ADDER ePower Switch 8 Master Manual
Have a look at the manual ADDER ePower Switch 8 Master Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 78 ADDER manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
3.3.8.3. S Up to 32 t to the eP o Only 16 t monitor te digital inp You can c already c o To conne c 1. Set th e sensor - Do N O - Do NO 2. Using ePowe To config 1. Open y (ex. htt 2. Enter t h 3. Click o n Settings / P emperature, owerSwitch 8 temperature emperature put like the D onnect a sen onnected to t ct a sensor e dip switche already insta OT connect t OT use the s a standard rSwitch*8X M ure the sens you browser p://192.168. 1 he administra n the Setting Peripherals temperature 8XM to monit e and IR p change a n DIM module nsor to the R he ePowerS to the ePo w es of the se alled (see us the xBus ca same addres RJ45 netwo M or behind a sor, use foll and log in to 100.200/sysa ator name an gs and then o - Analog in e and humid tor environme roximity se nd detect pr e (see § 3.3.8 RJ45 connect witch 8XM (D werSwitch 8X ensor so tha sers guide of able before s ss for two d ork cable, c another xBus lowing Log o the Adminis admin.htm). nd password on the Periph nputs ity, temperat ental conditio ensors can resence of a 8.4.2). tor on the eP Daisy Chain XM, use foll at the select f the corresp setting its D ifferent sen connect the s peripheral a in procedur strators Conf d (default for herals Tab. ture and am ons. be attach e a target. Th PowerSwitch Connection) lowing proc ed I/O addr ponding sens DIP switches sors sensor to t already conn re: figuration Pa both = admi bient light se ed to the e he IR proxim h*8XM or beh ). cedure: ess does n o sor). s the RJ45 x nected to the age, n). The hom ensors can b PowerSwitc mity sensor hind an xBus ot conflict w Bus connec ePowerSwit e page appe 30 be attached ch 8XM to r acts as a s peripheral ith another ctor on the tch 8XM. ears.
31 If the sen displayed and Info s y The Perip periphera Explorer o Problem / y If you 8XM, will b e setting conne y The P TAB a Firefox 4. To co n Periphe temper sor is prope on this page ymbol is red. pheral page al TAB agai or Mozilla F / Troublesho choose any a conflict oc e changed to gs to solve t cted sensors Peripheral pag again (or pus x). nfigure or m erals page. A rature and hu erly connecte e after a dela . e is not aut n (or push irefox). ooting y setting tha curs and th e o black. In th the address s will now ap ge is not aut sh [F5] or pre modify the se A new page umidity (TH) ed to the eP ay of up to 60 tomatically [F5] or p r t is already e correspond at case, disc conflict and ppear on the tomatically re ess on you nother senso d Info symbo r last connec the sensor page and th e you need to keyboard if y ck on the c o set all the ient light (T A l be automa the colour of ed to refre ur keyboard or connected ol of the prev cted sensor, again. If th e eir Edit and I o refresh it by you use Inter correspondin parameters A) sensors. atically recog the correspo sh it by cl d if you us d to the ePo vious connec change the e conflict is Info Symbol y clicking the rnet Explorer ng Edit but of the tempe gnized and onding Edit icking the se Internet owerSwitch cted sensor DIP switch solved, all will be red. e peripheral r or Mozilla tton in the erature (T),
Sensor I D The ePow • T f • TH f • TA f Sensor N a In this fiel character s Analog In Name: In this fiel d Unit: In this fiel d Graph: Check thi s Period (m In this field LOGOUT : Click Logo DISCARD Click Dis c APPLY CH Click App D: erSwitch 8X followed by a followed by a followed by a ame: d, enter th e s long, and ca puts d enter the na d enter the u s box if you w minutes): d enter the pe : out at the bo CHANGES card Change HANGES: ply Changes M automatic a number bet a number bet a number bet e name you an contain a ame you wa nit of measu want a displa eriod betwee ottom of the : es at the bot at the botto cally creates tween 1 and tween 1 and tween 1 and want to giv e lphanumeric nt to give to rement you w ay of the ana en two meas page to exit ttom of the pa m of the pag an ID Code t 32 identifies 32 identifies 32 identifies e to the sele c characters. the analog i n want to be d log inputs. surements. the session age to discar ge to save ch to clearly ide s each tempe s each humid s each ambie ected senso nputs. isplayed (°C without savi rd all the cha hanges. entify each co erature senso dity sensor, ent light sens or. The name , %RH, Lux) ng changes. anges you ha onnected sen or, sor. e can be fro ). ave made on 32 nsor. om 1 to 32 n this page.
