Page 291
Data List 38 [Conversion from actual data to bulk data]d[0-6]: actual data b[0-7]: bulk data b[0] = 0; for( I=0; I
Page 292
Data List 39 4.2.3 Module Name *1) 0:CH1 - 71:CH72 72:ST IN 1L - 87:ST IN 8R *2) 256:MIX 1 - 279:MIX 24 *3) 512:MATRIX 1 - 519: MATRIX 8 *4) 1024:STEREO L - 1026:STEREO C *5) 512: will be used if the recalling or storing data is only one. *6) 0: GEQ1A, 1: GEQ1B, 2: GEQ2A, ... 36: GEQ19A, 37:GEQ19B 38: EFFECT GEQ1A, 39: EFFECT GEQ1B, 40: EFFECT GEQ2A, ... 52: EFFECT GEQ8A, 53: EFFECT GEQ8B *7) 0:Effect1- 7:Effect8 *8) 1280:CH1 - 1351:CH72 1352:ST IN 1L - 1367:ST IN 8R *9) 0: Premium Rack 1A,...
Page 293
Data List 40 4.4 FUNCTION CALL - LIBRARY ATTRIBUTE -4.4.1 Format (PARAMETER CHANGE) ReceptionData will be received when [PARAMETER CHANGE Rx] is on and the Device number of both [Rx CH] and SUB STATUS match. The data will be echoed when [PARAMETER CHANGE ECHO] is on. When the message is received, the title of the specified memory/library will be edited.TransmissionPARAMETER CHANGE will be sent in reply to Request. If [PARAMETER CHANGE ECHO] is on, the message will be sent as it is. 4.4.2 Format...
Page 294
Data List 41 4.5.2 Format (PARAMETER REQUEST) ReceptionThe PARAMETER CHANGE will be sent with Device number [Rx CH] immediately the data is received.4.5.3 Module Name 4.6 FUNCTION CALL - COLLECTION STORE -4.6.1 Format (PARAMETER CHANGE) TransmissionData will be transmitted with the [Device Number] in [Tx CH] when [PARAMETER CHANGE Tx] is on.4.6.2 Function Name 4.6.3 Module Name 4.7 FUNCTION CALL - MODULE -4.7.1 Format (PARAMETER CHANGE) ReceptionData will be received when [PARAMETER CHANGE Rx] is on...
Page 295
Data List 42 4.8 FUNCTION CALL - CHANNEL -4.8.1 Pair ON/OFF Trigger Format (PARAMETER CHANGE) ReceptionData will be received when [PARAMETER CHANGE Rx] is on and the Device number of both [Rx CH] and SUB STATUS match. The data will be echoed when [PARAMETER CHANGE ECHO] is on.4.8.2 Module Name *1) 0:CH1 - 71:CH72 256:MIX 1 - 279:MIX 24 512:MATRIX 1-519:MATRIX 8 4.9 LEVEL METER DATA4.9.1 Format (PARAMETER CHANGE)When transmission is enabled by receiving Request for Level Meter, the corresponding...
Page 296
Data List 43 Input/output characteristics ANALOG INPUT CHARACTERISTICS *1. Sensitivity is the lowest level that will produce an output of +4dBu (1.23V) or the nominal output level when the unit is set to maximum gain. (all faders and level controls are maximum position.) *2. XLR-3-31 type connectors are balanced. (1= GND, 2= HOT, 3= COLD) * In these specifications, 0dBu= 0.775 Vrms. * All input AD converters are 24bit linear, 128times oversampling. * +48V DC ( phantom power ) is supplied to ONI IN...
Page 297
Data List 44 I/O SLOT (1-3) CHARACTERISTICSEach I/O Slot accepts a mini-YGDAI card. Only Slot1 has a serial interface.CONTROL I/O CHARACTERISTICS *1. Input pin: TTL level, w/ internal pull-up (47kΩ) Output pin: Open drain output (Vmax=12V, maximum sink current/pin=75mA) Power supply pin: Output voltage Vp=5V, Max. output current Imax=300mA *2. 4 pin=+12V, 3 pin=GND, Lamp rating 5W. Voltage control by software.Terminal Format Level Connector MIDIIN MIDI - DIN Connector 5P OUT MIDI - DIN Connector 5P WORD...
Page 298
Data List 45 Electrical Characteristics All faders are nominal when measured. Output impedance of signal generator:150ohms Frequency Response. Fs= 44.1 kHz or 48 kHz @20 Hz-20 kHz, referenced to the nominal output level @1 kHz Total Harmonic Distortion. Fs= 44.1 kHz or 48 kHz * Total Harmonic Distortion is measured with a 18 dB/octave filter @80 kHz Hum & Noise. Fs= 44.1 kHz or 48 kHz, EIN= Equivalent Input Noise * Hum & Noise are measured with A-weight filter. Dynamic Range. Fs= 44.1 kHz or...
Page 299
Data List 46 Mixer Basic Parameters Libraries Input Function Output Function Output Port Processor Name Number To t a l Scene Memory Preset 1 + User 300 301 Input CH Library Preset 1 + User 199 200 Output CH Library Preset 1 + User 199 200 Input EQ Library Preset 40 + User 159 199 Output EQ Library Preset 3 + User 196 199 Dynamics Library Preset 41 + User 158 199 Effect Library Preset 27 + User 172 199 GEQ Library Preset 1 + User 199 200 Premium Rack Library Portico5033 Portico5043 U76 Opt-2A...
Page 300
Data List 47 Pin Assignment DC POWER INPUT GPI METER (CL3/CL1 only) Pin Signal Name Pin Signal Name 1+24V13GND 2+24V14GND 3+24V15GND 4+24V16GND 5+24V17GND 6+24V18GND 7+24V19CAUTION(+) 8 +24V 20 CAUTION(-) 9 +24V 21 DETECT A 10 GND 22 DETECT B 11 GND 23 DETECT GND 12 GND Frame GND 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Pin Signal Name Pin Signal Name 1GPO19GPO2 2GPO310GPO4 3GPO511GND 4GND12GND 5 +5V 13 +5V 6 GPI114GPI2 7 GPI315GPI4 8GPI5 9 10 11 8 1 2 3 15 Pin Signal Name Pin Signal...