Home > ADDER > Extender > ADDER ePower Switch 8 Master Manual

ADDER ePower Switch 8 Master Manual

    Download as PDF Print this page Share this page

    Have a look at the manual ADDER ePower Switch 8 Master Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 78 ADDER manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							 
    3.3.8.3. S
     
    Up to 32 t
    to the eP
    o
     
    Only 16 
    t
    monitor te
    digital inp
     
    You can c
    already c
    o
     
    To conne
    c
     
    1. Set th
    e
    sensor 
        - Do N
    O
        - Do NO
     
    2. Using 
    ePowe
     
    To config
     
    1. Open 
    y
    (ex. htt
     
    2. Enter t
    h
     
    3. Click o
    n
     
     
    Settings / P
    emperature, 
    owerSwitch 8
    temperature
    emperature
    put like the D
    onnect a sen
    onnected to t
    ct a sensor 
    e dip switche
    already insta
    OT connect t
    OT use the s
    a standard 
    rSwitch*8X
    M
    ure the sens
    you browser 
    p://192.168.
    1
    he administra
    n the Setting
    Peripherals 
       
    temperature
    8XM to monit
    e and IR p
     change a
    n
    DIM module
    nsor to the R
    he ePowerS
    to the ePo
    w
    es of the se
    alled (see us
    the xBus ca
    same addres
    RJ45 netwo
    M or behind a
    sor, use foll
    and log in to
    100.200/sysa
    ator name an
    gs and then o
    - Analog in
    e and humid
    tor environme
    roximity se
    nd detect pr
    e (see § 3.3.8
    RJ45 connect
    witch 8XM (D
    werSwitch 8X
    ensor so tha
    sers guide of
    able before s
    ss for two d
    ork cable, c
    another xBus
    lowing Log 
    o the Adminis
    admin.htm).
    nd password
    on the Periph
    nputs 
       
    ity, temperat
    ental conditio
    ensors can 
    resence of a
    8.4.2). 
    tor on the eP
    Daisy Chain 
    XM, use foll
    at the select
    f the corresp
    setting its D
    ifferent sen
    connect the 
    s peripheral a
    in procedur
    strators Conf
    d (default for 
    herals Tab. 
    ture and am
    ons.  
    be attach
    e
    a target. Th
    PowerSwitch
    Connection)
    lowing proc
    ed I/O addr
    ponding sens
    DIP switches
    sors 
    sensor to 
    t
    already conn
    re: 
    figuration Pa
    both = admi
     
        
    bient light se
    ed to the e
    he IR proxim
    h*8XM or beh
    ). 
    cedure: 
    ess does n
    o
    sor). 
    s 
    the RJ45 x
    nected to the
    age, 
    n). The hom
    ensors can b
    PowerSwitc
    mity sensor
    hind an xBus
    ot conflict w
    Bus connec
     ePowerSwit
    e page appe
    30
    be attached 
    ch 8XM to 
    r acts as a 
    s peripheral 
    ith another 
    ctor on the 
    tch 8XM. 
    ears.  
    						
    							31  If the sen
    displayed 
    and Info s
    y
    The Perip
    periphera
    Explorer o
     
    Problem 
    /
    y If you 
    8XM, 
    will b
    e
    setting
    conne
    y The 
    P
    TAB a
    Firefox
     
    4. To co
    n
    Periphe
    temper
     
     
     
    sor is prope
    on this page
    ymbol is red.
    pheral page
    al TAB agai
    or Mozilla F
    / Troublesho
    choose any
    a conflict oc
    e changed to
    gs to solve t
    cted sensors
    Peripheral pag
    again (or pus
    x). 
    nfigure or m
    erals page. A
    rature and hu
    erly connecte
    e after a dela
    . 
    e is not aut
    n (or push
    irefox). 
    ooting 
    y setting tha
    curs and th
    e
    o black. In th
    the address 
    s will now ap
    ge is not aut
    sh [F5] or pre
    modify the se
    A new page 
    umidity (TH) 
    ed to the eP
    ay of up to 60
    tomatically 
     [F5] or p
    r
    t is already 
    e correspond
    at case, disc
    conflict and
    ppear on the 
    tomatically re
    ess  on you
    nother senso
    d Info symbo
    r last connec
    the sensor 
    page and th
    e
    you need to
    keyboard if y
    ck on the c
    o set all the 
    ient light (T
    A
     
     
    l be automa
    the colour of 
    ed to refre
    ur keyboard
    or connected
    ol of the prev
    cted sensor, 
    again. If th
    e
    eir Edit and I
    o refresh it by
    you use Inter
    correspondin
    parameters 
    A) sensors. 
    atically recog
    the correspo
    sh it by cl
    d if you us
    d to the ePo
    vious connec
    change the 
    e conflict is 
    Info Symbol 
    y clicking the
    rnet Explorer
    ng Edit but
    of the tempe
    gnized and 
    onding Edit 
    icking the 
    se Internet 
    owerSwitch 
    cted sensor 
    DIP switch 
    solved, all 
    will be red. 
    e peripheral 
    r or Mozilla 
    tton in the 
    erature (T),  
    						
    							   
    Sensor I
    D
    The ePow
    • T  
    f
    • TH f
    • TA f
     
    Sensor N
    a
    In this fiel
    character
    s
     
    Analog In
    Name: 
    In this fiel
    d
    Unit: 
    In this fiel
    d
    Graph: 
    Check thi
    s
    Period (m
    In this field
     
    LOGOUT
    :
    Click Logo
    DISCARD
    Click Dis
    c
    APPLY CH
    Click App
     
    D: 
    erSwitch 8X
    followed by a
    followed by a
    followed by a
    ame: 
    d, enter th
    e
    s long, and ca
    puts 
    d enter the na
    d enter the u
    s box if you w
    minutes): 
    d enter the pe
    : 
    out at the bo
     CHANGES
    card Change
    HANGES: 
    ply Changes
    M automatic
    a number bet
    a number bet
    a number bet
    e name you 
    an contain a
    ame you wa
    nit of measu
    want a displa
    eriod betwee
    ottom of the 
    : 
    es at the bot
     at the botto
     
    cally creates 
    tween 1 and 
    tween 1 and 
    tween 1 and 
    want to giv
    e
    lphanumeric
    nt to give to 
    rement you 
    w
    ay of the ana
    en two meas
    page to exit 
    ttom of the pa
    m of the pag
    an ID Code t
    32 identifies
    32 identifies
    32 identifies
    e to the sele
    c characters.
    the analog i
    n
    want to be d
    log inputs. 
    surements. 
    the session 
    age to discar
    ge to save ch
     
    to clearly ide
    s each tempe
    s each humid
    s each ambie
    ected senso
    nputs. 
    isplayed (°C
    without savi
    rd all the cha
    hanges. 
    entify each co
    erature senso
    dity sensor, 
    ent light sens
    or. The name
    , %RH, Lux)
    ng changes.
    anges you ha
    onnected sen
    or, 
    sor. 
    e can be fro
    ). 
     
    ave made on
    32
    nsor. 
    om 1 to 32 
    n this page.  
    						
    							33 
    3.3.8.4. Settings / Peripherals - Digital Inputs  
     
    Up to 16 x Digital Input Modules, Push Buttons or Temperature and Proximity sensors can be attached to 
    the ePowerSwitch 8XM to monitor environmental conditions.  
     
    You can connect them the RJ45 connector on the ePowerSwitch 8XM or behind an xBus peripheral 
    already connected to the ePowerSwitch 8XM (Daisy Chain Connection). 
     
    An I/O Extension Module is also available to connect 8 dry contact inputs and 4 relay outputs to 
    the ePowerSwitch 8XM (ref. I/O EXT MOD). 
     
     
    3.3.8.4.1. Digital Input Modules 
     
     
     
    Up to 16 Digital Input Modules with 16 inputs for dry contacts (door contacts, smoke and water 
    detectors…) can be attached to the ePowerSwitch 8XM to monitor environmental conditions.  
     
    To connect a Digital Input Module to the ePowerSwitch 8XM, use following procedure:
     
     
    1.  Set the dip switches on the bottom of the case so that the selected I/O address does not conflict with 
    another Digital Input Module already installed (see users guide of the Digital Input Module). 
     
        - Do NOT connect the xBus cable and the Power adapter(s) before setting its DIP switches 
        - Do NOT use the same address for two different Digital Input Modules 
     
    2.  Using a standard RJ45 network cable, connect the Digital Input Module to the RJ45 xBus connector on 
    the ePowerSwitch 8XM or behind another xBus peripheral already connected to the 
    ePowerSwitch*8XM. 
     
    3.  Connect the power adapter(s) to your Digital Input Module. 
     
     
    To configure the Digital Input Module, use following Log in procedure:
     
     
    1.  Open you browser and log in to the Administrators Configuration Page, 
    (ex. http://192.168.100.200/sysadmin.htm
    ). 
     
    2.  Enter the administrator name and password (default for both = admin). The home page appears. 
     
    3.  Click on the Settings and then on the Peripherals Tab. 
     
    If the Digital Input Module is properly connected to the ePowerSwitch 8XM it will be automatically 
    recognized and displayed on this page after a delay of up to 60 seconds. In this case, the colour of the 
    corresponding Edit and Info symbol is red. 
     
    The Peripheral page is not automatically refreshed, so you need to refresh it by clicking the 
    peripheral TAB again (or push [F5] or press  on your keyboard if you use Internet 
    Explorer or Mozilla Firefox). 
      
     
     
      
    						
    							   
    Problem 
    /
    y If you 
    ePow
    e
    conne
    Digita
    l
    addres
    on the
    y The P
    TAB a
    Firefox
     
    To config
    u
    Peripheral
    A new pag
     
     
    ID: 
    The ePo
    w
    Module. 
    • DIM 
    f
    • PW f
    • DI  f
     
     
     
    / Troublesho
    choose any
    erSwitch 8XM
    cted Digital 
    l Input Mod
    ss conflict an
    e Peripherals
    Peripheral pag
    again (or pus
    x). 
    ure or modify
    s page. 
    ge appears, a
    werSwitch 8X
    followed by a
    followed by “A
    followed by a
    ooting 
    y setting tha
    XM, a conflic
    Input Modul
    e
    ule, remove
    nd reconnect
    s page and th
    ge is not aut
    sh [F5] or pre
    fy the setting
    allowing you 
    XM automatic
    a number bet
    A” or “B” ide
    a number bet
    at is already 
    t occurs an
    d
    e will be cha
    e its power 
    t it again. If t
    heir Edit and 
    tomatically re
    ess  on your k
    gital inputs, 
    e parameters
    an ID Code
    16 identifie
    s
    r supply inpu
    16 identifies
    another Digi
    sponding Edi
    ck. In that ca
    change the 
    s solved, all 
    l will be red.
    you need t
    o
    keyboard if y
    click on the 
    s of the Digita
     
     to clearly i
    d
    s each Digita
    ut A and B of
    s each digital
    tal Input Mo
    it and Info s
    ase, disconne
    DIP switch
    connected d
    o refresh it by
    you use Inter
    correspondi
    al Inputs. 
    dentify each 
    al Input Modu
    f each Digita
    l input of the
    odule connec
    symbol of th
    ect your last 
    h settings to
    devices will n
    y clicking the
    rnet Explorer
    ing Edit bu
    connected D
    ule 
    l Input Mod
    u
     module 
    34
    cted to the 
    he previous 
    tconnected 
    o solve the 
    now appear 
    e peripheral 
    r or Mozilla 
    utton in the 
    Digital Input 
    ule  
    						
    							35  Name: 
    In this field, enter the name you want to give to the Digital Input Module. The name can be from 1 to 32 
    characters long, and can contain alphanumeric characters. 
     
    Power Supplies: 
    In this field, enter the name you want to give to the two power supplies “PWA” and “PWB”. The name can 
    be from 1 to 32 characters long, and can contain alphanumeric characters. 
     
    Digital Inputs 
    Name: 
    In this fields, enter the name you want to give to each Digital Input. The name can be from 1 to 32 
    characters long, and can contain alphanumeric characters. 
     
    LOGOUT: 
    Click Logout at the bottom of the page to exit the session without saving changes. 
    DISCARD CHANGES: 
    Click Discard Changes at the bottom of the page to discard all the changes you have made on this page. 
    APPLY CHANGES: 
    Click Apply Changes at the bottom of the page to save changes. 
      
    						
    							 
    36 3.3.8.4.2. Temperature and proximity sensors 
     
     
     
    Up to 16 temperature and proximity sensors can be attached to the ePowerSwitch*8XM to monitor 
    temperature change and detect presence of a target 
     
    The IR proximity sensor acts as a digital input like the Digital Input Module or the Push Button.  
     
    You can connect a sensor to the RJ45 connector on the ePowerSwitch 8XM or behind an xBus peripheral 
    already connected to the ePowerSwitch 8XM (Daisy Chain Connection). 
     
    To connect a sensor to the ePowerSwitch 8XM, use following procedure:
     
     
    1.  Set the dip switches of the sensor so that the selected I/O address does not conflict with another 
    sensor already installed (see users guide of the corresponding sensor). 
     