33 3.3.8.4. Settings / Peripherals - Digital Inputs Up to 16 x Digital Input Modules, Push Buttons or Temperature and Proximity sensors can be attached to the ePowerSwitch 8XM to monitor environmental conditions. You can connect them the RJ45 connector on the ePowerSwitch 8XM or behind an xBus peripheral already connected to the ePowerSwitch 8XM (Daisy Chain Connection). An I/O Extension Module is also available to connect 8 dry contact inputs and 4 relay outputs to the ePowerSwitch 8XM (ref. I/O EXT MOD). 3.3.8.4.1. Digital Input Modules Up to 16 Digital Input Modules with 16 inputs for dry contacts (door contacts, smoke and water detectors…) can be attached to the ePowerSwitch 8XM to monitor environmental conditions. To connect a Digital Input Module to the ePowerSwitch 8XM, use following procedure: 1. Set the dip switches on the bottom of the case so that the selected I/O address does not conflict with another Digital Input Module already installed (see users guide of the Digital Input Module). - Do NOT connect the xBus cable and the Power adapter(s) before setting its DIP switches - Do NOT use the same address for two different Digital Input Modules 2. Using a standard RJ45 network cable, connect the Digital Input Module to the RJ45 xBus connector on the ePowerSwitch 8XM or behind another xBus peripheral already connected to the ePowerSwitch*8XM. 3. Connect the power adapter(s) to your Digital Input Module. To configure the Digital Input Module, use following Log in procedure: 1. Open you browser and log in to the Administrators Configuration Page, (ex. http://192.168.100.200/sysadmin.htm ). 2. Enter the administrator name and password (default for both = admin). The home page appears. 3. Click on the Settings and then on the Peripherals Tab. If the Digital Input Module is properly connected to the ePowerSwitch 8XM it will be automatically recognized and displayed on this page after a delay of up to 60 seconds. In this case, the colour of the corresponding Edit and Info symbol is red. The Peripheral page is not automatically refreshed, so you need to refresh it by clicking the peripheral TAB again (or push [F5] or press on your keyboard if you use Internet Explorer or Mozilla Firefox).
Problem / y If you ePow e conne Digita l addres on the y The P TAB a Firefox To config u Peripheral A new pag ID: The ePo w Module. • DIM f • PW f • DI f / Troublesho choose any erSwitch 8XM cted Digital l Input Mod ss conflict an e Peripherals Peripheral pag again (or pus x). ure or modify s page. ge appears, a werSwitch 8X followed by a followed by “A followed by a ooting y setting tha XM, a conflic Input Modul e ule, remove nd reconnect s page and th ge is not aut sh [F5] or pre fy the setting allowing you XM automatic a number bet A” or “B” ide a number bet at is already t occurs an d e will be cha e its power t it again. If t heir Edit and tomatically re ess on your k gital inputs, e parameters an ID Code 16 identifie s r supply inpu 16 identifies another Digi sponding Edi ck. In that ca change the s solved, all l will be red. you need t o keyboard if y click on the s of the Digita to clearly i d s each Digita ut A and B of s each digital tal Input Mo it and Info s ase, disconne DIP switch connected d o refresh it by you use Inter correspondi al Inputs. dentify each al Input Modu f each Digita l input of the odule connec symbol of th ect your last h settings to devices will n y clicking the rnet Explorer ing Edit bu connected D ule l Input Mod u module 34 cted to the he previous tconnected o solve the now appear e peripheral r or Mozilla utton in the Digital Input ule
35 Name: In this field, enter the name you want to give to the Digital Input Module. The name can be from 1 to 32 characters long, and can contain alphanumeric characters. Power Supplies: In this field, enter the name you want to give to the two power supplies “PWA” and “PWB”. The name can be from 1 to 32 characters long, and can contain alphanumeric characters. Digital Inputs Name: In this fields, enter the name you want to give to each Digital Input. The name can be from 1 to 32 characters long, and can contain alphanumeric characters. LOGOUT: Click Logout at the bottom of the page to exit the session without saving changes. DISCARD CHANGES: Click Discard Changes at the bottom of the page to discard all the changes you have made on this page. APPLY CHANGES: Click Apply Changes at the bottom of the page to save changes.
