Have a look at the manual Aimco Brakes AcraDyne iEC iControl DC Tool Controller Users Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 85 Aimco Brakes manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
11 Using the Optional Keypad Display Module (KDM) 1—KDM Display Screen 2—KDM Power On / Off Button 3—Shift Button—used to access alternate functions on highlighted buttons 4—SEND Button—Used to send new or edited parameter sets to the tool and controller 5—Numerical / Alternate Function keypad Parameter Set Terms ANGLE CONTROL / TORQUE MONITOR— Control strategy in which angle is the control parameter, but torque is monitored. ANGLE TARGET— Desired value for angle rotation; measured from threshold torque value. AUTO-SET— Feature that allows manual entry of control parameters, but all others are determined by system defaults. CYCLE COMPLETE— Torque level that determines t he completion of a fastening cycle. THRESHOLD— The torque value above which the system is , “in cycle” and data points are stored. DOWNSHIFT TORQUE— Torque level at which the spindle changes from free speed to downshift speed. ERGO MODE—Ramps the cut-off of power after reaching target torque, providing an ergonomic shutoff during a hand-held tightening operation. ( Can negatively effect cpk calculations ) HI LIMIT— The upper control limit for torque and/or angle. LO LIMIT— The lower control limit for torque and/or angle. Must be set lower than target parameter. Any torque/angle lower than this value will be indicated by a yellow light and with a Lo Torque and/or Low Angle error on KDM. RPM FREE— Spindle output speed at the beginning of a tightening cycle, entered as a percentage of maximum tool speed. RPM DOWN—Spindle output speed after exceeding downshift torque; entered as a percentage of maximum tool speed. SSTART—(Soft Start) Speed of output spindle ramps up at a programmabl e rate to RPM free speed; allows the operator or system to engage the socket onto the fastener in a more controlled fashion. TARGET TORQUE—Torque level which, when achieved, causes the power to the drive motor to be cut off. TORQUE CONTROL— Control strategy in which torque is the only control parameter. TORQUE CONTROL / ANGLE MONITOR— Control strategy in which torque is the control parameter, but rotational angle is monitored. A valuable strategy for controlling torque wh ile also checking for cross threaded or stripped fasteners. 4 3 2 1 5
12 Turning the KDM On After turning on the iEC Controller (describ ed in Initial Set-up, Pg. 6), press the POWER button on the KDM. The following text will be shown on the KDM Display Screen: Turning the KDM Off 1) Turning off the iEC Controller (detailed in Initial Set-up, Pg. 6) 2) Pressing the POWER button on the KDM for 2 seconds. Note: The KDM does not support Psets above 8, Linked Ps ets, or Batch Control. These features are available via Toolware 3.0 or greate r. Main Menu: 1) Parameter Setup Starting from the Main Menu, a variety of functions can be access ed through the KDM. Programming, calibration, controller set-up, security set-up, and error analysis can all be achieved through properly using the KDM. The following sections will det ail the Menu Structure of the KDM and the various functions within each area. Setting Up Parameter Sets This section will detail how to se t up parameter (PSETS) sets for assembly by using the KDM. There are two methods of programming a PSET—Quick Start or Configure. QUICK START: Quick Start Mode only requires the user to select the desired parameter set and target torque. All other values are set according to the system defaults (further explained in the ADMIN section—see Page 17). CONFIGURE: Configure Mode allows the operator to set up a new param eter set or edit all programmable operating functions for an existing parameter set. Using the Optional Keypad Display Module (KDM) The Optional KDM allows for quick access to the IEC Control programming features. Not all features are accessible by use of the KDM. For access to higher level features (i.e..Batch Programming, Button Options, Linked PSet) please use a PC connected to the controller and the ToolWare software interface program.
