Home
>
Addonics Technologies
>
Multi-Bay Enclosure
>
Addonics Technologies Storage Rack Rackmount Chassis SR46S4R5HM user guide
Addonics Technologies Storage Rack Rackmount Chassis SR46S4R5HM user guide
Have a look at the manual Addonics Technologies Storage Rack Rackmount Chassis SR46S4R5HM user guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 299 Addonics Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Technical Support If you need any assistance to get your unit functioning properly, please have your product information ready and contact Addonics Technical Support at: Hours: 8:30 am - 6:00 pm PST Phone: 408-453-6212 Email: http://www.addonics.com/support/query/ v8.1.11 T E C H N O L O G I E S www.addonics.com User Guide Storage Rack (SR46S4R5HM)
www.addonics.comTechnical Support (M-F 8:30am - 6:00pm PST) Phone: 408-453-6212 Email: www.addonics.com/support/query/ POWER RESET Buzzer POWER TEMP F AN HDD I OPower Switch System Reset Buzzer Reset LED Display I OI O Punch out for port multipliers/bridges FansPunch out for USIB connectors Front Back Power Switch : T his is the swit ch to power on devic es connect ed to the power supply . T he power LE D will light up to indicat e power is supplied. Not e: T he main power s witch locat ed at the back of the enclosure must be turned on f irst. Reset Button: Not operat ional. B uzzer Reset: Pressing t he button stops t he overheat buzzer f rom making a s ound. The buzzer will make a s ound when t emperat ure inside t he storage rack exceeds t he t emperat ure setting on the Thermal Management card. Note: Buzzer reset switch does not silence the port multiplier buzzer. Power LED: Lights up when t he power s witch is turned on. T emp LED: Lights up when t emperat ure setting inside the storage rack exceeds t he setting on the thermal card. F an LED: Normally on when f an is operat ional. If an abnormal condition is det ected, the LE D flas hes. HDD LED : Not operat ional. Power Supply Punch out for USIB connectors Punch out for eSATA
www.addonics.comTechnical Support (M-F 8:30am - 6:00pm PST) Phone: 408-453-6212 Email: www.addonics.com/support/query/ How to Remo ve th e T op Cover: 1. Locate the 2 screws at the back of the storage rack 2 . Turn screws counterclockwise t o loosen. 3 . Lift the t op cover and pull t owards t he rear end of the rack. To Mount Back th e T op Cover: 1. Align t he top cover with the edges of the rack. 2 . Lay it flat on the rack and slide it towards t he front of the rack. 3 . Turn screws clockwise t o tight en. How to Remo ve th e 5 ¼” Dri ve Cag e: 1. Locate the 4 screws on the drive cage. 2 . Turn screws counterclockwise t o loosen. 3 . Lift the chassis up. Top Cov er S crews I OI O I OI O I OI O I OI O
www.addonics.comTechnical Support (M-F 8:30am - 6:00pm PST) Phone: 408-453-6212 Email: www.addonics.com/support/query/ How to Remo ve th e 5 ¼ ” Dri ve Bay F ront Pan els : 1. Locate the 3 screws f or each front panel. 2 . Turn screws counterclock wise to loosen. 3 . Pull t he f ront panel f orward, away from the drive c age. 3 s c rews f or each panel Thermal Manag emen t Card on t he RAI D Rack F eatu res Fan1 to F an8 could be set eit her “E N ABL E” or “DISABL E”. W hen all the fans are set on “DISABL E”, the F an LE D will have no light on. W hen Ambient temperat ure (or temperat ure inside the storage rack) is over the set t emperat ure, the LE D will f lash and t he buzz er will sound. Fan Connectors Overheat Bu zzer F loppy P ower Connect or A mbient Detect T erminal Temp. Se tting (40 °C , 5 0°C , 6 0°C ) F an Det ect Select ion F an, T emperat ure and P ower LE D Connectors
www.addonics.comTechnical Support (M-F 8:30am - 6:00pm PST) Phone: 408-453-6212 Email: www.addonics.com/support/query/ 4x1 Hardware Port Multiplier (AD4SR5HPMU-E) LE D p in s P in 1 SAT A P ort 2 SAT A Port 3 SAT A P ort 1 SAT A Port 4 US B p ort conn ecti on to a ny USB c on tr olle r RA ID co nfig r o ta ry s witc h RA ID se ttin g b utt o n eSAT A P ort P M He alth LED e SAT A L ED US B L ED US B 5 -P in He ade r P in 1 LE D P in Assi gnm ent Rot ary S witc h LED Status Drive Activity LED: Always ON. The LED blinks when there is drive activity. PM Health: Always OFF when RAID volume is working correctly. The LED starts blinking when the RAID volume is degraded. PM Power: Always ON when power is provided to the HPM. USB Status: ON when USB port is connected. eSATA Status: ON when eSATA port is connected. USB 5-Pin Header P in Ass ign ment Instruction for Special RAID Modes BIG 2 - 2 Drives Spanned o Note: Do not connect more than 2 SATA drives to the hardware port multiplier. Doing so will hang the system when you configure the raid. o For SATA drives with different capacities, the hardware port multiplier will use the smallest drive capacity of the 2 drives connected to create the total partition size. FAST 2 - 2 Drives Striped Note: Do not connect more than 2 SATA drives to the hardware port multiplier. Doing so will hang the system when you configure the raid.
