A&D Scale HT500GD User Manual
Have a look at the manual A&D Scale HT500GD User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 26 A&D manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
1 SAFETY PRECAUTIONS All safety messages are identified by the following, WARNING or CAUTION, of ANSI Z535.4 (American National Standard Institute: Product Safety Signs and Labels). The meanings are as follows: WARNING A potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION A potentially hazardous situation which, if not avoided, may result in minor or moderate injury. This manual is subject to change without notice at any time to improve the product. Product specifications are subject to change without any obligation on the part of the manufacture. When using the scale, the following safety precautions should always be followed. WARNING Repairs Do not disassemble the scale. Contact your local A&D dealer if your balance needs service or repair. Troubleshooting If a problem has occurred and you cannot clear it, stop using the scale, place a notice on the scale and request service from the store where you purchased the balance or from your local A&D dealer. CAUTION Conditions for use and Ambient Temperature The scale is a precision instrument. Avoid installing the scale in direct sunlight, excessive dust, high humidity, high temperature, large temperature fluctuations or magnetic fields, which may cause problems or malfunctions. Drafts and vibration may cause excessive weighing errors. Use the scale range of the -10°C to 40°C, with less than 85% R.H. Operation Avoid using the weighing pan to move the scale, as that could cause damage to the scale. Avoid overloading that could cause damage to the scale. The scale is not waterproof type. Water invading into the scale may cause damage. If the scale is not to be used for a long period of time, remove all batteries from the battery compartment to avoid battery leakage. Do not mix batteries made by different manufactures, or mix old and new batteries. Replace all of the batteries at one time. Use only the specified AC adapter for the scale (AC adapter is optional).
2 Compliance with FCC rules Please note that this equipment generates, uses and can radiate radio frequency energy. This equipment has been tested and has been found to comply with the limits of a Class A computing device pursuant to Subpart J of Part 15 of FCC rules. These rules are designed to provide reasonable protection against interference when the equipment is operated in a commercial environment. If this unit is operated in a residential area it may cause some interference and under these circumstances the user would be required to take, at his own expense, whatever measures are necessary to eliminate the interference. ( FCC = Federal Communications Commission in the U.S.A.) PARTS DESCRIPTION Battery indicator Weighing units ZERO indicator STABLE indicator NET indicator Negative sign Stainless steel weighing pan Color bar Display ON/OFF key RE-ZERO key UNITS key Weighing pan Calibration switch
3 The ON/OFF key turns the scale power on/off. The RE-ZERO key sets the display to zero or subtracts the weight of a container in the weighing mode. The RE-ZERO key selects a parameter in the preset modes. The UNITS key changes weighing units in the weighing mode. The UNITS key selects item in the preset modes. STABLE The STABLE indicator indicates when the reading is stable in the weighing mode. The STABLE indicator indicates active units in unit selection. NET The NET indicates when the net weight is displayed. ZERO The ZERO indicates when the scale zero is correct. Battery remaining level, shown after power-on only. Errors Overload. The scale zero is out of range. Low battery. Replace used batteries with four new ones immediately. Calibration error. The weighing of zero or calibration mass is out of range. PREPARATION Installing batteries St ep 1 Remove the battery cover. St ep 2 Before use, remove the insulation tape from the battery compartment. St ep 3 Insert 4 new batteries (AA size) into the battery compartment, taking extreme care of the polarities. St ep 4 Replace the battery cover. Note The batteries provided with the scale are for testing the performance of the scale and may have a limited life. St ep 2 St ep 14 new batteries Battery cover Insulation tape
