71 MOTIF6 / MOTIF7 / MOTIF8 Display of Test Conclusion: NG //// MOTIFx Test Program //// 26:SIMM(Full) :NG CN-19:OK CN-20:NG If any IC is found to be NG, this test determines NG. Ending Process: The test ends after displaying the conclusion and returns to the item select status. T27: ROM Check Initial Screen: //// MOTIFx Test Program //// 27:ROM :Press [ENTER] Procedure: Run the test. Check Item: Check the LCD for the test conclusion. Display of Test Conclusion: OK //// MOTIFx Test Program //// 27:ROM :OK IC-31,IC-25,IC-36 OK OK OK IC.-1,IC.-2,IC.-3,IC.-4,IC.-5,IC.-6 OK OK OK OK OK OK NG //// MOTIFx Test Program //// 27:ROM :NG IC-31,IC-25,IC-36 OK OK OK IC.-1,IC.-2,IC.-3,IC.-4,IC.-5,IC.-6 OK OK OK NG OK OK If either of the target ICs is found to be NG, this test determines NG. Ending Process: The test ends after displaying the test conclusion and enters the item selection status. T28: RAM R/W Check Initial Screen: //// MOTIFx Test Program //// 28:RAM :Press [ENTER] Procedure: Run the test. Check Item: Check the LCD for the test conclusion.Display of Test Conclusion: OK //// MOTIFx Test Program //// 28:RAM :OK IC--9, OK IC-24,IC-30,IC-35,IC-38,IC-83,IC-84 OK OK OK OK OK OK NG //// MOTIFx Test Program //// 28:RAM :NG IC--9, OK IC-24,IC-30,IC-35,IC-38,IC-83,IC-84 OK OK OK OK OK NG If either of the target ICs is found to be NG, this test determines NG. Ending Process: The test ends after displaying the test conclusion and enters the item selection status. Others: All RAM data are saved. Repeat a cycle to back up data immediately before the Verify check and restore immediately after the Verify check. T29: mLAN Check Initial Screen: //// MOTIFx Test Program //// 29:mLAN :Press [ENTER] Description: Tests signal exchanges with a mLAN board (mLAN8E) connected to mLAN I/F. For this test, instruct the mLAN board to execute the following items successively: 1. Board connection test: Check to see whether an mLAN board exists or not. 2. Entering board test mode: Instruct the mLAN board to execute the test. 3. MEL output test: Switch the sound source clock to that from mLAN and test the MEL output (4 lines) from the unit as follows: Outputs sine waves from the unit to the four lines of output successively and make sure the mLAN board receiving the output stays at the specified level. 4. MEL input test: Test the MEL input (1 line) from the mLAN board to unit as follows: (1) Outputs a sine wave from the unit to the mLAN board. (2) The mLAN board relays the signal to the MEL input of the unit. (3) The unit D/A converts the signal to output to STEREO OUT. 5. Board reset: Initializes the mLAN board.
72MOTIF6 / MOTIF7 / MOTIF8 Procedure: Hear sounds from Outputs R and L. (No sound is produced from output R.) //// MOTIFx Test Program //// 29:mLAN : Connection :OK Entering Test Mode :OK MEL Output :OK MEL Input :ON Check Item: Tests 1, 2 and 3 are automatically assessed by the mLAN board and unit, so check the test results from the LCD For test 4, make sure a sine wave sounds by the human ear. Display of Test Conclusion: OK No display NG //// MOTIFx Test Program //// 29:mLAN : Connection :xx Entering Test Mode :xx MEL Output :xx MEL Input :OFF xx : OK/NG notation Any of Connection, Entry and MEL Output Ending Process: Press [EXIT] button to end sounding, waiting for a test number. T30: Factory Set Initial Screen: //// MOTIFx Test Program //// 30:FactorySet :Press [ENTER] Description: Sets to the factory default settings. Procedure Run the test. If the test successfully completed, a sine wave momen- tarily sounds. Check Item: None. Display of Test Conclusion: //// MOTIFx Test Program //// 30:FactorySet :OK Ending Process: Displays the conclusion and exits from the test. Others: After completing Factory Set, the following data is set. System Setup: Set to the initial data contained in the attached MIDI table.Internal Voice: Set to the Factory Set Voice. Internal Performance: Set to the Factory Performance. Factory-shipped MODE, timbre, etc.: Mode is set to Voice Mode. The Voice number is set to PRE1 A01(1). T31: Exit Initial Screen: //// MOTIFx Test Program //// 31:Exit :Press [ENTER] Description: Exits from the test mode. Procedure: As the test starts, the following screen appears: //// MOTIFx Test Program //// 31:Exit :[NO] or [YES] Press [YES] button to exit the test. Press [NO] button to return to the entry screen. Check Item: None. Display of Test Conclusion: None. Ending Process: See the Procedure. Others: As exiting from the test mode, the normal power-up sequence is performed. Make sure that the ON/OFF click noise of the unit power switch conforms to the following: OUTPUT-R and L: 500mv-pp or less ASSIGNABLE OUTPUT-L/R: 500mv-pp or less PHONES-R and L: 500mv-pp or less Set the unit to the factory settings and exit from the test to enter the VOICE PLAY mode. Make sure that the noise level before activating notes conforms to the following: NoiseLevel: Measure using a level indicator (with JIS-C filter). Do not insert a Plug-in Board. OUTPUT-L -------> -91 dBm or less (loading, 10 kΩ) OUTPUT-R -------> -91 dBm or less (loading, 10 kΩ) ASSIGNABLE-L ---> -91 dBm or less (loading, 10 kΩ) ASSIGNABLE-R --->-91 dBm or less (loading, 10 kΩ) PHONES-L -------> -91 dBm or less (loading, 33 Ω) PHONES-R -------> -91 dBm or less (loading, 33 Ω)