36 3.3.8.4.2. Temperature and proximity sensors Up to 16 temperature and proximity sensors can be attached to the ePowerSwitch*8XM to monitor temperature change and detect presence of a target The IR proximity sensor acts as a digital input like the Digital Input Module or the Push Button. You can connect a sensor to the RJ45 connector on the ePowerSwitch 8XM or behind an xBus peripheral already connected to the ePowerSwitch 8XM (Daisy Chain Connection). To connect a sensor to the ePowerSwitch 8XM, use following procedure: 1. Set the dip switches of the sensor so that the selected I/O address does not conflict with another sensor already installed (see users guide of the corresponding sensor). - Do NOT connect the xBus cable before setting its DIP switches. - Do NOT use the same address for two different sensors. 2. Using a standard RJ45 network cable, connect the sensor to the RJ45 xBus connector on the ePowerSwitch*8XM or behind another xBus peripheral already connected to the ePowerSwitch 8XM. To configure the sensor, use following Log in procedure: 1. Open you browser and log in to the Administrators Configuration Page, (ex. http://192.168.100.200/sysadmin.htm ). 2. Enter the administrator name and password (default for both = admin). The home page appears. 3. Click on the Settings and then on the Peripherals Tab. If the sensor is properly connected to the ePowerSwitch 8XM it will be automatically recognized and displayed on this page after a delay of up to 60 seconds. In this case, the colour of the corresponding Edit and Info symbol is red. The Peripheral page is not automatically refreshed, so you need to refresh it by clicking the peripheral TAB again (or push [F5] or press on your keyboard if you use Internet Explorer or Mozilla Firefox). Problem / Troubleshooting y If you choose any setting that is already in use by another sensor connected to the ePowerSwitch 8XM, a conflict occurs and the corresponding Edit and Info symbol of the previous connected sensor will be changed to black. In that case, disconnect your last connected sensor, change the DIP switch settings to solve the address conflict and reconnect the sensor again. If the conflict is solved, all connected sensors will now appear on the Peripherals page and their Edit and Info Symbol will be red. y The Peripheral page is not automatically refreshed, so you need to refresh it by clicking the peripheral TAB again (or push [F5] or press on your keyboard if you use Internet Explorer or Mozilla Firefox).
37 To config u page. A n sensors. Sensor I D The ePow • TP foll o The ePo w Sensor N a In this fiel character s Analog In Name: In this fiel d Unit: In this fiel d Graph: Check thi s Period (m In this field Digital In p Name: In this fiel d LOGOUT : Click Logo DISCARD Click Dis c APPLY CH Click App ure or modify ew page ap D: erSwitch 8X owed by a nu werSwitch 8X ame: d, enter th e s long, and ca puts d enter the na d enter the u s box if you w minutes): d enter the pe puts d enter the na : out at the bo CHANGES card Change HANGES: ply Changes y the settings ppears, allow M automatic umber betwe XM supports e name you an contain a ame you wa nit of measu want a displa eriod betwee ame you wa ottom of the : es at the bot at the botto s of a sensor wing you to s cally creates een 1 and 16 s a total of u want to give lphanumeric nt to give to rement you w ay of the ana en two meas nt to give to page to exit ttom of the pa m of the pag r, click on the set all the pa an ID Code t 6 identifies ea up to 16 tem e to the sele c characters. the analog i n want to be d log inputs. surements. the digital in the session age to discar ge to save ch e correspond arameters of to clearly ide ach proximity mperature an ected senso nputs. isplayed (°C put. without savi rd all the cha hanges. ding Edit bu f the temper entify each co y sensor. nd proximity or. The name ). ng changes. anges you ha utton in the P rature & pro onnected sen y sensors. e can be fro ave made on Peripherals ximity (TP) nsor. om 1 to 32 n this page.
