA DOWN cursor switch Note: Display unit (UEC-MKB) is an option. UEC-MKB SET MODE DATA PARM D-NO DATA RESET REV CALSTART CN I/O UEC- F024 URYU AC 200-220V MOTOR T/D RESOLVER MON. RS 485 RUN BYPASS NOK OK ALARM ============================================================ 11
======Chapter 3=============================================== 3-1-2 UEC-F front panel front display POWER LED (Yellow) AC200V power supply will switch on. SP RUN (Orange) Lighting while tightening is in process, and flushing while reverse operation is in process. Lighting when power supply is switched on. M/D ALM. [MAIN/DRIVER ALARM] (RED) Lighting when the servo amplifier-related is giving error. ALARM (RED) Lighting when error occurs. OK (GREEN) Lighting when tightening is in normal operation. NOK [NO OK] (RED) Lighting or flushing when judgment has provided out of standard result. Lighting :Torque value out of range Rapid flushing :Angle value out of range Slow flushing :Time out of range BYPASS LED (RED) Lighting when spindle unit is non-operation status. CN I/O UEC- F024 URYU AC 200-220V MOTOR T/D RESOLVER MON. RS 485 RUN BYPASS SW1 NOK OK ALARM M/D ALM SP RUN POWER CON1 ============================================================ 12
==========================================Chapter 3=========== Data display (4-digit) Data display (torque and others) PARM display (2-digit) Parameter number display Or, alarm number display D-NO display (2-digit) Data number display Or, spindle unit number display Note: Display unit (UEC-MKB) is an option. UEC-MKB SET MODE DATA PARM D-NO DATA RESET REV CAL START CN I/O UEC- F024 URYU AC 200-220V MOTOR T/D RESOLVER MON. RS 485 RUN BYPASS NOK OK ALARM ============================================================ 13
======Chapter 3=============================================== 3-2 Tool UNR-F015-350NT external appearance UNR-801RM3-S external appearance ============================================================ 14
==========================================Chapter 4=========== Chapter 4 Installation and wiring How to set up Conform to following instructions when you use UEC-F series system. No. Item Contents Ref. ① Select dust free control box Give spindle unit specified intervals. 4-1 ② Select cooling or heating equipment. Have an appropriate one equipped according to your environment. 2-1 ③ Select circuit protector. Give eac h spindle unit circuit protector. 4-2 ④ Select control equipment (I/O). Connect only necessary control signals with spindle unit. 4-3 ⑤ Number switch setting of spindle unit Number switch setting is made prior to shipment. Confirm the setting before assembly. 4-4 ⑥ Mount spindle unit to control box Consider external dimensions and mount spindle unit by giving intervals described in 4-1. 4-1 ⑦ Power cord connection with power socket Make connections by accessory connectors. 4-2 ⑧ Tool cable wiring Do wiring and setting of pre-amplifier and motor cables. ⑨ Power supply Switch on power supply after wiring and power voltage check. 5-1 Chapter 5 ⑩ Input setting values Input torque value, angle number, speed, timer and etc. Chapter 6 ⑪ Initial action confirmation Make initial action confirmation 5-2 ================================ ============================ 15
======Chapter 4=============================================== 4-1 External dimensions and mounting dimensions Mounting 1 mounting slot at upper part M4 screw 2 deep holes at bottom part M4 screw Weight UEC-F024 1.4kg UEC-F040 1.8kg Handling instructions 1. Give right and left of spindle unit 10mm or greater space for heat radiation. 2. Give spindle unit under space about 100mm distance for cable wiring. UEC-F024 type AC 200-220V 40 10 60 10 7.5 5 255 5 30 12.5 5 30 5 CN I/O URYU UEC- F024 MOTORT/D RESOLVER MON. RS 485 RUN BYPASS SW1 NOK OK ALARM M/D ALM SP RUN POWER CON1 265 235 160 75 ============================================================ 16
==========================================Chapter 4=========== UEC-F040 type 14.5 265 235 160 75 AC 200-220V 40 10 60 10 7.5 5 255 5 30 12.5 5 30 5 CN I/O URYU UEC- F040 MOTOR T/D RESOLVER MON. RS 485 RUN BYPASS SW1 NOK OK ALARM M/D ALM SP RUN POWER CON1 ============================================================ 17
======Chapter 4=============================================== UEC-F120 type Mounting 2 mounting slots at upper part M4 screw 2 deep holes at bottom part M4 screw Weight UEC-F120 3.1kg Handling instructions 1. Give right and left of spindle unit 10mm or greater space for heat radiation. 2. Give spindle unit under space about 100mm distance for cable wiring. 90 UEC-F120 URYU AC 200-220V CON1 MOTOR RESOLVER CON1 MON. RS 485 SW1 NOK OK ALARM M/D ALM SP RUN POWER BYPASS RUN CON1 265 235 5 7.5 12.5 255 5 5 5 16175 60 5 14.5 15 15 15 15 60 ============================================================ 18