73 MOTIF6 / MOTIF7 / MOTIF8 ERROR MESSAGES Messages Information MIDI buffer full. MIDI data error. MIDI checksum error. Bulk protected. Device number is off. Device number mismatch. Change internal battery. Disk or card full. File not found. Bad disk or card. Disk or card not ready. Disk or card unformatted. Disk or card write protected. Illegal disk or card. Illegal file. Illegal file name. Read only file. Cant make folder. Folder is too deep. Unknown file format. SCSI error. Disk or card read/write error. Cant find associated files. Folder not empty Unsupported disk Seq memory full. Choose user phrase. No data. Illegal check box. No F7 (End of Exc.) Pattern length mismatch. Phrase length mismatch Phrase number overflow Illegal input. Illegal track number. Illegal phrase number. Illegal measure. Meter mismatch Sample memory full. Too many samples. Sample is too short. Sample freq is too low. Illegal sample data. No sample data. Sample is too long. SIMM configuration error. Multi plug-in is not in slot 3. Effect plug-in is not in slot 1. Plug-in 1 communication error. Plug-in 2 communication error. Plug-in 3 communication error.Failed to process the MIDI data because too much data was received at one time. An error occurred when receiving MIDI data. An error occurred when receiving bulk data. Bulk data or a SCSI message was received when RcvBulk was set to “protect.” (See page 258.) Bulk data cannot be transmitted/received since the device number is off. Bulk data cannot be transmitted/received since the device numbers dont match. The internal backup battery has no remaining power. Replace the battery. The card or disk is full and no more data can be saved. Use a new card or disk, or make space by erasing unwanted data from the card or disk. The specified file was not found on the card or disk during a load operation. Try again after re-inserting/re-connecting the card or disk. The card or disk is unusable. Format the card or disk and try again. A card or disk is not properly inserted in or connected to the MOTIF. The card or disk is not formatted, or the format is unusable by the MOTIF. Check the card/disk contents. The card or disk is write protected, or you have attempted to write to a read-only medium such as CD-ROM. The format type of the SCSI disk or Memory card is wrong. The file specified for loading is unusable by the MOTIF. The specified file name is unacceptable. Try entering a different name. You have attempted to delete, rename, or overwrite a read-only file. No more directories can be created below the current level. Directories below this level cannot be accessed. The file format type is not supported by the MOTIF. A SCSI error has occurred. Check the SCSI connections and termination. An error occurred while reading or writing to/from SCSI disk or Memory card. The file associated with the file to be loaded cannot be found (e.g., Sample voice files associated with the Song or Pattern file). You attempt to delete a folder that contains data. The disk (memory card or SCSI device connected to the MOTIF) is not supported by the MOTIF. The internal memory for Sequence data is full. The internal memory for Sequence data is full, preventing any further operation (such as recording, editing, Job execution, MIDI reception/transmission, or loading from Memory card or SCSI drive). Try again after erasing unwanted song, pattern, or user phrase data. You have attempted to record a pattern track to which a preset phrase is assigned. If you wish to use a preset phrase as a starting data for pattern recording, copy it to a user phrase before recording. When a Song/Pattern Job is executed, the selected track or range contains no data. Select an appropriate track or range. No check boxes have been checked in a Sequencer track Job which requires a check box selection. Check the appropriate check box. Exclusive data has been entered or changed without the necessary “End of Exclusive” byte (F7). Make sure F7 is included. The Multi-Part Plug-in board does not work because it has not been installed to slot 3. The Multi-Part Plug-in board should be installed to slot 3. The Effect Plug-in board does not work because it has not been installed to slot 1. The Effect Plug-in board should be installed to slot 1.A Pattern Job