Xerox 1632 2240 3535 Color Carrera Manual
Here you can view all the pages of manual Xerox 1632 2240 3535 Color Carrera Manual. The Xerox manuals for All in One Printer are available online for free. You can easily download all the documents as PDF.
Page 431
6/02 2-401 DC1632/2240 116-714, 116-715 Status Indicator RAPs Prelaunch Training/Review 116-714 A HP-GL command error was detected[Detection Conditions] HP-GL/2 command errorProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Correct or remove the data in the print data that causes the error. 116-715 PLW form registry errorThe PLW form data cannot be registered because of the restriction of the number of forms.ProcedureSwitch power off then on. The problem...
Page 432
6/02 2-402DC1632/2240 116-718, 116-737 Prelaunch Training/Review Status Indicator RAPs 116-718 PLW form synthesis errorThe specified form is not registered.ProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Use a registered form, or register a necessary form. 116-737 Insufficient ART user defined areaThe user defined data (external characters, patterns, etc.) cannot be registered because of insufficient RAM capacity.ProcedureSwitch power off then on. The...
Page 433
6/02 2-403 DC1632/2240 116-738, 116-739 Status Indicator RAPs Prelaunch Training/Review 116-738 Form synthesis errorSynthesis is impossible because the size/orientation of the forms drawing is different from that of the paper.ProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Select the paper with the size and orientation of the registered form. 116-739 Insufficient form/logo capacityThe form/logo data cannot be registered because of the insufficient RAM or...
Page 434
6/02 2-404DC1632/2240 116-740, 116-741 Prelaunch Training/Review Status Indicator RAPs 116-740 Value Calculation ErrorThe number calculated in the interpreter exceeded the limit value.ProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Remove the data that exceeds the limit value of the printer from the print data. 116-741 Form registry errorThe form data cannot be registered because of the restriction of the number of forms.ProcedureSwitch power off then on....
Page 435
6/02 2-405 DC1632/2240 116-742, 116-743 Status Indicator RAPs Prelaunch Training/Review 116-742 Logo registry errorThe logo data cannot be registered because of the restriction of the number of logos.ProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Use the Operation Panel utility to check the registered logos, and delete unnecessary ones. Or delete unnecessary logos with the Print command. 116-743 Form/logo size overflowThe received data (forms/logos)...
Page 436
6/02 2-406DC1632/2240 116-745, 116-746 Prelaunch Training/Review Status Indicator RAPs 116-745 Art Command ErrorThe decomposer checks the syntax error and excess of each limit value at decomposing.ProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Correct the command. Change the ART command where an error has occurred. 116-746 Form synthesis errorThe specified form is not registered.ProcedureSwitch power off then on. The problem continues. YN Return to...
Page 437
6/02 2-407 DC1632/2240 116-747, 116-748 Status Indicator RAPs Prelaunch Training/Review 116-747 White page detectedAfter subtracting the paper margin from the valid coordinate area, the result of the calculation will be negative.ProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Again, switch power off then on. No actions required. 116-748 White page detected[Detection Conditions] There is no drawing data in the page data.ProcedureSwitch power off then on....
Page 438
6/02 2-408DC1632/2240 116-780, 116-790 Prelaunch Training/Review Status Indicator RAPs 116-780 Attached document failure of email to XXXProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Attached document failure of email to XXX No actions required. 116-790 Printed without the staplerProcedureSwitch power off then on. The problem continues. YN Return to service call procedures. Printed without the stapler No actions required.
Page 439
6/02 2-409 DC1632/2240 OF 1-1 Status Indicator RAPs Prelaunch Training/Review OF 1-1 +3.5 VDC+3.5 VDC failure.ProcedurePerform following: ï Remove Rear Cover (REP 14.2). ï Tilt out HVPS Chassis (REP 1.6). Check that power is switched off. Measure resistance of fuse on +3.5V LVPS (Figure 1). Resistance is 1 ohm or less. YN Replace +3.5V LVPS (PL 9.1). Switch on the power. Measure the AC voltage between the white and black wires in p15 on the +3.5V LVPS (Figure 1). 110 or 220 VAC is measured. YN Go to...
Page 440
6/02 2-410DC1632/2240 OF 1-2 Prelaunch Training/Review Status Indicator RAPs OF 1-2 +5 VDC+5 VDC failure.ProcedurePerform following: ï Remove Rear Cover (REP 14.2). ï Tilt out HVPS Chassis (REP 1.6). Check that power is switched off. Measure resistance of fuse on +5V LVPS (Figure 1). Resistance is 1 ohm or less. YN Replace +5V LVPS (PL 9.1). Switch on the power. Measure the AC voltage between the black and white wires in P16 on the +5V LVPS (Figure 1). 110 or 220 VAC is measured. YN Go to the AC Power...