Home > Yamaha > Musical Instrument > Yamaha Motif 8 Service Manual

Yamaha Motif 8 Service Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Yamaha Motif 8 Service Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 255 Yamaha manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							61 MOTIF6 / MOTIF7 / MOTIF8
    Measuring Requirements
    When testing the unit in the MANUAL or AUTO mode,
    the following Instruments and jigs are required:
    Instruments: Frequency Counter, Oscilloscope, Level
    Indicator (JIS-C curve), Distortion Meter
    (Flat), Oscillometer, Keyboard Amplifier,
    PLG100-VH, etc.
    Jigs: MIDI Cable, Proprietary Expansion Board, etc.
    A. Entering Test Mode
    Push
    Turn on power with the [REMOTE CONTROL ON/OFF]
    and [REC] buttons pressed and held. The following screen
    appears. Press [ENTER] button to enter the test mode.
            //// MOTIFx Test Program ////
         Firm   Ver:0.30
         Kernel Ver:0.30
         Data   Ver:0.30
         * [ENTER] :Test Start
         * [STORE] :Factory Set
         * [EXIT]  :Exit
    From this screen, press [STORE] button to display the
    “T30 FACTORY SET” screen. press [EXIT] button to
    display the “T31 EXIT” screen.
    B. Test Procedure
    As the test mode is entered, the following screen appears:
           //// MOTIFx Test Program ////       
                                            
     01:Battery     :Press [ENTER]
    Use [DEC/NO] button and/or [INC/YES] button to select a
    test number.
    Press [ENTER] button to start the test with the selected
    number.
    Press [EXIT] button to instruct “T31 EXIT”.
    C. Test Procedure for NG
    If any of the following tests has resulted in NG, perform the
    following operation to have the system wait for a test number
    before repeating the test or proceeding to another test:
    Press [EXIT] button to have the system wait for a test
    number.Note: Note that this method does not support the [EXIT] test
    of “T04 Panel Switch”.
    T01: RAM Battery Check
    Initial Screen:
            //// MOTIFx Test Program ////
                                             
      01:Battery     :Press [ENTER]
    Description:
    Check to see whether the RAM backup battery voltage is
    OK (2.95 to 3.5 V) or NG.
    Procedure:
    Run the test.
    Check Item:
    Check the LCD for the test conclusion.
    Display of Test Conclusion:
    OK
            //// MOTIFx Test Program ////       
      01:Battery     :OK               3.2v  
     
    NG        //// MOTIFx Test Program ////
      01:Battery     :Low NG           1.2v
            //// MOTIFx Test Program ////
      01:Battery     :Hi NG            4.2v
    Ending Process:
    The test ends after displaying the test conclusion and
    enters the item selection status.
    T02: LCD, LED Blink Check
    Initial Screen:
            //// MOTIFx Test Program ////
      02:LCD,LED     :Press [ENTER]
    Description:
    This test inverses the monochrome LCD roughly every 0.5
    sec., and flashes all the LEDs.
    Make sure the backlights of the LCDs stay on.
    Make sure the LCD contrast can be controlled by moving
    the contrast VR.
    Display of Test Conclusion:
    None.
    Ending Process:
    Press [EXTI] button to exit the test. The Initial Screen
    reappears, waiting for a test number.
    Others:
    None. 
    						
    							62MOTIF6 / MOTIF7 / MOTIF8
    T03: LED Check
    Initial Screen:
            //// MOTIFx Test Program ////
      03:LED         :Press [ENTER]
    Description:
    This test turns LED’s in sequence, roughly every 0.5 sec.
    Make sure the LED’s normally operate and glow consis-
    tently.
    Procedure:
    Turn all the LED’s on the unit in sequence following the
    instructions below to make sure they all light up:
            //// MOTIFx Test Program ////
      03:LED         :Checking (xxxxxxx)
    xxxxxxx : LED Name
    When the LED’s stay on, sound a sine wave.
    After turning the last LED off, turn all the LEDs on.
    The following table shows the LED check sequence:
    OCTV-∗1 →OCTV+∗1 →PAN →
    CUTOFF →ASSGN-A →MEQ-L →
    VOLUME1 →REMOTE →EFB-INS →
    EFB-SYS →ARP →REC →
    PLAY →VOICE →PERFORM →
    MASTER →SONG →PATTERN →
    FILE →SAMPLE →MIXING →
    UTILITY →EDIT →SLOT1 →
    SLOT2 →SLOT3 →DRUM →
    PRE1 →PRE2 →PRE3 →
    GM →USER →PLG1 →
    PLG2 →PLG3 →CATEGRY →
    A →B →C →
    D →E →F →
    G →H →SECTION →
    1 →2 →3 →
    4 →5 →6 →
    7 →8 →TR.SEL →
    9 →10 →11 →
    12 →13 →14 →
    15 →16 →MUTE
    ∗ Only MOTIF6, 7
    Display of Test Conclusion:
    None.
    Ending Process:
    Press [EXIT] to exit the test. The Initial Screen reappears,
    waiting for a test number.T04: Panel Switch Check
    Initial Screen:
            //// MOTIFx Test Program ////
      04:Panel SW    :Press [ENTER]
    Description:
    Make sure the panel switches operate normally.
    Procedure:
    Toggle all the switches on the unit ON and OFF following
    the instructions below:
            //// MOTIFx Test Program ////
      04:Panel SW    :Press [xxxxxxx]
    xxxxxxx : Switch Name
    If a switch operates normal, a sine wave sounds while the
    switch is active and the test proceeds to the next test.
    If an unexpected code is sent, NG appears and no sine
    wave sounds.
    After this, if normal code is received, the test proceeds to
    the next switch.
    If all the switches operate normal, OK appears on the
    LCD.
    The following table shows the switch check sequence:
    OCTV-∗1 →OCTV+∗1 →KNOB →
    REMOTE →EFB-INS →EFB-SYS →
    ARP →TOP →> →REC →STOP →
    PLAY →VOICE →PERFORM →
    MASTER →SONG →PATTERN →
    FILE →SAMPLE →MIXING →
    UTILITY →EDIT →JOB →
    STORE →SF1 →SF2 →
    SF3 →SF4 →SF5 →
    INFO →F1 →F2 →
    F3 →F4 →F5 →
    F6 →DEC →INC →
    C-LEFT →C-UP →C-RGHT →
    EXIT →C-DOWN →ENTER →
    DRUM →PRE1 →PRE2 →
    PRE3 →GM →USER →
    PLG1 →PLG2 →PLG3 →
    CATEGRY →A →B →
    C →D →E →
    F →G →H →
    SECTION →1 →2 →
    3 →4 →5 →
    6 →7 →8 →
    TR.SEL →9 →10 → 
    						
    							63 MOTIF6 / MOTIF7 / MOTIF8
    11 →12 →13 →
    14 →15 →16 →
    MUTE
    * Only MOTIF6, 7
    Check Item:
    Make sure all the switches operate normal.
    Display of Test Conclusion:
    OK
            //// MOTIFx Test Program ////
     04:Panel SW    :OK
    NG        //// MOTIFx Test Program ////
      04:Panel SW    :Press [xxxxxxx]  NG
    Ending Process:
    If all the switches are successfully tested, OK appears on
    the LCD, the test ends and returns to the item select status.
    For NG determined on the way of the test, see “C.
    Procedure for NG”.
    ∗
     For NG determined on the way of the test, see “C.
    Procedure for NG”.
    T05: Encoder Check
    Initial Screen:
            //// MOTIFx Test Program ////
      05:Encoder     :Press [ENTER]
    Description:
    Make sure the encoder operates normally.
    Procedure:
    Turn the encoder clockwise, then counterclockwise,
    following the instructions displayed on the following LCD.
    Make sure that “OK” appears on the LCD. + 0 ->  + 8(-0) -
    > -8
            //// MOTIFx Test Program ////
      05:Encoder     : xx
    yy : Target value
    xx : Current value
    Display of Test Conclusion:
    OK
            //// MOTIFx Test Program ////
      05:Encoder     :OK
    NG No display
    ∗
     For NG determined on the way of the test, see “C.
    Procedure for NG”.T06: Knob1-4 Check
    Initial Screen:
            //// MOTIFx Test Program ////
      06:Knob        :Press [ENTER]
    Description:
    Make sure knobs operate normally.
    Procedure:
    Move each of knobs following the instructions appear on
    the LCD from 64(63-65) to 127(126-127), then to 0 (0-1),
    that is, from the Center to Right, then to Left, smoothly.
    Make sure that “OK” appears on the LCD.