www.addonics.comTechnical Support (M-F 8:30am - 6:00pm PST) Phone: 408-453-6212 Email: www.addonics.com/support/query/ Setting RAID on the HPM 1. Attach the SATA hard drives (up to 4) to the SATA ports on the Hardware Port Multiplier (HPM) using SATA cables. It is recommended to connect drives to the SATA ports 1 to 4 successively. 2. Set the Rotary switch to the RAID mode required. 3. Push the RAID setting button with a ballpoint pen tip while the HPM i\ s turned off. 4. While holding the RAID setting button, turn on the HPM and SATA hard drives and continue to hold button for at least 5 seconds. Note: The onboard LEDs for the eSATA and USB will start blinking while holding down the raid setting button. Once the raid setting button is released, the PM Health LED will blink 4-6 times. If the PM Health LED stops blinking, the raid set is set correctly. If the PM Health LED lights up as solid green, it is a bad setup. You need to repeat setting up the raid again. Use a b allpoi nt pen tip to p re ss the RA ID S ett ing B utt on Verify RAID Setting on the HPM It is assumed that you have already connected the SATA drives and set up the raid mode when verifying the raid setting. 1. Disconnect the HPM from host. 2. Turn on the Storage Rack. 3. Hold down the RAID setting button with the tip of a ball point pen. Using the table below, verify if the LEDs are lighting up. The selected LEDs will light up. Note: Use the embedded LED’s located on the HPM board as reference 5 – PM Health 7 – USB Status 8 – eSATA Status R AID M ode LE D s B IG 2 L E D s 5 , 7 & 8 a ll OF F BIG 4 5 ON , 7 & 8 OFF FA ST 2 7 ON , 5 & 8 OFF FA ST 4 8 ON , 5 & 7 OFF SAF E FA S T 5 & 7 ON , 8 O FF SAF E 2 5 & 8 ON , 7 O FF RAID 3 + S 7 & 8 ON , 5 O FF RAID 5 + S 5, 7 & 8 a ll ON
www.addonics.comTechnical Support (M-F 8:30am - 6:00pm PST) Phone: 408-453-6212 Email: www.addonics.com/support/query/ Installing th e 4th Disk Array on t he S to rag e Rack a . Remove t he back panel of the storage rack by loosening t he 4 screws indicated below . b . Secure t he bottom bracket of the storage rack to the disk array using screws. c . Secure t he top bracket of the storage rack to the disk array using screws. I OI O S crews R d. Slide t he disk array into the storage rack.
www.addonics.comTechnical Support (M-F 8:30am - 6:00pm PST) Phone: 408-453-6212 Email: www.addonics.com/support/query/ e. Secure t he Disk array by screwing t he top and bottom brackets to the f rame of the storage rack. I OI OR S crews S crews Installing St orag e Devi ces on t he S to rag e Rack A . 3 .5” h ard dr iv e 1 . Attach the 3.5” to 5.25” mount ing brackets onto bot h sides of t he 3.5” SATA or ID E hard drive using t he included sc rews . 2 . Attach the vent ilation front panel and base onto one side of t he mount ing bracket using the black screws included with the Storage Rack.
www.addonics.comTechnical Support (M-F 8:30am - 6:00pm PST) Phone: 408-453-6212 Email: www.addonics.com/support/query/ B. 5 .25” S to rag e d evi ces 1 . S eparat e the vent ilation front panel and the metal base by removing the two flat -head screws. 2 . Attach the met al base onto t he opt ical drive or other 5.25” storage device using t he f lat head screws f rom the vent ilation f ront panel. Opt ical Drive A ddonics Drive Cradle
www.addonics.comTechnical Support (M-F 8:30am - 6:00pm PST) Phone: 408-453-6212 Email: www.addonics.com/support/query/ C. 3 .5” Mobile Rack 1 . S eparat e the vent ilation front panel and the met al base by remov ing the two f lat -head screws. 2 . Attach the 3.5” drive cradle onto t he 3.5” to 5.25” drive bay mount ing bracket at the six aligned screw hole locat ions. 3 . Attach the met al base onto the opt ical drive or other 5.25” storage device using the flat head screws from the vent ilation f ront panel. W it h the storage device connect ed, slide t he met al base back into the drive cage. S ecure the storage device onto the top of t he drive cage using t he included screws.