Home > Addonics Technologies > Multi-Bay Enclosure > Addonics Technologies Storage Rack Rackmount Chassis srda User Manual

Addonics Technologies Storage Rack Rackmount Chassis srda User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Addonics Technologies Storage Rack Rackmount Chassis srda User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 299 Addonics Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Technical Support
    If you need any assistance to get your unit functioning properly, please have your 
    product information ready and contact Addonics Technical Support at:
    Hours: 8:30 am - 6:00 pm PST
    Phone: 408-453-6212
    Email: http://www.addonics.com/support/query/
    v5.1.11
    T E C H N O L O G I E S
    www.addonics.com
    www.addonics.com
    Phone:   408-573-8580
    Fax:     408-573-8588
    Email:   http://www.addonics.com/sales/query/
    CONTACT US
    User Guide
    Storage Rack
    (SRDAP46SL / SRDAP46RSL)
    Storage Rack DA with Port Multiplier Using Multilane 
    Connection
    Note: The Port Multiplier will only work with Port Multiplier aware multilane \
    host 
    controllers. It is compatible with multilane host controllers using the \
    Silicon Image 
    Chip SiI3124 & SiI3132.
    When the port multiplier (PM) is connected to the multilane host contr\
    oller with 
    SiI3124 or SiI3132 chip, in the RAID BIOS of the host controller, you will only see 
    one drive and that is the drive connected to SATA port 1 on the Port Multiplier.
    All SATA drives connected to the PM will show in the SATARAID5 Array Manager.
    Refer to the SATARAID5 Management Utility User Guide V1.6 for RAID 
    implementation
    http://www.addonics.com/support/user_guides/host_controller/SATARAID5-UserGuid
    e_v1.60.pdf
    Connecting the Power Cable and RAID Rack to the  
    Computer
    a.  Connect the power cord provided from the wall outlet to the back of the \
    rack.
    b.  Make sure the power is off (power LED light should be off).
    c.  Connect the infiniband cable from the back of the rack to the multilane \
     
      connector on the computer.                   
    						
    							110
    www.addonics.comTechnical Support (M-F 8:30am - 6:00pm PST)    Phone: 408-453-6212  Email: www.addonics.com/support/query/
    Power Supply
    ATX Power Supply
    This power supply provides 430W of 
    power. Before turning on the main 
    switch located on the front panel of 
    the storage rack, turn on the power 
    switch of the power supply.
    Redundant Power Supply
    This power supply includes two 
    modules within it, each of which is 
    capable of powering the entire 
    system by itself. If for some reason 
    there is a failure in one of the 
    modules, the other one will 
    seamlessly take over to prevent the 
    loss of power to the PC. You can 
    replace the damaged unit without 
    powering the machine down. This is 
    called hot swapping.
    Power LED for Power Supply: 
    Green Light: When the main power switch located on the front of the storage rack is 
    turned on, the power LED will light up.
    Red Light: When one of the module power switch is off or the module failed, the 
    LED emits a red light and the buzzer will sound.
    Module Power Switch: Each module has its own switch. 
    Module Power LED: By default, it emits a green light when the module power 
    switch is on. If the module power switch is turned off, the power LED for the power 
    supply emits a red light.
    Buzzer Reset Button: If one of the power modules fail or if the module power 
    switch is turned off, the buzzer will sound. To reset the buzzer, click on the buzzer 
    reset button.
    Replacing a failed power module:
    1.  Loosen the screw that secures the module to the power unit.
    2.  Firmly hold the handle of the module and pull it away from the power sup\
    ply. 
    POWER
    RESET
    Buzzer
    POWER TEMP
    FA N
    HDD
    I
    OPower Switch
    System Reset
    Buzzer Reset
    LED Display
    I
    OI
    O
    Punch out for port multipliers/bridges
    FansPunch out for USIB connectors
    Front
    Back
    Power Switch: This is the switch to power on devices connected to the power 
    supply. The power LED will light up to indicate power is supplied.
    Note: The main power switch located at the back of the enclosure must be turne\
    d 
    on first. 
    Reset Button: Not operational. 
    Buzzer Reset: Pressing the button stops the buzzer from making a sound. The 
    buzzer will make a sound when temperature inside the storage rack exceed\
    s the 
    temperature setting on the Thermal Management card. 
    Power LED: Lights up when the power switch is turned on.
    Temp LED: Lights up when temperature setting inside the storage rack exceeds 
    the setting on the thermal card.
    Fan LED: Normally on when fan is operational. If an abnormal condition is 
    detected, the LED flashes.
    HDD LED: Not operational.
    Power Supply
    Punch out for USIB connectors
    Punch out for eSATA
    I
    OPower Switch
    Fan
    I
    OI
    O
    Fans
    Power
    SwitchModule
    Power
    LED
    Power LED for
    Power SupplyBuzzer
    Reset
    Button
    Handle  
    						
