61 MOTIF6 / MOTIF7 / MOTIF8 Measuring Requirements When testing the unit in the MANUAL or AUTO mode, the following Instruments and jigs are required: Instruments: Frequency Counter, Oscilloscope, Level Indicator (JIS-C curve), Distortion Meter (Flat), Oscillometer, Keyboard Amplifier, PLG100-VH, etc. Jigs: MIDI Cable, Proprietary Expansion Board, etc. A. Entering Test Mode Push Turn on power with the [REMOTE CONTROL ON/OFF] and [REC] buttons pressed and held. The following screen appears. Press [ENTER] button to enter the test mode. //// MOTIFx Test Program //// Firm Ver:0.30 Kernel Ver:0.30 Data Ver:0.30 * [ENTER] :Test Start * [STORE] :Factory Set * [EXIT] :Exit From this screen, press [STORE] button to display the “T30 FACTORY SET” screen. press [EXIT] button to display the “T31 EXIT” screen. B. Test Procedure As the test mode is entered, the following screen appears: //// MOTIFx Test Program //// 01:Battery :Press [ENTER] Use [DEC/NO] button and/or [INC/YES] button to select a test number. Press [ENTER] button to start the test with the selected number. Press [EXIT] button to instruct “T31 EXIT”. C. Test Procedure for NG If any of the following tests has resulted in NG, perform the following operation to have the system wait for a test number before repeating the test or proceeding to another test: Press [EXIT] button to have the system wait for a test number.Note: Note that this method does not support the [EXIT] test of “T04 Panel Switch”. T01: RAM Battery Check Initial Screen: //// MOTIFx Test Program //// 01:Battery :Press [ENTER] Description: Check to see whether the RAM backup battery voltage is OK (2.95 to 3.5 V) or NG. Procedure: Run the test. Check Item: Check the LCD for the test conclusion. Display of Test Conclusion: OK //// MOTIFx Test Program //// 01:Battery :OK 3.2v NG //// MOTIFx Test Program //// 01:Battery :Low NG 1.2v //// MOTIFx Test Program //// 01:Battery :Hi NG 4.2v Ending Process: The test ends after displaying the test conclusion and enters the item selection status. T02: LCD, LED Blink Check Initial Screen: //// MOTIFx Test Program //// 02:LCD,LED :Press [ENTER] Description: This test inverses the monochrome LCD roughly every 0.5 sec., and flashes all the LEDs. Make sure the backlights of the LCDs stay on. Make sure the LCD contrast can be controlled by moving the contrast VR. Display of Test Conclusion: None. Ending Process: Press [EXTI] button to exit the test. The Initial Screen reappears, waiting for a test number. Others: None.
62MOTIF6 / MOTIF7 / MOTIF8 T03: LED Check Initial Screen: //// MOTIFx Test Program //// 03:LED :Press [ENTER] Description: This test turns LED’s in sequence, roughly every 0.5 sec. Make sure the LED’s normally operate and glow consis- tently. Procedure: Turn all the LED’s on the unit in sequence following the instructions below to make sure they all light up: //// MOTIFx Test Program //// 03:LED :Checking (xxxxxxx) xxxxxxx : LED Name When the LED’s stay on, sound a sine wave. After turning the last LED off, turn all the LEDs on. The following table shows the LED check sequence: OCTV-∗1 →OCTV+∗1 →PAN → CUTOFF →ASSGN-A →MEQ-L → VOLUME1 →REMOTE →EFB-INS → EFB-SYS →ARP →REC → PLAY →VOICE →PERFORM → MASTER →SONG →PATTERN → FILE →SAMPLE →MIXING → UTILITY →EDIT →SLOT1 → SLOT2 →SLOT3 →DRUM → PRE1 →PRE2 →PRE3 → GM →USER →PLG1 → PLG2 →PLG3 →CATEGRY → A →B →C → D →E →F → G →H →SECTION → 1 →2 →3 → 4 →5 →6 → 7 →8 →TR.SEL → 9 →10 →11 → 12 →13 →14 → 15 →16 →MUTE ∗ Only MOTIF6, 7 Display of Test Conclusion: None. Ending Process: Press [EXIT] to exit the test. The Initial Screen reappears, waiting for a test number.T04: Panel Switch Check Initial Screen: //// MOTIFx Test Program //// 04:Panel SW :Press [ENTER] Description: Make sure the panel switches operate normally. Procedure: Toggle all the switches on the unit ON and OFF following the instructions below: //// MOTIFx Test Program //// 04:Panel SW :Press [xxxxxxx] xxxxxxx : Switch Name If a switch operates normal, a sine wave sounds while the switch is active and the test proceeds to the next test. If an unexpected code is sent, NG appears and no sine wave sounds. After this, if normal code is received, the test proceeds to the next switch. If all the switches operate normal, OK appears on the LCD. The following table shows the switch check sequence: OCTV-∗1 →OCTV+∗1 →KNOB → REMOTE →EFB-INS →EFB-SYS → ARP →TOP →> →REC →STOP → PLAY →VOICE →PERFORM → MASTER →SONG →PATTERN → FILE →SAMPLE →MIXING → UTILITY →EDIT →JOB → STORE →SF1 →SF2 → SF3 →SF4 →SF5 → INFO →F1 →F2 → F3 →F4 →F5 → F6 →DEC →INC → C-LEFT →C-UP →C-RGHT → EXIT →C-DOWN →ENTER → DRUM →PRE1 →PRE2 → PRE3 →GM →USER → PLG1 →PLG2 →PLG3 → CATEGRY →A →B → C →D →E → F →G →H → SECTION →1 →2 → 3 →4 →5 → 6 →7 →8 → TR.SEL →9 →10 →
63 MOTIF6 / MOTIF7 / MOTIF8 11 →12 →13 → 14 →15 →16 → MUTE * Only MOTIF6, 7 Check Item: Make sure all the switches operate normal. Display of Test Conclusion: OK //// MOTIFx Test Program //// 04:Panel SW :OK NG //// MOTIFx Test Program //// 04:Panel SW :Press [xxxxxxx] NG Ending Process: If all the switches are successfully tested, OK appears on the LCD, the test ends and returns to the item select status. For NG determined on the way of the test, see “C. Procedure for NG”. ∗ For NG determined on the way of the test, see “C. Procedure for NG”. T05: Encoder Check Initial Screen: //// MOTIFx Test Program //// 05:Encoder :Press [ENTER] Description: Make sure the encoder operates normally. Procedure: Turn the encoder clockwise, then counterclockwise, following the instructions displayed on the following LCD. Make sure that “OK” appears on the LCD. + 0 -> + 8(-0) - > -8 //// MOTIFx Test Program //// 05:Encoder : xx yy : Target value xx : Current value Display of Test Conclusion: OK //// MOTIFx Test Program //// 05:Encoder :OK NG No display ∗ For NG determined on the way of the test, see “C. Procedure for NG”.T06: Knob1-4 Check Initial Screen: //// MOTIFx Test Program //// 06:Knob :Press [ENTER] Description: Make sure knobs operate normally. Procedure: Move each of knobs following the instructions appear on the LCD from 64(63-65) to 127(126-127), then to 0 (0-1), that is, from the Center to Right, then to Left, smoothly. Make sure that “OK” appears on the LCD. The knobs can be checked in any order. //// MOTIFx Test Program //// 06:Knob : Knob-1 :OK Knob-2 : xxx Knob-3 : xxx Knob-4 : xxx yyy : Target value xxx : Current value Display of Test Conclusion: OK //// MOTIFx Test Program //// 06:Knob :OK Knob-1 :OK Knob-2 :OK Knob-3 :OK Knob-4 :OK NG No display Ending Process: The test ends after displaying the conclusion and returns to the item select status. ∗ For NG determined on the way of the test, see “C. Procedure for NG”. T07: Slider Initial Screen: //// MOTIFx Test Program //// 07:Slider :Press [ENTER] Description: Make sure sliders operate normally. Procedure: Move each of sliders following the instructions appear on the LCD from LCD0(0-1) to 127(126-127), that is, from the Bottom to Top, smoothly. Make sure that “OK” appears on the LCD. The sliders can be checked in any order.
64MOTIF6 / MOTIF7 / MOTIF8 //// MOTIFx Test Program //// 07:Slider : Slider-1 : xxx Slider-2 : xxx Slider-3 : xxx Slider-4 :OK yyy : Target value xxx : Current value Display of Test Conclusion: OK //// MOTIFx Test Program //// 07:Slider :OK Slider-1 :OK Slider-2 :OK Slider-3 :OK Slider-4 :OK NG No display ∗ For NG determined on the way of the test, see “C. Procedure for NG”. T08: 1KeyOn Check Initial Screen: //// MOTIFx Test Program //// 08:1KeyOn :Press [ENTER] Description: Make sure the keyboard operates normally. Procedure: Enter C3 into Key Code. C3 //// MOTIFx Test Program //// 08:1KeyOn :Press [C3 Key] Display of Test Conclusion: OK //// MOTIFx Test Program //// 08:1KeyOn :OK NG No display∗ For NG determined on the way of the test, see “C. Procedure for NG”. T09: Keyboard + AT Check Initial Screen: //// MOTIFx Test Program //// 09:Keyboard + AT :Press [ENTER] Description: Make sure the keyboard operates normally. Make sure “After Touch” operates normally. Procedure: This test makes scaling as following. MOTIF6: 61 keys, C1 to C6. MOTIF7: 76 keys, E0 to G6. MOTIF8: 88 keys, A-0 to C7. Move “After Touch” following the instructions appear on the LCD, toggling between 127 and 0, that is, Pressing and Releasing, smoothly. //// MOTIFx Test Program //// 09:Keyboard + AT : Scaling :OK After Touch : zzz yyy : Target value zzz : Current value For Keyboard inspection (C 1): //// MOTIFx Test Program //// 09:Keyboard + AT : Scaling :Press C 1 Vel=xxx After Touch : zzz xxx : Pressing key velocity yyy : Target value zzz : Current value After Touch inspection Activate (Key On) the keyboard displayed on the LCD. When the keyboard is activated (Key On), the Velocity of the action is displayed, TONE (1 KHz) sounds and the next keyboard test starts. The sound generated is a sine wave equal to 1 KHz sounding check. If an unexpected code is sent, NG appears and no sound is generated. Then, if a normal code is received, the following keyboard test starts. If all the keyboards are found to be normal, OK appears on the LCD.
65 MOTIF6 / MOTIF7 / MOTIF8 Display of Test Conclusion: OK //// MOTIFx Test Program //// 09:Keyboard + AT :OK Scaling :OK After Touch :OK NG No display ∗ For NG determined on the way of the test, see “C. Procedure for NG”. T10: PB, MW, BC Check Connect the breath controller before starting this test. Initial Screen: //// MOTIFx Test Program //// 10:PB,MW,BC :Press [ENTER] Description: Make sure “Pitch Bend, “Modulation Wheel” and “Breath Controller” operate normally. Procedure: Following the instructions appear on the LCD, For PB: Move from 64 (63-65) to 127 (126-127), then to 0 (0-1), that is, from the Center to Top, then to Bottom, smoothly. For MW: Move from 0 (0-1) to 127(126-127), that is, from the Bottom to Top, smoothly. For BC: Change from 127 (122-127) to 0 (0-5), that is, from No-blow to Blow, smoothly. If a message, “Extract Plug!” appears, pull the jack out. (OK is assumed if the value is ## or more.) //// MOTIFx Test Program //// 10:PB,MW,BC : Pitch Bend : xxx Modulation : xxx Breath : xxx yyy : Target value xxx : Current value The items can be checked in any order. Display of Test Conclusion: OK //// MOTIFx Test Program //// 10:PB,MW,BC :OK Pitch Bend :OK Modulation :OK Breath :OK NG No display ∗ For NG determined on the way of the test, see “C. Procedure for NG”.T11: Foot Controller, Foot Switch Check Initial Screen: //// MOTIFx Test Program //// 11:FC1/2,Sus/FS:Press [ENTER] Description: Make sure “Foot Controller 1/2,” “Sustain Sw” and “Foot Sw” operate normally. Procedure: Move the “Foot Controller 1/2,” following the instructions appear on the LCD, from 0 (0-2) to 127 (125-127), that is, Release to Depress, smoothly. Turn on (0) and off (1) the “Foot Switch” and “Sustain Switch”. //// MOTIFx Test Program //// 11:FC1/2,Sus/FS: FC1 :OK FC2 : xxx SustainSw : xxx FootSw : xxx yyy : Target value xxx : Current value The items can be checked in any order. Check Item: Make sure the digit changes, and OK appears on the LCD. Display of Test Conclusion: OK //// MOTIFx Test Program //// 11:FC1/2,Sus/FS :OK FC1 :OK FC2 :OK SustainSw :OK FootSw :OK NG No display ∗ For NG determined on the way of the test, see “C. Procedure for NG”. T12: MIDI In/Out/Thru Check Initial Screen: //// MOTIFx Test Program //// 12:MIDI :Press [ENTER] Description: Checks the operation of MIDI IN/OUT/THRU with a test pattern (AA EF 00 55). Procedure: Connect IN and OUT with a MIDI cable and run the test. If it is OK, make sure the MIDI monitor outputs the test pattern (AA EF 00 55) from THRU.
66MOTIF6 / MOTIF7 / MOTIF8 Check Item: Make sure IN and OUT are OK, and THRU outputs a test pattern. Display of Test Conclusion: OK //// MOTIFx Test Program //// 12:MIDI :OK NG //// MOTIFx Test Program //// 12:MIDI :NG If an unexpected data is received: //// MOTIFx Test Program //// 12:MIDI :NG TIME OUT If the reception does not complete within a certain time: Ending Process: The test ends after displaying the test conclusion and enters the item selection status. T13: USB(MIDI) Check Initial Screen: //// MOTIFx Test Program //// 13:USB(MIDI) :Press [ENTER] Description: Checks the operation of USB (MIDI) IN/OUT with a test pattern (f0 55 00 f7). Procedure: Connect the USB terminal and PC to run the test. Check Item: Make sure IN and OUT are OK. Display of Test Conclusion: OK //// MOTIFx Test Program //// 13:USB(MIDI) :OK NG //// MOTIFx Test Program //// 13:USB(MIDI) :NG Display resulted from an unexpected data //// MOTIFx Test Program //// 13:USB(MIDI) :NG TIME OUT Display resulted from reception which does not complete within a certain time: Ending Process: The test ends after displaying the test conclusion and enters the item selection status. T14: 1 kHz OUTPUT L Initial Screen: //// MOTIFx Test Program //// 14:OUTPUT-L :Press [ENTER] Description: Insert plugs into OUTPUT-L, OUTPUT-R, Assignable-L, Assignable-R, PHONES(L) and PHONES(R) to monitor the frequencies, output waveforms and output levels using a frequency counter, oscilloscope and level indicator (with JIS_C filters). Connect a device, such as an MD, to the Optical Output terminal. Set Master Volume to the max. When sounding, the LCD displays as follows: //// MOTIFx Test Program //// 14:OUTPUT-L :ON Check Item: OUTPUT-L: Sine wave, 1 kHz ± 1.5 Hz, + 5.0 ± 2 dBm (loading, 10 kΩ; distortion factor, 0.1% or less) OUTPUT-R: -80 dBm or less (loading, 10 kΩ) Assignable-L: Sine wave, 1 kHz ± 1.5 Hz, + 5.0 ± 2 dBm (loading, 10 kΩ; distortion factor, 0.1% or less) Assignable-R: -83 dBm or less (loading, 10 kΩ) PHONES(L): Sine wave, 1 kHz ± 1.5 Hz, + 6.0 ± 2 dBm (loading, 33Ω; distortion factor, 0.1% or less) PHONES(R): -60 dBm or less (loading, 33Ω) Optical: Set SONY MD WALKMAN MZ-R55 to VOL=30 and connected to Optical IN MDLINE L: -25 ± 2 dBm (loading, 10 kΩ) AIEB2 (Option) AS1, 3, 5: 1kHz ± 1.5Hz, Sine wave, +6.0 ± 2dBm (loading, 10Ω; distortion factor, 0.1% or less) AS2, 4, 6: -90dBm or less (loading, 10Ω) Display of Test Conclusion: OK: No display NG: No display Ending Process: Press [EXIT] button to exit the test. The Initial Screen reappears, waiting for a test number.
