Page 11
[email protected] 11 Sending Back Data Results to SQnet FTA In the same way the route was uploaded to Freedom³, user can collects data by USB cable communication from Freedom³ to SQnet FTA. After data results are downloaded, SQnet FTA will display the status of every single tightening, the associated statistic, torque/time and torque/angle curves. SQnet FTA
Page 12
12 12 Freedom³ PRW mode Tour Freedom³ PRW mode function table In Brief: LIST OF FUNCTIONS PRW Version and Memory: Working with all firmware version Yes Store data-results and curves in Freedom³ memory Yes Programming: Edit tests directly on Freedom³ X Route from/to SQ-Net Yes Receive program from VPG in real time Yes Send data and Curves to F3 Explorer X SPC Quality Control test Yes Production Tightening Yes Joint Analysis X Continuous Reading Yes Cp/Cm Test X Counter...
Page 13
[email protected] 13 Freedom³ PRW mode Options and Software table In Brief: List of Functions PRW Options: Internal Bar Code Reader Yes Bluetooth Integrated Module Yes 868 MHz Integrated Module Yes WiFi Integrated Module Yes Automatic Socket Recognition Yes Rubber Protection Yes Rubber Protection with Display Protection Yes Single Battery Charger (External) Yes Dual Battery Charger (External) Yes Software SQnet FTA software Yes F3 Explorer software X VPG...
Page 14
14 14 SYSTEM OVERVIEW SYSTEM OVERVIEW In the following chapters we will show the main technical Characteristics of Freedom³ . Technical Specification Torque Capacity (Nm) Connection (end- Fitting) L1 (mm) L2 (mm) Weight (kg) 15 9x12 Female 375 393 0,8 30 9x12 Female 375 393 0,86 70 9x12 Female 480 498 0,93 100 9x12 Female 480 498 0,93 200 14x18 Female 604 629 1,5 300 14x18 Female 754 779 1,86 400 14x18 Female 854 879 2 600 14x18 Female 1032 1057 3,65 800 Ø 20 1250...
Page 15
[email protected] 15 Measurement accuracy: ±0.5% deviation between 20% and 100% of torque capacity ±1% deviation between 10% and 20% of torque capacity ±0.1°angle display deviation Performance: Internal Memory 1 GB. 20000 results; 20000 curves; 1000 Programs Settable. 2.8” Touch-Screen (for easy and fast navigation). High Resolution. Display 320 x 240 pixel, 65535 colors. Keyboard (for switching on/off and navigation). Barcode Reader (to add vin-number info to the...
Page 16
16 16 SYSTEM OVERVIEW Connections Ports and Interfaces: Mini-B USB 2.0 (For SCS software and battery charger Connection) 4 Pin connector for battery charging by cradle (optional) Keyboard and touch screen for programming and navigation:
Page 17
[email protected] 17 1 led green and 1 led red to indicate the status of the tightening or test: 7 led blue to indicate the tightening progression: Software To allow users to download data or communicate with PC, we developed 3 software, F3 Explorer (for Lab version) and SQ-Net (for SPC version). VPG Visual Production Guide (for PRW version) The minimum system requirements to install and use SQnet FTA: CPU: Pentium II Hard Disk Space: 100 MB...
Page 18
18 18 Starting Starting To work with Freedom³ PRW mode, user has to upload a route by SQnet FTA, in the following paragraphs we will show how to start quickly to work with Freedom³ and SQnet FTA. With Freedom³ PRW is not possible to create program directly from the wrench.
Page 19
[email protected] 19 PRW mode working with SQnet FTA Introduction: PRW mode is a firmware version of Freedom³ that allows user to work in remote way, programming Freedom³ from SQnet FTA software. In PRW mode is not possible to edit programs locally (only for Lab mode). To program Freedom³ is necessary to install SQnet FTA on PC. In the next paragraphs we will show you how send/receive a route (list of test) from/to SQnet FTA and how execute test. SQnet FTA As explained in...
Page 20
20 20 PRW mode working with SQnet FTA Build a tree structure and edit Location with SQnet FTA Start SQnet FTA and: Click on SQnet FTA icon to run it Select “test definition” icon from main page of SQnet FTA: