Page 31
29 1. Press and hold trigger 2. Press and hold MFB 3. Release t rigger 4. Release MFB Press and Hold Option 1. Hold trigger down for x seconds to latch throttle. No Latch Option (Default) Serial Output Format This function allows the user to select the format of the information in the ASCII character string packet that is sent out of the controller via the RS232 Port. a) Standard Output : Format: O P HHHHH LLLLL TTTTT P HHHHH LLLLL AAAAA CR CR O: Overall...
Page 32
30 HHHHH: Angle High Limit LLLLL: Angle Low Limit AAAAA: Angle Result NAC%: Msg End CR LF c) Standard Output with CR/LF Format: O P HHHHH LLLLL TTTTT P HHHHH LLLLL AAAAA 1 CR LF O: Overall Pass/Fail P: Tq Pass/Fail HHHHH: Tq High Limit LLLLL: Tq Low Limit TTTTT: Tq Result P: Angle Pass/Fail HHHHH: Angle High Limit LLLLL: Angle Low Limit AAAAA: Angle Result 1: PSet ( “1” – “9”) for PSet s 1-9, (“A” – “W”) for PSets 10-32 CR LF d)...
Page 33
31 Statistics Minimum Stats - Number of rundowns that need to be preformed before the statistics will be calculated and displayed on the controller . Stat Samples - Maximum number of rundowns used for calculating and displaying statistical data on the iEC controller. Statistical Outliers - The statistical outliers’ parameter is a code that is used to determine if the data from a rundown will be excluded from the data set being used in the static calculations that are displayed on...
Page 34
32 even when the desired RPM is extremely slow. IEC controllers are able to run this feature assuming the servo in the controller is REVB or higher and SCC code is 1.16 or higher. SCC installed code and Servo REV level is indicated each time the controller is powered on. This information is visible on the LED display. Controllers capable of Low Speed Control mode default to standard control unless selection of Low Speed Control is consciously made. Confirmation of Low Speed Control...
Page 35
33 o If a rundown is rejected, the beeping can be stopped by making a successful rundown or using the MFB option "Stop Reject Tone". Headlight ON - Enables or Disables the Headlight. 2.6.3 Angle Offset Calibration Angle Calibration Value: The value for this will determine how much to add or subtract to the angle measured and reported by the iEC controller. The offset is added at the start of threshold. The default value for this is 100. The range is 1...
Page 36
34 2.7 Tool 2.7.1 View Tool Parameters Reads all the tool parameters and displays on the screen T orque Cal Value Shows the current calibration value of the tool as well as the factory calibration RPM’s Performing this test will determine the actual RPM of the tool. Cycle Count Displays the total number of rundowns on the tool good or bad 2.7.2 Edit Tool Setup Each tool has a special parameter file that defines the tool. You can view the parameter file...
Page 37
35 Figure 2.7.2 Tool Configuration and tubenut tool setup Multiplier - Configures the tool to include gearing added to the base model. Units: Gear Ratio * 100. a. Example: Adding a multiplier with a gear ratio of 5:1, Multiplier setting = 5. Obstruction Torque - In 1st 90° degrees of rotation in the tightening direction cycle will be aborted if this torque is exceeded. If the tool rotates 90° degrees and stops without any obstruction, the value is too low.
Page 38
36 Open Loop - After reaching the open position, this open loop torque prevents the socket from bouncing to a partially closed position. This torque should be set to a value slightly less than the tube nut home torque. Home - In the reverse direction, reaching this torque indicates to the controller the socket is in the open position. If the socket does not attempt to return to the open position or returns at an extremely fast rate this value is too low. AcraDyne recommends starting at about...
Page 39
37 Buttons and LED’s Calibrate Buttons - After a tool has been worked on, it is possible the relationship between hall sensors and magnet have changed. Using the Tool Button Calibration screen calibrates the field between the two. Test Trigger, Ccw, Center and Cw positions and send the values t o the Tool. LED States - Turns the tool lights on, off, or flashes. Used for testing of the Tool Figure 2.7.4 LED programming and button calibration Service and Calibration Log...
Page 40
38 2.7.5 Tool Service and Calibration Log 2.8 Rundowns Data for rundowns in all or selected Parameter Sets can be displayed in a tabular format. This information can then be saved as a “Ms.csv” File. You can print the rundown results by using File - >Print in the menu. Rundowns must be saved to a file before the statistics function can be used to evaluate the data. Controller memory can be cleared by clicking the “Clear iEC Rundown Memory” button 2.8.1...