67 MOTIF6 / MOTIF7 / MOTIF8 T15: 1 kHz OUTPUT R Check Initial Screen: //// MOTIFx Test Program //// 15:OUTPUT-R :Press [ENTER] Procedure: Insert plugs into OUTPUT-L, OUTPUT-R, Assignable-L, Assignable-R, PHONES (L) and PHONES (R) to monitor the frequencies, output waveforms and output levels using a frequency counter, oscilloscope and level indicator (with JIS_C filters). Set Master Volume to max. When sounding, the LCD displays as follows: //// MOTIFx Test Program //// 15:OUTPUT-R :ON Check Item: OUTPUT-L: -80 dBm or less (loading, 10 kΩ) OUTPUT-R: Sine wave, 1 kHz ± 1.5 Hz, + 5.0 ± 2 dBm (loading, 10 kΩ; distortion factor, 0.1% or less) Assignable-L: -83 dBm or less (loading, 10 kΩ) Assignable-R: Sine wave, 1 kHz ± 1.5 Hz, + 5.0 ± 2 dBm (loading, 10 kΩ; distortion factor, 0.1% or less) PHONES(L): -60 dBm or less (loading, 33 Ω) PHONES(R): Sine wave, 1 kHz ± 1.5 Hz, + 6.0 ± 2 dBm (loading, 33 Ω; distortion factor, 0.1% or less) AIEB2 (Option) AS1, 3, 5: -90dBm or less (loading, 10 Ω) AS2, 4, 6: 1kHz ± 1.5Hz, Sine wave, +6.0 ± 2dBm (loading, 10 Ω; distortion factor, 0.1% or less) Display of Test Conclusion: OK: No display NG: No display Ending Process: Press [EXIT] button to exit the test. The Initial Screen reappears, waiting for a test number. Others: None. T16: A/D -> D/A (MIC) Check Initial Screen: //// MOTIFx Test Program //// 16:AD-DA(MIC) :Press [ENTER] Description: Tests the signal path from input to D/A output. (The Gain is defaulted to MIC.)Supply a sine wave of 1 kHz ± 5 Hz and -50.0 dBm ± 0 dBm (distortion factor, 0.1% or less) to the A/D input in the following order to make sure the level specified below is output from the Outputs L and R. //// MOTIFx Test Program //// 16:AD-DA(MIC) :ON Check Item: Move the A/D GAIN VOLUME to make sure the sound level varies. OUTPUT-L: Sine wave, 1 kHz ± 5 Hz, + 4.0 ± 2 dBm (loading, 10 kΩ; distortion factor, 2.00% or less) OUTPUT-R: -60.0 dBm or less (loading, 10 kΩ) Display of Test Conclusion: No display Ending Process: Press [EXIT] button to end sounding, waiting for a test number. Others: None. T17: A/D -> D/A (LINE) Check Initial Screen: //// MOTIFx Test Program //// 17:AD-DA(LINE) :Press [ENTER] Description: Tests the signal path from the A/D input to D/A output. (The Gain is defaulted to LINE.) Supply a sine wave of 1 kHz ± 5 Hz and -17.0 dBm ± 0 dBm (distortion factor, 0.1% or less) to the A/D input in the following order to make sure the level specified below is output from the Outputs L and R. //// MOTIFx Test Program //// 17:AD-DA(LINE) :ON Check Item: Move the A/D GAIN VOLUME to make sure the sound level varies. OUTPUT-L: -70.0 dBm or less (loading, 10 kΩ) OUTPUT-R: sine wave, 1 kHz ± 5 Hz, + 3.0 ± 2 dBm (loading, 10 kΩ; distortion factor, 0.10% or less) Display of Test Conclusion: No display Ending Process: Press [EXIT] button to stop sounding, waiting for a test number. Others: None.
