Home > Addonics Technologies > Multi-Bay Enclosure > Addonics Technologies Storage Rack Rackmount Chassis SR46S4R5HM user guide

Addonics Technologies Storage Rack Rackmount Chassis SR46S4R5HM user guide

    Download as PDF Print this page Share this page

    Have a look at the manual Addonics Technologies Storage Rack Rackmount Chassis SR46S4R5HM user guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 299 Addonics Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Technical Support
    If you need any assistance to get your unit functioning properly, please have your 
    product information ready and contact Addonics Technical Support at:
    Hours: 8:30 am - 6:00 pm PST
    Phone: 408-453-6212
    Email: http://www.addonics.com/support/query/
    v8.1.11
    T E C H N O L O G I E S
    www.addonics.com
    User Guide
    Storage Rack
    (SR46S4R5HM)         
    						
    							www.addonics.comTechnical Support (M-F 8:30am - 6:00pm PST)    Phone: 408-453-6212  Email: www.addonics.com/support/query/
    POWER
    RESET
    Buzzer
    POWER TEMP
    F AN
    HDD
    I
    OPower Switch
    System Reset
    Buzzer Reset
    LED Display
    I
    OI
    O
    Punch out for port multipliers/bridges
    FansPunch out for USIB connectors
    Front
    Back
    Power Switch : T his  is the  swit ch to power  on devic es connect ed to the  power 
    supply . T he  power  LE D  will  light  up to indicat e power  is supplied.
    Not e: T he  main  power s witch  locat ed at the  back  of the  enclosure  must be turned 
    on f irst. 
    Reset  Button:  Not  operat ional. 
    B uzzer  Reset:  Pressing t he button  stops t he overheat  buzzer f rom  making  a s ound.
    The buzzer  will make  a s ound  when t emperat ure inside t he storage  rack exceeds t he 
    t emperat ure setting  on the Thermal  Management  card.
    Note: Buzzer reset switch does not silence the port multiplier buzzer. 
    Power LED:  Lights up  when t he power s witch  is turned  on.
    T emp LED:  Lights up  when t emperat ure setting  inside the storage  rack exceeds 
    t he  setting  on the thermal  card.
    F an LED:  Normally  on when f an is  operat ional. If an  abnormal condition is  
    det ected, the  LE D  flas hes.
    HDD LED : Not  operat ional.
    Power Supply
    Punch out for USIB connectors
    Punch out for eSATA 
    						
    							www.addonics.comTechnical Support (M-F 8:30am - 6:00pm PST)    Phone: 408-453-6212  Email: www.addonics.com/support/query/
    How  to  Remo ve th e T op  Cover:
    1.  Locate the  2 screws  at the  back  of the   
      storage  rack
    2 .  Turn  screws  counterclockwise t o    
      loosen.
    3 .  Lift the t op cover  and pull t owards t he  
      rear end of the  rack.
    To  Mount  Back  th e T op  Cover:
    1.  Align t he top cover  with the  edges  of  
      the  rack.
    2 .  Lay it flat  on the rack  and slide  it     
      towards t he front  of the  rack.
    3 .  Turn  screws  clockwise t o tight en.
    How  to  Remo ve th e 5  ¼” Dri ve 
    Cag e:
    1.  Locate the  4 screws  on the drive  cage.
    2 .  Turn  screws  counterclockwise t o    
      loosen.
    3 .  Lift the  chassis  up.
    Top  Cov er S crews
    I
    OI
    O
    I
    OI
    O
    I
    OI
    O
    I
    OI
    O 
    						
