Page 841
6/02 6-77 DC1632/2240 dC351 General Procedures and Information Prelaunch Training/Review dC351 NVM Background ProcessingPurposeConsists of 5 subroutines: ïMachine Settings - This routine saves the current machine settings or restores the pre- viously-saved machine settings. ï Manufacturing NVM - This routine automatically loads a region-specific set of values into NVM. ïDust Off Reset - This routine sets all HFSI counters to zero. NOTE: The following subroutines are intended for...
Page 842
6/02 6-78DC1632/2240 dC355, dC371 Prelaunch Training/Review General Procedures and Information dC355 Hard Disk Diagnostic ProgramPurposeNOTE: For details on dC355 Hard Disk Diagnostic Program, see Adjustments: ADJ 9.8. dC371 Configuration PagePurposeAllows easy viewing and set-up of machine configuration.Procedure1. Enter the Diagnostic Mode. Refer to Entering Diagnostic Mode using the PWS. 2. Select Adjustments on the Service Entry Screen. 3. Select NVM Init, S/R (the default screen). 4. Select...
Page 843
6/02 6-79 DC1632/2240 dC612 General Procedures and Information Prelaunch Training/Review dC612 Color Test Pattern PrintPurposePrints the test patterns in the machine, to help identify Image Quality problems.Procedure1. Enter the Diagnostic Mode. Refer to Entering Diagnostic Mode using the PWS. 2. Select Diagnostics in the Service Entry Screen. 3. Select Test Pattern (dc612). a. To print a Test Pattern, select Image Process System: i. Select the Pattern Number from the menu. ii. Select the Paper Tray....
Page 844
6/02 6-80DC1632/2240 dC612 Prelaunch Training/Review General Procedures and Information11 Binary/Auto Gradation Correction PG (For Printer) LUT: C-TRA OFF IOT ON(For gradation correction) Gradation pattern for gradation correction for printing LUT: C-TRA OFF IOT ONTo output during Auto Gradation Correction. For checking CTRACS feature. The same pattern as this output pattern is even output in the CTRACS feature (Reads the output pattern by IIT and sets up the color reproducibility) inside the...
Page 845
6/02 6-81 DC1632/2240 dC612 General Procedures and Information Prelaunch Training/Review22 Binary/Highlight PG LUT: C-TRA OFF IOT OFF(Highlight gradation check) Gradation pattern for highlight adjustment LUT: C-TRA OFF IOT OFFIn the gradation reproducibility of Primary color/Secondary color/ Tertiary color, the highlight parts easily varied can be checked in details. For checking TRC.IPS 23 Binary/Highlight PG LUT: C-TRA OFF IOT ON(Highlight gradation check) Gradation pattern for highlight...
Page 846
6/02 6-82DC1632/2240 dC612 Prelaunch Training/Review General Procedures and Information37 VIPER Fixed Pattern Output/BW Binary(For separating troubles) Connection between IPS-Controller CHK Entire 2dot width Horizontal Ladder Pattern.For development. Determine the defect locations when IPS defect and ASIC poor installation etc. has occurred.IPS 38 VIPER Fixed Pattern Output/4C Binary(For separating troubles) Entire 2dot width Horizontal Ladder Pattern. For development. Determine the defect locations...
Page 847
6/02 6-83 DC1632/2240 dC685, dC921 General Procedures and Information Prelaunch Training/Review dC685 Color RegistrationPurposeNOTE: For details on dC685 Color Registration, see Adjustments Section 4: ADJ 9.6. dC921 TC/ATC Sensor SetupPurposeNOTE: For details on dC921 TC/ATC Sensor Setup, see Adjustments Section 4: ADJ 9.2.
Page 848
6/02 6-84DC1632/2240 dC922, dC924 Prelaunch Training/Review General Procedures and Information dC922 TRC ControlPurposeNOTE: For details on dC922 TRC Control, see Adjustments Section 4: ADH 9.3 dC922 TRC Control Adjustment. dC924 TRC AdjustPurposeTo manually fine adjust the low/medium/high densities (TRC) for each color. NOTE: For details on TRC Adjust, see Adjustments Section 4: ADJ 9.5.
Page 849
6/02 6-85 DC1632/2240 dC929, dC934 General Procedures and Information Prelaunch Training/Review dC929 Max SetupPurposeNOTE: For the execution sequence of the Max Setup Functions, see Adjustments Section 4: ADJ 9.1. dC934 ADC/AGC SetupPurposeAutomatically adjusts the ADC Sensor Gain. NOTE: For details on dC934 ADC/AGC Setup, see Adjustment Section 4: ADJ 9.4.
Page 850
6/02 6-86DC1632/2240 dC945, dC956 Prelaunch Training/Review General Procedures and Information dC945 IIT CalibrationPurposeFunctional details: ï Computes and sets the White Reference Correction Coefficient. ï Corrects the IIT Sensitivity Dispersion. NOTE: For details on dC945 IIT Calibration, see Adjustments Section 4: ADJ 9.7. dC956 Belt Edge Learn Mode PurposeNOTE: For details on dC956 Belt Edge Learn Mode, see Adjustments Section 4: ADJ 9.6.