68MOTIF6 / MOTIF7 / MOTIF8 T18: CARD (WRITE/READ) Check Initial Screen: //// MOTIFx Test Program //// 18:Card :Press [ENTER] Description: Make sure the Smart Media is protected. Checks the Format, Write, Read and Verify on the Smart Media. Make sure the Smart Media is removable. Procedure: First, insert a protected Smart Media into the slot and run the test. Then, insert a not-protected Smart Media into the slot and run the test. Run the test without a Smart Media inserted. Check Item: Check the result of LCD test. Make sure a WRPRT error occurs when a Smart Media is inserted. Then, make sure OK appears when a Smart Media is inserted. Display of Test Conclusion: OK //// MOTIFx Test Program //// 18:Card :OK NG //// MOTIFx Test Program //// 18:Card :NG xxxxxx xxxxxx : ERROR CODE Error code : Error code RD/WR: Read/Write error NOCARD: No card (Card not inserted) WRPRT: Write protect Ending Process: The test ends after displaying the conclusion and returns to the item select status. For NG determined on the way of the test, see “C. Procedure for NG”. T19: SCSI Initial Screen: //// MOTIFx Test Program //// 19:SCSI :Press [ENTER] Description: Performs Read/Write by 1 sector to/from a hard disk connected to a SCSI terminal. Sets the SCSI ID of the hard disk to 4.Procedure: Connect a hard disk to a SCSI terminal to run the test. Check Item: Check the LCD for the test conclusion. Display of Test Conclusion: OK //// MOTIFx Test Program //// 19:SCSI :OK NG //// MOTIFx Test Program //// 19:SCSI :NG Ending Process: The test ends after displaying the conclusion and returns to the item select status. For NG determined on the way of the test, see “C. Procedure for NG”. T20: Plug-In 1 Check Initial Screen: //// MOTIFx Test Program //// 20:PLG1 :Press [ENTER] Description: Checks for the connection at Plug-in Slot 1, sending/ reception through Control Line, MIDI Line and IN/OUT through MEL Line. If Insertion Check is successfully ended, these checks are implemented as follows: (1) Perform Board Type Request. (2) Receive Type. (3) Check to see whether it is a VH Board or not. (4) Send TEST CODE to Plug-in’s MIDI LINE. (5) Check IN/OUT on MEL Line. (6) Output 1 k.Hz sine wave to Plug-in. Procedure: Connect Vocal Harmony Plug-in Board to Plug-in Slot 1 and make sure the following level outputs from Outputs R and L exist. Before this test, set Master Volume to the max. Check Item: OUTPUT-L: Sine wave, 1 kHz ± 5 Hz, + 5.0 ± 2 dBm (loading, 10 kΩ; distortion factor, 2.00% or less) OUTPUT-R: Sine wave, 1 kHz ± 5 Hz, + 5.0 ± 2 dBm (loading, 10 kΩ; distortion factor, 2.00% or less) Display of Test Conclusion: OK No display NG //// MOTIFx Test Program //// 20:PLG1 :NG xxxxxxxx xxxxxxxx : ERROR CODE
69 MOTIF6 / MOTIF7 / MOTIF8 Error code : NG_BOARD: Board other than VH is inserted. NO_BOARD: No board (No board is inserted) MIDI: MIDI LINE faulty Ending Process: Press [EXIT] button once to stop sounding, twice to determine OK or NG or three times to enter the status waiting for a test number. T21: Plug-In 2 Check Initial Screen: //// MOTIFx Test Program //// 21:PLG2 :Press [ENTER] Description: Checks for connection at Plug-in Slot 2, sending/reception through Control Line, MIDI Line and IN/OUT through MEL Line. If Insertion Check is successfully ended, these checks are implemented as follows: (1) Perform Board Type Request. (2) Receive Type. (3) Check to see whether it is a VH Board or not. (4) Send TEST CODE to Plug-in’s MIDI LINE. (5) Check IN/OUT on MEL Line. (6) Output 1 k.Hz sine wave to Plug-in. Procedure: Connect Vocal Harmony Plug-in Board to Plug-in Slot 2 and make sure the following level outputs from Outputs R and L exist. Before this test, set Master Volume to the max. Check Item: OUTPUT-L: Sine wave, 1 kHz ± 5 Hz, + 1.0 ± 2 dBm (loading, 10 kΩ; distortion factor, 2.00% or less) OUTPUT-R: Sine wave, 1 kHz ± 5 Hz, + 1.0 ± 2 dBm (loading, 10 kΩ; distortion factor, 2.00% or less) Display of Test Conclusion: OK No display NG //// MOTIFx Test Program //// 21:PLG2 :NG xxxxxxxx xxxxxxxx : ERROR CODE Error code : NG_BOARD: Board other than VH is inserted. NO_BOARD: No board (No board is inserted) MIDI: MIDI LINE faulty Ending Process: Press [EXIT] button once to stop sounding, twice to determine OK or NG or three times to enter the status waiting for a test number.T22: Plug-In 3 button Initial Screen: //// MOTIFx Test Program //// 22:PLG3 :Press [ENTER] Description: Checks for connection at Plug-in Slot 3, sending/reception through Control Line, MIDI Line and IN/OUT through MEL Line. If Insertion Check is successfully ended, these checks are implemented as follows: (1) Perform Board Type Request. (2) Receive Type. (3) Make sure it is a VH Board. (4) Send TEST CODE to Plug-in’s MIDI LINE. (5) Check IN/OUT on MEL Line. (6) Output 1 k.Hz sine wave to Plug-in. Procedure: Connect Vocal Harmony Plug-in Board to Plug-in Slot 3 and make sure the following level outputs from Outputs R and L exist. Before this test, set Master Volume to the max. Check Item: OUTPUT-L: Sine wave, 1 kHz ± 5 Hz, + 5.0 ± 2 dBm (loading, 10 kΩ; distortion factor, 2.00% or less) OUTPUT-R: Sine wave, 1 kHz ± 5 Hz, + 5.0 ± 2 dBm (loading, 10 kΩ; distortion factor, 2.00% or less) Display of Test Conclusion: OK No display NG //// MOTIFx Test Program //// 22:PLG3 :NG xxxxxxxx xxxxxxxx : ERROR CODE Error code: NG_BOARD: Board other than VH is inserted. NO_BOARD: No board (No board is inserted) MIDI: MIDI LINE faulty Ending Process: Press [EXIT] button once to stop sounding, twice to determine OK or NG or three times to enter the status waiting for a test number. T23: Digital Input Check Initial Screen: //// MOTIFx Test Program //// 23:Digital In :Press [ENTER] Description: Tests the signal path from the AIEB1 Digital input to the D/A output.
70MOTIF6 / MOTIF7 / MOTIF8 Procedure: Loop between the AIEB1 Digital input and output to sound a sine wave to the Digital output. Make sure the following level outputs are sent out from the ChStatus, and Outputs R and L. //// MOTIFx Test Program //// 23:Digital In :ON Ch Status :xx xx : OK/NG Check Item: Ch Status: OK/NG OUTPUT-L: Sine wave, 1 kHz ± 5 Hz, + 1.0 ± 2 dBm (loading, 10 kΩ; distortion factor, 0.1% or less) Display of Test Conclusion: NG //// MOTIFx Test Program //// 23:Digital In :ON Ch Status :NG Ending Process: Press [EXIT] button to end sounding, waiting for a test number. T24: Optical Input Check Initial Screen: //// MOTIFx Test Program //// 24:Optical In :Press [ENTER] Description: Tests the signal path from the AIEB2 Optical input to D/A output. Procedure: Loop between the AIEB2 Optical input and output to sound a sine wave to the Optical output. Make sure the following level outputs are sent out from the ChStatus, and Outputs R and L. //// MOTIFx Test Program //// 24:Optical In :ON Ch Status :xx xx : OK/NG Check Item: Ch Status: OK/NG OUTPUT-L: Sine wave, 1 kHz ± 5 Hz, + 1.0 ± 2 dBm (loading, 10 kΩ; distortion factor, 0.1% or less) Display of Test Conclusion: NG //// MOTIFx Test Program //// 24:Optical In :ON Ch Status :NG Ending Process: Press [EXIT] button to end sounding, waiting for a test number. T25: SIMM Check Initial Screen: //// MOTIFx Test Program //// 25:SIMM :Press [ENTER] Description: Performs Read, Write and Verify tests on SIMM. Procedure: Run the test. Check Item: Check the LCD for the test conclusion. Display of Test Conclusion: OK //// MOTIFx Test Program //// 25:SIMM :OK CN-19:OK CN-20:OK NG //// MOTIFx Test Program //// 25:SIMM :NG CN-19:OK CN-20:NG If any IC is found to be NG, this test determines NG. Ending Process: The test ends after displaying the conclusion and returns to the item select status. T26: SIMM Full R/W Test Initial Screen: //// MOTIFx Test Program //// 26:SIMM(Full) :Press [ENTER] Description: Performs Full Address Read, Write and Verify tests on SIMM. Procedure: Run the test. Check Item: Check the LCD for the test conclusion. Display of Test Conclusion: OK //// MOTIFx Test Program //// 26:SIMM(Full) :OK CN-19:OK CN-20:OK