    							www.addonics.comTechnical Support (M-F 8:30am - 6:00pm PST)    Phone: 408-453-6212  Email: www.addonics.com/support/query/
    How  to  Remo ve th e 5  ¼ ” 
    Dri ve  Bay F ront  Pan els :
    1.  Locate the  3 screws f or each   
      front  panel.
    2 .  Turn  screws      
      counterclock wise to loosen.
    3 .  Pull t he f ront  panel f orward,   
      away from the drive c age.
    3 s c rews f or each  panel
    Thermal  Manag emen t Card on t he RAI D Rack
    F eatu res
    Fan1  to  F an8  could  be set eit her  “E N ABL E” or  “DISABL E”. W hen  all the  fans  are set 
    on  “DISABL E”, the F an LE D  will  have no  light  on.
    W hen  Ambient  temperat ure (or temperat ure inside  the  storage  rack) is over  the  set 
    t emperat ure, the LE D  will f lash  and t he buzz er will  sound.
    Fan  Connectors
    Overheat Bu zzer
    F loppy P ower Connect or
    A mbient  Detect T erminal
    Temp. Se tting
    (40 °C , 5 0°C , 6 0°C )
    F an  Det ect Select ion
    F
    an,  T emperat ure and P ower LE D  Connectors 
    						
    							www.addonics.comTechnical Support (M-F 8:30am - 6:00pm PST)    Phone: 408-453-6212  Email: www.addonics.com/support/query/
    4x1 Hardware Port Multiplier (AD4SR5HPMU-E)
     
     
     
     
     
                            
     
       
     
     
     
     
    LE D p in s P in  1 
    SAT A 
    P ort  2 SAT A Port  3 
    SAT A 
    P ort  1 
    SAT A Port  4 
    US B p ort  conn ecti on   
    to  a ny USB c on tr olle r RA ID  co nfig  r o ta ry  s witc h 
    RA ID  se ttin g b utt o n  eSAT A P ort 
    P M  He alth  LED  
    e SAT A L ED  
    US B L ED  
    US B 5 -P in  He ade r P in  1 
    LE D P in Assi gnm ent 
    Rot ary  S witc h 
    LED Status
    Drive Activity LED: Always ON. The LED blinks when there is drive activity.
    PM Health: Always OFF when RAID volume is working correctly. The LED starts 
                       blinking when the RAID volume is degraded.
    PM Power: Always ON when power is provided to the HPM.
    USB Status: ON when USB port is connected.
    eSATA Status: ON when eSATA port is connected.
     
     
     
     
     
     
     
     
     
     
    USB  5-Pin  Header  P in  Ass ign ment 
    Instruction for Special RAID Modes
    BIG 2 - 2 Drives Spanned
    o  Note: Do not connect more than 2 SATA drives to the hardware port 
      multiplier. Doing so will hang the system when you configure the raid.
    o  For SATA drives with different capacities, the hardware port multiplier will 
      use the smallest drive capacity of the 2 drives connected to create the total 
      partition size.
    FAST 2 - 2 Drives Striped
    Note: Do not connect more than 2 SATA drives to the hardware port multiplier. 
    Doing so will hang the system when you configure the raid. 
    						
    							www.addonics.comTechnical Support (M-F 8:30am - 6:00pm PST)    Phone: 408-453-6212  Email: www.addonics.com/support/query/
    Setting RAID on the HPM
    1. Attach the SATA hard drives (up to 4) to the SATA ports on the Hardware 
        Port Multiplier (HPM) using SATA cables. It is recommended to connect 
        drives to the SATA ports 1 to 4 successively.
    2. Set the Rotary switch to the RAID mode required.
    3. Push the RAID setting button with a ballpoint pen tip while the HPM i\
    s turned 
       off.
    4. While holding the RAID setting button, turn on the HPM and SATA hard drives 
        and continue to hold button for at least 5 seconds.
    Note:   The onboard LEDs for the eSATA and USB will start blinking while 
      holding down the raid setting button. Once the raid setting button is
      released, the PM Health LED will blink 4-6 times. If the PM Health LED 
      stops blinking, the raid set is set correctly. If the PM Health LED lights 
      up as solid green, it is a bad setup. You need to repeat setting up the 
      raid again.
                                          
     
    Use a b allpoi nt  pen  
    tip  to p re ss  the  
    RA ID  S ett ing B utt on
      
