Adam Equipment Eclipse Precision Balances ECLIPSEEBL User Manual
Have a look at the manual Adam Equipment Eclipse Precision Balances ECLIPSEEBL User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 35 Adam Equipment manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
© Adam Equipment Company 2015 Adam Equipment Eclipse EBL Series (EN) Série Eclipse EBL (FR) Operating Manual Notice d’utilisation For internal (‘i’) and external (‘e’) calibration models (P.N. 3.01.6.6.12482, Revision 1.00, Effective Aug 2015) Software rev.: V1.2155 & above (Force Motor Analytical Models) V2.1827 & above (Precision Load Cell Models) V6.1010 & above (Large Pan Load Cell Models) C O P Y
© Adam Equipment Company 2015 ENGLISH: P 1 - 54 FRANÇAIS: P 55 - 111 EU DECLARATION: P 112 C O P Y
EN © Adam Equipment Company 2015 1 3016612482 Rev1-Aug15 TABLE OF CONTENTS 1 KNOW YOUR BALANCE .......................................................................................................................... 2 2 PRODUCT OVERVIEW ............................................................................................................................ 3 3 PRODUCT SPECIFICATIONS ................................................................................................................. 4 4 UNPACKING THE BALANCE ................................................................................................................. 10 5 LOCATING THE BALANCE .................................................................................................................... 10 6 SETTING UP THE BALANCE ................................................................................................................ 11 6.1 ASSEMBLING THE BALANCE ...................................................................................................... 11 6.1.1 Levelling the balance ............................................................................................................... 11 6.1.2 Warm-Up Time......................................................................................................................... 11 6.1.3 Weighing .................................................................................................................................. 11 6.2 CALIBRATION ............................................................................................................................... 12 6.2.1 Manual Calibration ................................................................................................................... 12 6.2.2 Calibration using Internal Calibration mass (if fitted) ............................................................... 12 6.2.3 Calibration using External Calibration mass ............................................................................ 12 6.2.4 Automatic Calibration ............................................................................................................... 12 6.2.5 Calibration Errors ..................................................................................................................... 13 7 DISPLAY ................................................................................................................................................. 14 7.1 SYMBOLS AND TEXT ................................................................................................................... 14 8 KEYPAD .................................................................................................................................................. 15 8.1 NUMERIC ENTRY METHOD ......................................................................................................... 16 9 INPUT/OUTPUT...................................................................................................................................... 17 10 OPERATIONS ..................................................................................................................................... 18 10.1 INITIALISATION ............................................................................................................................. 18 10.2 PASSCODES ................................................................................................................................. 18 10.3 WEIGHING ..................................................................................................................................... 18 10.4 FUNCTIONS .................................................................................................................................. 21 10.4.1 Parts Counting ..................................................................................................................... 