38 3.3.8.4.3. Push Button Up to 16 Push buttons can be attached to the ePowerSwitch 8XM to trigger manually pre-programmed actions. You can connect a Push Button to the RJ45 connector on the ePowerSwitch*8XM or behind an xBus peripheral already connected to the ePowerSwitch 8XM (Daisy Chain Connection). To connect a Push button to the ePowerSwitch 8XM, use following procedure: 1. Set the dip switches of the Push button so that the selected I/O address does not conflict with another Push button or another Digital Input Module already installed (see users guide of the Push button). - Do NOT connect the xBus cable before setting its DIP switches. - Do NOT use the same address for two different Push buttons. 2. Using a standard RJ45 network cable, connect the Push button to the RJ45 xBus connector on the ePowerSwitch 8XM or behind another xBus peripheral already connected to the ePowerSwitch 8XM. To configure the Push button, use following Log in procedure: 1. Open you browser and log in to the Administrators Configuration Page, (ex. http://192.168.100.200/sysadmin.htm ). 2. Enter the administrator name and password (default for both = admin). The home page appears. 3. Click on the Settings and then on the Peripherals Tab. If the Push button is properly connected to the ePowerSwitch 8XM it will be automatically recognized and displayed on this page after a delay of 1 to 60 seconds. In this case, the colour of the corresponding Edit and Info symbol is red. The Peripheral page is not automatically refreshed, so you need to refresh it by clicking the peripheral TAB again (or push [F5] or press on your keyboard if you use Internet Explorer or Mozilla Firefox). Problem / Troubleshooting y If you choose any setting that is already in use by another Push button or another Digital Input Module connected to the ePowerSwitch 8XM, a conflict occurs and the corresponding Edit and Info symbol of a previous connected Push button or Digital Input Module will be changed to black. In that case, disconnect your last connected Push button, change the DIP switch settings to solve the address conflict and reconnect the Push button again. If the conflict is solved, all connected devices will now appear on the Peripherals page and their Edit and Info Symbol will be red. y The Peripheral page is not automatically refreshed, so you need to refresh it by clicking the peripheral TAB again (or push [F5] or press on your keyboard if you use Internet Explorer or Mozilla Firefox).
39 To config u Peripheral Buttons. ID: The ePow • PB f • SP1 i • LP2 i Name: In this fiel d characters Digital In p Name: In these fi e LOGOUT : Click Logo DISCARD Click Dis c APPLY CH Click App ure or modif s page. A n erSwitch 8X followed by a dentifies eac dentifies eac d, enter the n s long, and ca puts elds enter the : out at the bo CHANGES card Change HANGES: ply Changes fy the setting new page ap M automatic a number bet ch Short Pus ch Long Pus name you wa an contain a e name of th ottom of the : es at the bot at the botto gs of the Pu ppears, allow cally creates tween 1 and sh action (d sh action (du ant to give to lphanumeri c he two type o page to exit ttom of the pa m of the pag ush Button, c wing you to an ID Code t 16 identifies uring less th uring more th the selected c characters. of action (Sho the session age to discar ge to save ch click on the set all the p to clearly ide s each Push han 1 second han 3 second d Push butto ort Push or L without savi rd all the cha hanges. correspondi parameters o entify each P button d) ds) n. The nam e Long Push). ng changes. anges you ha ing Edit bu of the conne ush button. e can be from ave made on utton in the ected Push m 1 to 32 n this page.