    The knobs can be checked in any order.
            //// MOTIFx Test Program ////
      06:Knob       :                       
         Knob-1      :OK                     
         Knob-2      : xxx
         Knob-3      : xxx
         Knob-4      : xxx
    yyy : Target value
    xxx : Current value
    Display of Test Conclusion:
    OK
            //// MOTIFx Test Program ////
      06:Knob       :OK
         Knob-1      :OK
         Knob-2      :OK
         Knob-3      :OK
         Knob-4      :OK
    NG No display
    Ending Process:
    The test ends after displaying the conclusion and returns to
    the item select status.
    ∗
     For NG determined on the way of the test, see “C.
    Procedure for NG”.
    T07: Slider
    Initial Screen:
            //// MOTIFx Test Program ////
      07:Slider      :Press [ENTER]
    Description:
    Make sure sliders operate normally.
    Procedure:
    Move each of sliders following the instructions appear on
    the LCD from LCD0(0-1) to 127(126-127), that is, from
    the Bottom to Top, smoothly.
    Make sure that “OK” appears on the LCD.
    The sliders can be checked in any order. 
    						
    							64MOTIF6 / MOTIF7 / MOTIF8
            //// MOTIFx Test Program ////
      07:Slider      :
         Slider-1    : xxx
         Slider-2    : xxx
         Slider-3    : xxx
         Slider-4    :OK
    yyy : Target value
    xxx : Current value
    Display of Test Conclusion:
    OK
            //// MOTIFx Test Program ////
      07:Slider      :OK
         Slider-1    :OK
         Slider-2    :OK
         Slider-3    :OK
         Slider-4    :OK
    NG No display
    ∗
     For NG determined on the way of the test, see “C.
    Procedure for NG”.
    T08: 1KeyOn Check
    Initial Screen:
            //// MOTIFx Test Program ////
      08:1KeyOn      :Press [ENTER]
    Description:
    Make sure the keyboard operates normally.
    Procedure:
    Enter C3 into Key Code.
    C3
            //// MOTIFx Test Program ////
      08:1KeyOn      :Press [C3 Key]
    Display of Test Conclusion:
    OK
            //// MOTIFx Test Program ////
      08:1KeyOn      :OK
    NG No display∗
     For NG determined on the way of the test, see “C.
    Procedure for NG”.
    T09: Keyboard + AT Check
    Initial Screen:
            //// MOTIFx Test Program ////
      09:Keyboard + AT :Press [ENTER]
    Description:
    Make sure the keyboard operates normally.
    Make sure “After Touch” operates normally.
    Procedure:
    This test makes scaling as following.
    MOTIF6: 61 keys, C1 to C6.
    MOTIF7: 76 keys, E0 to G6.
    MOTIF8: 88 keys, A-0 to C7.
    Move “After Touch” following the instructions appear on
    the LCD, toggling between 127 and 0, that is,
    Pressing and Releasing, smoothly.
            //// MOTIFx Test Program ////
      09:Keyboard + AT :
         Scaling     :OK
         After Touch : zzz
    yyy : Target value
    zzz : Current value
    For Keyboard inspection (C 1):
            //// MOTIFx Test Program ////
      09:Keyboard + AT :                     
         Scaling     :Press C 1       Vel=xxx
         After Touch : zzz
    xxx : Pressing key velocity
    yyy : Target value
    zzz : Current value
    After Touch inspection
    Activate (Key On) the keyboard displayed on the LCD.
    When the keyboard is activated (Key On), the Velocity of
    the action is displayed, TONE (1 KHz) sounds and the next
    keyboard test starts.
    The sound generated is a sine wave equal to 1 KHz
    sounding check.
    If an unexpected code is sent, NG appears and no sound is
    generated.
    Then, if a normal code is received, the following keyboard
    test starts.
    If all the keyboards are found to be normal, OK appears on
    the LCD. 
    						
    							65 MOTIF6 / MOTIF7 / MOTIF8
    Display of Test Conclusion:
    OK
            //// MOTIFx Test Program ////
      09:Keyboard + AT :OK
         Scaling     :OK
         After Touch :OK
    NG No display
    ∗
     For NG determined on the way of the test, see “C.
    Procedure for NG”.
    T10: PB, MW, BC Check
    Connect the breath controller before starting this test.