    Verify RAID Setting on the HPM
    It is assumed that you have already connected the SATA drives and set up the 
    raid mode when verifying the raid setting.
      1. Disconnect the HPM from host.
      2. Turn on the Storage Rack.
      3. Hold down the RAID setting button with the tip of a ball point pen. 
          Using the table below, verify if the LEDs are lighting up. The selected 
          LEDs will light up.
    Note: Use the embedded LED’s located on the HPM board as reference
    5 – PM Health
    7 – USB Status
    8 – eSATA Status
    R AID  M ode   LE D s 
    B IG  2 L E D s 5 ,  7 &  8  a ll OF F BIG  4 5  ON ,   7  &  8  OFF FA ST  2 7 ON ,   5  &  8  OFF FA ST  4 8 ON ,   5  &  7  OFF SAF E FA S T 5 &  7  ON ,  8  O FF SAF E 2 5  &  8  ON ,  7  O FF RAID  3  +  S 7 &  8  ON ,  5  O FF RAID  5  +  S 5,  7 &  8  a ll ON  
    						
    							www.addonics.comTechnical Support (M-F 8:30am - 6:00pm PST)    Phone: 408-453-6212  Email: www.addonics.com/support/query/
    Installing th e 4th  Disk  Array on t he S to rag e Rack
    a .  Remove t he back  panel  of the  storage  rack by loosening t he 4 screws   
      indicated below .
    b .  Secure t he bottom  bracket  of the    
      storage  rack to the  disk  array  using   
      screws.
    c .  Secure t he top bracket  of the    
      storage  rack to the  disk  array  using   
      screws.
    I
    OI
    O
    S crews
    R
    d.  Slide t he disk array   
      into the  storage  rack.  
        
    						
    							www.addonics.comTechnical Support (M-F 8:30am - 6:00pm PST)    Phone: 408-453-6212  Email: www.addonics.com/support/query/
    e.  Secure t he Disk  array   
      by screwing t he top  
      and bottom  brackets   
      to  the f rame  of the   
      storage rack.
    I
    OI
    OR
    S crews
    S
    crews
    Installing St orag e Devi ces on t he S to rag e Rack 
     
    A
    . 3 .5” h ard dr iv e
    1 .   Attach  the  3.5”  to   5.25” 
    mount ing brackets  onto  bot h 
    sides  of t he  3.5”  SATA  or  ID E hard 
    drive  using t he included  sc rews .
     
    2 .   Attach  the  vent ilation  front  
    panel  and base  onto one  side  of 
    t he  mount ing bracket  using  the 
    black  screws  included  with  the 
    Storage  Rack.
      
    						
    							www.addonics.comTechnical Support (M-F 8:30am - 6:00pm PST)    Phone: 408-453-6212  Email: www.addonics.com/support/query/
    B.  5 .25” S to rag e d evi ces
    1 .  S eparat e the  vent ilation  front  
    panel  and the  metal base  by 
    removing  the  two  flat -head 
    screws.
    2 .  Attach  the  met al base  onto t he  opt ical  drive  or other  5.25”  storage  device  using 
    t he f lat head  screws f rom the vent ilation f ront  panel.
     
    Opt ical  Drive
    A ddonics  Drive  Cradle 
    						
    							www.addonics.comTechnical Support (M-F 8:30am - 6:00pm PST)    Phone: 408-453-6212  Email: www.addonics.com/support/query/
    C. 3 .5”  Mobile  Rack
    1 .   S eparat e the  vent ilation  front  panel 
    and  the  met al base  by remov ing the  two 
    f lat -head  screws.
    2 .  Attach  the  3.5”  drive  cradle  onto 
    t he  3.5”  to   5.25”  drive  bay mount ing 
    bracket  at  the  six  aligned  screw hole 
    locat ions.
     
    3 .  Attach  the  met al base  onto the 
    opt ical  drive  or other  5.25”  storage  device 
    using  the  flat  head  screws  from  the 
    vent ilation f ront  panel.
     
    W it h  the  storage  device connect ed, slide 
    t he  met al base  back into the  drive  cage. 
    S ecure  the  storage  device onto the  top  of 
    t he  drive  cage  using t he included  screws. 
    						