4 When using the AC adapter St ep 1 Verify that the AC adapter is correct. St ep 2 Open the rubber cap and plug the AC adapter into the AC adapter jack. WEIGHING St ep 1 Turning the scale on / off Press the ON/OFF key to turn the scale on. The scale displays all segments for a few seconds and then displays zero. Press the ON/OFF key again to turn the scale off. St ep 2 Selecting the weighing unit Press the UNITS key to select the weighing unit. The scale will power up with the weighing unit that was in use when last turned off. St ep 3 Weighing Verify that the reading is zero. If not, press the RE-ZERO key to zero the display. If you use a container for weighing, place an empty container on the weighing pan and press the RE-ZERO key to zero the display. Place the objects to be weighed on the weighing pan or in the container. When the reading becomes stable, the STABLE indicator is displayed. St ep 2 AC adapter jack Rubber cap
5 FUNCTIONS Automatic Power Off Function If the scale is left ON and the STABLE indicator is displayed, the automatic power-off function turns power off after approximately 5 minutes. St ep 1 Entering the preset mode. Press the ON/OFF key while pressing the RE-ZERO key. St ep 2 Selecting the status. Press the RE-ZERO key to disable or enable this function. Automatic power off function is disabled Automatic power off function is enabled. St ep 3 Storing the status. Press the UNITS key. The scale displays and returns to the weighing mode. Storing Weighing Units Among the units, those available for the user have been set at the factory before shipping. The unit can be selected in the preset mode. Refer to the table on the page 6 for the order of the units available, while skipping the units that are not available. Select and store the weighing units as described below. It is also possible to specify the display unit that will be shown first when the scale is turned on. Either Tael (HK general, Singapore) or Tael (Taiwan) can be selected. St ep 1 Entering the preset mode. Press the ON/OFF key while pressing the UNITS key. Press the RE-ZERO key. St ep 2 Selecting units. UNITS key Select the unit. RE-ZERO key The STABLE indicator indicates when to enable the unit. Select to disable or to enable the unit. ex. or . St ep 3 Storing units. Press the UNITS key to display . Press the RE-ZERO key to return to the weighing mode.
6 Unit Unit name Conversion to gram At preset mode Gram 1 g Tola (India) 11.6638038 g Ounce (Avoir) 28.349523125 g Troy Ounce 31.1034768 g Pound (UK) 453.59237 g Tael (Taiwan) 37.5 g Ta el ( HK general, Singapore) 3 7.79 94 g Pennyweight 1.55517384 g Metric Carat 0.2 g Newton is a value calculated as follows: Newton = (weight in gram) x (9.80665 m/s2) / 1000. Selecting The Decimal Point St ep 1 Entering the preset mode. Press the ON/OFF key while pressing the UNITS key. Press the UNITS key to display the current decimal point. or . St ep 2 Selecting a decimal point. Press the RE-ZERO key to select decimal point or . St ep 3 Storing the decimal point. Press the UNITS key to display . Press the RE-ZERO key to return to the weighing mode. Setting The Stability St ep 1 Entering the preset mode. Press the ON/OFF key while pressing the UNITS key. Press the UNITS key to display the current setting. or . St ep 2 Selecting a filter. Press the RE-ZERO key to select or for the filter response. St ep 3 Storing the selected filter response. Press the UNITS key to display . Press the RE-ZERO key to return to the weighing mode.