22 10.4.2 Percentage Weighing .......................................................................................................... 23 10.4.3 Check Weighing ................................................................................................................... 24 10.4.4 Animal (Dynamic) Weighing ................................................................................................ 26 10.4.5 NET/TOTAL & Accumulation Mode. .................................................................................... 29 10.4.6 Density Determination ......................................................................................................... 31 11 RS-232 INTERFACE ........................................................................................................................... 33 11.1 HARDWARE .................................................................................................................................. 33 11.2 OUTPUT FORMATS ...................................................................................................................... 33 11.2.1 SINGLE-LINE OUTPUT FORMAT ...................................................................................... 33 11.2.2 STANDARD OUTPUT FORMAT ......................................................................................... 34 11.2.3 CUSTOM OUTPUT FORMAT ............................................................................................. 34 11.3 INPUT COMMANDS USING REMOTE KEYS............................................................................... 35 11.3.1 Invalid Input Command: ....................................................................................................... 35 12 ERROR CHECKING ............................................................................................................................ 37 13 SUPERVISOR MENUS ....................................................................................................................... 38 13.1 ENABLE WEIGHING UNITS .......................................................................................................... 38 13.2 ENABLE WEIGHING MODES ....................................................................................................... 38 13.3 ENABLE SERIAL INTERFACE PARAMETERS ............................................................................ 38 13.4 FORMAT OF CUSTOM FORMS #1 and #2 .................................................................................. 39 13.5 SETUP PARAMETERS .................................................................................................................. 40 13.6 CALIBRATION SETUP .................................................................................................................. 41 13.7 PASSCODES ................................................................................................................................. 41 14 ACCESSORIES & SPARE PARTS ..................................................................................................... 43 15 SAFETY AND MAINTENANCE ........................................................................................................... 45 16 TROUBLE-SHOOTING ....................................................................................................................... 46 16.1 TROUBLE-SHOOTING GUIDE. .................................................................................................... 47 17 SERVICE INFORMATION ................................................................................................................... 49 18 BALANCE MENU STRUCTURE ......................................................................................................... 50 19 LANGUAGE TABLE ............................................................................................................................ 53 20 WARRANTY INFORMATION .............................................................................................................. 54 C O P Y
EN © Adam Equipment Company 2015 2 3016612482 Rev1-Aug15 1 KNOW YOUR BALANCE Thank you for selecting the Eclipse Balance from Adam Equipment. This Instruction Manual will familiarise you with the installation, use, general maintenance etc. of the balance, and will guide you through the various applications. It also covers accessories, trouble-shooting, after sales service information, and other important information. These balances are highly accurate precision instruments and contain sensitive mechanisms and components. They should be transported and handled with care. When in operation, be careful to place loads gently on the weighing surface and do not overload or exceed recommended maximum capacity of the instrument or damage may occur. Please read this Manual thoroughly before starting operation. If you need any clarifications, feel free to contact your supplier or Adam Equipment. C O P Y
