    Have a look at the manual Adam Equipment PTM Drum and Wheelchair Scale GKREVL1 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 35 Adam Equipment manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							 © Adam E\buipm\fnt Company 2013
    Adam Eq\bipme\ft 
    GK INDICATOR 
    (P.N. 305669264, Revision L1, August  2013) 
    V1.21  GK-H  scales for E\brope 
    V2.29 EC Approved scale 
    V3.41  GK scale for E\brope  V4.12  GK-H scale for USA V5.41  GK  scales for USA   
    						
    							 © Adam Equipment Company 2013 
         
        Easy Reference:  
        
    Model name of the indicator: 
     
     
    Serial number of the unit: 
     
     
    Software revision number  
    (Displayed when power is first turned on): 
     
    Date of Purchase: 
     
     
    Name of the supplier and place: 
     
     
              
    						
    							 © Adam Equipment Company 2013 1 
    CONTENTS 
     
    1. INTRODUCTION ....................................... .............................................. 3 
    2. SPECIFICATIONS ..................................... ............................................. 5 
    3. INSTALLATION ...................................................................................... 7 
    3.1. UNPACKING ..................................................................................... 7 
    4. LOCATING..............................................................................................7 
    5. CONNECTION ......................................... ............................................... 8 
    6. DISPLAY ...............................................................................................11 
    6.1. SYMBOLS AND INDICATORS ............................. .......................... 11 
    7. CALIBRATION  COUNTER FOR APPROVED INDICATORS ....... ....... 12 
    8. BATTERY ............................................................................................. 14 
    9. BACKLIGHT .......................................... ............................................... 14 
    10. AUTO POWER OFF ..................................... ...................................... 14 
    11. OPERATION ...................................................................................... 15 
    11.1. ZEROING ..................................................................................... 15 
    11.2. TARING........................................................................................ 15 
    11.2.1 MANUAL TARE ........................................ .............................. 15 
    11.2.2 PRESET  TARE  (NOT  AVAILABLE  ON  GK-M  APPROVED 
    INDICATORS) ........................................ ............................................... 16
     
    11.3. WEIGHING ................................................................................... 17 
    11.4. PARTS COUNTING ..................................... ................................ 17 
    11.5. CHECK-WEIGHING ..................................................................... 20 
    11.5.1 SETTING UP WHILE WEIGHING .......................... ................ 21 
    11.5.2 SETTING UP WHILE PARTS COUNTING OR % WEIGHING 22 
    11.6. LIMITS STORING AND RECALLING ....................... ................... 22 
    11.7. PERCENT WEIGHING ................................................................. 24 
    11.8. ANIMAL (DYNAMIC) WEIGHING .......................... ...................... 27 
    11.8.1 ANIMAL WEIGHING PROCEDURE .......................... ............. 28 
    11.9. ACCUMULATED TOTAL ............................................................. 29 
    11.9.1 MANUAL ACCUMULATION ................................ ................... 29 
    11.9.2 AUTOMATIC ACCUMULATION ............................. ................ 31 
    12. RS-232 SPECIFICATION ................................................................... 32 
    12.1. INPUT COMMANDS FORMAT .............................. ...................... 38 
    13. CALIBRATION ................................................................................... 39 
    14. PARAMETER SETTINGS ................................. ................................. 40 
    14.1. CHECK WEIGHING PARAMETERS.......................... .................. 40 
    14.2. RS-232 PARAMETERS ............................................................... 43 
    14.3. INDICATOR PARAMETERS............................... ......................... 47 
    14.4. PERCENT WEIGHING AND ANIMAL WEIGHING ............... ....... 49 
    15. ERROR MESSAGES ......................................................................... 50 
    16. SERVICE PARAMETERS ................................. ................................. 52 
    16.1. ACCESS TO PARAMETERS ............................... ........................ 52  
    						
    							 © Adam Equipment Company 2013 2 
    16.2. USING “2006” TO ENTER THE SERVICE PARAMETERS ....... . 53 
    16.2.1 F1 -CALIBRATION ................................................................. 55 
    16.2.2 F2–DECIMAL POINT POSITION.......................... .................. 56 
    16.2.3 F3 – CAPACITY ..................................................................... 56 
    16.2.4 F4 –INITIAL ZERO RANGE............................. ....................... 57 
    16.2.5 F5 -RE-ZERO RANGE ........................................................... 57 
    16.2.6 F6 -SUCCESSIVE TARE................................ ........................ 58 
    16.2.7 F7 –ADC COUNTS................................................................. 58 
    16.2.8 F8 –ZERO  MODE.................................................................. 59 
    16.2.9 F9 –LOW VOLTAGE DETECTION .......................... ............... 59 
    16.2.10 F10 –CALIBRATION COUNT (GK-M ONLY)................. ......... 60 
    16.2.11 F10 –AUTO ZERO RANGE (NOT AVAILABLE ON GK-M) .... 60 
    17. REPLACEMENT PARTS AND ACCESSORIES .................. .............. 61 
    18. SERVICE INFORMATION.................................................................. 62 
    19. APPENDIX ......................................................................................... 65 
      
    						
    							 © Adam Equipment Company 2013 3 
    INTRODUCTION 
     
    ·  The  GK  indicator  provides  an  accurate,  fast  and  versatile   general 
    purpose  indicator  with  parts  counting,  percent  weig hing  and  check-
    weighing functions.  
     
