Home > ADT Security Services > Home Security > ADT Security Services Safewatch Pro 3000 Entrepreneur 3000 User Manual

ADT Security Services Safewatch Pro 3000 Entrepreneur 3000 User Manual

Here you can view all the pages of manual ADT Security Services Safewatch Pro 3000 Entrepreneur 3000 User Manual. The ADT Security Services manuals for Home Security are available online for free. You can easily download all the documents as PDF.

Page 31

– 31 –
6HFXULW\&RGHV	$XWKRULW\/HYHOV&RQW
+RZ7R$VVLJQ8VHU&RGHVDQG$WWULEXWHV
The following lists the various command strings for adding user codes and attributes.
Refer to the User Setup chart at the back of this manual for factory
assignments of user attributes and to keep a record of user programming.
NOTE: Partition Master codes apply only to those user numbers previously assigned
(by the system master/installer) to the partition master’s partition.
Add User Code: 
 System/Partition Master...

Page 32

– 32 –
$FFHVVLQJ2WKHU3DUWLWLRQV
*272&RPPDQGDQG0XOWL3DUWLWLRQ$UPLQJ
$ERXW$FFHVVLQJ3DUWLWLRQV
Each touchpad is assigned a default partition for display purposes, and will show only
that partitions information.
·If the user is authorized, a touchpad in one partition can be used to perform
system functions in the other partition by using the GOTO command. Refer to
the GOTO section.
·If the user is authorized, that user can arm other partitions. Refer to the Multi-
Partition Arming section.
The...

Page 33

– 33 –
$FFHVVLQJ2WKHU3DUWLWLRQV&RQWLQXHG
8VLQJWKH*R7R&RPPDQG
If the user is authorized, a touchpad in one partition can be used to perform system
functions in the other partition by using the GOTO command.
·You must use a Custom English touchpad to access another partition.
·Touchpads automatically return to their original partition after 2 minutes
with no touchpad activity.
1.  
          +  [*] + partition number (0,1,2,3)
(Security Code)
0 = return to touchpad’s original partition.
1 =...

Page 34

– 34 –
$FFHVVLQJ2WKHU3DUWLWLRQV&RQWLQXHG
&RPPRQ=RQH2SHUDWLRQ
Ask your installer if a
common zone was
assigned. If so, check
this box      
Your system may have been set up to use a common zone, which is
an area shared by users of both partitions, such as a foyer or lobby.
If so, please note the following:
·The common zone will sound and report alarms only when 
both
partitions are armed. If only one partition is armed, the system
ignores faults on the common zone.
·Either partition may arm its...

Page 35

– 35 –
6FKHGXOLQJ
$ERXW6FKHGXOLQJ
The system provides up to 16 end-user schedules (programmable by master/installer
only), which can be used to control various types of events.
· Each schedule causes a defined event to start and stop (when appropriate) at a
specified time.
· Schedules can be set to automatically repeat at various intervals.
· Schedules can be set for random starting, if desired.
&UHDWLQJ6FKHGXOHV
1.            +  [#] + [6] [4]
(Master Code)
 (-7%61)(
6)%(= 83 %61
2.Enter a 2-digit...

Page 36

– 36 –
6FKHGXOLQJFRQWLQXHG
5. For event number “02,” enter the access group
number. Otherwise, this prompt is skipped.
Press [*] to continue to the “Start” prompt below.+6394 291&)6
<
6. For event numbers “03-07,” enter the partition
number to be armed or disarmed.
0 = arm all; 1 = partition 1; 2 = partition 2;
3 = arm common
Otherwise, this prompt is skipped.
Press [*] to continue to the “Start” prompt.4%68-8-32
<
7. Enter the event’s start time and days of week.
Hour = 00-12; minute = 00-59
AM = 0;...

Page 37

– 37 –
(YHQW/RJJLQJ3URFHGXUHV
$ERXW(YHQW/RJJLQJ
The system records various events in a history log, which can be viewed by the master
user using a Custom English Display touchpad.
· The Event Log holds up to 100 events.
· Events are displayed in chronological order, from most recent to oldest.
· When the log is full, the oldest event is replaced by the logging of any new event.
9LHZLQJWKH(YHQW/RJ
1.            + [#] +    6  +   0 
(Master Code)
(-7%61)(
6)%(= 83 %61
2. The system displays the most...

Page 38

– 38 –
(YHQW/RJJLQJ3URFHGXUHVFRQWLQXHG
7DEOHRI(YHQW/RJ&RGHV
The following table lists the codes that may appear when viewing the Event Log.
If the event code is preceded by an “E” (as in the example display on the previous
page), it means that the event is new and ongoing; if preceded by an “R,” it means the
event has been restored.
Code Definition
110 Fire Alarm
121 Duress
122 Alarm, 24-hour Silent
123 Alarm, 24-hour Audible
131 Alarm, Perimeter
132 Alarm, Interior
134 Alarm, Entry/Exit
135...

Page 39

– 39 –
7HVWLQJWKH6\VWHP7R%H&RQGXFWHG:HHNO\
$ERXW7HVWLQJWKH6\VWHP
Using TEST mode allows each protection point to be checked for proper operation.
·The touchpad sounds a single beep every 40 seconds as a reminder that the
system is in the Test mode.
·Alarm messages are not sent to your Customer Care Center while Test mode is on.
1  Disarm the system and close all protected windows,
doors, etc. The READY indicator light should come
on if all zones are intact (i.e., all protected windows,
doors,...

Page 40

– 40 –
7HVWLQJWKH6\VWHP7R%H&RQGXFWHG:HHNO\
6. Test all smoke detectors, following the manufacturers instructions. The
identification of each detector should appear on the display when each is activated.
If a problem is experienced with any protection point (no confirming sounds, no
display), call for service immediately.
When all protection points have been checked and are intact (closed), there should
be no zone identification numbers displayed on the touchpad.
7. Exit test mode:...
Start reading ADT Security Services Safewatch Pro 3000 Entrepreneur 3000 User Manual

Related Manuals for ADT Security Services Safewatch Pro 3000 Entrepreneur 3000 User Manual

All ADT Security Services manuals