EN © Adam Equipment Company 2015 3 3016612482 Rev1-Aug15 2 PRODUCT OVERVIEW The Eclipse balances are ideal for laboratory and general purpose weighing. They can also be used for some advanced weighing functions. FEATURES: · External menu-driven calibration. · Internal calibration (option) for outstanding accuracy without the need for manual calibration. · Large easy to read 2-line LCD display with blue backlight, 24 mm tall primary display digits, 10 mm secondary digits, and capacity tracker bar. · Easy to use, wipe-clean sealed keypad with pressureless capacitive-touch backlit buttons which work with fingers, gloves or stylus. · Force-restoration mechanism option for supreme accuracy, or alloy load cell technology option for stable yet highly accurate weighing. · Solid die-cast aluminium alloy construction with 304 grade stainless steel pan for durability and easy cleaning. · Standard applications include weighing, check weighing, percentage weighing, parts counting, dynamic (animal) weighing, accumulation (net/total), and solid and liquid density determination. · Bi-directional RS-232 interface and USB interface as standard. · Can be configured to print a GLP Compliant report after each calibration to include the time, date, balance number and a verification of the calibration. · Automatic temperature compensation. · Large range of weighing units, including customised option. · Below balance weighing facility (accessory hook required). · Mains powered. · External display option. · Display and documentation in a choice of 4 languages – English, German, French & Spanish. · Password protection. · Security locking point. C O P Y
EN © Adam Equipment Company 2015 4 3016612482 Rev1-Aug15 3 PRODUCT SPECIFICATIONS Eclipse EBL Models (Suffix e for external calibration models, Suffix i for internal calibration models) Model # EBL 104 e/i EBL 164 e/i EBL 214 e/i EBL 254 e/i EBL 314 e/i Maximum Capacity 100 g 160 g 210 g 250 g 310 g Readability (d) 0.0001 g Number of intervals n= 1000000 1600000 2100000 2500000 3100000 Min. weight 0.01 g Repeatability (Std. Dev) 0.00015 g 0.0002 g Linearity + 0.0003 g Units of Measure grams, milligrams, carats, grains, Newtons, Drams, Ounces, troy ounces, pennyweight, momme, Taiwanese Taels, Hong Kong Taels, Singapore Taels, Ticals, Tola, Custom Stabilization Time Typically 5 seconds Operating Temp 15ºC to 35ºC recommended, 40 – 60 % RH (non-condensing) Power Supply External mains power adapter - supplied as standard (Input Voltage 100–240 VAC, 50/60 Hz) Input Voltage 18 VDC - 830 mA Weighing mechanism Force Restoration Balance Motor Calibration Suffix i = internal calibration mechanism, e = external calibration only External Calibration Mass Recommended OIML class: E2, ASTM / ANSI class: 1 100 g Display LCD with blue backlight, 7 character 24 mm high main display, with symbols. Secondary information line of 10mm high alpha-numeric characters. Keypad 12 capacitive-touch backlit keys – work with fingers, gloves or stylus contact. Draft Shield (w x d x h) Sliding door Draft Shield (165 x 145 x 240 mm) Pan Size Round, 90mm diameter Overall Dimensions (w x d x h) 220 x 310 x 323 mm 8.7 x 12.2 x 12.7 in Net Weight 5.2 kg / 11 lb 9 oz (external calibration model) 5.9 kg / 13 lb 0 oz (internal calibration model) C O P Y
EN © Adam Equipment Company 2015 5 3016612482 Rev1-Aug15 Model # EBL 223 e / i EBL 423 e / i Maximum Capacity 220 g 420 g Readability (d) 0.001 g Number of intervals n= 220000 420000 Min. 0.02 g 0.02 g Repeatability (Std. Dev) 0.002 g Linearity + 0.003 g Units of Measure grams, milligrams, carats, grains, Newtons, Drams, Ounces, troy ounces, pennyweight, momme, Taiwanese Taels, Hong Kong Taels, Singapore Taels, Ticals, Tola, Custom Stabilization Time Typically 5 seconds Operating Temp 15ºC to 35ºC recommended, 40 – 60 % RH (non-condensing) Power Supply External mains power adapter - supplied as standard (Input Voltage 100–240 VAC, 50/60 Hz) Input Voltage 18 VDC - 830 mA Weighing mechanism Precision Load Cell Calibration Suffix i = internal calibration mechanism, e = external calibration only, External Calibration Mass Recommended OIML class: E2, ASTM / ANSI class: 2 100 g 200 g Display LCD with blue backlight, 7 character 24 mm high main display, with symbols. Secondary information line of 10mm high alpha-numeric characters. Keypad 12 capacitive-touch backlit keys – work with fingers, gloves or stylus contact. Draft Shield (w x d x h) Glass Ring Draft Shield With Alloy Lid (180 mm diam. x 90 mm) Pan Size Round, 120 mm diameter Overall Dimensions (w x d x h) 220 x 310 x 90 mm without breeze ring 8.7 x 12.2 x 3.5 in Net Weight 3.1 kg / 6 lb 12 oz (external calibration model) 3.7 kg / 8 lb 8 oz (internal calibration model) C O P Y
