Page 831
6/02 6-67 DC1632/2240 dC132, dC135 General Procedures and Information Prelaunch Training/Review dC132 Serial Number/Billing Meter SynchronizationPurposeChecks the Billing Meters and sets the Machine Serial Number when fault 103-208 occurs. This routine also reads the Billing Meters and can be accessed at any time for this purpose.Procedure CAUTION Failure to comply with the board replacement procedure in GP 10 Replacing Billing PWBs, could result in catastrophic NVM corruption. Follow the procedure...
Page 832
6/02 6-68DC1632/2240 dC140, dC188 Prelaunch Training/Review General Procedures and Information dC140 Analog MonitorPurposeMonitors the analog values of the A/D converter sensors by driving each component (e.g.;, C.C). Temporary change of output values is possible. Output component check is also possi- ble.Procedure1. Enter the Diagnostic Mode. Refer to Entering Diagnostic Mode using the PWS. 2. Select the Analog Monitor (dC140) tab in the Diagnostics Screen. 3. The system displays the Analog Monitor...
Page 833
6/02 6-69 DC1632/2240 dC301 General Procedures and Information Prelaunch Training/Review dC301 NVM InitializationPurposeThis procedure may be needed when the machine cannot recover for some unknown reasons, including problems such as producing blank copies/prints, Xerographic CRUs not recognized, continuously giving system fault, etc.Initial Actions to be taken:Obtain all of the following information: ï Disconnect any Foreign Interface Devices prior to performing this procedure. ï NVM Value Factory...
Page 834
6/02 6-70DC1632/2240 dC305, dC330 Prelaunch Training/Review General Procedures and Information dC305 UI Component CheckPurposeChecks the operations of the UI Screen and Control Panel buttons.Procedure1. Enter the Diagnostic Mode. Refer to Entering Diagnostic Mode using the PWS. 2. Select the Diagnostics Tab in the Service Entry Screen. 3. Select the System Test Tab in the Diagnostics Screen. The System Test Screen displays. The UI Component Check dC305 is the default screen. 4. Select Start. The...
Page 835
6/02 6-71 DC1632/2240 dC330 General Procedures and Information Prelaunch Training/Review001-306 INTLK_3 High when Open is detected. ON: High 004-100 Belt Home Sensor [Operation Description]: IBT is not at Home Posi- tion. Open circuit. It is necessary to operate IBT 5V ON. ON: High 004-101 Drum Motor YMC Fail Detec- tionPR (Drum) Motor YMC Failure ON: High 004-102 Drum Motor K Fail Detection PR (Drum) Motor K Failure ON: High 004-200 FAN_LOCK_FAIL Fan rotation is stopped ON: FAIL 005-102 Document Sensor...
Page 836
6/02 6-72DC1632/2240 dC330 Prelaunch Training/Review General Procedures and Information009-153 #C_CRU detect CRU is installed 009-154 #K_CRU detect CRU is installed 009-200 2nd BTR Retract Sensor RetractiON. ON: Low 009-201 POB Sensor Paper detected ON: Low 009-203 1st BTR Retract Sensor RetractiON. ON: Low 010-101 Fuser Exit Paper detected ON: High 010-102 Full Paper Stack Sensor NotFull ON: Low 010-103 Face Up Exit Sensor Paper detected ON: High 012-100 IOT Regi Clutch Clutch OFF ON: High 012-101...
Page 837
6/02 6-73 DC1632/2240 dC330 General Procedures and Information Prelaunch Training/Review005-081 Exit Motor Non CVT ModeOperate the DADF Exit Motor - 005-083 Doc Ready switch ON the Doc Ready signal. - 005-084 Doc Set LED switch ON the DOC SET LED - 006-002 IIT Exposure Lamp switch the Lamp ON for 180sec -> Auto OFF - 006-004 IPS Cooling Fan (Low speed)After operating the IPS Cooling Fan at high speed for 5sec, operate it at low speed. ON: FAN ON: 24V, FAN Slow: L->H (About 13V) - 006-005 IIT...
Page 838
6/02 6-74DC1632/2240 dC330 Prelaunch Training/Review General Procedures and Information008-030 TTM TA Motor (104mm/sec)Start operation. Turns OFF automatically at 1000msec. 8-029, 031, 032, 033, 034, 035, 036 008-031 TTM TA Motor (192mm/sec)Start operation. Turns OFF automatically at 1000msec. 8-029, 030, 032, 033, 034, 035, 036 008-032 TTM TA Motor (370mm/sec)Start operation. Turns OFF automatically at 1000msec. 8-029, 030, 031, 033, 034, 035, 036 008-033 TTM TA Motor (52mm/sec)...
Page 839
6/02 6-75 DC1632/2240 dC330 General Procedures and Information Prelaunch Training/Review009-026 #Y_BCR DC High voltage output value of BCR DC_Y. ON: PWM 9-30 009-027 #M_BCR DC High voltage output value of BCR DC_M. ON: PWM 9-31 009-028 #C_BCR DC High voltage output value of BCR DC_C. ON: PWM 9-32 009-029 #K_BCR DC High voltage output value of BCR DC_K. ON: PWM 9-33 009-030 #Y_BCR AC High voltage output value of BCR AC_Y. ON: PWM 9-26 009-031 #M_BCR AC High voltage output value of BCR AC_M 9-27...
Page 840
6/02 6-76DC1632/2240 dC330 Prelaunch Training/Review General Procedures and Information012-032 Eject Clamp Low DownTurns OFF automatically at 702pulses after the Eject Home Snr detected Home Posi- tion. 12-30, 12-31, 12-33, 12-34, 12-41 012-033 Eject Clamp Mid- dle DownTurns OFF automatically at 365pulses after the Eject Home Snr detected Home Posi- tion. 12-30, 12-31, 12-32, 12-34, 12-41 012-034 Eject Clamp UP Turns OFF automatically at 46pulses after the Eject Home Snr detected Home Posi- tion....