will result in the length of a Pattern being greater than 256 measures. A Pattern Job will result in the length of a phrase being greater than 256 measures. The maximum number of phrases (256) has been exceeded when recording, executing a Pattern Job, or editing. An unacceptable input or value has been specified. Check the input method or value. An unacceptable track number has been specified in the Song/Pattern mode. Select the track again. An unacceptable phrase number has been specified in the Pattern mode. Select the phrase again. An unacceptable measure number has been specified in the Song/Pattern mode. Select the measure again. In the Pattern Job mode, the meter (time signature) of the destination pattern is different from the meter of the source pattern. The sample memory is full and further sampling operations, Jobs, or load operations cannot be executed. The maximum overall number of samples (8192) has been exceeded. The sample length is too short and the Frequency Convert Job cannot be executed. The sampling frequency is too low and the Frequency Convert Job cannot be executed. The sample file specified for loading is unusable by the MOTIF. The linked sample files cannot be found during a load operation. The sample size is too large and the Time Stretch Job cannot be executed. An appropriate pair of expansion SIMMs is not properly installed, or the pair is not properly matched (page 287). The Plug-in board that has been installed to slot 1 does not work. The Plug-in board that has been installed to slot 2 does not work. The Plug-in board that has been installed to slot 3 does not work.
74MOTIF6 / MOTIF7 / MOTIF8 Messages Information Plug-in 1 type mismatch. Plug-in 2 type mismatch. Plug-in 3 type mismatch. PLG100 not supported. mLAN network error. mLAN connection error. mLAN now in Mixer mode. mLAN error (xxx). Copy protected. Digital in unlocked. Too many favorites Executing... Now working... Now loading... (xxxx) Now saving... (xxxx) Now checking plug-in board. Recording stopped. Receiving sample... Transmitting sample... MIDI bulk receiving... MIDI bulk transmitting... Completed. Becomes valid after power on. Scene stored Mixing stored Are you sure ? [YES]/[NO] Overwrite? [YES]/[NO] Cant undo. OK? [YES]/[NO]The User Voice created by using the Plug-in board previously installed to slot 1 (but now removed from slot 1) has been selected. The User Voice created by using the Plug-in board previously installed to slot 2 (but now removed from slot 2) has been selected. The User Voice created by using the Plug-in board previously installed to slot 3 (but now removed from slot 3) has been selected. The mLAN8E board is set to the Mixer mode by your computer, and the MOTIF cannot control the mLAN8E. Indicates an unspecified problem related to the mLAN8E. You have attempted to export or save a copy-protected digital audio source. Digital input signal of the AIEB2 is unlocked. Yo u’ve attempted to assign more than 256 voices to the Favorite category. A format operation or job is being executed. Please wait. Indicates that the MOTIF is currently engaged in some operation, such as writing to/reading from the disk, etc. Indicates that a file is being loaded. Indicates that a file is being saved. The MOTIF is checking the Plug-in board installation status when powering the MOTIF on. The Song/Pattern (phrase) recording is automatically stopped because the memory becomes full. The MOTIF is receiving sample data from Wave Editor. The MOTIF is transmitting sample data to Wave Editor. The MOTIF is receiving MIDI bulk data. The MOTIF is transmitting MIDI bulk data. The specified load, save, format, or other job has been completed. The newly entered SCSI ID number will take effect only by turning the power of the MOTIF off and on again. A Song scene has been stored. In the Song/Pattern mode, the Mixing settings have been automatically stored. Confirms whether you want to execute a specified operation or not. Press [INC/YES] or [DEC/NO] as required. Indicates a problem in the mLAN8E network. Check the on/off status of the LED lamps on the mLAN8E and refer to the Owner’s Manual of the mLAN8E. Indicates a problem in the mLAN8E connection. Check the on/off status of the LED lamps on the mLAN8E and refer to the Owner’s Manual of the mLAN8E. A save operation will overwrite data on the Memory card or SCSI disk, and this message confirms whether it is OK to continue or not. Press [INC/YES] or [DEC/NO] as required. When some jobs of the Song/Pattern are executed, the internal memory becomes full and undo cannot be used. Press [INC/YES] if this is OK, or [DEC/NO] to abort the operation. Try again after erasing unwanted songs, patterns, or user phrases. The Plug-in All Bulk Save function does not apply to the PLG100 series boards.