13 Accessing Quick Start Parameter Sets From the MAIN MENU, press 1 for SETUP PSET Press 1 for QUICK START The following text will be disp layed on the KDM display screen: Choose from EDIT PSET or CONFIG PSET. See the following sections for instructions on editing or configuring Quick Start parameter sets. Editing Quick Start Parameter Sets Depending on the number of Parameter Sets that have previously been programmed into the iEC Controller, the user will have the option of choosing from 1 to 8 parameter sets to edit. Press the number of the Parameter Set that is to be edited. The following text will be displayed on the KDM display screen: To change the target torque value in .1 unit increments press To change the target torque value in 1.0 unit increments press After the target torque is entered correctly, press Verify that the correct parameter set is active by observing the PSET Indicator on the Main Display Panel. If the desired parameter set is not active, press CHANGE PSET to cycle through the ava ilable parameter sets until the appropriate set is displayed. The tool is now ready to be run to the appropriate target torque value. Using the Optional Keypad Display Module (KDM) 2 8 or SEND SHIFT + 2 or SHIFT + 8
14 Using the Optional Keypad Display Module (KDM) Configuring New Quick Start Parameter Sets Depending on the number of Parameter Sets that have previously been programmed into the iEC Controller, the new parameter set will automatically be assigned a value from 2 through 8. Press the number on the KDM that corresponds to the number for the next parameter set to be configured. For example, if the following text were to be displayed in the Quick Start screen: the user would press 4 on the keypad to configure a new Quick Start Pset. The following text will be disp layed on the KDM display screen: To change the target torque value in 0.1 unit increments press To change the target torque value in 1.0 unit increments press After the target torque is entered correctly, press Verify that the correc t parameter set is active by observing the PSET Indicator on the Main Display Panel. If the desired parameter set is not active, press CHANGE PSET to cycle through the available parameter sets until the appropriate set is displayed. The tool is now ready to be run to the appropriate target torque value. When exiting from Quick Start mode, all torque values ar e cleared from the KDM. Upon re-entering Quick Start mode, target torque values for all parameters will be set to the value determined by applying the default percentage to the tool that is connected to the controller. Configuring a Complete Parameter Set For a detailed explanation of each of the programmable functions within a parameter set see the list of key terms in Parameter Set Terms on page 11. From the MAIN MENU, press 1 for SETUP PSET Press 2 for CONFIGURE The following text will be disp layed on the KDM display screen: 2 8 or SEND SHIFT + 2 or SHIFT + 8 !
15 Using the Optional Keypad Display Module (KDM) Depending on the number of Parameter Sets that have previously been programmed into the iEC Controller, the user will have the option of choosing fr om 1 to 8 parameter sets to edit. If the user chooses to configure a new parameter, the next set will be assigned t he next available PSet value, up to 8. Press the button on the KDM corr esponding to the PSET that will be edited or configured. The following text will be displa yed on the KDM display screen: If editing a parameter set, the Control Strategy (definitions on page 11) of the PSET will be identified by an asterisk. Press the button on the KDM correspond ing to the desired Control Strategy. The following text will briefly be displayed on the KDM display screen: followed by the following text: The PS# text in the bottom-right corner of the display is fo r the users reference and identifies the PSET that is being configured or edited. Entering / Editing Values in the KDM The flashing cursor highlights which field can be changed. Two possibilities exist for entering values into a field, depending on which function is being programmed: For numeric values, press the appropriate key on the KDM. For YES or NO entries, press When an < and/or > symbol appears in the upper-right corner of the KDM display, this notifies the user that additional functions may be accessed by scrolling to the previous or next page of text. To scroll to one of these pages, press ! SHIFT + or SHIFT + 1 YES 3 NO SHIFT + 4 or SHIFT + 6
16 Using the Optional Keypad Display Module (KDM) To move to and modify the next or previous function, press The cursor will then highlight t he field that can be modified. To clear a mistakenly entered value, press When all functions have been modified appropriately, press Verify that the correc t parameter set is active by observing the PSET Indicator on the Main Display Panel. If the desired parameter set is not active, press CHANGE PSET to cycle through the available parameter sets until the appropriate set is displayed. The tool is now ready to be run to the appropriate target torque value. The AUTO-SET function is under development fo r future versions of the iEC controller. If the user exits the CONFIGURE mode before pressing all edits and modifications that have been entered will be lost and the entries will revert back to the previous value. Main Menu: 2) Calibration The Auto Cal is non functional for the user. SHIFT + 2 or SHIFT + 8 SEND ! ! SHIFT + DEL SEND