    ·  The   GK   has  LEDs  to  indicate  when  a  weight  is  below  the  lo w  limit, 
    between  the  limits  or  above  the  high  limit  next  to  the  display.    These 
    can  work  in  conjunction  with  an  audible  alarm  for  c heck  weighing  as 
    well as LCD showing LO, OK and HI. 
     
    ·  The  GK  is    supplied  with  a  RS-232  bi-directional  interfac e  and  real  time 
    clock (RTC). 
     
    ·  The  GK has a sealed keypad with colour coded membrane swit ches and 
    a  large  easy  to  read  liquid  crystal  type  display  (L CD)  supplied  with  a 
    backlight.   
     
    ·  Includes  automatic  zero  tracking,  semi-automatic  &  pre-set  tare, 
    accumulation facility that allows the weight to be  stored and recalled as 
    an accumulated total. 
      ·   OIML  Approved  models,    GK-M ,    do  not  allow  pounds  units,  have 
    calibration controlled by jumpers or passcodes  and  other limitations as 
    noted in the manual.  
      
    						
    							 © Adam Equipment Company 2013 4 
      
    						
    							 © Adam Equipment Company 2013 5 
    SPECIFICATIONS 
    INPUT SECTION 
    Load Cells  Up to 4 , 350 ohm load cells 
    Minimum 87 ohms, maximum 1120 ohms 
    Connection  6 wires 2 excitation, 2 sense, 2 signal 
    Excitation  5Vdc 
    Sensitivity  0.15uv/d    (GK-M, 1.5uv/e) 
    Linearity  0.01% FS 
    Zero Range   0- 10mv 
    Signal range  0-40mv 
    ADC Sensitivity  Approximately  0.02 µv/ADC count 
    DIGITAL SECTION 
    Maximum Range  Typically 1kg – 30000kg 
    Divisions  Up to 30,000, (GK –M, 3000 or less) 
    Weigh units  kg / g / lb for Europe, Asia, Africa kg / g / lb / oz / lb:oz for USA  
    kg only for GK-M series 
    Stabilisation Time  2 Seconds typical  
    Operating  
    Temperature -10°C - 40°C 
    14°F - 104°F 
    Power supply   230 VAC 50/60 Hz   
    12V 800ma adaptor for USA verisons 
    Battery  Internal rechargeable battery   
    Calibration  Automatic External 
    Display  6 digits LCD digital displays with capacity tracker and symbols for units    
    Indicator  Housing  ABS Plastic 
    Overall  
    Dimensions  
    (wxdxh) 260 x 170 x 115mm  
    10.2” x 6.7” x 4.5”   
    Net Weight 1.8 kg / 4 lb 
    Applications  Weighing and check weighing 
    Functions  Weighing,  Check  Weighing,      Parts  countin
    g,  check-counting,  ,  Animal 
    Weighing, Accumulating memory,  
    Interface  RS-232 bi-directional interface  English, German, French, Spanish selectable text   
    For approved indicators the input specifications is  limited to 1.5 µv per division  and 
    the number of divisions is limited to 3000d. Kilogr ams only.  
    						
    							 © Adam Equipment Company 2013 6  
    						
    							 © Adam Equipment Company 2013 7 
    INSTALLATION 
    1.1.  UNPACKING  
    This indicator must be connected to a load cell pla tform and calibrated as necessary 
    to  match  the  platform  and  user  requirements.    See  S ection  15  for  set-up 
    information.  
    The users application and the technical specificati ons of the platform or load cell will 
    determine the necessary configuration.   
    LOCATING  
     
       
     
       
     
     
     
     
     
    ·  The  scales  should  not  be  placed  in  a  location  that  will 
    reduce the accuracy.  
     
    ·  Avoid  extremes  of  temperature.  Do  not  place  in  dire ct 
    sunlight or near air conditioning vents. 
     
    ·  Avoid  unsuitable  tables.  The  table  or  floor  must  be   rigid 
    and not vibrate.  
     
    ·  Avoid  unstable  power  sources.  Do  not  use  near  large  
    users  of  electricity  such  as  welding  equipment  or  l arge 
    motors. 
     
    ·  Do not place near vibrating machinery. 
     
    ·  Avoid  high  humidity  that  might  cause  condensation.  
    Avoid  direct  contact  with  water.  Do  not  spray  or 
    immerse the scales in water. 
     
    ·  Avoid air movement such as from fans or opening doo rs. 
    Do  not  place  near  open  windows  or  air-conditioning 
    vents. 
     
    ·  Keep  the  scales  clean.  Do  not  stack  material  on  the  
    scales when they are not in use. 
     
          
    						
    							 
    8                              © Adam Equipment Company 2013 
    CONNECTION  
    This indicator must be connected to a load cell pla tform and calibrated as necessary 
    to match the platform and user requirements.    
    The  GK  has  a  connector  configured  for  a  6  wire  load   cell.        Connect  the  load 
    cells/platform to the indicator as shown below.  Th e cable length should be as short 
    as possible, using a large size wire to minimise er rors due to resistance in the leads.   
     
    GK-M model must use the 6 wire connection and has c ertain limitations for wire size 
    and length. Refer to the Approval Test Certificate  for details.   
    						