Adam Equipment AELP Pallet Beams GCREVC6 User Manual
Here you can view all the pages of manual Adam Equipment AELP Pallet Beams GCREVC6 User Manual. The Adam Equipment manuals for Pallet Beam are available online for free. You can easily download all the documents as PDF.
Page 11
P a g e 9 © Adam Equipment Company 2010 5.0 DISPLAYS The scales have three sections. These are “Weight”, “Unit Weight” and “Count”. The LCD design is: WEIGHT UNIT WEIGHT COUNT 5.1 WEIGHT DISPLAY It has 6-digit display to indicate the weight on th e scale. Net Weight Display, Net Stability indicator, symbol Zero indicator, 0 symbol The weighing unit: kg, lb
Page 12
P a g e 10 © Adam Equipment Company 2010 5.2 UNIT WEIGHT DISPLAY This display will show the unit weight of a sample. This value is either input by the user or computed by the scale. The unit of meas urement is grams if grams if kilograms is selected for the weighing unit, or pou nds if pounds is selected. 5.3 COUNT DISPLAY This display will show the number of items on the s cale or the value of the accumulated count. See the next section...
Page 13
P a g e 11 © Adam Equipment Company 2010 6.0 OPERATION NOTE: GC-a Scales only SETTING THE WEIGHING UNIT, lb or kg The scale will turn on displaying the last weighing unit selected, either kilograms or pounds. To change the weighing unit press the [U. Wt./Units] key when the “Unit Weight” display shows zero. If necessary press the [CE] key to clear the unit weight before changing. 6.1 ZEROING THE DISPLAY You can press the [Zero]...
Page 14
P a g e 12 © Adam Equipment Company 2010 6.2.1 Preset Tare The user can enter a preset tare value if the displ ay is at zero or gross weight. Enter the value for preset tare using the keypad, then press the [Tare] key to set the preset zero value. If the display was at zero the weight will show a n egative value equal to the preset tare value entered and the “ Net” indicator will be on. If a weight was on the platform then the...
Page 15
P a g e 13 © Adam Equipment Company 2010 If the scale is not stable, the calculation will no t be completed. If the weight is below zero, the “Count” display will show negative count. B. Entering a known Unit Weight If the unit weight is already known then it is poss ible to enter that value using the keypad. Enter the value of the unit weight in grams, using the numeric keys followed by pressing the [U. Wt./Units] key. The "Unit...
Page 16
P a g e 14 © Adam Equipment Company 2010 6.3.4 Manually Accumulated Totals The values (weight and count) shown on the display can be added to the values in the memory by pressing the [M+] key. The "Weight" display will show the total weight, the "Count" display will show the total accumulated count and the "Unit Weight" display shows the number of times, the items have been added to the m emory...
Page 17
P a g e 15 © Adam Equipment Company 2010 7.0 USER PARAMETERS The parameters are set to customise the scale to suit the weighing applications. You need to enter a secure menu by entering a password when requested. Press [Tare] once, during the initial counting of the display a fter the power is turned on. The “Weight” display will show PIn requesting for the password number. The default password is 0000 but other numbers...
Page 18
P a g e 16 © Adam Equipment Company 2010 7.1 SETTING OF PIN Display will show “F2” “Pin”. This parameter allows setting of a new password number. The default password is “0000”. Press [Tare] . The “Weight” display will show Pin 1. Enter the new password number. The “Unit Weight” display will show dashes. Press [Tare]. The “Weight” display will change to Pin 2 , Enter the password again and press [Tare]. The...
Page 19
P a g e 17 © Adam Equipment Company 2010 8.0 CALIBRATION The GC scales are calibrated using metric weights a nd GCa scales are calibrated using metric or pound weights depending on the unit in use before calibration. See the Service parameters sec tion for more information. The scale will display a value of the weight to be used for calibration, this value is the last weight used for calibration. You can...
Page 20
P a g e 18 © Adam Equipment Company 2010 9.0 RS-232 INTERFACE The GC Series are supplied with a RS-232 bi-directional interface. The scale when connected to a printer or computer through the RS-2 32 interface, outputs the weight, unit weight and count. Specifications: Connector: The scale can be set to print text in English, Fren ch, German or Spanish. See the RS- 232 parameters section for details. All lines end with...