    Initial Screen:
            //// MOTIFx Test Program ////
      10:PB,MW,BC    :Press [ENTER]
    Description:
    Make sure “Pitch Bend, “Modulation Wheel” and “Breath
    Controller” operate normally.
    Procedure:
    Following the instructions appear on the LCD,
    For PB: Move from 64 (63-65) to 127 (126-127), then to
    0 (0-1), that is, from the Center to Top, then to
    Bottom, smoothly.
    For MW: Move from 0 (0-1) to 127(126-127), that is, from
    the Bottom to Top, smoothly.
    For BC: Change from 127 (122-127) to 0 (0-5), that is,
    from No-blow to Blow, smoothly.
    If a message, “Extract Plug!” appears, pull the jack out.
    (OK is assumed if the value is ## or more.)
            //// MOTIFx Test Program ////
      10:PB,MW,BC    :
         Pitch Bend  : xxx
         Modulation  : xxx
         Breath      : xxx
    yyy : Target value
    xxx : Current value
    The items can be checked in any order.
    Display of Test Conclusion:
    OK
            //// MOTIFx Test Program ////
      10:PB,MW,BC    :OK
         Pitch Bend  :OK
         Modulation  :OK
         Breath      :OK
    NG No display
    ∗
     For NG determined on the way of the test, see “C.
    Procedure for NG”.T11: Foot Controller, Foot Switch Check
    Initial Screen:
            //// MOTIFx Test Program ////
      11:FC1/2,Sus/FS:Press [ENTER]
    Description:
    Make sure “Foot Controller 1/2,” “Sustain Sw” and “Foot
    Sw” operate normally.
    Procedure:
    Move the “Foot Controller 1/2,” following the instructions
    appear on the LCD, from 0 (0-2) to 127 (125-127), that is,
    Release to Depress, smoothly.
    Turn on (0) and off (1) the “Foot Switch” and “Sustain
    Switch”.
            //// MOTIFx Test Program ////
      11:FC1/2,Sus/FS:
         FC1         :OK
         FC2         : xxx
         SustainSw   : xxx
         FootSw      : xxx
    yyy : Target value
    xxx : Current value
    The items can be checked in any order.
    Check Item:
    Make sure the digit changes, and OK appears on the LCD.
    Display of Test Conclusion:
    OK
            //// MOTIFx Test Program ////
      11:FC1/2,Sus/FS :OK
         FC1 :OK
         FC2 :OK
         SustainSw :OK
         FootSw :OK
    NG No display
    ∗
     For NG determined on the way of the test, see “C.
    Procedure for NG”.
    T12: MIDI In/Out/Thru Check
    Initial Screen:
            //// MOTIFx Test Program ////
      12:MIDI        :Press [ENTER]
    Description:
    Checks the operation of MIDI IN/OUT/THRU with a test
    pattern (AA EF 00 55).
    Procedure:
    Connect IN and OUT with a MIDI cable and run the test.
    If it is OK, make sure the MIDI monitor outputs the test
    pattern (AA EF 00 55) from THRU. 
    						
    							66MOTIF6 / MOTIF7 / MOTIF8
    Check Item:
    Make sure IN and OUT are OK, and THRU outputs a test
    pattern.
    Display of Test Conclusion:
    OK
            //// MOTIFx Test Program ////
      12:MIDI :OK
    NG        //// MOTIFx Test Program ////
      12:MIDI :NG
    If an unexpected data is received:
            //// MOTIFx Test Program ////
      12:MIDI :NG             TIME OUT
    If the reception does not complete within a certain time:
    Ending Process:
    The test ends after displaying the test conclusion and
    enters the item selection status.
    T13: USB(MIDI) Check
    Initial Screen:
            //// MOTIFx Test Program ////
      13:USB(MIDI)   :Press [ENTER]
    Description:
    Checks the operation of USB (MIDI) IN/OUT with a test
    pattern (f0 55 00 f7).
    Procedure:
    Connect the USB terminal and PC to run the test.
    Check Item:
    Make sure IN and OUT are OK.
    Display of Test Conclusion:
    OK
            //// MOTIFx Test Program ////
      13:USB(MIDI) :OK
    NG        //// MOTIFx Test Program ////
      13:USB(MIDI)   :NG
    Display resulted from an unexpected data
            //// MOTIFx Test Program ////
      13:USB(MIDI)   :NG             TIME OUT
    Display resulted from reception which does not complete
    within a certain time:
    Ending Process:
    The test ends after displaying the test conclusion and
    enters the item selection status.
