Page 41
39 2.8.2 Select Parameter Set To view results of all saved rundowns, regardless of Paramete r Set, select zero (0) To view results of rundowns for a specific Parameter Set, select the appropriate Parameter Set number To select the colums you want to see, select cus tom and choose the columns from the selection menu You can restrict the number of rundowns you want to see by selecting the Max. Rows (0 means all) The Rundowns are ordered by latest first. So the Recent...
Page 42
40 Figure 2.8 Rundown Log example 2.9 Log Info Log info describes the usage of the Controller and the tools that have been used with that controller. POR Counts - Number of times the controller power has been cycled. Controller Cycles - Number of rundown the controller has completed . Tool Log - Displays history of tools that have been previously connected to the controller . Monthly Usage - Displays history of the number of rundowns the controller has preformed...
Page 43
41 Figure 2.9 Tool / controller Log Info example 2.10 Statistics The statistics page takes a collection of final torque samples from a rundown file then calculates and displays statistical information about the collection. In addition, a histogram is plotted, and the fi nal torque for each rundown is displayed graphically. The maximum number of rundowns that can be evaluated is 2048. If more data is stored in the file, then data for only first 2048 rundowns are used. Torque...
Page 44
42 Figure 2.10 Statistics screen example PSet Selection (Parameter Set): a. Only rundowns with the PSet selected are used in the collection. In addition, Only Rundowns with settings for Torque High Limit, Torque Low Limit, and Target that match the first rundown are used in the collection. b. If 0 is selected for the PSet, all rundowns in the file will be used in the collection.
Page 45
43 Stats: POP: Population; The total number of observations used to calculate the statistical data. Mean: (Sum of All Readings) / (Number of Readings) CP: Overall capability, which is the ratio of 6 sigma to the tolerance. The equation for CP is: (Torque High Limit – Torque Low Limit) / 6 Sigma CPK: Process capability, which takes both sigma and mean into account. The equation for CPK is the smaller of: (Torque High Limit – Mean) / 3 Sigma or (Mean – Torque Low...
Page 46
44 Histogram of Final Torque Samples The histogram shows the frequency count of the number of times that a specified interval, or bin, occurs in the collection of final torque samples. The range of the histogram is equally divided in to a specified number bins using the following equations: The width of the frequency bin is o o Where: m is the selected Number of Bins . max is the upper ceiling for the torque range to be evaluated ( Range Ceiling ) min is the...
Page 47
45 Final Torque Sample Graph The Final Torque Sample graph shows the final torque of each rundown in the collection. For reference, the Parameter Set values for Torque Hi, Torque Low, and Torque Target are taken from the first rundown in the collection and plotted as vertical lines. 2.11 AcraVision AcraVision displays the current rundown information in an easy to read screen. If there is a failure in the tightening the Torque/Angle is displayed in red. Use Record Rundowns...
Page 48
46 2.12 System 2.12.1 Serial Test Hyper -terminal like screen that can be used to monitor the serial output messages from the iEC controller 3. Addendum 3.1 Fault codes Fault codes are displayed to inform the operator about what is happening in the Controller and why something doesn’t behave as expected. Figure Add.3.1 Fault Codes
Page 49
47 3.2 Trouble Shooting Fault Description TID Timeout: No Communication between the tool and controller. This fault condition is usually caused by a problem in the tool ID board. Try connecting another tool to the controller Tool GND: The tool ground loop is broken. This fault condition is usually caused by a problem in the controller or tool . Try the tool and cable on another controller. The fault can be intermittent. Power on Throttle: The System thinks that the throttle is...
Page 50
48 Tool Level: The tool transducer output voltage has exceeded the maximum or minimum allowable value. Try the tool on another system. Locked rotor : The controller has not sensed hall transitions from the motor for a period of time. This is possible if the tool is trying to achieve a high torque at a low speed. Increase the rundown speeds and make sure the tool is calibrated properly. It is also possible that the controller is faulty. If the tool does not run at all try connecting it to a...