75 MOTIF6 / MOTIF7 / MOTIF8 OS UPDATE [CAUTIONS] Make sure to create the backup copy of your own data before executing the update. [UPDATE PROCEDURE] ∗ Tools required for update - 8MB or larger smart media (3.3V). Smart media floppy disk adaptor. Download the MOTIF updated program from the download page on the YSISS home page to the smart media (using the smart media floppy disk adaptor). (YSISS URL>> http://plaza.yamaha.co.jp/ysiss/ exindex.nsf) ∗ Insert a smart media containing only the update program (06380s.pgm) into the card slot on the main unit. 1. Insert the smart media into the slot on the rear panel. The correct direction of media is printed on the panel. (Fig.1) 2. Turn the power on with “REC” button and “STORE” button pressed and held. (Fig.2) The screen appears on LCD. //// MOTIF6,7,8 OS Updater//// Current Version Kernel : X.XX : X.XX Insert card including only one PGM file, and press [ENTER] to load. Or, play in standard MIDI file including the KERNEL SysEx Data. 3. Press “ENTER” button. The program is updated automatically and the process is displayed on LCD. //// MOTIF6,7,8 OS Updater//// ==== UPDATA FROM CARD MODE==== Include : 3 block (4 types) of OS. block #2 ∗∗∗∗∗∗∗∗∗∗∗∗ (xx.x%) Press EXIT to about loading. //// MOTIF6,7,8 OS Updater//// ==== UPDATA FROM CARD MODE==== Erasing flash ROM. ∗ DONT SHUTDOWN MOTIF6,7,8! ∗∗∗ ∗ block #2 //// MOTIF6,7,8 OS Updater//// ==== UPDATA FROM CARD MODE==== Writing OS into flash ROM. DONT SHUTDOWN MOTIF6,7,8! block #7 ∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗∗ (xx.x%) Take care not to remove the smart media or not to operate any buttons or keys in the process of updating, as it takes several minutes.(Fig.1) (Fig.2) Push Push 4. If the program successfully updated, the message appears to prompt to reboot the system. Turn the power off. //// MOTIF6,7,8 OS Updater//// ==== UPDATA FROM CARD MODE==== Completed. Reboot MOTIF6,7,8. 5. Remove the smart media from the slot. In the next, enter TEST MODE to initialize the data. 6. Turn the power on with “REMOTE” button and “REC” button pressed and held. The initial screen of TEST MODE appears on LCD. //// MOTIFx Test Program //// Firm Ver:X.XX Kernel Ver:X.XX Data Ver:X.XX ∗ [ENTER] :Test Start ∗ [STORE] :Factory Set ∗ [EXIT] :Exit Take care not to release the “REMOTE” button and “REC” button until the screen appears, as it takes several seconds. 7. Press “STORE” button. “Factory Set” runs and the date is set to the factory default settings. 8. Press “EXIT” button to exit TEST MODE. //// MOTIFx Test Program //// 31:EXIT :[NO] or [YES]