    T14: 1 kHz OUTPUT L
    Initial Screen:
            //// MOTIFx Test Program ////
      14:OUTPUT-L    :Press [ENTER]
    Description:
    Insert plugs into OUTPUT-L, OUTPUT-R, Assignable-L,
    Assignable-R, PHONES(L) and PHONES(R) to monitor
    the frequencies, output waveforms and output levels using
    a frequency counter, oscilloscope and level indicator (with
    JIS_C filters).
    Connect a device, such as an MD, to the Optical Output
    terminal.
    Set Master Volume to the max.
    When sounding, the LCD displays as follows:
            //// MOTIFx Test Program ////
      14:OUTPUT-L    :ON
    Check Item:
    OUTPUT-L: Sine wave, 1 kHz ± 1.5 Hz, + 5.0 ± 2 dBm
    (loading, 10 kΩ; distortion factor, 0.1% or less)
    OUTPUT-R: -80 dBm or less (loading, 10 kΩ)
    Assignable-L: Sine wave, 1 kHz ± 1.5 Hz, + 5.0 ± 2 dBm
    (loading, 10 kΩ; distortion factor, 0.1% or less)
    Assignable-R: -83 dBm or less (loading, 10 kΩ)
    PHONES(L): Sine wave, 1 kHz ± 1.5 Hz, + 6.0 ± 2 dBm
    (loading, 33Ω; distortion factor, 0.1% or less)
    PHONES(R): -60 dBm or less (loading, 33Ω)
    Optical: Set SONY MD WALKMAN MZ-R55 to VOL=30
    and connected to Optical IN
    MDLINE L: -25 ± 2 dBm (loading, 10 kΩ)
    AIEB2 (Option)
    AS1, 3, 5: 1kHz ± 1.5Hz, Sine wave, +6.0 ± 2dBm
    (loading, 10Ω; distortion factor, 0.1% or less)
    AS2, 4, 6: -90dBm or less (loading, 10Ω)
    Display of Test Conclusion:
    OK: No display
    NG: No display
    Ending Process:
    Press [EXIT] button to exit the test. The Initial Screen
    reappears, waiting for a test number. 
    						
    							67 MOTIF6 / MOTIF7 / MOTIF8
    T15: 1 kHz OUTPUT R Check
    Initial Screen:
            //// MOTIFx Test Program ////
      15:OUTPUT-R    :Press [ENTER]
    Procedure:
    Insert plugs into OUTPUT-L, OUTPUT-R, Assignable-L,
    Assignable-R, PHONES (L) and PHONES (R) to monitor
    the frequencies, output waveforms and output levels using
    a frequency counter, oscilloscope and level indicator (with
    JIS_C filters).
    Set Master Volume to max.
    When sounding, the LCD displays as follows:
            //// MOTIFx Test Program ////
      15:OUTPUT-R    :ON
    Check Item:
    OUTPUT-L: -80 dBm or less (loading, 10 kΩ)
    OUTPUT-R: Sine wave, 1 kHz ± 1.5 Hz, + 5.0 ± 2 dBm
    (loading, 10 kΩ; distortion factor, 0.1% or less)
    Assignable-L: -83 dBm or less (loading, 10 kΩ)
    Assignable-R: Sine wave, 1 kHz ± 1.5 Hz, + 5.0 ± 2 dBm
    (loading, 10 kΩ; distortion factor, 0.1% or less)
    PHONES(L): -60 dBm or less (loading, 33 Ω)
    PHONES(R): Sine wave, 1 kHz ± 1.5 Hz, + 6.0 ± 2 dBm
    (loading, 33 Ω; distortion factor, 0.1% or less)
    AIEB2 (Option)
    AS1, 3, 5: -90dBm or less (loading, 10 Ω)
    AS2, 4, 6: 1kHz ± 1.5Hz, Sine wave, +6.0 ± 2dBm
    (loading, 10 Ω; distortion factor, 0.1% or less)
    Display of Test Conclusion:
    OK: No display
    NG: No display
    Ending Process:
    Press [EXIT] button to exit the test. The Initial Screen
    reappears, waiting for a test number.
    Others:
    None.
