Page 31
31 OPTION Menu With the OPTION menu, the items shown in the table below can be performe\ d. Perform each operation in accordance with the instructions in the table \ below. : SELECT MENUMAIN PICTURE-1 PICTURE-2 INPUT AUTO SCREEN OPTION VOLUME SCREEN TYPE LAMP TIME FILTER TIME RESET16 4:3 1234h 21h ItemDescription VOLUMEAdjust Volume: High ñLow SCREEN TYPE Select the Screen Type:4:3 ñ16:9 ñ16:9 ñ16-9 • Please select the screen type used and the picture position in case of 1\ 6:9. This selection...
Page 32
32 Lamp The projector uses a high-pressure mercury glass lamp. The lamp can break with aloud bang, or burn out,if jolted or scratched, handled while hot, or worn over time. Note that each lamp has a different lifetime, and some may burst or burn out soon after you start using them. In addition, when the bulb bursts, it is possible for shards of glassto fly into the lamp housing, and for gas containing mercuryto escape from the projector’s vent holes. • If the lamp should break (it will make a loud bang...
Page 33
33 1Turn off the projector, and unplug the power cord. Allow the lamp bulb to cool for at least 45 minutes. 6Insert the new lamp, and tighten the 2 screws firmly to lock it in place. Slide the lamp door into place until it locks into position. Slowly turn the projector so that the top is facing up. 3After making sure that the projector has cooled adequately, slowly flip over the projector, so that the bottom is facing up. 4Unscrew the screw of the lamp door, then slide and take the lamp door up. 2Contact...
Page 34
34 Air Filter Caring For The Air Filter The air filter should be cleaned about every 100 hours. If the indicators or a message prompts you to clean the air filter (see the section “Related Messages” and “Regarding The Indicator Lamps”), clean the air filter as soon as possible. If the air filter becomes clogged by dust or the like, internal temperature rises and could cause malfunction. 1Turn off the projector, and unplug the power cord. 6Reset the filter timer. WARNING• Please carefully read the...
Page 35
35 Replacing The Air Filter Turn off the projector, and unplug the power cord. 2Contact your local dealer to prepare a new air filter. Tell the dealer your air filter type number. 4Hold the release buttons of the air filter, while pulling down it. 3After making sure that the projector has cooled adequately, remove the filter cover. Hold the release buttons of the filter cover, while pulling up it. 6Reset the filter timer. (1) Turn on the projector. While the projector running, press the MENU butto\ n...
Page 36
36 Other Care WARNING•Please carefully read the “Product Safety Guide”. • Before replacing the air filter, make sure the power switch is off and the power cable is not plugged in. ATTENTION • Do not use cleaners or chemicals other than those listed below, including benzene and paint thinner. • Do not use aerosols or sprays. • Do not polish or wipe with hard objects. Caring For The Inside Of The Projector Caring For The Lens In order to ensure the safe use of your projector, please have it cleaned and...
Page 37
37 Troubleshooting Related Messages When the units power is ON, messages such as those shown below may be d\ isplayed. When any such message is displayed on the screen, please respond as desc\ ribed below. If the same message is displayed after the treatment, or if a mes\ sage other than the following appears, please contact your dealer or service company. MessageDescription CHANGE THE LAMP AFTER REPLACING LAMP, RESET THE LAMP TIMER. (*1)Lamp usage time is approaching 2000 hours. (*2) Preparation of a...
Page 38
38Wipe the dust-detecting window by using a soft cloth. Troubleshooting (continued) Related Messages (continued) MessageDescription CLEAN THE AIR FILTER POWER OFF FIRST, THEN CLEAN THE AIR FILTER. AFTER CLEANING THE AIR FILTER, RESET THE FILTER TIMER.A note of precaution when cleaning the air filter. Please immediately turn the power OFF, and clean or change the air filter by referring to the “Air Filter” section of this manual. After you have cleaned or changed the air filter, please be sure to reset...
Page 39
39 ATTENTION• When the interior portion has become overheated, for safety purposes, the power source is automatically turned off, and the indicato\ r lamps may also be turned off. In such a case, press the “ Ó” (power OFF) side of the main power switch, and wait at least 45 minutes. After the unit has sufficiently co\ oled down, please make confirmation of the attachment state of the lamp and lamp cover, an\ d then turn the power on again. Regarding The Indicator Lamps Lighting and flashing of the...
Page 40
40 power indicatorlamp indicatortemp indicatorDescription Lighting or blinking in redTurned offBlinking in red The cooling fan is not operating. Turn the power OFF and wait at least 20 minutes. After the unit has sufficiently cooled down, please make confirmation of the following item, and then resent the power to ON. • Is there no foreign matter caught in the cooling fan? Lighting or blinking in red Turned offLighting in red There is a possibility that the interior portion has become heated. Turn the...