17 Main Menu: 3) Administration Functions Parameter Set Defaults Parameter set defaults are the values used to calculat e control parameters when using either Quick Start or Auto Set. This is also the area where units of measurement for all parameters is set. To access the Parameter Set Default function: From the MAIN MENU, press 3 for ADMIN Press 1 for SETUP PSET The following text will be disp layed on the KDM display screen: Navigation and value-entry is the same as described in the section Setting Up Parameter Sets on pages 12—16. All programmable default values are described below: TQTARGET%: The default torque target shown when entering quick programming. The value entered is a percentage of the maximum torque of the tool. For ex ample, if the value entered is 80 and the maximum torque of the tool is 30 Nm, the default target torque when entering quick programming will be 27.0 Nm. TQ+/-%: The default percentage used for high and low torque limit. The value entered is a percentage of target torque. TQTHOLD%: The default torque threshold. The value entered is a percentage of target torque. TQDSHIFT%: The default setting for torque downshift point. The value entered is a percentage of target torque. CYCCOMP%: The default setting for cycle complete torque. The value entered is a percentage of target torque. RPMFREE%: The default setting for RPM free speed. The value entered is a percentage of maximum output speed in revolutions per minute (RPM ). 3000 series AcraDyne tools operating at 120V will run at 1/2 of the programmed speed. RPMDOWN%: The default setting for spindle speed after crossing the downshift torque level. The value entered is a percentage of maximum output spindle speed in revolutions per minute (RPM). UNITS: The default engineering units for operation. The KDM is only capable of using one engineering unit for all parameter sets. Changing the units in th is section will affect all parameters sets. Using the Optional Keypad Display Module (KDM)
18 Using the Optional Keypad Display Module (KDM) Security The security function allows the user to set up a password in order to prevent unauthorized persons from altering the programming of the iEC controller. Once the password function is activated, the user will be prompted to enter the correc t password whenever attempting to navigate past the Main Menu. If the user changes the password and then loses or forgets the new password, the Factory Default password will still allow the user to access all menus and functions . Please call your AIMCO sales representative for assistance in ent ering the Factory Default Password. To access the ADMIN SECURITY function: From the MAIN MENU, press 3 for ADMIN Press 2 for SECURITY The following text will be displa yed on the KDM display screen: If the password function is already enabled, the text will read 1) DISABLE PWORD To activate the password function, press 1) ENABLE PWORD To enter a new password, press 2) CHANGE PWORD The following text will be displa yed on the KDM display screen: Enter a 4-digit password. Once the four digits are entered, the user will automatically be prompted to confirm the password. When the correct password is c onfirmed, the following text will briefly be displayed on the KDM display screen: !
19 Using the Optional Keypad Display Module (KDM) Tool Information This section of the ADMIN menu provides the user wi th useful information regarding the tool that is currently connected to the iEC controller. This information may be needed for reference when setting up parameter sets or calibrating the tool. The items that can be viewed in TOOL INFO are: ID : The serial number for the tool Tq: The maximum torque rating of the tool, in the units that are selected in PSET DEFAULTS Speed : The maximum output-spindle speed of the tool in revolutions per minute (RPM) CAL : The scaled value that correlates the voltage signal of the transducer to a torque value To access the ADMIN SECURITY function: From the MAIN MENU, press 3 for ADMIN Press 3 for TOOL INFO Reset Factory Defaults The RESET DEFAULTS menu allows the user to quickly reset the iEC Controller setting to the original factory default values. The values that can be reset are: 1) TOOL CAL VALUE 2) LOGIC I/O 3) PARAMETER SETS To access the RESET DEFAULTS MENU: From the MAIN MENU, press 3 for ADMIN Press 4 for RESET DEFAULTS (this choice can also be viewed by scrolling to the next text page to view the additional ADMIN MENU options) The following text will be displa yed on the KDM display screen: The user can then select the values to reset by pressing the corresponding number on the keypad.
20 Using the Optional Keypad Display Module (KDM) The user will be prompted to confirm the desir e to reset values with the following text: To select Y and confirm the desire to reset the values, press To cancel the reset process, press Error Codes By default, the iEC Controller only displays Error Co des in the Primary and Secondary Display Fields of the Main Display Panel (Figures 1 & 4). These erro rs will display automatically when recorded. Error codes are listed in Appendix A in this users guide. For additional information on Error Codes contact AcraDyne Technical Support or your AIMCO representative. Filter Frequency The Filter Frequency is non functional for the user. SHIFT + 1 YES SHIFT + 3NO