    T16: A/D -> D/A (MIC) Check
    Initial Screen:
            //// MOTIFx Test Program ////
      16:AD-DA(MIC)  :Press [ENTER]
    Description:
    Tests the signal path from input to D/A output. (The Gain
    is defaulted to MIC.)Supply a sine wave of 1 kHz ± 5 Hz and -50.0 dBm ± 0
    dBm (distortion factor, 0.1% or less) to the A/D input in
    the following order to make sure the level specified below
    is output from the Outputs L and R.
            //// MOTIFx Test Program ////
      16:AD-DA(MIC)  :ON
    Check Item:
    Move the A/D GAIN VOLUME to make sure the sound
    level varies.
    OUTPUT-L: Sine wave, 1 kHz ± 5 Hz, + 4.0 ± 2 dBm
    (loading, 10 kΩ; distortion factor, 2.00% or less)
    OUTPUT-R: -60.0 dBm or less (loading, 10 kΩ)
    Display of Test Conclusion:
    No display
    Ending Process:
    Press [EXIT] button to end sounding, waiting for a test
    number.
    Others:
    None.
    T17: A/D -> D/A (LINE) Check
    Initial Screen:
            //// MOTIFx Test Program ////
      17:AD-DA(LINE) :Press [ENTER]
    Description:
    Tests the signal path from the A/D input to D/A output.
    (The Gain is defaulted to LINE.)
    Supply a sine wave of 1 kHz ± 5 Hz and -17.0 dBm ± 0
    dBm (distortion factor, 0.1% or less) to the A/D input in
    the following order to make sure the level specified below
    is output from the Outputs L and R.
            //// MOTIFx Test Program ////
      17:AD-DA(LINE) :ON
    Check Item:
    Move the A/D GAIN VOLUME to make sure the sound
    level varies.
    OUTPUT-L: -70.0 dBm or less (loading, 10 kΩ)
    OUTPUT-R: sine wave, 1 kHz ± 5 Hz, + 3.0 ± 2 dBm
    (loading, 10 kΩ; distortion factor, 0.10% or less)
    Display of Test Conclusion:
    No display
    Ending Process:
    Press [EXIT] button to stop sounding, waiting for a test
    number.
    Others:
    None. 
    						
    							68MOTIF6 / MOTIF7 / MOTIF8
    T18: CARD (WRITE/READ) Check
    Initial Screen:
            //// MOTIFx Test Program ////
      18:Card        :Press [ENTER]
    Description:
    Make sure the Smart Media is protected.
    Checks the Format, Write, Read and Verify on the Smart
    Media.
    Make sure the Smart Media is removable.
    Procedure:
    First, insert a protected Smart Media into the slot and run
    the test.
    Then, insert a not-protected Smart Media into the slot and
    run the test.
    Run the test without a Smart Media inserted.
    Check Item:
    Check the result of LCD test. Make sure a WRPRT error
    occurs when a Smart Media is inserted. Then, make sure
    OK appears when a Smart Media is inserted.
    Display of Test Conclusion:
    OK
            //// MOTIFx Test Program ////
      18:Card        :OK
    NG        //// MOTIFx Test Program ////
      18:Card        :NG              xxxxxx
    xxxxxx : ERROR CODE
    Error code :
    Error code
    RD/WR: Read/Write error
    NOCARD: No card (Card not inserted)
    WRPRT: Write protect
    Ending Process:
    The test ends after displaying the conclusion and returns to
    the item select status.
    For NG determined on the way of the test, see “C.
    Procedure for NG”.
    T19: SCSI
    Initial Screen:
            //// MOTIFx Test Program ////
      19:SCSI        :Press [ENTER]
    Description:
    Performs Read/Write by 1 sector to/from a hard disk
    connected to a SCSI terminal.
    Sets the SCSI ID of the hard disk to 4.Procedure:
    Connect a hard disk to a SCSI terminal to run the test.
    Check Item:
    Check the LCD for the test conclusion.
    Display of Test Conclusion:
    OK
            //// MOTIFx Test Program ////
      19:SCSI        :OK
    NG        //// MOTIFx Test Program ////
      19:SCSI        :NG
    Ending Process:
    The test ends after displaying the conclusion and returns to
    the item select status.
    For NG determined on the way of the test, see “C.
    Procedure for NG”.
