Page 31
31 | P a g e © Adam Equipment Company 2009 Place the calibration weight on the scale. Press th e [Total / ] key to show the ADC values for this weight. “ LoAd ” “ 10 ” “ 345689 ” Press the [Total / ] key to show the ADC values for this weight. The display will then show: “ SPAN ” “ PASS ” “ ” After few seconds it will show the next function. “ F5 ” “ ACCES ” “ CAL ” Remove the...
Page 32
32 | P a g e © Adam Equipment Company 2009 “ Pin 1 ” “ ” “ ” Enter the new access code “ Pin 1 ” “ - - - -” “ ” press the [Total/ ] key to confirm and store the value, The scale will ask you to repeat the number again for securit y. “ Pin 2 ” “ ” “ ” Enter the new access code “ Pin 2 ” “ - - - -” “ ” Press [CE /Esc] to escape without changes...
Page 33
33 | P a g e © Adam Equipment Company 2009 6.0 SECURE PARAMETERS 6.1 SETTING UP SECURED PARAMETERS The following parameters can only be accessed when the service access code 9999 is used. Turn the scale on while holding the [Total/ ] key down and then release the key. Key in the Service Access Code as described in sect ion 5.1.1. The first function shown is F1, the Baud Rate Setting. “ F1 ” “ bAud ” “ SEt ” This procedure gives access to...
Page 34
34 | P a g e © Adam Equipment Company 2009 6.1.1 F6 - SETTING ASCII VALUE FOR PRINTED LEGENDS Press the [MC/ ] key to scroll through the parameters. To change the symbol that is printed to represent t he value of the money used, follow this procedure. When the display is showing: “ F6 ” “ SIGN ” “ SEt ” Press the [Total/ ] key and the display will show: “ F6 ” “ 52H ” “ SEt ” Current symbol used in...
Page 35
35 | P a g e © Adam Equipment Company 2009 Press [CE /Esc] to escape without changes before it is stored or press the [Total / ] key to confirm and store the value. Currenc Symbo Value Rand R 52 Dollar $ 24 Other values for a particular symbol can be found i n a table of ASCII values. A sample table is attached.
Page 36
36 | P a g e © Adam Equipment Company 2009 6.1.2 F7 - Denomination Values The denomination keys for South Africa have values pre-assigned, from 1c to R5 (0.05 to 5.00). Plus the 2 token keys can be re assigned also. In total 11 keys can be used for denominations or tokens. This procedure will allow you to change the denomination values associated with e ach key. It may be necessary to change keypad designs for other denomi nations. ...
Page 37
37 | P a g e © Adam Equipment Company 2009 “ F7 ” “ K01 ” “ 1.00 ” Where the K01 is the key number for the key being u sed. The display also shows the denomination currently selec ted. “ F7 ” “ K08 ” “ 0.10 ” For example the number 8 key has a value of 0.10. To enter a new value for this key position simple u se the numeric keys and press [Total/ ] to save the new value. To set a key...
Page 38
38 | P a g e © Adam Equipment Company 2009 “ F8” “ LinEr” “ SEt ” The linearity of the scale is set by calibrating w ith 2 masses, 1/2capacity (10kg) and full capacity (20kg). Press the [Total/ ] key to enter this function. The display will show the following: “ CAL ” “ 0.000 ” “ 12345 ” The number in the TOTAL window is the number of int ernal counts representing the zero weight, from the anal og to digital converter...
Page 39
39 | P a g e © Adam Equipment Company 2009 6.1.4 F9- Factory Calibration Value This calibration is stored in a separate location f rom the user calibration (F4). If a scale has been disrupted it is possible to rec all this calibration in order to have a scale that has the original calibration rest ored. This calibration can be done at any time without ch ecking for being within 10% of the previous factory calibrations. This val ue will also overwrite...
Page 40
40 | P a g e © Adam Equipment Company 2009 Place the weight on the scale. When the scale is st able Press the [Total / ] key. The display will then show: “ SPAN ” “ PASS ” “ ” The scale will return to the Function menu. Press [CE /Esc] to return to normal operation or [MC/ ] to select a different function.