    							92
    www.addonics.comTechnical Support (M-F 8:30am - 6:00pm PST)    Phone: 408-453-6212  Email: www.addonics.com/support/query/
    Installing Bridge Boards on Mounting Poles Inside 
    the Storage Rack
    Separate PM or HPM from bracket by unscrewing 4 screws on the PCB. Insta\
    ll 
    the PM or HPM onto the desired mounting pole.
    Installing Bridge Boards onto Back Panel
    Remove punch outs from the rear panel of the Storage Rack. Using the inc\
    luded 
    screws, attach bridge board onto the desired back panel mounting locatio\
    n.
    Connect storage devices onto the internally mounted PM or HPM, then conn\
    ect 
    the host connection onto the rear mounted bridge board.
    How to Remove the Top Cover:
    1.  Locate the 2 screws at the back of the  
      storage rack
    2.  Turn screws counterclockwise to    
     loosen.
    3.  Lift the top cover and pull towards the  
      rear end of the rack.
    To Mount Back the Top Cover:
    1.  Align the top cover with the edges of  
      the rack.
    2.  Lay it flat on the rack and slide it    
      towards the front of the rack.
    3.  Turn screws clockwise to tighten.
    How to Remove the 5 ¼” Drive 
    Cage:
    1.  Locate the 4 screws on the drive cage.
    2.  Turn screws counterclockwise to    
     loosen.
    3.  Lift the chassis up.
    Top Cover Screws
    I
    OI
    O
    I
    OI
    O
    I
    OI
    O
    I
    OI
    O
    I
    OI
    O
    Bridge Board
    PM/HPM
    SATA Device  
    						
    							38
    www.addonics.comTechnical Support (M-F 8:30am - 6:00pm PST)    Phone: 408-453-6212  Email: www.addonics.com/support/query/
    At the bottom of the drive cage, locate the metal base corresponding to \
    the storage 
    device inserted in the previous step and secure it onto the drive cage.
     
    When you finished, install the drive cage now populated with the devices\
     back 
    into the Storage Rack.
     
    How to Remove the 5 ¼” 
    Drive Bay Front Panels:
    1.  Locate the 3 screws for each  
      front panel.
    2.  Turn screws      
      counterclockwise to loosen.
    3.  Pull the front panel forward,  
      away from the drive cage.
    3 screws for each panel
    Thermal Management Card on the RAID Rack
    Features:
    Fan1 to Fan8 could be set either “ENABLE” or “DISABLE”. When\
     all the fans are set 
    on “DISABLE”, the Fan LED will have no light on.
    When Ambient temperature (or temperature inside the storage rack) is over t\
    he set 
    temperature, the LED will flash and the buzzer will sound.
    Fan Connectors
    Overheat Buzzer
    Floppy Power Connector
    Ambient Detect Terminal
    Temp. Setting
    (40°C,  50°C, 60°C)
    Fan Detect Selection
    Fan, Temperature and Power LED Connectors
    I
    OI
    O   
    						
    							74
    www.addonics.comTechnical Support (M-F 8:30am - 6:00pm PST)    Phone: 408-453-6212  Email: www.addonics.com/support/query/
    C. 3.5” Mobile Rack
    1.  Separate the ventilation front panel 
    and the metal base by removing the two 
    flat-head screws.
    2.  Attach the 3.5” drive cradle onto 
    the 3.5” to 5.25” drive bay mounting 
    bracket at the six aligned screw hole 
    locations.
     
    3.  Attach the metal base onto the 
    optical drive or other 5.25” storage device 
    using the flat head screws from the 
    ventilation front panel.
     
    With the storage device connected, slide 
    the metal base back into the drive cage. 
    Secure the storage device onto the top of 
    the drive cage using the included screws.SRNPS - Storage Rack with No Power Supply
    Connections:
    1.  Connect the 20-pin ATX connector of the power supply to the 20-pin   
      connector on the storage rack. This connection is for the power switch on  
      the storage rack.
    2.  Connect one of the 4-pin floppy power connector of the power supply to  \
      the floppy power connector on the Thermal Management card. 
    Note: The storage rack will not turn on if power is not provided to the Thermal 
    Management card.
    Installing the 4th Disk Array on the Storage Rack
    a.  Remove the back panel of the storage rack by loosening the 4 screws  
      indicated below.
    b.  Secure the bottom bracket of the    
      storage rack to the disk array using  
     screws.
    c.  Secure the top bracket of the    
      storage rack to the disk array using  
     screws.
    I
    OI
    O
    Screws
    R  
    						
    							56
    www.addonics.comTechnical Support (M-F 8:30am - 6:00pm PST)    Phone: 408-453-6212  Email: www.addonics.com/support/query/
    d.  Slide the disk array  
      into the storage rack.  
       
    e.  Secure the Disk array  
      by screwing the top  
      and bottom brackets  
      to the frame of the  
      storage rack.
    I
    OI
    OR
    Screws Screws
    Installing Storage Devices on the Storage Rack  
    A. 3.5” hard drive
    1.  Attach the 3.5” to 5.25” 
    mounting brackets onto both 
    sides of the 3.5” SATA or IDE hard 
    drive using the included screws.
     
    2.  Attach the ventilation front 
    panel and base onto one side of 
    the mounting bracket using the 
    black screws included with the 
    Storage Rack.
     
    B.  5.25” Storage devices
    1.  Separate the ventilation front 
    panel and the metal base by 
    removing the two flat-head 
    screws.
    2.  Attach the metal base onto the optical drive or other 5.25” storage d\
    evice using 
    the flat head screws from the ventilation front panel.
     
    Optical Drive