        - Do NOT connect the xBus cable before setting its DIP switches. 
        - Do NOT use the same address for two different sensors. 
     
    2.  Using a standard RJ45 network cable, connect the sensor to the RJ45 xBus connector on the 
    ePowerSwitch*8XM or behind another xBus peripheral already connected to the ePowerSwitch 8XM. 
     
     
    To configure the sensor, use following Log in procedure:
     
     
    1.  Open you browser and log in to the Administrators Configuration Page, 
    (ex. http://192.168.100.200/sysadmin.htm
    ). 
     
    2.  Enter the administrator name and password (default for both = admin). The home page appears. 
     
    3.  Click on the Settings and then on the Peripherals Tab. 
     
    If the sensor is properly connected to the ePowerSwitch 8XM it will be automatically recognized and 
    displayed on this page after a delay of up to 60 seconds. In this case, the colour of the corresponding Edit 
    and Info symbol is red. 
    The Peripheral page is not automatically refreshed, so you need to refresh it by clicking the 
    peripheral TAB again (or push [F5] or press  on your keyboard if you use Internet 
    Explorer or Mozilla Firefox). 
     
    Problem / Troubleshooting 
    y If you choose any setting that is already in use by another sensor connected to the ePowerSwitch 
    8XM, a conflict occurs and the corresponding Edit and Info symbol of the previous connected sensor 
    will be changed to black. In that case, disconnect your last connected sensor, change the DIP switch 
    settings to solve the address conflict and reconnect the sensor again. If the conflict is solved, all 
    connected sensors will now appear on the Peripherals page and their Edit and Info Symbol will be red. 
    y The Peripheral page is not automatically refreshed, so you need to refresh it by clicking the peripheral 
    TAB again (or push [F5] or press  on your keyboard if you use Internet Explorer or Mozilla 
    Firefox). 
     
     
     
      
    						
    							 
    37  To config
    u
    page. A n
    sensors. 
     
     
    Sensor I
    D
    The ePow
    • TP foll
    o
     
    The ePo
    w
     
    Sensor N
    a
    In this fiel
    character
    s
     
    Analog In
    Name: 
    In this fiel
    d
    Unit: 
    In this fiel
    d
    Graph: 
    Check thi
    s
    Period (m
    In this field
     
    Digital In
    p
    Name: 
    In this fiel
    d
     
    LOGOUT
    :
    Click Logo
    DISCARD
    Click Dis
    c
    APPLY CH
    Click App
     
    ure or modify
    ew page ap
    D: 
    erSwitch 8X
    owed by a nu
    werSwitch 8X
    ame: 
    d, enter th
    e
    s long, and ca
    puts 
    d enter the na
    d enter the u
    s box if you w
    minutes): 
    d enter the pe
    puts 
    d enter the na
    : 
    out at the bo
     CHANGES
    card Change
    HANGES: 
    ply Changes
    y the settings
    ppears, allow
    M automatic
    umber betwe
    XM supports
    e name you 
    an contain a
    ame you wa
    nit of measu
    want a displa
    eriod betwee
    ame you wa
    ottom of the 
    : 
    es at the bot
     at the botto
     
    s of a sensor
    wing you to s
    cally creates 
    een 1 and 16
    s a total of u
    want to give
    lphanumeric
    nt to give to 
    rement you 
    w
    ay of the ana
    en two meas
    nt to give to 
    page to exit 
    ttom of the pa
    m of the pag
    r, click on the
    set all the pa
    an ID Code t
    6 identifies ea
    up to 16 tem
    e to the sele
    c characters.
    the analog i
    n
    want to be d
    log inputs. 
    surements. 
    the digital in
    the session 
    age to discar
    ge to save ch
    e correspond
    arameters of
     
    to clearly ide
    ach proximity
    mperature an
    ected senso
    nputs. 
    isplayed (°C
    put. 
    without savi
    rd all the cha
    hanges. 
    ding Edit bu
    f the temper
    entify each co
    y sensor. 
    nd proximity
    or. The name
    ). 
    ng changes.
    anges you ha
    utton in the P
    rature & pro
    onnected sen
    y sensors. 
    e can be fro
     
    ave made on
    Peripherals 
    ximity (TP) 
    nsor. 
    om 1 to 32 
    n this page.  
    						
    							 
    38 3.3.8.4.3. Push Button  
     
     
     
    Up to 16 Push buttons can be attached to the ePowerSwitch 8XM to trigger manually pre-programmed 
    actions.  
     