    T20: Plug-In 1 Check
    Initial Screen:
            //// MOTIFx Test Program ////
      20:PLG1        :Press [ENTER]
    Description:
    Checks for the connection at Plug-in Slot 1, sending/
    reception through Control Line, MIDI Line and IN/OUT
    through MEL Line. If Insertion Check is successfully
    ended, these checks are implemented as follows: (1)
    Perform Board Type Request. (2) Receive Type. (3) Check
    to see whether it is a VH Board or not. (4) Send TEST
    CODE to Plug-in’s MIDI LINE. (5) Check IN/OUT on
    MEL Line. (6) Output 1 k.Hz sine wave to Plug-in.
    Procedure:
    Connect Vocal Harmony Plug-in Board to Plug-in Slot 1
    and make sure the following level outputs from Outputs R
    and L exist. Before this test, set Master Volume to the max.
    Check Item:
     OUTPUT-L: Sine wave, 1 kHz ± 5 Hz, + 5.0 ± 2 dBm
    (loading, 10 kΩ; distortion factor, 2.00% or less)
    OUTPUT-R: Sine wave, 1 kHz ± 5 Hz, + 5.0 ± 2 dBm
    (loading, 10 kΩ; distortion factor, 2.00% or less)
    Display of Test Conclusion:
    OK No display
    NG
            //// MOTIFx Test Program ////
      20:PLG1        :NG            xxxxxxxx
    xxxxxxxx : ERROR CODE 
    						
    							69 MOTIF6 / MOTIF7 / MOTIF8
    Error code :
    NG_BOARD: Board other than VH is inserted.
    NO_BOARD: No board (No board is inserted)
    MIDI: MIDI LINE faulty
    Ending Process:
    Press [EXIT] button once to stop sounding, twice to
    determine OK or NG or three times to enter the status
    waiting for a test number.
    T21: Plug-In 2 Check
    Initial Screen:
            //// MOTIFx Test Program ////
      21:PLG2        :Press [ENTER]
    Description:
    Checks for connection at Plug-in Slot 2, sending/reception
    through Control Line, MIDI Line and IN/OUT through
    MEL Line. If Insertion Check is successfully ended, these
    checks are implemented as follows: (1) Perform Board
    Type Request. (2) Receive Type. (3) Check to see whether
    it is a VH Board or not. (4) Send TEST CODE to Plug-in’s
    MIDI LINE. (5) Check IN/OUT on MEL Line. (6) Output
    1 k.Hz sine wave to Plug-in.
    Procedure:
    Connect Vocal Harmony Plug-in Board to Plug-in Slot 2
    and make sure the following level outputs from Outputs R
    and L exist. Before this test, set Master Volume to the max.
    Check Item:
    OUTPUT-L: Sine wave, 1 kHz ± 5 Hz, + 1.0 ± 2 dBm
    (loading, 10 kΩ; distortion factor, 2.00% or less)
    OUTPUT-R: Sine wave, 1 kHz ± 5 Hz, + 1.0 ± 2 dBm
    (loading, 10 kΩ; distortion factor, 2.00% or less)
    Display of Test Conclusion:
    OK No display
    NG
            //// MOTIFx Test Program ////
      21:PLG2        :NG            xxxxxxxx
    xxxxxxxx : ERROR CODE
    Error code :
    NG_BOARD: Board other than VH is inserted.
    NO_BOARD: No board (No board is inserted)
    MIDI: MIDI LINE faulty
    Ending Process:
    Press [EXIT] button once to stop sounding, twice to
    determine OK or NG or three times to enter the status
    waiting for a test number.T22: Plug-In 3 button
    Initial Screen:
            //// MOTIFx Test Program ////
      22:PLG3        :Press [ENTER]
    Description:
    Checks for connection at Plug-in Slot 3, sending/reception
    through Control Line, MIDI Line and IN/OUT through
    MEL Line. If Insertion Check is successfully ended, these
    checks are implemented as follows: (1) Perform Board
    Type Request. (2) Receive Type. (3) Make sure it is a VH
    Board. (4) Send TEST CODE to Plug-in’s MIDI LINE. (5)
    Check IN/OUT on MEL Line. (6) Output 1 k.Hz sine wave
    to Plug-in.
    Procedure:
    Connect Vocal Harmony Plug-in Board to Plug-in Slot 3
    and make sure the following level outputs from Outputs R
    and L exist. Before this test, set Master Volume to the max.
