Page 11

 P a g e 9                     © Adam Equipment Company 2010 
 
5.0  DISPLAYS 
The scales have three sections. These are “Weight”, “Unit Weight” and “Count”. 
The LCD design is:    
      WEIGHT          UNIT WEIGHT 
 
COUNT 
   
5.1  WEIGHT
 DISPLAY 
It has 6-digit display to indicate the weight on th e scale. 
Net Weight Display,  Net  
Stability indicator,     symbol                
Zero indicator,   0   symbol  
The weighing unit:    kg, lb   

Page 12

 P a g e 10                     © Adam Equipment Company 2010 
 
5.2  UNIT WEIGHT DISPLAY 
This  display  will  show  the  unit  weight  of  a  sample.   This  value  is  either  input  by 
the user or computed by the scale. The unit of meas urement is grams if grams if 
kilograms is selected for the weighing unit, or pou nds if pounds is selected. 
 
5.3  COUNT
 DISPLAY 
This  display  will  show  the  number  of  items  on  the  s cale  or  the  value  of  the 
accumulated count. See the next section...

Page 13

 P a g e 11                     © Adam Equipment Company 2010 
 
6.0  OPERATION 
NOTE: GC-a Scales only 
SETTING THE WEIGHING UNIT, lb or kg 
The  scale  will  turn  on  displaying  the  last  weighing  unit  selected,  either  kilograms  or 
pounds.    To  change  the  weighing  unit  press  the [U.  Wt./Units]  key  when  the  “Unit 
Weight” display  shows  zero. If necessary press  the  [CE]  key  to  clear  the  unit  weight 
before changing.  
6.1  ZEROING THE DISPLAY 
   You can press the   [Zero]...

Page 14

 P a g e 12                     © Adam Equipment Company 2010 
6.2.1  Preset Tare 
   The  user  can  enter  a  preset  tare  value  if  the  displ ay  is  at  zero  or  gross 
weight.  Enter the value for preset tare using the  keypad, then press the 
[Tare]  key to set the preset zero value. 
   If the display was at zero the weight will show a n egative value equal to 
the  preset  tare  value  entered  and  the  “ Net”  indicator  will  be  on.    If  a 
weight  was  on  the  platform  then  the...

Page 15

 P a g e 13                     © Adam Equipment Company 2010 
  If  the  scale  is  not  stable,  the  calculation  will  no t  be  completed.  If  the 
weight is below zero, the  “Count” display will show negative count. 
B.  Entering a known Unit Weight 
  If the unit weight is already known then it is poss ible to enter that value 
using the keypad.    
   Enter  the  value  of  the  unit  weight  in  grams,  using  the  numeric  keys 
followed by pressing the   [U.  Wt./Units] key. The "Unit...

Page 16

 P a g e 14                     © Adam Equipment Company 2010 
  
6.3.4   Manually Accumulated Totals
 
   The  values  (weight  and  count)  shown  on  the  display  can  be  added  to 
the  values  in  the  memory  by  pressing  the  [M+]  key.  The  "Weight" 
display  will  show  the  total  weight,  the  "Count" display  will  show  the 
total  accumulated  count  and  the  "Unit  Weight" display  shows  the 
number  of  times,  the  items  have  been  added  to  the  m emory...

Page 17

 P a g e 15                     © Adam Equipment Company 2010 
   
7.0  USER PARAMETERS 
The parameters are set to customise the scale to suit the weighing applications. You 
need to enter a secure menu by entering a password  when requested. 
   Press   [Tare]   once,  during  the  initial  counting  of  the  display  a fter  the 
power is turned on.    
   The  “Weight”   display  will  show  PIn            requesting  for  the  password 
number. 
   The default password is  0000 but other numbers...

Page 18

 P a g e 16                     © Adam Equipment Company 2010 
7.1  SETTING OF PIN 
   Display  will  show   “F2”  “Pin”.  This  parameter  allows  setting  of  a  new 
password number.  The default password is  “0000”.  
   Press  [Tare] . The “Weight”  display will show  Pin 1. 
   Enter  the  new  password  number.  The  “Unit  Weight”  display  will  show 
dashes. Press  [Tare]. 
   The  “Weight”   display  will  change  to  Pin  2 ,  Enter  the  password  again 
and press  [Tare]. 
   The...

Page 19

 P a g e 17                     © Adam Equipment Company 2010 
 
8.0  CALIBRATION 
  The  GC  scales  are  calibrated  using  metric  weights  a nd  GCa  scales  are 
calibrated  using  metric  or  pound  weights  depending  on  the  unit  in  use 
before  calibration.    See  the  Service  parameters  sec tion  for  more 
information. 
   The  scale  will  display  a  value  of  the  weight  to  be  used  for  calibration, 
this  value  is  the  last  weight  used  for  calibration.     You  can...

Page 20

 P a g e 18                     © Adam Equipment Company 2010 
 
9.0  RS-232 INTERFACE 
The  GC  Series  are  supplied  with  a  RS-232  bi-directional  interface.  The  scale  when 
connected  to  a  printer  or  computer  through  the  RS-2 32  interface,  outputs  the 
weight, unit weight and count.  
 Specifications: 
            
  
Connector:  
        
The scale can be set to print text in English, Fren ch, German or Spanish.  See the RS-
232 parameters section for details.  