    You can connect a Push Button to the RJ45 connector on the ePowerSwitch*8XM or behind an xBus 
    peripheral already connected to the ePowerSwitch 8XM (Daisy Chain Connection). 
     
    To connect a Push button to the ePowerSwitch 8XM, use following procedure:
     
     
    1.  Set the dip switches of the Push button so that the selected I/O address does not conflict with another 
    Push button or another Digital Input Module already installed (see users guide of the Push button). 
     
        - Do NOT connect the xBus cable before setting its DIP switches. 
        - Do NOT use the same address for two different Push buttons. 
     
    2.  Using a standard RJ45 network cable, connect the Push button to the RJ45 xBus connector on the 
    ePowerSwitch 8XM or behind another xBus peripheral already connected to the ePowerSwitch 8XM. 
     
     
    To configure the Push button, use following Log in procedure:
     
     
    1.  Open you browser and log in to the Administrators Configuration Page,  
    (ex. http://192.168.100.200/sysadmin.htm
    ). 
     
    2.  Enter the administrator name and password (default for both = admin). The home page appears. 
     
    3.  Click on the Settings and then on the Peripherals Tab. 
     
    If the Push button is properly connected to the ePowerSwitch 8XM it will be automatically recognized and 
    displayed on this page after a delay of 1 to 60 seconds. In this case, the colour of the corresponding Edit 
    and Info symbol is red. 
     
    The Peripheral page is not automatically refreshed, so you need to refresh it by clicking the 
    peripheral TAB again (or push [F5] or press  on your keyboard if you use Internet 
    Explorer or Mozilla Firefox). 
     
    Problem / Troubleshooting 
    y If you choose any setting that is already in use by another Push button or another Digital Input Module 
    connected to the ePowerSwitch 8XM, a conflict occurs and the corresponding Edit and Info symbol of 
    a previous connected Push button or Digital Input Module will be changed to black. In that case, 
    disconnect your last connected Push button, change the DIP switch settings to solve the address 
    conflict and reconnect the Push button again. If the conflict is solved, all connected devices will now 
    appear on the Peripherals page and their Edit and Info Symbol will be red. 
    y The Peripheral page is not automatically refreshed, so you need to refresh it by clicking the peripheral 
    TAB again (or push [F5] or press  on your keyboard if you use Internet Explorer or Mozilla 
    Firefox). 
     
     
     
     
      
    						
    							39  To config
    u
    Peripheral
    Buttons. 
     
     
    ID: 
    The ePow
    • PB  
    f
    • SP1 i
    • LP2 i
     
    Name: 
    In this fiel
    d
    characters
     
    Digital In
    p
    Name: 
    In these fi
    e
     
    LOGOUT
    :
    Click Logo
    DISCARD
    Click Dis
    c
    APPLY CH
    Click App
     
    ure or modif
    s page. A n
    erSwitch 8X
    followed by a
    dentifies eac
    dentifies eac
    d, enter the n
    s long, and ca
    puts 
    elds enter the
    : 
    out at the bo
     CHANGES
    card Change
    HANGES: 
    ply Changes
    fy the setting
    new page ap
    M automatic
    a number bet
    ch Short Pus
    ch Long Pus
    name you wa
    an contain a
    e name of th
    ottom of the 
    : 
    es at the bot
     at the botto
     
    gs of the Pu
    ppears, allow
    cally creates 
    tween 1 and 
    sh action (d
    sh action (du
    ant to give to
    lphanumeri
    c
    he two type o
    page to exit 
    ttom of the pa
    m of the pag
    ush Button, c
    wing you to 
    an ID Code 
    t
    16 identifies
    uring less th
    uring more th
     the selected
    c characters.
    of action (Sho
    the session
    age to discar
    ge to save ch
    click on the 
    set all the 
    p
     
    to clearly ide
    s each Push 
    han 1 second
    han 3 second
    d Push butto
    ort Push or L
    without savi
    rd all the cha
    hanges. 
    correspondi
    parameters o
    entify each P
    button 
    d) 
    ds) 
    n. The nam
    e
    Long Push). 
    ng changes.
    anges you ha
    ing Edit bu
    of the conne
    ush button. 
    e can be from
     
    ave made on
    utton in the 
    ected Push 
    m 1 to 32 
    n this page.  
    						
    All ADDER manuals Comments (0)

    Related Manuals for ADDER ePower Switch 8 Master Manual