Page 41
Chapter 3 3-7 Removing the Display Module 1. Disconnect the LED cable from the main board at CN13. 2. Remove the 2 screws of the LCD FPC cable. 3. Disconnect the LCD FPC cable from the motherboard at CN12. 4. Disconnect the internal microphone power cable on CN9 of the main board. 5. Remove the 2 screws at the base and at the back of the lower case. 6. Carefully detach the display from the main unit Removing the heat sink: 1. To detach the upper case, first remove the 2 screws from the heatsink....
Page 42
3-8 EXTENSA 700/710 Service Guide Disassembling the Upper Case Disassembly procedure of the upper case: 1. Remove the 11 screws from the upper case and base unit. 2. Disconnect the mouse cable at CN18 and the floppy drive cable at CN17. 3. Disconnect the suspend mode cable at CN7, the left channel speaker at CN8 and the right channel speaker at CN10 from the main board. TouchPad bracket disassembly procedure 1. Remove the 4 screws of the touch pad cover. 2. Detach the touch pad cover from the left...
Page 43
Chapter 3 3-9 6. To separate the left channel speaker from the upper case, release the speaker cable from it’s latch. Disassembling the CPU: 1. Remove the 7 screws on the CPU heat sink. 2. Remove the CPU heat sink. 3. Lift the MMO CPU module up and remove. 4. Disconnect the IMM CPU module at U22. 5. Disconnect the SIR-Lens assembly from the lower case.. Disassembling the fan: 1. Disconnect the fan power cable at CN23 from the main board. 2. Remove the screw of the IMM shield. 3. Lift the IMM...
Page 44
3-10 EXTENSA 700/710 Service Guide Disassembling the lower case: 1. Remove the main board from the lower case. 2. Disconnect the DC-DC charger board from the main board at CN24 and CN21. 3. Remove the IDE card from the main board at CN30. 4. Remove the 4 screws on the PCMCIA card. 5. Lift the PCMCIA card from the main board at CN16. 6. This completes the disassembly procedure of the lower case. 700SG-3.fm Page 10 Monday, June 8, 1998 11:01 AM
Page 45
Chapter 3 3-11 Disassembling the LCD: 1. Remove the 5 screws on the display bezel. 2. Pull out the LCD bezel carefully. 3. Remove the internal microphone from the display panel. 4. Remove the 2 screws located at either side of the LED board. 5. Lift off the LED board from the display. 6. Remove the 2 screws which secure the inverter board. 7. Remove the 4 screws from the LCD. 8. Detach the LCD and inverter board from the display panel. 9. Remove the inverter board by disconnecting the FPC cable...
Page 47
Chapter 4 4-1 Use the following procedure as a guide for computer problems. Note: The diagnostic tests are intended to test only Acer products. Non- Acer products, prototype cards, or modified options can give false errors and invalid system responses. 1. Obtain the failing symptoms in as much detail as possible. 2. Verify the symptoms by attempting to re-create the failure by running the diagnostic test or by repeating the same operation. Note: To run the diagnostics, refer to “Running the...
Page 48
4-2 EXTENSA 700/710 Service Guide Diskette Drive Checkout Do the following to isolate the problem to a controller, driver, or diskette. A write-enabled, diagnostic diskette is required. Note: Make sure that the diskette does not have more than one label attached to it. Multiple labels can cause damage to the drive or cause the drive to fail. Do the following to select the test device. See “Running the Diagnostics” for details. 1. Boot from the diagnostics diskette and start the PQA program (please...
Page 49
Chapter 4 4-3 2. Replace the CD-ROM drive. 3. Replace the IDE board. 4. Replace the Main board. Keyboard or Auxiliary Input Device Checkout Remove the external keyboard if the internal keyboard is to be tested. If the internal keyboard does not work or an unexpected character appears, make sure that the flexible cable extending from the keyboard is correctly seated in the connector on the sub card. If the keyboard cable connection is correct, run the Keyboard Test. See “Running the Diagnostics” for...
Page 50
4-4 EXTENSA 700/710 Service Guide Memory errors might stop system operations, show error messages on the screen, or hang the system. 1. Boot from the diagnostics diskette and start the PQA program (please refer to “Running PQA Diagnostics Program”. 2. Go to the diagnostic memory in the test items. 3. Press F2 in the test items. 4. Follow the instructions in the message window. Note: Make sure that the DIMM is fully installed into the connector. A loose connection can cause an error. 83240 32 8 40...