EN © Adam Equipment Company 2015 6 3016612482 Rev1-Aug15 Model # EBL 623 e / i EBL 823 e / i EBL 1023 e / i EBL 1623 e / i Maximum Capacity 620 g 820 g 1020 1620 Readability (d) 0.001 g Number of intervals n= 620000 820000 1020000 1620000 Min. weight 0.02 g 0.02 g 0.02 g 0.02 g Repeatability (Std. Dev) 0.002 g Linearity + 0.003 g Units of Measure grams, milligrams, carats, grains, Newtons, Drams, Ounces, troy ounces, pennyweight, momme, Taiwanese Taels, Hong Kong Taels, Singapore Taels, Ticals, Tola, Custom Stabilization Time Typically 5 seconds Operating Temp 15ºC to 35ºC recommended, 40 – 60 % RH (non-condensing) Power Supply External mains power adapter - supplied as standard (Input Voltage 100–240 VAC, 50/60 Hz) Input Voltage 18 VDC - 830 mA Weighing mechanism Force Restoration Balance Motor Calibration Suffix i = internal calibration mechanism, e = external calibration only External Calibration Mass Recommended OIML class: E2, ASTM / ANSI class: 2 500 g 1 kg Display LCD with blue backlight, 7 character 24 mm high main display, with symbols. Secondary information line of 10mm high alpha-numeric characters. Keypad 12 capacitive-touch backlit keys – work with fingers, gloves or stylus contact. Draft Shield (w x d x h) Glass Ring Draft Shield With Alloy Lid (180 mm diam. x 90 mm) Pan Size Round, 160 mm diameter Overall Dimensions (w x d x h) 220 x 310 x 90 mm without breeze ring 8.7 x 12.2 x 3.5 in Net Weight 4.0 kg / 8 lb 13 oz (external calibration model) 4.8 kg / 10 lb 9 oz (internal calibration model) C O P Y
EN © Adam Equipment Company 2015 7 3016612482 Rev1-Aug15 Model # EBL 1602 e / i EBL 2602 e / i EBL 3602 e / i EBL 4602 e / i EBL 6202 e / i Maximum Capacity 1600 g 2600 g 3600 g 4600 g 6200 g Readability (d) 0.01 g 0.01 g 0.01 g 0.01 g 0.01 g Number of intervals n= 160000 260000 360000 460000 620000 Min. weight 0.2 g 0.2 g 0.2 g 0.2 g 0.2 g Repeatability (Std. Dev) 0.02 g Linearity + 0.03 g Units of Measure grams, milligrams, carats, grains, Newtons, Drams, Ounces, troy ounces, pennyweight, momme, Taiwanese Taels, Hong Kong Taels, Singapore Taels, Ticals, Tola, Custom Stabilization Time Typically 5 seconds Operating Temp 15ºC to 35ºC recommended, 40 – 60 % RH (non-condensing) Power Supply External mains power adapter - supplied as standard (Input Voltage 100–240 VAC, 50/60 Hz) Input Voltage 18 VDC - 830 mA Weighing mechanism Precision Load Cell Calibration Suffix i = internal calibration mechanism, e = external calibration only External Calibration Mass Recommended OIML class: F1, ASTM / ANSI class: 3 500 g 1 kg 2 kg Display LCD with blue backlight, 7 character 24 mm high main display, with symbols. Secondary information line of 10mm high alpha-numeric characters. Keypad 12 capacitive-touch backlit keys – work with fingers, gloves or stylus contact. Draft Shield (w x d x h) None Pan Size Round, 160 mm diameter Overall Dimensions (w x d x h) 220 x 310 x 90 mm 8.7 x 12.2 x 3.5 in Net Weight 3.1 kg / 6 lb 14 oz (external calibration model) 3.9 kg / 8 lb 10 oz (internal calibration model) C O P Y
EN © Adam Equipment Company 2015 8 3016612482 Rev1-Aug15 Model # EBL 4201e EBL 6201e EBL 8201e Maximum Capacity 4200 g 6200 g 8200 g Readability (d) 0.1 g 0.1 g 0.1 g Number of intervals n= 42000 62000 82000 Min. weight 2 g 2 g 2 g Repeatability (Std. Dev) 0.2 g Linearity + 0.3 g Units of Measure grams, milligrams, carats, grains, Newtons, Drams, Ounces, troy ounces, pennyweight, momme, Taiwanese Taels, Hong Kong Taels, Singapore Taels, Ticals, Tola, Custom Stabilization Time Typically 5 seconds Operating Temp 15ºC to 35ºC recommended, 40 – 60 % RH (non-condensing) Power Supply External mains power adapter - supplied as standard (Input Voltage 100–240 VAC, 50/60 Hz) Input Voltage 18 VDC - 830 mA Weighing mechanism Precision Load Cell Calibration External calibration only External Calibration Mass Recommended OIML class: F2, ASTM / ANSI class: 4 2 kg Display LCD with blue backlight, 7 character 24 mm high main display, with symbols. Secondary information line of 10mm high alpha-numeric characters. Keypad 12 capacitive-touch backlit keys – work with fingers, gloves or stylus contact. Draft Shield (w x d x h) None Pan Size Round, 160 mm diameter Overall Dimensions (w x d x h) 220 x 310 x 90 mm 8.7 x 12.2 x 3.5 in Net Weight 3.1 kg / 6 lb 14 oz C O P Y