    Check Item:
    OUTPUT-L: Sine wave, 1 kHz ± 5 Hz, + 5.0 ± 2 dBm
    (loading, 10 kΩ; distortion factor, 2.00% or less)
    OUTPUT-R: Sine wave, 1 kHz ± 5 Hz, + 5.0 ± 2 dBm
    (loading, 10 kΩ; distortion factor, 2.00% or less)
    Display of Test Conclusion:
    OK No display
    NG
            //// MOTIFx Test Program ////
      22:PLG3        :NG            xxxxxxxx
    xxxxxxxx : ERROR CODE
    Error code:
    NG_BOARD: Board other than VH is inserted.
    NO_BOARD: No board (No board is inserted)
    MIDI: MIDI LINE faulty
    Ending Process:
    Press [EXIT] button once to stop sounding, twice to
    determine OK or NG or three times to enter the status
    waiting for a test number.
    T23: Digital Input Check
    Initial Screen:
            //// MOTIFx Test Program ////
      23:Digital In  :Press [ENTER]
    Description:
    Tests the signal path from the AIEB1 Digital input to the
    D/A output. 
    						
    							70MOTIF6 / MOTIF7 / MOTIF8
    Procedure:
    Loop between the AIEB1 Digital input and output to sound
    a sine wave to the Digital output.
    Make sure the following level outputs are sent out from the
    ChStatus, and Outputs R and L.
            //// MOTIFx Test Program ////
      23:Digital In  :ON
         Ch Status   :xx
    xx : OK/NG
    Check Item:
    Ch Status: OK/NG
    OUTPUT-L: Sine wave, 1 kHz ± 5 Hz, + 1.0 ± 2 dBm
    (loading, 10 kΩ; distortion factor, 0.1% or less)
    Display of Test Conclusion:
    NG
            //// MOTIFx Test Program ////
      23:Digital In  :ON
         Ch Status   :NG
    Ending Process:
    Press [EXIT] button to end sounding, waiting for a test
    number.
    T24: Optical Input Check
    Initial Screen:
            //// MOTIFx Test Program ////
      24:Optical In  :Press [ENTER]
    Description:
    Tests the signal path from the AIEB2 Optical input to D/A
    output.
    Procedure:
    Loop between the AIEB2 Optical input and output to
    sound a sine wave to the Optical output.
    Make sure the following level outputs are sent out from the
    ChStatus, and Outputs R and L.
            //// MOTIFx Test Program ////
      24:Optical In  :ON
         Ch Status   :xx
    xx : OK/NG
    Check Item:
    Ch Status: OK/NG
    OUTPUT-L: Sine wave, 1 kHz ± 5 Hz, + 1.0 ± 2 dBm
    (loading, 10 kΩ; distortion factor, 0.1% or less)
    Display of Test Conclusion:
    NG
            //// MOTIFx Test Program ////
      24:Optical In  :ON
         Ch Status   :NG
    Ending Process:
    Press [EXIT] button to end sounding, waiting for a test
    number.
    T25: SIMM Check
    Initial Screen:
            //// MOTIFx Test Program ////
      25:SIMM        :Press [ENTER]
    Description:
    Performs Read, Write and Verify tests on SIMM.
    Procedure:
    Run the test.
    Check Item:
    Check the LCD for the test conclusion.
    Display of Test Conclusion:
    OK
            //// MOTIFx Test Program ////
      25:SIMM        :OK
         CN-19:OK
         CN-20:OK
    NG        //// MOTIFx Test Program ////
      25:SIMM        :NG
         CN-19:OK
         CN-20:NG
    If any IC is found to be NG, this test determines NG.
    Ending Process:
    The test ends after displaying the conclusion and returns to
    the item select status.
    T26: SIMM Full R/W Test
    Initial Screen:
            //// MOTIFx Test Program ////
      26:SIMM(Full)  :Press [ENTER]
    Description:
    Performs Full Address Read, Write and Verify tests on
    SIMM.
    Procedure:
    Run the test.
    Check Item:
    Check the LCD for the test conclusion.
    Display of Test Conclusion:
    OK
            //// MOTIFx Test Program ////
      26:SIMM(Full)  :OK
         CN-19:OK
         CN-20:OK 
    						
    All Yamaha manuals Comments (0)