Home > A&D

A&D User Manuals

The manuals from this brand are divided to the category below. You can easily find what you need in a few seconds.
A&D User Manuals
                                                     
GXK-012 
Animal Weighing Bowl 
Instruction Manual 
 
 
 
Models 
 GX-K series 
 GF-K series 
 
 
 
 
 
 
 
 
Weighing  
 Setup 
1  Replace the normal weighing pan with the animal weighing bowl (GXK-012). 
 
 Measurement 
2 Press the 
 RE-ZERO   key to cancel the weight (tare). 
3  Place a sample animal in the bowl to weigh it. 
 
 
 
Caution 
  When using the animal weighing mode (Hold function), the average weight of the 
animal can be displayed. 
 When using this option, the weighing range that can...
                                            
                                                    Auto-Centering Pan (AX-MC1000PAN / MC6100PAN ) 
Instruction Manual 
 
Read this manual thoroughly before using the auto-centering pan and keep it at hand for future reference. 1.Introduction 
The auto-centering pans are used with the MC series 
Mass Comparator Balances
, the 
AX-MC1000PAN with the MC-1000 and the MC6100PAN with the MC-6100. The balance can 
achieve more precise weighing, by using the auto-centering pan, which aligns the center of 
gravity of the material being weighed (a weight) with the...
                                            
                                                     
    
Auto-Centering Pan(AX-MC10K/30KPAN) 
Instruction manual
 
Read this manual thoroughly before using the Auto-Centering Pan and keep it at hand 
for future reference. 
 1. Introduction 
The auto-centering pans are used with the MC series Mass Comparator Balances, 
the AX-MC10KPAN with the MC-10K and the AX-MC30KPAN with the MC-30K. The 
balance can achieve more precise weighing, by using the auto-centering pan, which 
aligns the center of gravity of the material to be weighed (a weight) with the pan...
                                            
                                                     
1WMPD4002999 
BMシリーズ用本体カバー 
 
 カバーは保管時にホコリや汚れ防止としてご利用してください。 
 カバーはACアダプタやその他のケーブルを接続した
状態でご利用いただけます。 
 カバーを取り外すときはカバーの端が機器に引っかか
らないようにしてださい。 
 仕様 
 材質: ナイロン 
 色: ライトグレー 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Dust Cover for BM series 
 Use the cover to protect the instrument from dust and dirt during storage. 
 It is possible to use the cover while the instrument is connected to the AC adapter and other cables. 
 When removing the cover take care so as not to get its edge caught on the instrument....
                                            
                                                     
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
WM+PD4001368 
 
F F
S S
- -
i i
   
S S
e e
r r
i i
e e
s s
   
 
C C
h h
e e
c c
k k
   
W W
e e
i i
g g
h h
i i
n n
g g
   
S S
c c
a a
l l
e e
s s
   
O O
p p
t t
i i
o o
n n
   
 
OP-02 / OP-03 / OP-04 
  
                                            
                                                    FXi-02 / HRA-02 USB Interface Instruction Manual 
1. Features 
   Connects a balance (FX-i / FZ-i series, HR-A / HR-AZ series) to a personal computer to transmit the balance 
weight data to the personal computer via USB. Applicable OS is Windows 2000 or later. 
  Because a Windows standard driver is used, complicated installation of a dedicated driver is not necessary. 
Once a connection between the balance and the personal computer is made, weight data can be 
transmitted. (Quick USB function) 
...
                                            
                                                     
  FXi-08  HRA-08 FXi-08 
 HRA-08  
Ethernet Interface
 
 
When installing this Ethernet board (
FXi-08  HRA-08
) into the A&D balances, such as 
FX-i, FZ-i, 
HR-A  HR-AZ
, the balance can communicate with a computer through the LAN port and the 
weighing data can be managed with the software "Wi n CT- Pl us".  
  
Unpacking the Ethernet Board 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Installing the Ethernet Board 
Caution:
 Remove the AC adapter from the balance while 
doing the following work. 
 
Step...
                                            
                                                     
 
 
 
 
 
 
 
  
 
 
  
 
 
 
  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1WMPD4001369A  
                                            
                                                     
1WMPD4001658 
FXi-WP-11  Large Breeze Break      
1. Features 
The FXi-WP-11 can be installed on the FX- i WP series 
balances. 
Using the FX i-WP-11 will protect the balance from the 
effects of a breeze and will provide more accurate 
weighing results. 
An anti-static treatment has been applied to the breeze 
break components, therefore the weighing error caused 
by static electricity should not be a problem. 
2. Unpacking 
 
 
 
 
 
 
* 
The FX i-WP-11 is set on top of the balance, not fastened....
                                            
                                                    GH-02 USB Interface Instruction Manual 
1. Features 
   The GH-02 USB interface connects a GH series analytical balance to a personal computer and is used to 
transmit the balance weight data to the personal computer via USB. Applicable operating system is Windows 
98 or later. 
   As the Windows standard driver is used to transmit the weight data, complicated installation of a dedicated 
driver is not necessary. 
  The personal computer recognizes the GH-02 interface much like a keyboard, and...
                                            
                                                    GX-02 USB Interface Instruction Manual 
1. Features 
   The GX-02 USB interface connects a GX or GF series multi-function balance to a personal computer and is used 
to transmit the balance weight data to the personal computer via USB. Applicable operating system is 
Windows 98 or later. 
   As the Windows standard driver is used to transmit the weight data, complicated installation of a dedicated 
driver is not necessary. 
  The personal computer recognizes the GX-02 interface much like a keyboard,...
                                            
                                                     
About the MC series balance function settings 
 
§  Factory settings have been changed for stable weighing 
The factory settings described on page 31 of the MC series instruction manual have been changed. 
 
The MC series are high resolution balances. Therefore, external disturbances such as breezes or vibrations 
may cause unstable weighing values. 
For stable weighing, the factory settings of the following functions have been changed to those more 
resistant to external disturbances, as shown below....
                                            
                                                    SCE-02    USB Interface Instruction Manual
 
 1. Features 
•   Connects a scale to a personal computer and used to transmit the scale weight data to the 
personal computer via USB. Applicable OS is Windows 98SE or later. 
•  As a standard Windows driver is used, complicated installation of a dedicated driver is not 
necessary. Once a connection between the scale and the personal computer is made, the weight 
data can be transmitted. 
•   Transmits the scale weight data to any application such as Excel,...