Aimco Brakes AcraDyne ToolWare v3010 Manual for iEC Systems
Here you can view all the pages of manual Aimco Brakes AcraDyne ToolWare v3010 Manual for iEC Systems. The Aimco Brakes manuals for AcraDyne are available online for free. You can easily download all the documents as PDF.
Page 11
9 Figure 1. 5.2 iEC controller electrical interface, top panel (Some connections available on iEC3 and iEC4 models only RJ45 CAT 5E Regular Cable Straight through pin out Ethernet Port1 Ethernet Port2 COM1 RS232 Tool Cable COM2 Bar Code Scanner
Page 12
10 1.5.1 Connecting to USB port 1.5.2 Connecting to Ethernet Port 1.5.3 Connecting to the network 2. Working with ToolWare 2.1 Connecting PC with the Controller 2.1.1 Setting up USB Connection Follow the steps below to set up USB connection. Turn on the computer. Plug the USB cable (PN: 22940) into your computer’s USB Port or USB Hub and the other end to the CIM Module (PN: 23112). Plug the 23217 cable into the connector on the CIM and the other end of the...
Page 13
11 Launch ToolWare and configure it for USB connection by selecting File /Connection/USB . 2.1.2 Setting up Ethernet Connection Make physical connection Connection options: Use Ethernet crossover or standard cable to connect Controller to PC directly. Use Ethernet crossover or standard cable to connect Controller to network router. Specify the IP Address of controller in the PC Open Control Panel by clicking . Select for configuration. Double click to...
Page 14
12 Successful Connection A successful Ethernet connection will be indicated by the following text on the main screen of the ToolWare program:
Page 15
13 2.2 Setting Parameters In ToolWare, select from the top menu or select directly from the lower menu to open window shown in the Figure 2. 2. ToolWare can send and receive up to 32 Parameter sets to the controller. Figure 2. 2 Parameter Sets View/Edit Window
Page 16
14 2.2.1 Parameter Entry Fields Strategy - Select one of four fastening strategy options . o Tc - Torque Control strategy uses torque as the only control parameter. The Tool stops when Tq Target is reached. Rundown is considered to be successful ( Accept) if the final torque value falls within the range specified by Tq High Limit and Tq Low Limit parameters. o Tc-Am - Torque Control /Angle Monitoring strategy is convenient for detection of cross threaded or stripped fasteners....
Page 17
15 Angle High Limit - is used for Accept / Reject decision. Rundown does not pass if the measured final angle exceeds this limit. Angle Target - the target angle value Angle Low Limit - used for Accept / Reject decision. Rundown does not pass if the final angle is below this limit. Rpm Freespeed % - specifies initial tool output -drive speed. The parameter is expressed as a percentage of the tool ’s maxim um rated speed. Rpm Downshift % - specifies the...
Page 18
16 Linked PSet Results Reporting: The angle count is reset to 0 at the end of each linked step of a Linked PSet rundown. RBR Combined with a Linked PSet Rundown Note: The RBR, RB, and RBsp, options are only preformed at the end of the last step of a Linked PSet rundown Results Reporting: The results of the last PSet Step in the group are used to report. If the trigger is released before the rundown sequence is complete, the results from the step that the...
Page 19
17 2.2.2 Parameter Sets Parameter Enable - check boxes allow the user to generate up to 32 different sets of parameters. Each set can be used individually or sets can be arranged into batch sequence. If the box is unchecked and the parameters are sent to the controller it deletes the parameter set. Copy - button allows the user to copy one set of parameters into another. The user must specify the des tination parameter set number. Delete - removes parameter from overall set....
Page 20
18 2.3 CurveWare In ToolWare , select from the top menu or select < CurveWare> directly from the lower menu to open < CurveWare> window shown in the Figure 2. 3. Only rundown information after most recent Power On of the controller can be graphed . Figure 2.3 CurveWare example Max Torque - is the upper torque limit of the rundown Max Angle - is the upper angle limit of the rundown No. of Data Points - is the number of data points that should be used in the plot ....