7 CALIBRATION When is Calibration Required? Calibration may be required when the scale was initially installed or has been moved to another location. Calibration Using a Calibration Weight St ep 1 Entering the calibration mode Remove the switch cover located on the bottom of the scale. Press the ON/OFF key to turn the scale on. Press the Calibration switch while the scale is in the weighing mode. will be displayed. St ep 2 Zero calibration Press the RE-ZERO key. will be displayed. Wait for the STABLE indicator to be displayed with nothing on the weighing pan. Press the RE-ZERO key to perform zero calibration. will be displayed after a few seconds. Select next step as follows: Proceed to the span calibration of St e p 3. Press the UNITS key to return to the weighing mode without performing span calibration. St ep 3 Span calibration When is displayed, place the calibration weight on the center of the weighing pan. Wait for the STABLE indicator to be displayed. Press the RE-ZERO key to perform span calibration. will be displayed and the scale will automatically return to the weighing mode. Remove the calibration weight from the weighing pan. Note For details about the calibration weight, Refer to SPECIFICATIONS. St ep 1 Switch cove r Calibration switch
8 Calibration by Gravity Compensation If the acceleration of gravity at your location is not correct and you do not have calibration weights, the scale can be calibrated by compensating for the acceleration of gravity. Refer to The Value of Gravity at Various Locations. St ep 1 Setting a new acceleration value Press the ON/OFF key to turn the scale on. Press the Calibration switch while the scale is in the weighing mode. Press the UNITS key when is displayed. The current acceleration value will be displayed. ex. . Change the value with following keys. RE-ZERO key Increments the blinking digit. UNITS key Moves the blinking digit. St ep 2 Storing the value into the memory While pressing the UNITS key, press and hold the RE-ZERO key and release the UNITS key. After , will be displayed. Turn the scale off to finish the procedure. SPECIFICATIONS MODEL HT-500GD Weighing capacity 510 g Resolution 0.1 g Non-linearity ±0.2 g Repeatability (Std. deviation)0.1 g Span drift ±150 ppm/°C (5°C to 35°C / 41°F to 95°F) Operating temp. -10°C to 40°C / 14°F to 104°F, Less than 85%RH Display 13.5 mm / 0.53 inches, 7segment liquid crystal displayDisplay update Approximately 10 times per second Power supply 4 x R6P / LR6 / AA size batteries or AC adapter Battery life Approximately 450 hours with alkaline cells at 20°C / 68°FPan size 132 (W) x 130 (D) mm 5.2 (W) x 5.1 (D) in. Dimensions 195 (W) x 136 (D) x 44 (H) mm 7.7 (W) x 5.4 (D) x 1.7 (H) in.Approximately weight 610 g Max. Tare weight 510 g Calibration weight 500 g ±0.01 g Accessories 3 color bars, stainless steel weighing pan, this manual, 4 AA size monitor batteries Options AC adapter
9 Gravity Acceleration At Various Locations Amsterdam 9.813 m/s2 Madrid 9.800 m/s2 Athens 9.807 m/s2 Manila 9.784 m/s2 Auckland NZ 9.799 m/s2 Mexico City 9.779 m/s2 Bangkok 9.783 m/s2 New York 9.802 m/s2 Brussels 9.811 m/s2 Milan 9.806 m/s2 Buenos Aires 9.797 m/s2 Oslo 9.819 m/s2 Calcutta 9.788 m/s2 Ottawa 9.806 m/s2 Cape Town 9.796 m/s2 Paris 9.809 m/s2 Chicago 9.803 m/s2 Rio de Janeiro 9.788 m/s2 Copenhagen 9.815 m/s2 Rome 9.803 m/s2 Nicosia 9.797 m/s2 San Francisco 9.800 m/s2 Jakarta 9.781 m/s2 Singapore 9.781 m/s2 Frankfurt 9.810 m/s2 Stockholm 9.818 m/s2 Istanbul 9.808 m/s2 Sydney 9.797 m/s2 Havana 9.788 m/s2 Taipei 9.790 m/s2 Helsinki 9.819 m/s2 Tokyo 9.798 m/s2 Kuwait 9.793 m/s2 Vancouver, BC 9.809 m/s2 Lisbon 9.801 m/s2 Washington DC 9.801 m/s2 London (Greenwich) 9.812 m/s2 Wellington NZ 9.803 m/s2 Los Angeles 9.796 m/s2 Zurich 9.807 m/s2 3-23-14 Higashi-Ikebukuro, Toshima-ku, Tokyo 170-0013 JAPAN http://www.aandd.jp/ A&D Australasia Pty Ltd.32 Dew Street, Thebarton, South Australia 5031 AUSTRALIA http://www.andmercury.com.au/ A&D ENGINEERING, INC.1756 Automation Parkway, San Jose, California 95131 U.S.A. http://www.andonline.com/ A&D KOREA Limited 8th Floor, Manhattan Bldg. 36-2 Yoido-dong, Youngdeungpo-ku, Seoul, KOREA http://www.andk.co.kr/ A&D INSTRUMENTS LTD.Unit 24/26 Blacklands Way, Abingdon Business Park, Abingdon, Oxon OX14 1DY United Kingdom http://www.aandd-eu.net/ A&D RUS Co.,ltd. 121357, Российская Федерация, г.Москва, ул. Верейская, дом 17 http://www.aandd.ru